Loading...
HomeMy WebLinkAbout2005-Electric (bleachers) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 OSHKOSH WI 54903 -1130 ON THE WATER Issue Date 1/10/05 Compliance Date 2/9/05 Compliance No Address 110 N SAWYER ST Name Address City State Zip Code Sent to IJ Owner LOURDES ACADEMY 110 N SAWYER OSHKOSH WI 54901 -0000 J Required for Occupancy I Occupancy Introduction While conducting a routine Final Re- Inspection I noticed that the bleachers were installed. While 1 was on site a staff member tried to operate the bleachers and the circuit breaker tripped. The following is the violations that I noticed when I inspected the installation. Item # 1 Code M.C. 11 - 32 Compliance No Compliance Date 02/09/2005 IMMEDIATELY Description No electrical equipment shall be installed, altered, renewed, replaced, or connected without first procuring a permit. (Only local licensed electrical contractors can procure a permit). This pertains to the wiring of the bleachers that was conducted by the 1/10/05 bleacher manufacture. Last Updated Item # 2 Code NEC 400.8 Compliance No Compliance Date 02/09/2005 IMMEDIATELY Description Flexible cord shall not be used as substitute for fixed wiring. 1/10/05 Last Updated Item # 3 Code NEC 110.3(b) Compliance No Compliance Date 02/09/2005 IMMEDIATELY Description Listed or labeled equipment shall be installed and used in accordance with any instructions included with the listing or labeling. (Cord connector for the bleacher power supply) 1/10/05 Last Updated Item # 4 Code NEC 210.23 Compliance No Compliance Date 02/09/2005 IMMEDIATELY Description The total rating of any one cord- and -plug connected utilization equipment fasted in place, shall not exceed 50 percent of the branch circuit. (The bleachers are plugged into a multi - receptacle branch circuit and the bleacher Toad is greater than 50 1/10/05 percent of the branch circuit value) Last Updated 9811 Page 1 of 2 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH (/ ) DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 1/10/05 Compliance Date 2/9/05 Compliance No Address 110 N SAWYER ST Name Address City State Zip Code Sent to j Owner LOURDES ACADEMY 110 N SAWYER OSHKOSH WI 54901 -0000 Required for Occupancy Occupancy Introduction While conducting a routine Final Re- Inspection I noticed that the bleachers were installed. While I was on site a staff member tried to operate the bleachers and the circuit breaker tripped. The following is the violations that I noticed when I inspected the installation. Item # 5 Code Note Compliance Compliance Date 02/09/2005 Description Kevin Duffy of Ganther Construction requested that this correction notice be generated and faxed to him on 1/10/05. 1/10/05 Last Updated Summary To avoid any further inconveniences please correct the above noted violations immediately. Any questions or concems please feel free to contact me at 236 -5046. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 2/9/05 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. Signature �,1,/tiy�,.d Date [ 10(0 S Inspec b : evin Benner 236 -5046 kbenner@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: ✓4 Bldg GANTHER CONSTRUCTION 4825 CTY TRK A OSHKOSH WI 54901 -0 Elec EXCELLENCE ELECTRIC, INC. PO BOX 78 LITTLE CHUTE WI 54140 -78 u HVAC - Plbg - J Designer - _f Other 0 -0000 Li Inspector 9811 Page 2 of 2