HomeMy WebLinkAboutCertificate of Occupancy Report - 09/24/2003 __ IcsA__Lk 0--J3 •
q. a (4 • 3
Status as of: G • a3 O a /I d • q • Oa / q Q. a. • O • i
Address: a d g • Ko- Q4,1 S
Project: 1V ? l4 C i 1 c 6eltoi& 16
Plan �J a3 •(�L -IO
.. o al-1 lr�:
.. ............. . ............... • • s ectic�n.
c�. �l. dates:=: _ >•
Building: - 7' ( cpa
Permit #: g3yL
R ✓Lak E C2e..,4 c- ..Lln S (J . 9/2 4 1/e'3,
Electric: 0Y-1 / I (p —
Permit # : a �l 0l a. t.O r / p Pig_c) rs g _ ' X
�e3. i°
Permit# : C ty g a
Plumbing 7. 1 (Q oa
Permit # : G(?)(pa%
Notes:
Building Permit Work Card
Job Address 280 S KOELLER ST Permit Number 0093461 Create Date 4/4/02
Owner PRODUCTION INC C & J FOOD Contractor FOX CITIES CONST CORP
Category 203 - New Amusement, Social, Recreation
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan E3 -23 -0402
Zoning C2 Class of Const: 8 Size irreg Value $420,000.00
Unfinished /Basement 0 Sq. Finished /Living 6910 Sq. Ft. Garage 0 Sq. Ft.
Ft.
Rooms 0 Bedrooms 0 Baths 0 ❑ Projection
Stories 1 Height 0 Ft. Canopies 0 Signs 0
Foundation • Poured Concrete 0 Floating Slab 0 Pier 0 Other
0 Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain Height Permit
Park Dedication # Dwelling Units 0 # Structures 1
Use /Nature New 6910 sf restaurant.* Note: No work to commence above the foundation until Landscape and Dumpster
of Work Enclosure Plans are approved and a copy of the State Stamped Approved Plan is provided to this office.
HVAC Contr Plumbing Contr
Electric Contr
Inspections:
Date 7/18/02 Type Re Final Inspector Allyn Dannhoff approved
Per Gary - Relnsp - Thursday 7/18/02.
Slab on grade. 210 Occ.
Date/Time requested: 7/15/02 Notice Type: Phone Number:
Access:
Ready Date/Time: 7/18/02 Requested By:
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Building Permit Work Card
Job Address 280 S KOELLER ST Permit Number 0093461 Create Date 4/4/02
Owner PRODUCTION INC C & J FOOD Contractor FOX CITIES CONST CORP
Category 203 - New Amusement, Social, Recreation
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan E3 -23 -0402
Zoning C2 Class of Const: 8 Size irreg Value $420,000.00
Unfinished /Basement 0 Sq. Finished /Living 6910 Sq. Ft. Garage 0 Sq. Ft.
Ft.
Rooms 0 Bedrooms 0 Baths 0 ❑ Projection
Stories 1 Height 0 Ft. Canopies 0 Signs 0
Foundation • Poured Concrete 0 Floating Slab 0 Pier 0 Other
0 Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain Height Permit
Park Dedication # Dwelling Units 0 # Structures 1
Use /Nature New 6910 sf restaurant.* Note: No work to commence above the foundation until Landscape and Dumpster
of Work Enclosure Plans are approved and a copy of the State Stamped Approved Plan is provided to this office.
HVAC Contr Plumbing Contr
Electric Contr
Inspections:
Date 5/29/02 Type Insulation Inspector Allyn Dannhoff no time
Date/Time requested: 5/28/02 02:30 PM Notice Type: Phone Number:
Access:
Ready Date/Time: 5/28/02 02:30 PM Requested By: Keith of FCC
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Date 7/15/02 Type Final Inspector Allyn Dannhoff not approved
Spoke with Gary (FCC) about these. 1) Wrap exhaust hood ducts. 2) Firestop partition walls in kitchen. 3) Kitchen bath & janitor closet
exhaust fans - operate when occupied. 4) Capacity sign. 5) Dumpster enclosure. 6) Heap pking signs.
Date/Time requested: Notice Type: Phone Number:
Access:
Ready Date/Time: Requested By:
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Building Permit Work Card
Job Address 280 S KOELLER ST Permit Number 0093461 Create Date 4/4/02
Owner PRODUCTION INC C & J FOOD Contractor FOX CITIES CONST CORP
Category 203 - New Amusement, Social, Recreation
Type • Building ❑ Sign 0 Canopy ❑ Fence 0 Raze I Plan E3 -23 -0402
Zoning C2 Class of Const: 8 Size irreg Value $420,000.00
Unfinished /Basement 0 Sq. Finished /Living 6910 Sq. Ft. Garage 0 Sq. Ft.
Ft.
Rooms 0 Bedrooms 0 Baths 0 ❑ Projection j
Stories 1 Height 0 Ft. Canopies 0 Signs 0
Foundation a Poured Concrete O Floating Slab 0 Pier 0 Other
0 Concrete Block 0 Post O Treated Wood
Occupany Permit Required Flood Plain Height Permit
Park Dedication # Dwelling Units 0 # Structures 1
Use /Nature New 6910 sf restaurant.* Note: No work to commence above the foundation until Landscape and Dumpster
of Work Enclosure Plans are approved and a copy of the State Stamped Approved Plan is provided to this office.
HVAC Contr Plumbing Contr
Electric Contr
Inspections:
Date 4/4/02 Type Footings Inspector Allyn Dannhoff
On 4/4/02 Q 1:59pm Lori from Delrar called to request an inspection. It's ready today PM. #731 -5464
*INSUFFICIENT NOTICE - Allyn is off on Friday, 4/5/02.
Date/Time requested: Notice Type: Phone Number:
Access:
Ready Date/Time: Requested By:
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Date 5/23/02 Type Rough In Inspector Allyn Dannhoff approved
Need to: Draftstop /Compartmentize attic. Draftstop studwalls to attic. Draftstop soffits to attic. Review wall /ceiling requirements for
hood.
Date/Time requested: Notice Type: Phone Number:
Access:
Ready Date/Time: Requested By:
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Building Wiring
Service Q New 0 Change Q Temp 0 N/A Type 0 Overhead • Underground 0 N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02** Garbage Disposal, Dishwasher, Fan or blower, Fumace, A/C, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 03/25/2003 Type Consultation Inspector Kevin Benner approved
The labeling on the equipment was all written in Chineese: It appeared that all of the associated equipment was
designed for a wet location.
Date /me requested: 03/24/2003 01:14 PM Notice Type: Phone Number:
Access:
Meet Greg on site
Ready Date/Time: 03/25/2003 10:00 AM Requested by:
Q Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Building Wiring
Service ❑ New 0 Change❑ Temp 0 N/A Type 0 Overhead • Underground 0 N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02 ** Garbage Disposal, Dishwasher, Fan or blower, Furnace, NC, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 07/26/2002 Type Re Final Inspector Kevin Benner not approved
Re- inspect for the neon installation.
INTERIOR NEON WRONG. EXT OK. LABELING & BKR LOXS.
Date/Time requested: 07/26/2002 10:37 AM Notice Type: Phone Number:
Access:
Look for Kelly from Appleton signs
Ready Datemme: 07/26/2002 10:37 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Date 08/01/2002 Type Final Inspector Kevin Benner not approved
Exterior signage approved, interior signage not corrected.
Date/Time requested: 08/01/2002 00:00 AM Notice Type: Phone Number:
Access:
Met Matt G. from E.C. on site
Ready Date/Time: 08/01/2002 00:00 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Budding Wiring
Service 0 New 0 Change 0 Temp 0 N/A Type 0 Overhead • Underground 0 N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02 ** Garbage Disposal, Dishwasher, Fan or blower, Furnace, NC, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 07/15/2002 Type Final Inspector Kevin Benner not approved
See Field Notes
Date/Time requested: 07/10/2002 01:23 PM Notice Type: Phone Number:
Access:
Ready Date/Time: 07/15/2002 00:00 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Date 07/18/2002 Type Re Final Inspector Jon Fischer not approved
1) Breaker locks. 2) Panel space. 3) Neon signs.
Date/Time requested: 07/16/2002 07:32 AM Notice Type: Phone Number:
Access:
Meet John Fisher on site to turn the inspections over to him
Ready Date/Time: 07/16/2002 07:32 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Building Wiring
Service 0 New 0 Change 0 Temp 0 N/A Type 0 Overhead • Underground 0 N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02** Garbage Disposal, Dishwasher, Fan or blower, Furnace, A/C, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 05/24/2002 Type Rough In Inspector Kevin Benner approved
Date/Time requested: 05/22/2002 10:41 AM Notice Type: Phone Number:
Access:
Ready Date/Time: 05/22/2002 10:41 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Date 06/03/2002 Type Service Inspector Kevin Benner approved
FAXED & MAILED TO WPS 6/3/02
100KAIC MCB
Date/Time requested: 05/31/2002 12:43 PM Notice Type: Phone Number: 410 -5174
Access:
Jim
Ready Date/Time: 05/31/2002 12:43 PM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
HVAC Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94182 Create Date 05/08/2002
Owner PRODUCTION INC C & J FOOD Contractor CONDON TOTAL COMFORT
Category 512 - Ind. & Comm -Both Plan
Fuel ✓j Gas 1 Oil I 1 Electric 1 1 Solar 1 1 Solid Value $93,180.00
System 0 New ❑ Replace 1 ❑ Other
Li] Forced Air Li Radiant Li Steam ✓j NC u Vent
Li Electric Li Hot Water Li Suppl. Li Con. Bumer
Chimney Type Q Chimney A 0 Chimney B • Direct Vent 0 Not Applicable
Heat Loss 0 As Approved 0 Existing 0 Not Applicable Value 0
BTU Rate 0 As Per Plan 0 Variable 0 Other Value
Use /Nature COMM/ Install HVAC system for new restaurant.
of Work
Inspections:
Date 7/18/02 Type Final Inspector Allyn Dannhoff approved
Date/Time requested: Notice Type: Phone Number:
Access:
Ready Date/Time: Requested By:
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Plumbing Permit Work Card
Job Address 280 S KOELLER ST Permit Number 93628 Create Date 04/15/2002
Owner PRODUCTION INC C & J FOOD Contractor JIM'S PLUMBING
Category 440 - Industrial- Interior Plan D1 -20- 0402 -P Value $43,200.00
Bathtub 0 Shower 0 Ejector /Grind 0 Dip Well 0 F Prep Sink 1 Gar Drain 0
Whirlpool 0 Floor Drain 6 Water Softner 0 Drink Ftn 0 Sery Sink 1 Soda Disp 2
Lavatory 7 Lndry Tray 0 Local Waste 0 Wait. St. 1 Shamp Sink 0 Coffee Maker 0
Toilet 7 Lndry Stndp 0 Clothes Wshr 0 Ice Chest 2 FIr/Wst Sink 0 Int Grease Trap 0
Res. Sink 0 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 1
Bar Sink 0 Dishwasher 1 Beer Tap 0 Sculry Sink 1 Wash Ftn 0
Water Heater 1 Sump Pump 0 Dent. Oper. 0 Hand Sink 1 Urinal 2
Site Drain 15 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 1
Use /Nature
of Work RESTAURANT INTERIOR/ EXTERIOR PLUMBING
Size Material Type # Conn.Type
Sanitary Sewer 4" Plastic Lateral 1 Relay
0
0
0
0
Storm Sewer 0
0
0
0
0
Water Service 1 -1/2" Copper Lateral 1 Relay
0
0
0
0
Date 7/16/02 Type Final Inspector WJ (Chip) Callies approved
Faxed Request
Date/Time requested: 7/16/02 07:23 AM Notice Type: Telephone Number: 920 - 757 -5258
Access:
Ready Date/Time: 7/16/02 07:23 AM Requested By: JIM'S PLUMBING -Jeff
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Plumbing Permit Work Card
Job Address 280 S KOELLER ST Permit Number 93628 Create Date 04/15/2002
Owner PRODUCTION INC C & J FOOD Contractor JIM'S PLUMBING
Category 440 - Industrial- Interior Plan D1 -20- 0402 -P Value $43,200.00
Bathtub 0 Shower 0 Ejector /Grind 0 Dip Well 0 F Prep Sink 1 Gar Drain 0
Whirlpool 0 Floor Drain 6 Water Softner 0 Drink Ftn 0 Sery Sink 1 Soda Disp 2
Lavatory 7 Lndry Tray 0 Local Waste 0 Wait. St. 1 Shamp Sink 0 Coffee Maker 0
Toilet 7 Lndry Stndp 0 Clothes Wshr 0 Ice Chest 2 FIr/Wst Sink 0 Int Grease Trap 0
Res. Sink 0 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 1
Bar Sink 0 Dishwasher 1 Beer Tap 0 Sculry Sink 1 Wash Ftn 0
Water Heater 1 Sump Pump 0 Dent. Oper. 0 Hand Sink 1 Urinal 2
Site Drain 15 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 1
Use /Nature
of Work RESTAURANT INTERIOR/ EXTERIOR PLUMBING
Size Material Type # Conn.Type
Sanitary Sewer 4" Plastic Lateral 1 Relay
0
0
0
0
Storm Sewer 0
0
0
0
0
Water Service 1 -1/2" Copper Lateral 1 Relay
0
0
0
0
Date 5/20/02 Type Rough In Inspector WJ (Chip) Callies approved
FAXED REQUEST
Date/Time requested: 5/17/02 08:17 AM Notice Type: Telephone Number: 757 -5258
Access:
Bldg is OPEN
Ready Datemme: 5/20/02 Requested By: JIM'S PLUMBING - Jeff
Q Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Plumbing Permit Work Card
Job Address 280 S KOELLER ST Permit Number 93628 Create Date 04/15/2002
Owner PRODUCTION INC C & J FOOD Contractor JIM'S PLUMBING
Category 440 - Industrial- Interior Plan D1- 20- 0402 -P Value $43,200.00
Bathtub 0 Shower 0 Ejector /Grind 0 Dip Well 0 F Prep Sink 1 Gar Drain 0
Whirlpool 0 Floor Drain 6 Water Softner 0 Drink Ftn 0 Sery Sink 1 Soda Disp 2
Lavatory 7 Lndry Tray 0 Local Waste 0 Wait. St. 1 Shamp Sink 0 Coffee Maker 0
Toilet 7 Lndry Stndp 0 Clothes Wshr 0 Ice Chest 2 Flr/Wst Sink 0 Int Grease Trap 0
Res. Sink 0 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 1
Bar Sink 0 Dishwasher 1 Beer Tap 0 Sculry Sink 1 Wash Ftn 0
Water Heater 1 Sump Pump 0 Dent. Oper. 0 Hand Sink 1 Urinal 2
Site Drain 15 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 1
Use /Nature
of Work RESTAURANT INTERIOR/ EXTERIOR PLUMBING
Size Material Type # Conn.Type
Sanitary Sewer 4" Plastic Lateral 1 Relay
0
0
0
0
Storm Sewer 0
0
0
0
0
Water Service 1 -1/2" Copper Lateral 1 Relay
0
0
0
0
Date 4/17/02 Type Underground Inspector WJ (Chip) Callies approved
Date/Time requested: 4/18/02 09:21 AM Notice Type: FC Telephone Number:
Access:
Ready Date/Time: 4/18/02 09:21 AM Requested By: JIM'S PLUMBING
0 Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid
----- - - - - -- --- - - - - --
7f-C
/ale/ ilke. ass
eAta-4-
�
r
3 z
/1 1 444. a Gat •'=X'O r
�e b ' S _ _
a�
G . '•- _ v,. s Ic- 11/
,tA)c-4-. st.91--Co..„2 tti4A<-14611.
— - - -
< (' < 4e, II r, w �l o r�� L 4 . C eg k; 1M� u
HVAC Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94182 Create Date 05/08/2002
Owner PRODUCTION INC C & J FOOD Contractor CONDON TOTAL COMFORT
Category 512 - Ind. & Comm -Both Plan
Fuel 11 Gas Oil J Electric 1 Solar ( 1 Solid Value $93,180.00
System n New 1 ❑ Replace I ❑ Other
Li] Forced Air u Radiant U Steam u A/C _J Vent
u Electric lJ Hot Water J Suppl. Li Con. Burner
Chimney Type Q Chimney A 0 Chimney B go Direct Vent 0 Not Applicable
Heat Loss 0 As Approved 0 Existing 0 Not Applicable Value 0
BTU Rate go As Per Plan 0 Variable 0 Other Value
Use /Nature COMM/ Install HVAC system for new restaurant.
of Work
Inspections:
Date Type Inspector
Date/Time requested: Notice Type: Phone Number:
Access:
Ready Date/Time: Requested By:
0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid
Safety and Buildings
2331 SAN LUIS PL STE 150
GREEN BAY WI 54304
TDD #: (608) 264 -8777
I seonSIn www.commerce state.wi.us /sb
www.wisconsin.gov
Department of Commerce
Scott McCallum, Governor
Philip Edw. Albert, Secretary
March 28, 2002
CUST ID No.261929 ATTN: Buildings & Structures Inspector
DEAN SCHULZ OSHKOSH INSPECTION
EXCEL ENGINEERING INC 215 CHURCH AVE
100 CAMELOT DR • PO BOX 1130
FOND DU LAC WI 54935 OSHKOSH WI 54902 -1130
PERMISSION TO START CONSTRUCTION Identification Numbers
Transaction ID No. 718117
SITE: Site ID No. 642002
C &J Restaurant Please refer to both identification numbers,
280 S Koeller Rd above, in all correspondence with the agency.
City of Oshkosh, 54901
Winnebago County
FOR:
Object Type: Building Regulated Object ID No.: 832406
Class of Construction: 8 Wood Frame - Unprotected; New Plan; 6,910 Project Sq Ft; 1 Story Bldg; Occupancy: Assembly
The Department of Commerce has received construction plans for review for the subject project, submitted in
accordance with the provisions of Comm 50.12 or Comm 50.13, accompanied by the owner's request to begin
construction work on the Footings and Foundations prior to Departmental review and approval.
This letter will serve as the department's permission to the local building officials to allow construction of the
Footings and Foundations, only, for the subject project prior to review and approval by this department
NO REVIEW OF THE SUBMITTED DOCUMENTS HAS BEEN UNDERTAKEN BY THE
DEPARTMENT AT THIS TIME FOR CODE COMPLIANCE.
In accordance with the provisions of the owner's signed request to begin construction prior to departmental review
and approval, the owner will be required to make any changes after the plans have been reviewed, and to remove or •
replace non -code complying parts of the foundations and/or footings.
Prior to the start of construction, all applicable building permits should be obtained from the local authorities having
jurisdiction in accordance with local laws and ordinances. Nothing in this approval limits the power of
municipalities to make, or enforce, additional or more stringent regulations, providing the regulations do not conflict
with this code or any other rule of the department, or law.
DEPARTMENT CONDITIONS
1. If this project is in an unsewered area, a sanitary permit must be obtained prior to the issuance of a local building
permit.
2. This permission is only for footing and foundation work. Construction of the remainder of the building shall not
take place prior to departmental review and conditional approval of the construction plans.
3. If this construction project will disturb 5 or more acres of land, an Erosion Control Notice of Intent shall be filed
with the department.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or
submitting additional information.
DEAN SCHULZ Page 2 3/28/02
Sincerely,
Pa
Karla Parker
Customer Service Representative , Integrated Services
(920)492 -5601 , M -F 7:45 am - 4:30 pm
Icparker@commerce.state.wi.us
cc: Peter R Ochs , Building Inspector, (920) 929 -3167 , Friday, 7:45 a.m. - 4:30 p.m.
Dean Schulz , Excel Engineering Inc
C &J Food Production Inc
Safety and Buildings
2331 SAN LUIS PL STE 150
GREEN BAY WI 54304
TDD #: (608) 264 -8777
/sco_ nsIn www.commerce.state.wi.us /sb
www.wisconsin.gov
Department of Commerce
Scott McCallum, Governor
Philip Edw. Albert, Secretary
April 03, 2002
CUST ID No. 261929 Fee Required $ 750.00
Fee Received $ 700.00
DEAN SCHULZ Balance Due $ 50.00
EXCEL ENGINEERING INC
100 CAMELOT DR Make Checks Payable To
FOND DU LAC WI 54935 Commerce.
WiSMART code: 7648
REQUEST FOR ADDITIONAL INFORMATION
SITE:
C &j Restaurant Identification Numbers
280 S Koeller Rd Transaction ID No. 718117
City of Oshkosh, 54901 Site ID No. 642002
Winnebago County Please refer to both identification numbers, above,
FOR: in all correspondence with the agency.
Object Type: Building Regulated Object ID No.: 832406
Class of Construction: 8 Wood Frame - Unprotected; New Plan; 6,910 Project Sq Ft; 1 Story Bldg; Unsprinklered;
Occupancy: Assembly
The submittal described above has been placed on HOLD and the review and approval is pending subject to receipt
of the ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt of the additional
information and/or revised plans, the plans will be reviewed for compliance to applicable Wisconsin Administrative
Codes and Wisconsin Statutes.
The following must be corrected/revised and accompany the resubmittal:
Key Item(s)
• COMM 52.012(3)(a) and (b) The storage rooms shown are not subdivided into 100 square foot areas by
fire- resistive construction having a minimum 30- minute rating and doorways protected by at least 20- minute fire
door assemblies. This requires them to have automatic sprinkler protection. An alternative would be to isolate
the storage area into rooms not exceeding 1,500 square feet with at least 1 -hour fire- resistive construction, a
minimum 3/4 -hour protection of openings, and a properly wired detection and alarm system. Storage room 113
shall comply with the requirements of this code section. Please submit revised plans showing compliance.
• COMM 55.02(2m)(a) This frame constructed assembly hall must be located at least 20 feet from adjoining
property lines and any other building on the property. Plans indicate south wall of the building is less than 20'
from the property line. Please submit revised plans showing compliance.
Also Address
• COMM 51.151 Provide at least 2 properly distributed exits or exit accesses, with out swinging doors, for rooms
and spaces with an occupant load in excess of 25 persons. Bar /seating area requires a second exit, or
elimination of 1 booth. Please submit revised plans showing compliance.
• COMM 50.12 — Submission of revised plans and/or additional information requires additional fees of $150.00.
Please include a copy of this letter with your re- submittal.
Send your re- submittal into the address listed above, unless otherwise noted, and the department will review the
resubmittal within 5 working days of receipt date. A copy of this letter-is to accompany the resubmittal.
DEAN SCHULZ Page 2 4/3/02
If the above requested information and/or plans are not received within 30 days of the date of this correspondence,
this submittal will be returned denied. No fees will be refunded, and a new fee, application form, and submittal of
plans /specifications will be required should you desire to continue with this project. The code in effect at the time of
new submittal would apply.
Sincer-
•
4W" Or"
Jo !J Wotrub
P1. n Reviewer , Integrated Servic s
(920)492 -6500 , 7:45 am - 4:30PM
jwotruba@commerce.state.wi.us
cc: Peter R Ochs , Building Inspector, (920) 929 -3167 , Friday, 7:45 a.m. - 4:30 p.m.
Oshkosh Inspection
C &j Food Production Inc
•
Safety and Buildings
2331 SAN LUIS PL STE 150
GREEN BAY WI 54304
TDD #: (608) 264 -
ISCOnSIn 264-8777
www.commerce.state.w -8777
www.wisconsin.go•
Department of Commerce
Scott McCallum, Governor
Philip Edw. Albert, Secretary
April 22, 2002
CUST ID No.261929 ATTN: Buildings & Structures Inspector
DEAN SCHULZ OSHKOSH INSPECTION
EXCEL ENGINEERING INC 215 CHURCH AVE
100 CAMELOT DR PO BOX 1130
FOND DU LAC WI 54935 OSHKOSH WI 54902 -1130
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 04/22/2004 Identification Numbers
Transaction ID No. 718117
SITE Site ID No. 642002
C &j Restaurant Please refer to both identification numbers,
280 S Koeller Rd above, in all correspondence with the agency.
City of Oshkosh, 54901
Winnebago County
FOR:
Object Type: Building Regulated Object ID No.: 832406
Class of Construction: 8 Wood Frame - Unprotected; New Plan; 6,910 Project Sq Ft; 1 Story Bldg; Unsprinklered;
Occupancy: Assembly
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in
chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements.
The following conditions shall be met during construction or installation and prior to occupancy or use:
COMM 50.12 — Your revised plans and additional information have been received and re- reviewed.
Submit
• COMM 50.12 This review does not include heating, ventilating or air conditioning. The owner should be
reminded that HVAC plans, calculations, a completed SBD -118 application form and appropriate fees are
required to be submitted for review and approval prior to installation.
• Submit, prior to installation, one (1) set of properly signed and sealed truss plans, a completed SB -118
application form including this transaction number and signed by the building designer, and $100 submittal fee
to Safety & Buildings, P.O. Box 7162, Madison WI 53707 -7162.
A copy of the approved plans, specifications and this letter shall be on -site during construction and open to
inspection by authorized representatives of the Department, which may include local inspectors. All permits
required by the state or the local municipality shall be obtained prior to commencement of
construction /installation/operation.
In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should
conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review
shall relieve the designer of the responsibility for designing a safe building, structure. or component.
Inquiries concerning this correspondence may be made to me at the telephone number listed below. or at the address
on this letterhead.
•
DEAN SCHULZ Page 2 4/22/02
Sincerely, Fee Required $ 950.00
Fee Received $ 900.00
Balance Due $ 50.00
John J Wotruba Make Checks Payable To
Plan Reviewer , Integrated Services Commerce.
(920)492 -6500 , 7:45 am - 4:30PM WiSMART code: 7648
jwotruba@commerce.state.wi.us
cc: Peter R Ochs , Building Inspector, (920) 929 -3167 , Friday, 7:45 a.m. - 4:30 p.m.
C &j Food Production Inc
E'XCEL
ENGINEERING INC.
Thursday, April 04, 2002
RECEIVED
APB 1. 2 2002
Wisconsin Department of Commerce BAFETY & BLDOS• DM
John Wotruba
2331 San Luis Place #150
Green Bay, WI 54304
RE: C & J Restaurant
Transaction #: 718117
Dear Mr. Wotruba:
Please find enclosed five copies of revised plans, check in the amount of
$200.00 and a copy of your additional information letter dated April 3, 2002. We
have separated the storage room into 100 sq. ft. compartments or Tess. We have
moved the building 3' to the North. Our setback from the South lot line is now
20'. We have eliminated a booth in the bar area.
Our intentions were to comply with all of your comments. Please call with any
questions.
• ce -ly, .
xcel gine-ri / ',
/ A-
Dean J /1 I. , R.A.
DJS /sjs
cc: Fox Cities Construction, Keith Decker
Enclosures
F:1job files�202130 Fo e - Citi C &J fiesta rant \c rres \Wotruba 040402.doc
100 CAMELOT DRIVE - F�ND �U LAG, W� 5495 PHONE: (920) 926 -9800 FAX: (920) 926 -9801
Safety and Buildings
2331 SAN LUIS PL STE 150
GREEN BAY WI 54304
TDD #: (608) 264 -8777
N*sconsin www.commerce.state.wi.usisb
www.wisconsin.gov
Department of Commerce
Scott McCallum, Governor
Philip Edw. Albert, Secretary
April 30, 2002
CUST ID No.259120 ATTN: Buildings & Structures Inspector
ARTHUR WARREN OSHKOSH INSPECTION
CONDON TOTAL COMFORT INC 215 CHURCH AVE
PO BOX 184 PO BOX 1130
RIPON WI 54971 OSHKOSH WI 54902 -1130
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 04/30/2003 Identification Numbers
Transaction ID No. 723424
SITE Site ID No. 642002
C &j Restaurant Please refer to both identification numbers,
280 S Koeller Rd above, in all correspondence with the agency.
City of Oshkosh, 54901
Winnebago County
FOR:
Object Type: HVAC System Regulated Object ID No.: 847146
Grease Hood Included
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in
chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements.
The following conditions shall be met during construction or installation and prior to occupancy or use:
A copy of the approved plans, specifications and this letter shall be on -site during construction and open to
inspection by authorized representatives of the Department, which may include local inspectors. All permits
required by the state or the local municipality shall be obtained prior to commencement of
construction /installation/operation.
In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should
conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review
shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead.
Sincerel • Fee Required $ 470.00
Fee Received $ 470.00
Balance Due $ 0.00
Jo , J Wotruba
Plan Reviewer , Integrated Services WiSMART code: 7648
(920)492 -6500 , 7:45 am - 4:30PM
j wotruba(a"2commerce.state.wi.us
cc: Peter R Ochs , Building Inspector, (9201 929-3167 . Friday, 7:45 a.m. - 4:30 p.m.
C &j Food Production Inc
Dannhoff, AIIyn J.
From: Dahmen, Randy [rdahmen @commerce.state.wi.us]
Sent: Monday, April 29, 2002 4:42 PM
To: 'Dannhoff, Allyn J.'
Subject: RE: Oriental Restaurants - Personal At Table Grills/
Will the food be "grease laden "(animal oil, grease, corn oil, butter) etc.?
Will the area of the grille be over 4 sf? If so 64.67 requirements apply,
which includes the suppression system.
I can't believe anyone who says they will cook without oils - -they have to
use oils in order to keep the meat from sticking to the grille. If they
don't, the meat is releasing the oils (ie. hamburgers, brats etc.) Their
pulling your leg for getting out of a $2,000 suppression system
Randall R. Dahmen, PE
Commercial Bldg Consultant, Plan Reviewer, Inspector
WI Dept. of Commerce, Safety & Buildings Division
P.O. Box 7162
201 W. Washington Av.
Madison, WI 53701-7162
Phone (608) 266 -3162
Fax (608) 267 -9566
email: rdahmen @commerce.state.wi.us
> Original Message
> From: Dannhoff, Allyn J. [SMTP:adannhoff @ci.oshkosh.wi.us]
> Sent: Monday, April 29, 2002 4:22 PM
> To: Randy Dahmen (E -mail)
> Subject: Oriental Restaurants - Personal At Table Grills/
>
>
> We have a new oriental restaurant being built that will have 2 grills that
> people sit around and the chef prepares the meal as part of their dining
> experience. The HVAC contractor has told me these have down draft exhaust
> systems similar to a Jen -aire. I am looking for advice, direction on what
> is required for fire extinguishing /suppresion systems for this type of
> equipment. A regular grill generally has a hood over it with an
> extinguishing system, how does the state code address these types of
> systems?
>
> Additionally this same restaurant will have a Mongolian Grill, a large
> round
> grill that a chef prepares food for patrons after they have selected their
> ingredients. The owner claims they will not be grilling meats at this
> grill, however, I presume they will or may use oils when cooking the food.
> Is an extinguishing system required if they do not cook meat or use oils?
> Is the extinguishing system required if they only use oils when cooking,
> but
> do not cook meat?
>
> Thanks for your help.
1
City of Oshkosh
Inspection Services Division
215 Church Avenue
PO Box 1130
OJHKOI Oshkosh WI 54903 -1130
ON THE WATER
Fax
To: I From Allyn Dannhoff
Catle ;/c Cf FrN S Dept: Director of Inspection Services
Fax: Z Z r g 700 Fax: (920)236 -5084
Phone: Phone (920)236 -5045
Re: E - Mail: adannhoff@ci.oshkosh.wi.us
Date: CC:
Pages: ( ) Including the cover sheet
❑ Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle
• Comments: //' �/ /
e c9. ( ,(, o C( — / � r` c4 kt# P-
.4- 'rte !( elm 18' a
CAP r C / r
l:
4,€ Cv-e- P Gr1 4 c��T r' 6 i'i' S C� /`F C.. c e . Q �` iGcc� -ie r-r `a/ r"0
w
Ur4acues rho a ptt-of edece }per !a 7(J`�'
-1 Dr coal topvt
A XE
aut
64.67
In the above formulas, A = Horizontal area of the hood.
Exhaust rates may be reduced below those given in the code if the particular hood under
consideration is listed for exhausting at a reduced rate. The department recognizes Underwriters'
Laboratory fire protection equipment directory listings.
Note: Q equals the exhaust air in cubic feet per minute; A equals the area of the hood over the grease- producing
equipment in square feet; V equals the velocity in feet per minute; and L equals the total length in feet of the
cooking appliance being ventilated, and measured parallel to the front edge of the appliance.
(c) Materials. Hoods shall be constructed and supported by steel not less than .0478 inch
U.S. standard gage (No. 18 manufacturers standard gage) or stainless steel not less than
.0359 inch U.S. standard gage (No. 20 manufacturers standard gage) or other materials of
equivalent strength, fire and corrosion resistance.
Note: The Department of Health and Social Services (DHSS) may have additional requirements for materials in
commercial food preparation areas. For more information, contact the DHSS Environmental Sanitation Unit.
(d) Seams. All seams and joints shall be liquid- tight.
(e) Grease - removal devices. Approved grease extractors, grease filters or other grease -
removal devices shall be provided.
�� (f) Exposed hood surfaces. Hood surfaces and exposed exhaust ducts within 18 inches of
combustible material shall be protected as specified in sub. (5) (f).
(g) Concealed hood surfaces. Hood surfaces that are concealed by or recessed into adjoining
construction shall be protected as specified in sub. (5) (f).
(h) Double -wall hoods utilizing outdoor air. When hoods are connected to ducts supplying
outside air, performance data shall be submitted.
Note: Double -wall hoods provided with a supply of outdoor air conserve energy.
(5) EXHAUST DUCTS FROM HOODS.
(a) Design. All ducts shall lead, as directly as possible, to the exterior of the building without
forming dips or traps which collect residues. Ducts exposed to the exterior shall be protected
with a suitable weatherproof coating.
Note: Temperatures in excess of 2000 °F. may be experienced within ducts in the event of fire. A means of
expansion of long ducts should be considered.
(b) Materials. Ducts shall be constructed of and supported by steel not lighter than
.0598 inch U.S. standard gage (No. 16 manufacturers standard gage) or stainless steel not
lighter than .0478 inch U.S. standard gage (No. 18 manufacturers standard gage) or other
materials of equivalent strength, fire and corrosion resistance.
(c) Seams and joints. All seams and joints shall be liquid- tight.
(d) Clean -out openings. Accessible clean-out openings at the sides of ducts shall be provided
at each change of direction of the duct for inspection and servicing.
(e) Interior ducts. Ducts shall not pass through required fire walls or partitions.
(f) Duct enclosure.
1. A grease duct that penetrates or passes through any ceiling, wall or floor shall be
completely enclosed from the point of penetration to the outlet terminal.
2. The duct enclosure shall meet one of the following requirements:
a. The duct shall be enclosed in a noncombustible 2 -hour rated fire - resistive enclosure.
- 2001- 64 -88-
04,03/2002 17:33 FAX 19209269801 ExceiEngineering 201
( XCEL
ENGINEERING INC.
100 Camelot Drive
Fond du. Lac, WI 54935
Phone: (920)426 -9800 Fax: [9201- 926=9g0i
E - mail: info@excelengineer.com
FAX TRANSMITTAL
TO: FAX # 920 -235 -87110
PHONE # 020 -23s -8008
COMPANY Fax Cities Construction Corp.
ATTN: Keith Decker
FROM: Dean Schulz
DATE: April 3, 2002
JOB #: C&J rest.
RE: call me when you gel a chance
Number Of Pages Sent (Including Cover Sheet) 4
Hard Copy to Follow VIA Mail: ❑ Yes No
cc:
This facsimile transmission is intended only for the addressee named above. It contains information that is
privileged, confidential or otherwise protected from use and disclosure. If you are not the intended recipient,
you are hereby notified that any review, disclosure or copying of this transmission, or the taking of any action
in reliance on its content, or other use is strictly prohibited. If you have received this transmission in error,
please notify us by telephone immediately so that we eau arrange for its return to us. Thank you for your
cooperation,
Documend 3/9101
04/03/2002 1T :33 FAX 19209269801 ExcelEnelneerlag 1ij02
04/03/02 RED 11:13 FAZ 020 492 5604 COMMERCE 001
Safety one 9u dlig5
2331 SAN LUIS PL $TE'150
GREEN BAY Wl 54304
Ntisconsin TOO it:: (608) 254-37T7
wew.cam marts atate.ve.uaiso
Department of Commer^e "
Stet[ McCollum, tsevernor
Phirtp Edw- Albert, Secretary
April C?. 2002
CIJST 1D No. 261929 Fee Required $ 750.00
Fee Received S 700.00
DEAN SCIMI.z - Balance Die $ 50.00
EXCEL ENGINEERING WC
100 CAMELOT Din Make Cheeks Payable To
FOND DU LAC WI 54935 Cearanerce.
Wi$MART code: 7648
REQUEST FOR ADDITIONAL INFORMATION
SITE;
Cd:J Restaurant
Identification Numbers
280 5 Foeller 114 Transeetfoe ID No. 718117
City of OShkosh, 54901 Site ID No. 642602
Winnebago COQ Please refer to both identification numbess, above
Object in all co�sponderrce with the totem --
] Type: Building Regulated Object ID No.: 831406
Class of Construction: 8 Wood Frame - Unprotected: New Plan; 6,910 Project Sq Ft 1 Story Bldg; linsprinklered;
Occupancy. Assembly
The subnuttel described above has been placed on BOLD and the review and approval is pending subject to receipt
of the ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt of the additional
information and/or revised plans, the plans will be reviewed For compliance to applicable Wisconsin Administrative
Codes and Wisconsin Statutes.
The following must be corrected/revised and accompany the =submittal:
Key Items)
• COMM 52.012(3)(0 and (b) The storage rooms shown are not subdivided into 100 square foot areas by
fire - resistive con:tr action having a minimum 30- minute rating and doorways protected by at least 20- minute tae
door assemblies. This requires theta to have automate sprinkler protection An alternative would be to isolate
the storage area into rooms not exceeding 1,500 square feet with at least 1 - hour fire-resistive construction, a
minim= 3/4 -hots protection of openings, and a property wired detection and alarm system. Storage room 113
t comply with the requirements of this cock section. Please submit revised plans sbowing compliance.
• COMM 55.02(2mX0 This frame constructed assembly hull must be located at least 20 feet from adjoining
property lines and any other building on the property. P1aa, indicate south well of the building is less than 20'
from the property line. Please submit revised plans showing compliance.
Also Address
• COMM 31.151 Provide at least 2 properly distributed exits or exit accesses, without swinging doors, for rooms
and spaces with an occupant load in excess of25 persons. Bar /seating area requires a second exit. or
elimination of 1 booth. Please submit revised plans showing compliance.
• COMM 50.12 - Soemicsion of revised plats and/or additional infornotion requires additional fees of515
Please include a copy of this letter with your re- subminei
Send your re- submittal into the address listed above, unless otherwise noted. and the depatnacnt will review the
tesubutiteal within 5 working days of receipt date. A copy of this letter is to accompany the resubrnitt il.
04/03/2002 17 ;33 FAX 19209269801 ExcelEngineering a03
04/03/02 WED 11:13 FAX 920 492 5604 COMMERCE a 002
DEAN SCHULZ Page 2 4/5/02
If the above requested information and/or plans are not received within 30 days of the date of this correspondence,
Ibis submittal will be returned denied No fees will be refunded, and a new fee, application form., and submittal of
pleas/specifications will be required should you desire to continue with this project. The code in effect at the rime of
new submitiat would apply,
SallerAly
41111 "AMP%
1. 1Yvo.
P1 Reviewer , Integrated Servi
(920)4924.500 , 7.45 an - 4 :30PM
j wotiubsecommerce.state.wi.us
et: Peter Q Ochs . Building Inspector, (92O) 929 -3167 , Friday, 7:45 t;.m. - 4:30 p.m,
Oshkosh Inspection
C&j Food Production Inc
•
•
•
04/03/20e2 17:33 FAX 192092e9a01 ExcelEngineerlag i,?1,- 0 4_,......
1 ,
./....._____ 23'-0'
___
I
-- ... ' - . -9.,(9 '-''' ' • Tar
, . 9. •
I .
• ..e9 ,
- • - 7" - -
... 411 t: ail Y.A
:---
• C / t I 1
i 15
a_ • i
pip
.9, . __ _ :__.,4■■■•i'..,....___....,••■••■*■,..p.... ....„______,.___ %) (ft 9
1 i
I I
‘.ent
—...
. •
_____
,.:
1,_____________
.. tn i TIN . . J.Q. ,
ILI ' '
1 1
- 1 - 1 ° , E r=5„)Iss1 5. - - - -4-1 '11.iT ".
. 5074 51 OF NALL 7 9
1 I
(0 min.
• , 1
• 7A51—E
N.-...,_ji
,i;
4.-e ,, 3/4" i
i tA
23'-4 I/4" 3 I/2"
i
. .,....
r.o. i
I _ ..- ...
•
i i ,
\ It i ;r1 e'l 7 - --
i t
Et I ThEit_f_fr 1
I 9" 41-1 1.. 1In ,
D.,
,
2 I \ rr )— '-' - it ff.
IL, ..42 t 7.1 - ..----' j /2 . 1 i I
. 1 r '.. 12 ' - I \ 1 PIRMI 1 99999/
-
9 I .. 9 • 9,9: ' 14 . 9 9
ill 2b LoN95 Moor, Ae
1 • :•.•...
• N NISEX -
. t i a T '. t I , : 1: 1 1- 17 . 1.1: _ •
j: ..'",,,,:
wo‹..3 el
n 11 :. ... !MI 1
• ...J '
tn
1= OLar , rS.S. ON AS i
I )1 .. Fet: ''' - 1 .....: ------ -- . ------------.k , 11 0 ' '
al - .. . sc..•ame I 1 - rearpt TABLr_ • ,0 _ _______ _________.
I = -
7
' . • A5c7vE .ii.' I-9 .7A3V..z
c99 T C.AILPET
1 = ,
2 [
ABA t
Hs -------------I- - ' M. NCv01.1 N MBEs n I ' a Iri
3 1
, El
A4.0 • ( t
,1 IT 9
....___„/
I II / 111-- . il
IP 1
t.o5 s 1 al 9 / I Milk H
V27 -c,---„ -
,... \
) - r--------
_ -- il
J EN Suph II
II IMO
I i
1 I II
li
1
, 0 0 I)
II
0 0 II I I
I
1 ___ it 1
1 •-___L e .,,,,,
,-
,, , , ,,NTER.log
I AALL I..cfnATIONS I
I 4 I• ) 1 I 1/4/:5,2 ,
I; PIO - - ...pivt I
IQ I MF' 1 TI , 1 _," t!)--- ■ lir) li 1/ 70 55 YERIFIE
ol/ 5EATINS P1-AN ' .--
iLL 1 1
(,) I CAP: 124 P3P-Scims 9
I <
2
, ,
,.
ii ,
, 1: i sALA0
1
- 45.0 5 .111
. 4...—.7: . ...:
11
, - e N. '''• ,. \ ' .A '',
16,1i
• _
--------1--VAr*"--1
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Building Wiring
Service ❑ New O Change 0 Temp 0 N/A J Type 0 Overhead • Underground O N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02** Garbage Disposal, Dishwasher, Fan or blower, Furnace, NC, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 07/26/2002 Type Re Final Inspector Kevin Benner not approved
Re- inspect for the neon installation.
INTERIOR NEON WRONG. EXT OK. LABELING & BKR LOXS.
Date/Time requested: 07/26/2002 10:37 AM Notice Type: Phone Number:
Access:
Look for Kelly from Appleton signs
Ready Date/Time: 07/26/2002 10:37 AM Requested by:
O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Date 08/01/2002 Type Final Inspector Kevin Benner not approved
Exterior signage approved, interior signage not corrected.
Date/Time requested: 08/01/2002 00:00 AM Notice Type: Phone Number:
Access:
Met Matt G. from E.C. on site
Ready Date/Time: 08/01/2002 00:00 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Building Wiring
Service ❑ New O Change ❑ Temp O N/A Type O Overhead • Underground 0 N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02 ** Garbage Disposal, Dishwasher, Fan or blower, Furnace, A/C, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 07/15/2002 Type Final Inspector Kevin Benner not approved
See Field Notes
Date /Time requested: 07/10/2002 01:23 PM Notice Type: Phone Number:
Access:
Ready Date/Time: 07/15/2002 00:00 AM Requested by:
O Reinspect Fee O Fee Wavied ❑ Reinspect Fee Paid
Date 07/18/2002 Type Re Final Inspector Jon Fischer not approved
1) Breaker locks. 2) Panel space. 3) Neon signs.
Date/Time requested: 07/16/2002 07:32 AM Notice Type: Phone Number:
Access:
Meet John Fisher on site to turn the inspections over to him
Ready Date/Time: 07/16/2002 07:32 AM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Electric Permit Work Card
Job Address 280 S KOELLER ST Permit Number 94012 Create Date 04/30/2002
Owner PRODUCTION INC C & J FOOD Contractor SOLAR ELECTRIC SERVICES INC
Category 642 - Commercial -New Building Wiring
Service ° New ° Change ° Temp 0 N/A Type 0 Overhead • Underground ° N/A
Volts 120 / 208 Circuits 0 Fixtures 0
Amps 800 Switches 0 Receptacles 0
Fee $300.00 ❑ Value $50,000.00
Appliances *Added 5/17/02" Garbage Disposal, Dishwasher, Fan or blower, Furnace, A/C, Electric Sign, Motors
Use /Nature COMM/ Wire new restaurant.
of Work
Inspections:
Date 05/24/2002 Type Rough In Inspector Kevin Benner approved
Date/Time requested: 05/22/2002 10:41 AM Notice Type: Phone Number:
Access:
Ready Date/Time: 05/22/2002 10:41 AM Requested by:
° Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid
Date 06/03/2002 Type Service Inspector Kevin Benner approved
FAXED & MAILED TO WPS 6/3/02
100KAIC MCB
Date/Time requested: 05/31/2002 12:43 PM Notice Type: Phone Number: 410 -5174
Access:
Jim
Ready Date/Time: 05/31/2002 12:43 PM Requested by:
0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid