Loading...
HomeMy WebLinkAboutStructural (joist girder) - 06/09/1987 � L� o cS-7 DEPARTMENT OF INDUSTRY, LABOR AND HUMAN RELATIONS SAFETY & BUILDINGS DIVISION FILE NO E -j BUREAU OF BUILDINGS AND STRUCTURES PLAN Ntffiai— inI 201 E. WASHINGTON AVE. VOLUME P.O. Box 7969 PLAN EXAMINATION LETTER MADISON, WISCONSIN 53707 {(( .,, Note: This Preprinted Plan Review letter is being used at the discre- DATE: �.i f�.a 7 7 tion of the plan examiner to expedite the plan review. This form serves as the review correspondence. OccupancrarNA Owner G-19 SR E I Dit e ? Location I'LJ "41- 141'' C'. tve/ 1N-P . k VA v i ,�} • t\-4/ County 1 a tO 0 Municipalit 11' 2 ) ) 4 E- go > C !v!Z Supervising Professional V X - 7 ►' 1011.- M (� 6 Plans have been reviewed for compliance with the important code requirements in Chapters ILHR 50 through 64 of the rules of the Department. Thy U fl ) ML- 0CA ST 61t -g) plans are: X\ l CONDITIONALLY APPROVED WITHHELD 1 NOT APPROVED If the plans are stamped "CONDITIONALLY APPROVED" construction may proceed, but all items that are required to be changed by this letter must be corrected before commencing that part of the work. You are advised that the owner as defined in Chapter 101.01(2)(i) of the Wisconsin State Statutes is responsible for all code requirements not specifically cited. l I The building will be inspected during and after construction. The owner shall notify the state building inspector and the local building inspector before taking possession of the building. ILHR 50.15 EVIDENCE OF APPROVAL. The architect, professional engineer, designer, builder or owner shall keep at the building, one set of plans bearing the stamp of approval. This plan has not been reviewed for compliance with Chapters ILHR 82 through 86, the Plumbing Rules of the Department. THIS BUILDING HAS BEEN CLASSIFIED AS N I TT K/. CONSTRUCTION. SPRINKLERED UNLIMITED AREA COMMENTS: Plans for the following shall be submitted to this office and approved prior to construction of that component. ❑ Trusses ❑ Precast Concrete ❑ Heat & Vent Systems y ❑Illumination ❑ /� Area Code State Inspector - Region ./ t.- 1-4 ` Phone Local Inspecto - �L �J }-t PLAN EXAMINER Phone kG� T`TV 5 I Yom.. • - 9 S71ctX "t, e Apt- STe 1 hk .-> >c I 0‘ 00 Pb ea. 10 51.1 1 54W e7P9 } u1t 3o7 - 031 SBD -5686 (R. 06/85) 1AT 11%) State of VV iseonsin \ Department of Industry, Labor and Human Relations SAFETY & BUILDINGS DIVISION April 29, 1997 201 E. Washington Avenue File Mo. E-118135 P0. Box 7969 Madison, Wisconsin 53707 Mark Dillennurg Foth & Van Dyke A Assoc., Inc. 2737 South Ridge Road, Pox 1 Green Bay, WI 54307-9012 CY Retail Store Building Don Callahan--Shopko Stores, Inc., Owner Hey. "41-141" at Menard Avenue Oshkosh, Winnebago County Plan Number 83-10-0439-C Mark Dillenbure, Supv. Arch. I 213 writing ia reference to your steel joist girder plan aubmittel received on April 6, 1987 and reviewed on April 22, 1987. Plan approval for the referenced project 13 withheld pending receipt of additional information and/or revised plans. If the additional information and/or plans Are not received prior to June 15, 1987, pit will be stamped "Not Approved" and returned. Approval is withheld because of the following code violations. ILHR 5 The joist girder plans which you submitted did not include the "plans" for the indivicual joist girders. Those plans are required to identify the configuration of the joist girder with member sizes shown to correspond with the signed and sealed calculations which you have already submitted. At least four signed and seale sets of joist girder plans (grder G-1 through G-18, including revised 0-10 and G-15A) shall be submitted for review and approval. Sincerely, cc: Shopko Storea, Inc. P.O. Box 19060 Green Bay, WI 54307-9060 James B. Smith Steel Joist of Indiana, Inc. Lead Worker—Plan Review 2341 S. 30th Street, Box 5057 (608) 265-0251 La Fayette, IN 47903 JB 3:MO2302 cc: R-3 Ochs, phone 414 -887-7890, Friday Oshkosh 8u1/din Inspector e SBD-5850