HomeMy WebLinkAboutBuilding 70-C-927 (07/16/1970) 'AJI: S tate .111,4 a of Wisconsin \ DEPARTMENT OF INDUSTRY, LABOR and HUMAN RELATIONS P.O. BOX 2209 July 16, 1970 310 PRICE PLACE MADISON, WISCONSIN 53701 PLEASE REPLY TO INDUSTRIAL SAFETY & BUILDINGS DIVISION Irion, Reinke & Associates, Inc. 805 North Main Street Oshkosh, Wisconsin 54901 Gentlemen: Oshkosh Savings & Loan Assoc. West Side Office 141 North Sawyer Street Oshkosh, Winnebago County Plan File 70-L-927 Volume 58,500 (Two Inspections Paid) Building plans and heating and ventilation plans for the above project have been stamped, "Couditionally Approved--See Correspondence," and two or more copies are being returned under separate cover. You are hereby advised that the designer is responsible for all code requirements not specifically brought to your attention. The code requirements are set forth in Chapters 50 to 59 of the ,:wles of the Department. Ind 50.11 une set of plans bearing the stamp of approval shall be kept at the building site. Ind 51.15 (b) Protect west wall of vestibule 101 if sill is less than 24 inches high. Provide glaas doors with a push bar or plate inside and outside. Ind 50.10 Please submit typical footing and foundation wall calculations. It is noted that the specifications rqquire the fabricator of the wood trusses to submit calculations and obtain approval of this department. The situation also applies to precast concrete floor systems. Calculations and/or Wisconsin state approval number for the trusses and the precast concrete shall be submitted and approval obtained prior to their installation in the building. Ind 53.09 (8) The maximum allowable span for an 8 inch concrete block wall is 25 feet. The designer shall submit calculations showing that the load beariu„ 8 inch concrete block wall in the basement will not be overstressed. Irion, Reinke & Associates, Inc. -2- July 16, 1970 Ind 53.20 (3) Frame superstructure of this building shall be securely anchored to the foundation. Ind 52.58 Dry wall in rooms 108 and 109 shall be 5/8 inch thick. Ind 52.59 (4) Doors 6, 7 and 12 shall be 32 inches wide. Grab bars shall be provided in each toilet room. Ind 54.12 (6) The watercloset in the mans toilet room shall have a self- rising seat. Ind 22.18 Provide a restroom with a cot or couch. The womens lounge is not acceptable for this purpose. Ind 59.41 (7) Outside air and recirculated air shall be filtered. Ind 59.60 (6) The minimum size of the combustion air intake shall be 100 square inches. Sincerely yours, Clyde Bryant Plan Examiner CB : cv cc: ij.strict 4 -5 d L. Reimer, Bldg. Insp. Oshkosh Savings and Loan Association 16 Washington Avenue Oshkosh, Wisconsin 54901 Harrington Associates, Inc. 316 East Silverspring Drive Milwaukee, Wisconsin 53217