HomeMy WebLinkAboutPlumbing #F2-07-0301-P (03/12/2001) City of Oshkosh
Inspection Services
It\10,11116„ 215 Church Ave., PO Box 1 130
Oshkosh, WI 54902 -1130
O.fHKO.IH FAX
236 -5049 (920) 236 -5106
ON THE WATER
March 12, 2001
Richard Kempinger, Architect
1928 S. Washburn St.
Oshkosh, WI 54904
Unified Catholic School (Lourdes addition)
Ref: Plumbing Plan Approval: 110 N. Sawyer St., Oshkosh, WI
Plan ID# F2 -07- 0301 -P
Dear Sirs,
Examination of the plumbing plans and specifications for this project has been completed. In
accord with Chapter 145, Wisconsin Statute, and COMM 81 through 85, Wisconsin Administrative
Code, the plumbing plans and specifications are approved contingent upon compliance with the
stipulation(s) noted below.
1. All horizontal building drain shall be served by a full size cleanout opening COMM
82.35
2. Building sewer shall be served by one minimum 3" undiminished stack COMM
82.31(lacking installation of alternate bid items)
3. Developed distance for branch drain shall not exceed point of vent for fixture trap per
COMM 82.31
4. Water heater temperature and pressure relief valve shall have an approved receptor
COMM 82.40 (mop basin is not approved as required receptor)
5. Required drain pitch shall be observed for drains according to load COMM 82.36
6. Maximum separation of building sewer cleanouts shall not exceed limits of COMM 82.35
7. Building sewer cleanout access shall be provided within 5 feet of foundation wall for all
sewers COMM 82.35 (including alternate bid items)
In the event installation of this plumbing system has not commenced within two years from this
date, this approval shall become void. A new application accompanied by full examination fees shall be
filed and an updated approval received before work may commence.
In granting this approval, the City of Oshkosh or its representative does not hold itself liable for
any defects in plans or specifications, plan omissions, examination oversight, construction or any
damage that may result in or after installation. The City of Oshkosh reserves the right to order changes
or additions should conditions arise making this necessary.
It shall be necessary for the installing plumber to obtain a plumbing permit from the City of
Oshkosh before proceeding with actual installation of this plumbing system or any of its parts.
Respectfully,
Richard Wood, Plumbing Inspector
03/08/2001 09:52 FAX 608 271 7284 ARNOLD AND O'SHERIDAN tj002 /002
le Ira .sc&c y v
0, =1tlllljl5 MAR 05 2001
1 J.
itrnGfd A C' ist'idan kW.
EAST CENTRAL WISCONSIN REGIONAL PLANNING COMMISSION
� ,� 132 Main Street Menasha, Wisconsin 54952 -3100 (920)751 -4770 FAX (920)751 -4771
March 2, 2001
Larry P. Randall
Arnold & O'Sheridan, Inc.
Madison, WI 53711 -2498
Dear Mr. Randall: East Central Review No. 2001 -038
Subject: East Central Comments — Sanitary Sewer Lateral Proposal
The East Central Wisconsin Regional Planning Commission, in accordance with Wisconsin
Administrative Code COMM. 82, s.82.20(4)(c), has reviewed the proposed sanitary sewer lateral
for the Unified Catholic school project located on Josslyn Street, City of Oshkosh, Winnebago
County.
East Central has determined the proposed development is within the Oshkosh Sewer Service
Area. This project is also consistent with the Sewer Service Areawide Water Quality
Management Plan elements.
A copy of this letter should be enclosed with the project plans sent to the Wisconsin Department
of Commerce and other appropriate review agencies for their review. If you have any questions,
please contact East Central.
Sincerely,
Harlan P. Kiesow
Executive Director
HPK/jwh
•
•
Member Counties: Calumet Marquette Menominee Outagamie Shawano Waupaca Waushara Winnebago