HomeMy WebLinkAbout1982-Building #81-12-6-B CITY OF OSHKOSH March 26, 1982 Richco Structures Rt. #3 De Pere, WI 54115 Attn: Mr. Bruce Bein Dear Mr. Bein: New dental clinic building 230 N. Sawyer St. Dr. Lynn Haen, Owner File #81- 12 -6 -B James E. Larson, architect Fox Cities Construction Corp. has provided this office with one copy of a roof truss drawing and computer printout for 13'4" span. Building plan . approval had previously been conditional approved. One condition of approval was that roof truss plans be submitted for approval as required under Ind. 50.12, Wis. Adm. Code. The purpose of this letter is to remind you of the requirements for submitting truss plans separately and not included with the building plans. Ind. 50.12(3) At least 4 complete sets of plans, which are clear, legible and permanent copies shall be submitted for examination and approval before commencing construction. Ind. 50.12(3)(b) All plans shall contain the name of the owner and the address of the building. The name and seal of the architect(s), engineer(s) or person(s) who prepared the plans shall be on the title sheet, in accordance with s. A -E 1.04(4), Wis. Adm. Code - registration seals. Ind. 50.12(5) A plans application form shall be included with the plans submitted to the department for examination and approval. Ind. 69.09 An examination fee is zequired with each submittal. Fees are the same as charged by D.I.L.H.R. (presently $37.80). Checks should be made out to the City of Oshkosh. Enclosed is a list of truss plan submittal requirements which is similar to that included with D.I.L.H.R. approval no. 800602 and other metal connector plate approvals. I hope this clearly states the data needed. When submitting, remember we also need drawings and data for the 11'4" span truss. Sincerely, EDWARD REIMER Chief Building Inspector CC: James Larson P. O. BOX 1130 • OSHKOSH, WISCONSIN 54902 a< Metal':Connector Plates Metal connector plates for wood trusses are approved for holding power and shear resistance only. Information required on all wood truss plans include the following: 1. Acceptable Unit Stresses. The allowable unit stresses published in the "National Design Specifications for Wood Construction, 1977 Edition" as recommended by the National Forest Products Association and its supplement Table 1 with listed exceptions as itemized in Section Ind 53.61(1)(a)1.a. through c. of the Wisconsin Building Code shall be used to determine allowable unit stresses. 2. An increase in allowable bending stress due to repetitive member use is acceptable as listed in the NDS Table 1 supplement. 3. Moment coefficients used in design of top bottom chord members shall be based on the assumption of no fixity at member end or joints due to plate connectors. Moment coefficients listed in TPI -78 with appropriate panel length adjustment factors are to be used in the design of the trusses. 4. The cumulative effects of short -time loads, such as snow, shall be considered in determining the duration of load. For snow load, no greater duration of load factor than 1.05 shall be used. 5. The metal plate connector must be properly identified on the plans. The gauge of the metal plate and its design capacity (in pounds per nail or pounds per square inch) must be shown on the plans. Section Ind 53.61(8) requires that light gauge perforated metal plate connectors be permanently identified with regard to their gauge and manufacturer. If a manufacturer's code is used to identify the plates, the code shall be explained on the plans. The design and use of metal plate connectors shall be in accordance with the requirements of Ind 53.62(1)(a). 6. Drawings must be provided for all joints and splices (duplication of identical joints is not necessary. The drawings must clearly indicate the contributory number of nails or square inches of plate area required on each member of each joint. 7. A stress diagram (to scale or as function of "L ") must be shown on plans. An acceptable alternate would be to provide calculations using other methods of determining axial loads. Calculations may be replaced by computer output sheets only if computer programs are provided with adequate explanation to the satisfaction of this department. 50-39 8. Calculations must be provided which analyze the combined effects of axial loads and bending moments on top and bottom chord members. 9. A framing plan must accompany the truss plans when several different trusses, bearing conditions and elevation changes occur. 10. All wood trusses shall be securely fastened to the supports and each truss shall be secured in position in accordance with National Design Specifications, Appendix A, Section A -10. 11. A title block must be provided on all submittals indicating the name of owner, exact address of building and location of buildings. If there are several buildings on a lot, the trusses must be properly identified for location (this is not necessary for identical trusses). 12. All truss plans for buildings over 50,000 cubic feet in volume must be sealed or stamp and signed by an architect or professional engineer registered in Wisconsin. The intent is to have each sheet stamped, signed and dated by the engineer or architect responsible for the trusses. 13. Wood trusses shall be designed and constructed in accordance with the "Design Specifications for Light Metal Plate Connected Wood Trusses" as published by the Truss Plate Institute (TPI -78) with listed exceptions as outlined above and stated in Section Ind 53.62(1). 14. An examination fee per Ind 69.09 is required for each building submittal. Miscellaneous Materials Miscellaneous materials have been approved such as self- energized exit signs, polystyrene concrete forms, an emergency release device for overhead grilles in shopping malls, a modular storage mezzanine, a blast furnace slag aggregate for use in lightweight concrete block and a light gauge metal deck for diaphragm use. Precast Concrete Precast concrete manufacturers have submitted calculations to verify the accuracy of their load tables. The approval number can be used instead of submitting repetitious structural calculations. Typically the approval covers uniform loading only for a simple span condition. If continuous spans are encountered and /or if concentrated loads are subjected to the precast, the approval number is not valid and structural calculations for those conditions would have to be submitted. 50-40