Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0144626-Building
Op• CITY OF OSHKOSH No 144626 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD i ON THE WATER C /T/ v ' CIS /6 S (/ [r '' 1_jg -t1 1 Job Address 2069 HICKORY LN Owner _ • • ' - • - - Create Date 12/07/2010 Designer Contractor JF AHERN CONSTRUCTION Category 260 - City of Oshkosh -New Plan Type • Building 0 Sign 0 Canopy 0 Fence O Raze j Zoning Class of Const: Size Unfinished /Basement Sq. Ft. Rooms Height Ft. ❑ Projection Finished /Living Sq. Ft. Bedrooms Stories Canopies Garage Sq. Ft. Baths Signs Foundation • Poured Concrete 0 Floating Slab 0 Pier 0 Other 0 Concrete Block 0 Post 0 Treated Wood Occupancy Permit Occupancy Fee $0.00 Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use /Nature CITY/ 8' x 8' Pump house* Prefabricated building. K to issue JZ. approvals Work 9 pprovals granted from zoing and Engineering. HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $36,650.00 Plan Approval $0.00 Permit Fee Paid $0.00 Park Dedication $0.00 Issued By: Date 01/12/2011 Final /O.P. 00 /00 /0000 ❑ Permit Voided; Parcel Id # In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. I have read and understand the afore mentioned information. Signature Date Agent/Owner Address 855 MORRIS ST FOND DU LAC WI 54901 - 0000 Telephone Number To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. CITY OF OSHKOSH No 144626 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 2065 HICKORY LN Owner MICHAEL H /PATRICIA L SCHUMERTH Create Date 12/07/2010 Designer Contractor JF AHERN CONSTRUCTION Category 260 - City of Oshkosh -New Plan Type • Building 0 Sign - 0 Canopy 0 Fence 0 Raze Zoning Class of Const: Size Unfinished /Basement Sq. Ft. Rooms Height Ft. [] Projection Finished /Living Sq. Ft. Bedrooms Stories Canopies Garage Sq. Ft. Baths Signs Foundation • Poured Concrete 0 Floating Slab 0 Pier 0 Other 0 Concrete Block 0 Post 0 Treated Wood Occupancy Permit Occupancy Fee $0.00 Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use /Nature ITY/ 8' x 8' Pump house* Prefabricated building. OK to issue JZ. approvals granted from zoing and Engineering. of Work L HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $36,650.00 Plan Approval $0.00 Permit Fee Paid $0.00 Park Dedication $0.00 Issued By:F J r ti5 Date 01/12/2011 Final /O.P. 00 /00 /0000 fl Permit Voided Parcel Id # 1526180000 In the performance of this work 1 agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. I have read derstand t afore mentioned information. Signature I Date / 1) Agent/Owner Address 855 MORRIS ST FOND DU LAC WI 54901 - 0000 Telephone Number To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. 4 .1 DARRYN BURICH Planning Services Director OIHKOIH ON THE WATER TO: Steve Brand - Applicant FROM: Todd M. Muehrer - Site Plan Review Coordinator RE: 2065 Hickory Lane — Pumping station upgrades v7 65 Date: 10/28/10 Attached to this memo are comment sheets from the respective City of Oshkosh Departments that participated in the Site Plan Review Committee Meeting on 10/27/10 regarding your submittal to construct pumping station upgrades. As the sheets indicate, zoning approval has been granted for the project. However, more information is required by the Dept. of Public Works. The comments provided by the Oshkosh Police Department are advisory comments only. If you have questions regarding any of the comments provided, directly contact the department reviewer listed on each comment sheet. Thank you. Department Contact Person Findings Summary Planning Services Todd Muehrer, Development Review Comment sheet included /see Division Coordinator /Zoning Administrator attached. Inspection Services Brian Noe, Building Systems Inspector & Division Paul Wolf, Plumbing Inspector No comments included. Public Works /Engineering & Steve Gohde, Assistant Director of Public Comment sheet included /see Storm Water Works & James Rabe, Civil Engineer attached. Transportation Chris Strong, Transportation Director Department No comments included. Fire Department Mike Augsburger, Lieutenant No comments included. Police Department Officer Joe Nichols, CPTED Crime Comment sheet included /see Prevention attached. Health Services Division Mark Ziemer, Interim Health Director No comments included. Parks Department Ray Mauer, Parks Director No comments included. Forestry Division Bill Sturm, City Forester No comments included. City Attorney Lynn Lorenson, City Attorney No comments included. Wisconsin Public Service Scott Hanson, Wisconsin Public Service No comments included. Plan Approval Correspondence Detail 10/21/2010 City o' Oshkosh App Number: 3181 Date Received: 10/21/2010 Owner Name: MICHAEL H /PATRICIA L SCHUMERTH Job Address: 2065 HICKORY LN Owner Address: 2065 HICKORY LN App Type: Zoning Owner City: OSHKOSH WI 54901 -2513 Plan Type: Plan Number: Submit Name: CITY OF OSHKOSH DPW g - - — — Pumping station upgrades per submitted site plan. Address: 215 CHURCH AVENUE City: OSHKOSH WI 54903 - Date Collected: 10/21/2010 Fee Waived Fee: $0.00 Fee Paid — I Fee Paid Date: Plan Status: 0 Cancelled • Approved 0 Not Approved O On Hold Status Date: 10/21/2010 Net Days to Complete Review: Correspondence Item: Date: Type: 1 10/21/2010 Note CUP approved 9/28/10 @ CC. Setback variances recd from BOA on 10/13/10. DEPARTMENT OF PUBLIC WORKS 215 Church Avenue ( P.O. Box 1130 Oshkosh, Wisconsin 54903 -1130 Ph. (920) 236 -5065 Fax (920) 236 -5068 O1H<Of H ON THE WATER October 27, 2010 Steve Brand City of Oshkosh 215 Church Avenue Oshkosh, WI 54901 RE: Public Works Site Plan Review #1 (2069 Hickory Lane) Dear Mr. Brand: The following comments pertain to the Public Works Site Plan that you submitted on October 19, 2010 on behalf of The City of Oshkosh for their property at 2069 Hickory Lane in the City of Oshkosh. 1. The following comments are general comments pertaining to the plans. A. Please show the additional easement on the plans for where the electrical line will be installed on private property. If additional easement is not being obtained, please have note on the plans that designates work area. B. The plans have not been signed and sealed by a Professional Engineer licensed in the State of Wisconsin. Please have the plans signed and sealed. Please respond to each of these items in writing. If any additional changes are incorporated into the plan for your next submittal, please indicate in writing those changes as well. If you have any questions, please do not hesitate to contact us. Sincerely, James Rabe, P.E., CPESC Civil Engineer II cc: David Patek, P.E., Director of Public Works Steve Gohde, P.E., Assistant Director of Public Works Laura Gray, Civil Engineer I Justin Gierach, Civil Engineer I File I:\Engineering \SWMP - Non - Residential \2069 Hickory Ln - Hickory Street Page 1 of 1 Pump Station\Public Works Site Plan Review #1.doc SITE PLAN REVIEW -PRE- CONSTRUCTION CPTED OSHKOSH POLICE DEPARTMENT FOR HICKORY LANE PUMP STATION HICKORY LANE AT E. MURDOCK AVE OCTOBER 21, 2010 REVIEW BY: OFFICER JOE NICHOLS On Thursday, October 21, 2010, Officer Joe Nichols reviewed the plans for the proposed building site of the Hickory Pump Station. After my review of this building proposal, I have identii1ed potential concerns in regards to the following subjects and the recommended suggestions to alleviate concerns: LIGHTING With no schematic of the lighting, the following general recommendations are advised: • Lighting to city ordinance requirements LANDSCAPING Bushes are to be maintained at a height of no higher than two feet and tree canopy no lower than seven feet. View of the entrance /exit points to the building will be unobstructed by any and all trees. GRAFFITI ABATEMENT With the potential of graffiti being a problem at this location, a building material that is easy to paint should be used to cover any graffiti on the building itself. Respectfully Submitted, Joseph Nichols Crime Prevention Officer Oshkosh Police Department (920) 236 -5742 CONSOLIDATED TREATMENT PLANT AND PUMPING STATION IMPROVEMENT PROJECTS FOR THE CITY OF OSHKOSH OSHKOSH, WISCONSIN SEPTEMBER 2070 a 910 West Wingra Drive Madison, WI 53715 608.251.4843 608. 251.8655 FAX www.strand.com CONTRACT NO. 10 -15 L File: S:\MAD\1300--i399\ PROJECT LOCATION MAP NO SCALE Tall Free (800) 242.8511 Milwaukee Area (414) 259.1181 Hearing Impalred TDD (800) 542.2289 ww w. D Ig g e rs H otl I n e. c o m a 0 )ROJECT OCATION E AREA MAP) WASTEWATER TREATMENT PLANT AREA MAP NO SC'LE 00.0i.dwg Time: Aug 16, 2010 -- 2;17pm �s G STRAND ASSOCL MS,{V0. ENlaINEERa SHEET 00-6-01 JOB N0. 1382 -043 DETNL NOTATION — RIGHT OF WAY MARKER - " � - EXISTING EWS NC WATER ATTAIN. S EWE R MANHOLE, AND PIPING DE5IGNATTDNJS PIP INQ MWBOLS - S DETAIL LETTER CONSTRUCTION EASEMENT �-�-- ° ..... ...S.. a' j ~r FORCE MAIN IN PROFILE A AIR ELBOW DO A C� G DRAWING THAT DETAIL IS ON SEWER AND WATER PLAINS (� SHOWN ON PERAR4iEHF EiISEMENf OH NEW WATER MAIN, SEWER. W— MANHOLE AND FORCE MAN CA COMPRESSED AIR O ELBOW UP � � SECTION NOTATION SEWER AND WATER PLANS ^S ' IN PROFILE ,� — — SECTION LINE CW CDLD WATER --®- -- METER y CENTER LINE NE O CULVERT IN PROFILE _ t SECTION NUMBER SOIL BORING NEW GRADE LINE CWR COLD WATER RETURN+ STRANER Y DRAWING THAT SECTION IS SHOWN ON 02 BENCH MARK -- 1 SLOPE INTERCEPT CWS COLD WATER SUPPLY. --8 -- TEE DOWN SECTION NUMBER G PROPERTY STAKE ORIGINAL GROUND IN PROFILE 0 DEW DISINFECTED EFFLUENT WATER 0 _ TEE UP SCALE _ PRIVATE WELL i; ROCK IN PROFILE DRAWING O SECTION S SHOWN EXISTING UTILITY POLE SURVEY OR REFERENCE LINE G NATURAL GAS PIPING —� P �— UNION ELEVATION NOTATION NEW IfITIlTY POLE ELEVATION LEI ER POINT OF INTERSECTION ---- Hw HOT WATER ---- --- GAS PRESSURE REGULATOR +$^ DRAWING THAT ELEVATION IS SHOWN ON ° BURIED TELEPHONE CABLE PEDESTAL o POINT ON REFERENCE LINE P[ --- HHWR ---- HEATING HOT WATER RENRN PRESSURE INDICATOR EQUIPMENT IOENTIFICATION SIGN '� f � BUILDING IN PROFILE °z LIGHT POLE DIRECTION OF TRAFFIC —1 Hws HEATING 140T WATER SUPPLY PRESSURE TRANSMITTER T TYPE OF EQUIPMENT Gorr EQUIPMENT GROUP f A DECIDUOUS TREE 1 LPC LAW PRESSURE CONDENSATE TEWPERATURE ELEMENT NAM NOTATION FOR COMBUSTIBLE FLUIDS - -0 0 9 RCOML IDENTIFICATION CONIFEROUS TREE DECIDUOUS SHRUBS LPS LOW PRESSURE STEW TEMPERATURE INDICATOR ° Y z DOOR IDENTIFICATION 1 CONIFEROUS CONIFEROUS SHRUBS PIPING . NPN NONPOTABLE WATER - TEMPERATURE TRANSMETTELT ° 999 WINDOW IDENTIFICATION I OUS FLANGE JOINT RL REFRIGERAM LIQUID MANUAL AR VENT [ O KEY /SPECIFEC NOTE CALL-OUT STREAM GROOVED JOINT f� 1 ^r PARTITION TYPE REFERENCE .�- SMEAM OR RIVER RS REFRIGERANT SUCTION ^ CONCENTRIC REDUCER a o M ECHANICAL JOINT p� CE NTER DIVE OF KIM- COLUMN 1 FRAME SYSTEM R It WETLAND AREA PUSH - ON JOINT 5PD SUMP PUMP DESCI{ARCE f] E CCENTRIC REDUCER �Ir OF VIEW BEING CONSIDERED MI1 MATCH URE RAILROAD RUBBER EXPANSION JOIN SW SOFT WATER --� FLE)0$LE CONNECTOR - LARGE SCALE G SOLVENT WELD OR THREADED JOINT REVISION BRIDGE ^ - -�_ --- VENT PIPE 6 PIPE CDUPUNO WITH TENSION LIES +EL 1000,00 FINISH ELEVATION � EXISTING CULVERT Y1 .� 40 SPOT ELEVATION a - e SILT FENCE SMALL DIAMETER PIPE --- - - - - -- WASTE BELOW GRADE g w M5TING OBJECTS ARE SCREENED x FENCE WAIL PIPE WASTE /480VE GRADE a E](ESTINC OBJECTS TO BE ABANDONED -Iry c v o v vv- GUARD RAL a � xxxx"NxXxxxa EXISTING OBJECTS CURB, GLTITER AND INLET WALL SLEEVE -- -- -- 5TL1RM BELOW GRADE r TO BE DEMOLISHED O c = = = == HIDDEN OBJECT REJECT CURB FABRICATED WALL SL EEVE - - - -- STORM ABOVE GRADE J Q = 1 FUTURE OBJECT CONTOLIR LINES � ES Q < H z OBJECT SUPPLIED BY OWNER EXISTING DEPRESSION SHUT OFF VALVE VALVE SYMBOLS a 00 V } $ h 0 TOP OF CUT OR BERME ® FLOOR STAND IN PLAN (n 0 EARTH - _.... NR PRESSURE RELIEF VALVE 93 a G S - -Y STOP PLATE - EMBEDDED c a h © SAND. PLASTER, STUCCO - BAANCINO VALVE SIDE GATE - EMBEDDED G F i CONCRETE - Ri W 0 -- NEW WATER MAIN r SLIDE GATE - SURFACE MOUNTED r - 'i+ BALI. VALVE � g 0 ® BRICK ANO VALVE MANHOLE aW—} d ® CONCRETE BLOCK -- WATER MAN AND VALVE IN ROAD BOX c CT =a SLUICE CATS BALL CHECK VALVE W ACOUSTIC BLOCK - Y! EXISTING WATER MAIN — P[�R— PRESSURE/VACUUM RELIEF AND FIRE HYDRANT BUTTERFLY VALVE ASHLAR STONE VENEER a NEW WATER MA A ND LIQUID RING COMPRESSOR tt ® META_ FIRE AUXILIARY HYDRANT ALVE --- O I P OFURCE PLATE CHECK VALVE ~ a METAL LATH JIL S - - -- EXISTINO SANITARY SEWER AND MANHOLE GAS SHUTOFF PLUG VALVE W � ® WOOD- FINISH j--S ��• NEW SANITARY SEWER MANOMETER ® WOOD - FRAMING AND MANHOLE -..- _ _ EXISTING STORM SEWER FD® FLOOR DRAIN -J>T GATE VALVE .a 0 I AND MANHOLE (I- INLET} RDrg ROOF DRAIN 0 PLYWOOD �- GLOBE VALVE 1 ACOUSTICAL TILE SST NEW STORM SEWER HOQ HUB DRAM— I AND MANHOLE (I- INLET) }p HOSE BIBB Lp N LOW PRESSURE CHECK VALVE CYPSUIM BOARD BATi INSULATION F FORCE MAIN — F -� -- VALVE MANHOLE ON FORCE WATER HAMMER ARRESTER r � PRESSURE REDUCING VALVE RIGID INSULATION O WA SUNTIS /DRAINAGE ^ PRESSURE WYE BRANCH V RELIEF VALVE CHECKERED PLATE ----` HANDRAIL R RISER THERMOMETER .-- �.-... 1 - _.. -.- TELESCOPIC VALVE e TRA —S _ MR— MODIFIED RISER TRAP PRIMER 13 NO IN E E R OF THE SITE T TC3 TELEPHONE OR TV CABLE - a YARD HYDRANT 3 -WAY VALVE SH EET CORPORATE UNITS AND MANHOLE TRIPLE DULY VALVE � G GAS MAN - PROPERTY LINE AND DR RIGHT OF WAY 00 -130.03 g UNDERGROUND ELECTRIC GABLE JOB NO. 1382 -043 File: S: \MAD \ 1300 --- - 1399\ 1382\ 043 \Acad \Drawings \00— GO.03.dwg Time: Aug 16, 2010 — 2:17pm ELEMICAL F;A - SWOO FIXTURE �S'IFRSOL (TYPICAL} OH A- INDICATES FIXTURE TYPE Ilk 2- INDICATES CIRCUIT NUMBER SHOWN PANEL DESIGNATION 6- INDICATES SWITCHING /�ryTyNppE)R)WSSE SOLID CIRCLE INDICATES EV ALWAYS ON ® INCANDESCENT, HID, SURFACE DUPLEX, 125 VOLT, ABOVE FURNITURE OR PENDANT DOUBLE DUPLEX, 125 VOLT, ABOVE INCANDESCENT, HID, WALL F--O� 1X4 FLUORESCENT, SURFACE DOUBLE DUPLEX, 125 VOLT OR PENDANT m IX8 FLUORESCENT, SURFACE FOR ELECTRIC WATER COOLER OR PENDANT o—� FLUORESCENT, WALL EXPLOSION-PROOF 1X4 FLUORESCENT, RECESSED P -01 -01 480Y LOAD, REFER TO MCC SCHEDULE 2X2 FLUORESCENT, RECESSED © 2X4 FLUORESCENT, RECESSED O CAN, FLUORESCENT OR HID A EXIT. SURFACE, PENDANT SPEAKER STROBJ~ CEILING MOUNT - ADA RATED OR RECESSED }g MT. WALL ® EMERGENCY LIGHTING $ SWITCHES SINGLE POLE $2 TWO POLE $3 THREE WAY $ FOUR WAY $K KEYED $D DIMMER $ M MANUAL SWITCH (HORSEPOWER RATED) $WP WEATHER PROOF $P SWITCH WITH PILOT LIGHT Q LIGHTING CONTROL STATION ® LOCKOUT STOP SWITCH ® DOOR PDMM SWITCH ® PHOTOCELL EOUIPLIENT, AND VVIRIN G GROUND ROD 10' -5/8' DLA. OH COPPER CLAD Ilk TRANSFORMER SHOWN PANEL DESIGNATION METER (ONE -LINE DIAGRAM) /�ryTyNppE)R)WSSE DISCONNECT. F- FUSED, EV B- CIRCUIT BREAKER ® MOTOR STARTER MAGNETIC DUPLEX, 125 VOLT, ABOVE FURNITURE CIRCUIT BREAKER DOUBLE DUPLEX, 125 VOLT, ABOVE COMBINATION STARTER $T MANUAL STARTER WITH THERMAL DOUBLE DUPLEX, 125 VOLT OVERLOAD PROTECTION m JUNCTION sox FOR ELECTRIC WATER COOLER LINE VOLTAGE THERMOSTAT o—� LINE VOLTAGE THERMOSTAT EXPLOSION-PROOF W /REMOTE BULB P -01 -01 480Y LOAD, REFER TO MCC SCHEDULE VFD ® FOR EQUIPMENT NUMBER VARLASLE FREQUENCY DRIVE E UNDERGROUND C OH OVERHEAD ELECTRIC RCUR NUMBER (TYPICAL) CIRCUIT BREAKER (ONE -LINE DIAGRAM) SHOWN PANEL DESIGNATION METER (ONE -LINE DIAGRAM) /�ryTyNppE)R)WSSE �2(x 6UPLE](, 125 VOLT, WP FIRE ALARM CONTROL PANEL INDICATES WEATHERPROOF FIRE ANNUNCIATOR CONTROL PANEL DUPLEX, 125 VOLT, ABOVE FURNITURE STRODE WALL MOUNT - ADA RATED DOUBLE DUPLEX, 125 VOLT, ABOVE CANDELA RATING 80' AFF FURNITURE ®� DOUBLE DUPLEX, 125 VOLT N3- SINGLE CONVENIENCE, 125 VOLT EWC FOR ELECTRIC WATER COOLER 5K H EXPLOSION- PROOF, ABOVE FURNITURE f EXPLOSION-PROOF ® FIXED EQUIPMENT CONNECTION ED POWER OUnET, VOLTAGE & AMPERAGE AS INDICATED Q---o AUTOMATIC TRANSFER SWITCH • (ONE -LI NE DIAGRAM) ^ O 6 6 CIRCUIT BREAKER (ONE -LINE DIAGRAM) O METER (ONE -LINE DIAGRAM) L I FIRE ALARM PANEL.BOARD AND DETECTION SYMBOLS FRCP FIRE ALARM CONTROL PANEL FAAP FIRE ANNUNCIATOR CONTROL PANEL "PN " r '—STROBE STRODE WALL MOUNT - ADA RATED (SEE MCC SCHEDULE:) CANDELA RATING 80' AFF DENSITY ELEMENT HORN STROBE; WA L MOUNT - ADA RATED M* `-' � - -STROBE CANOEL A RATING 80' AFF O SPEAKER STROBE; W ALL MOUNT -- ADA RATED — STROBE CANDELA RATING So- AFF 5K H HORN: WALL MOUNT - ADA RATED MIS SPEAKER; WALL MOUNT - ADA RATED O *: K F 7' o STROBE; COLING MOUNT - ADA RATED '-STROBE ® N CANDELA RATING HORN STROBE; CEILING MOUNT - AAA RATED � 'STROBE CANDELA RATING S ®I SPEAKER STROBJ~ CEILING MOUNT - ADA RATED t -- - STROBE CANDELA RATING ® AREA OF RESCUE ASSISTANCE ® EMERGENCY TELEPHONE SYSTEM Q HEAT DETECTOR, CELING MOUNT 0 SMOKE DETECTOR; CEILING MOUNT 0. ELEVATOR RECALL SMOKE DETECTOR R NITROUS OXIDE SENSOR ® CARBON MONOXIDE SENSOR �SWTTCH INDICATION f c DIKE SMOKE DETECTOR ir DUCT SIZE ® REMOTE TEST SWITCH o SWITCH INDICATION 0 FIRE ALARM PULL STATION ® SPRINKLER FLOW SWITCH ® SPRINKLER VALVE TAMPER SWITCH FIRE ALARM BELL INSMILIMENTATION O _EOLFIRAENT ANAL YSIS ELEMENT • ANALYSIS INDICATING TRANSMITTER, O *: DO- DISSOLVED OXYGEN, PH -PH, TRB- TURBIDITY, O TSS -TOTAL SUSPENDED SOLIDS, GO-OAS DETECTOR, O CA- CHLORINE ANALYZER, OP- OPYGEN PURITY, O LEI. -LOWER EXPLOSIVE LIMIT, PR- PROXIMITY 0,.2 CONTROL Sw�H DEVICE TYPE TORQUE SWITCH (SEE MCC SCHEDULE:) O DENSITY ELEMENT O DENSITY INDICATING TRANSMf rm O FLAW ELEMENT FLOW INDICATING TRAN O • FIT r: M- MAGNETIC, TM- THERMAL MASS KEY PAD DP- DIFFEREHILA. PRESSURE, U- ULTRASONIC O *: MOTKIN SENSOR P P LE, T- THERMAL. PUSH BUTTON C- CAPACITANCE IE ORO ML MAGNETIC LOCK (CURRENT XFMR, POTENTIAL XFWR) O POWER INDICATING TRANSMITTER O TIME SWITCH O LEVEL ELEMENT` * LEVEL INDICATING TRANSMITTER, LIT, S- SUBMERSIBLE, U- ULTRASONIC �* LEVEL SWITCH, *: C- CONDUCTANCE F -BALL FLOAT TECHNOLOGY A V =VIBRATING F'ORK,B- BUILDING FLOODING ® DIFFERENTIAL PRESSURE INDICATING O TRANSMITTER O PRESSURE ELEMENT O PRESSURE SWITCH O SPEW SWITCH TECHNOLOGY A TEMPERATURE ELEXIENT, TE *: R -RTD, T- THERMOCOUPLE O TEMPERATURE INDICATING TRANSMITTER O TEMPERATURE SWITCH O VIBRATION ELEMENT O VIBRATION INDICATING TRANSMITTER O WEIGHT ELEMENT O TORQUE SWITCH O WEIGHT TRANSMITS R (SCALE) O PRE5ENCE/ABSETNCE DETECTOR TECHNOLOGY A POSITION SWITCH, O *: D -DDDR, L- LIMIT © soLENKoio VALVE P FIXED SECURITY CAMERA i FAN, TILT, ZOOM SECURITY CAMERA TECHNOLOGY A VM130LS DATA JACK Q PHONE JACK © VOICE AND DATA JACKS P WALL MOUNT VOIP PHONE JACK i 54' AM SCADA NETWORK JACK ® DATA RACK O COAX CABLE ® POWER POLE PA H PA SYSTEM HORN SPEAKER; 10' -0' AFF PA SYSTEM SPEAKER S O SPEAKER; CEIUNG MOUNT - ADA RATED O KEY PAD ® GLASS BREAK DETECTOR MS MOTKIN SENSOR O PUSH BUTTON O ELECTRIC STRIKE ML MAGNETIC LOCK O INTERCOM STATION OCCUPANCY SENSOR - 'SEE SCHEDULE FOR SENSOR TYPE Q CARD READER DUCTWORK S SYM90LS SUPPLY OR OUTSIDE AR DUCT (DOWN /OR AWAY) EXHAUST DUCT (UP OR SECTION) EXHAUST OR RETURN DUCT (DOWN /OR AWAY) ROUND DUCTWORK UP M ROUND D DUCTWORK DOWN DAMPER SYMOOLS rul AUTOMATIC DAMPER BDD EWCKDRAFT DAMPER MANUAL VOLUME DAMPER FD 1 -1/2 HR. FIRE DAMPER FIELD MOUNTED CONTROLS OT THERMOSTAT © ROOM H PRESSURE SENSOR Q ROOM SENSOR WSJ DUCT SMOKE DETECTOR © PRESSURE GAUGE ACTUATORS J MOTOR (ELE � y PNEUMATIC 4 SOLENOID EQUIPMUff SMBOIS ACCUMULATOR AR FLOW DIRECTION BASE MOUNTED PUMP z 0 —f BLOWER o CE)UNO DIFFUSER WITH FLEXIBLE DUCT CENTRIFUGAL PUMP p CONNECT TO EXISTING G� a — DT -- DRIP TRAP --a— DUCT BOOST COIL EQUIPMENT TAG FA FLAME ARRESTER FC FDAITE CELL N fA — FLAME TRAP A5SWEILY 0 --�— GRINDER ® INUNE PUMP V) POSITIVE DISPLACEMENT PUMP I Q Q ROOF L'?URAUST FAN H N —�� UNIT HEATER VARIABLE AR VOLUME (V � WITH ELECTRIC o i l y �r Lu c IL W W O a z o a O LL } O y C � v N O VARIABLE NR VOLUME ■ (vAv) Box WITH HEATING z HOT WATER REHEAT COIL v ® FLOATING MIXER SCREW CONVEYOR 9TRAN© A80OCI9TS8, rsIM EN(a INE Ism PI18 00 —GO.04 JOB NO. 1382 -043 File: S; \MAD \1300 ---- 1399 \1382\ 043 \Aead \Drawings \00— G0.04.dwg Time: Aug 16, 2010 — 2;17pm ACTUATORS J MOTOR (ELE � y PNEUMATIC 4 SOLENOID EQUIPMUff SMBOIS ACCUMULATOR AR FLOW DIRECTION BASE MOUNTED PUMP z 0 —f BLOWER o CE)UNO DIFFUSER WITH FLEXIBLE DUCT CENTRIFUGAL PUMP p CONNECT TO EXISTING G� a — DT -- DRIP TRAP --a— DUCT BOOST COIL EQUIPMENT TAG FA FLAME ARRESTER FC FDAITE CELL N fA — FLAME TRAP A5SWEILY 0 --�— GRINDER ® INUNE PUMP V) POSITIVE DISPLACEMENT PUMP I Q Q ROOF L'?URAUST FAN H N —�� UNIT HEATER VARIABLE AR VOLUME (V � WITH ELECTRIC o i l y �r Lu c IL W W O a z o a O LL } O y C � v N O VARIABLE NR VOLUME ■ (vAv) Box WITH HEATING z HOT WATER REHEAT COIL v ® FLOATING MIXER SCREW CONVEYOR 9TRAN© A80OCI9TS8, rsIM EN(a INE Ism PI18 00 —GO.04 JOB NO. 1382 -043 File: S; \MAD \1300 ---- 1399 \1382\ 043 \Aead \Drawings \00— G0.04.dwg Time: Aug 16, 2010 — 2;17pm --a— DUCT BOOST COIL EQUIPMENT TAG FA FLAME ARRESTER FC FDAITE CELL N fA — FLAME TRAP A5SWEILY 0 --�— GRINDER ® INUNE PUMP V) POSITIVE DISPLACEMENT PUMP I Q Q ROOF L'?URAUST FAN H N —�� UNIT HEATER VARIABLE AR VOLUME (V � WITH ELECTRIC o i l y �r Lu c IL W W O a z o a O LL } O y C � v N O VARIABLE NR VOLUME ■ (vAv) Box WITH HEATING z HOT WATER REHEAT COIL v ® FLOATING MIXER SCREW CONVEYOR 9TRAN© A80OCI9TS8, rsIM EN(a INE Ism PI18 00 —GO.04 JOB NO. 1382 -043 File: S; \MAD \1300 ---- 1399 \1382\ 043 \Aead \Drawings \00— G0.04.dwg Time: Aug 16, 2010 — 2;17pm POSITIVE DISPLACEMENT PUMP I Q Q ROOF L'?URAUST FAN H N —�� UNIT HEATER VARIABLE AR VOLUME (V � WITH ELECTRIC o i l y �r Lu c IL W W O a z o a O LL } O y C � v N O VARIABLE NR VOLUME ■ (vAv) Box WITH HEATING z HOT WATER REHEAT COIL v ® FLOATING MIXER SCREW CONVEYOR 9TRAN© A80OCI9TS8, rsIM EN(a INE Ism PI18 00 —GO.04 JOB NO. 1382 -043 File: S; \MAD \1300 ---- 1399 \1382\ 043 \Aead \Drawings \00— G0.04.dwg Time: Aug 16, 2010 — 2;17pm 00 —GO.04 JOB NO. 1382 -043 File: S; \MAD \1300 ---- 1399 \1382\ 043 \Aead \Drawings \00— G0.04.dwg Time: Aug 16, 2010 — 2;17pm File: S: \MAD \1300 -- 9399 \1382 \043 \Arad \Drawings \00— GO.05.dwg 'Fiore: Aug 96, 2010 — 2:97pm Illllp S GENERAL EQUIPMENT ABBREVIATIONS FLLKD ABBREVIATIONS PLUMBING AND PNOCe3SABBREVIATIONS ELECTRICALABEREMATIONS P POLE ,Q PB PULLBOX HVAC EQUIPM ENT ABBRVM%A Q AO AIR COMPRESSOR A AIR AEW APRON END WALL A AMPERE PC PULL CORD ACU ACCUMULATOR ACP AIR COMPRESSOR PIPING OF BLINDFLANGE AFV AUDIO VISUAL PH PH SENSOR ACCU ED AIR COOL CONDENSI AOV AR OPERATED VALVE CGS CHLORINE GAS SOLUTION CA COMPRESSEDJUR AF AMPERE FRAME PNL PANELBOARD AFR ARCHITECTURAL FINE TUB AM ANOXIC MIXER D DRAIN CB CATCH BASIN AFM AIR METER AHU AIR HANDUNG UNIT (,� DG DIGESTER GAS Co CONDENSATE DRAIN FLOW PR PAR As AIR SEPIHRA7oR AST AUTOMATIC STRAIN ER TXV DIVERSION CI CAST IRON AHJ AUTHORITY HAVING JURISDICTION pRI pFUMARY BLR BOILER BSLP BLENDED SLUDGE PUMP DRL DIGESTERREEHEFEINE c0 CLEAN OUT AIC AMPERE INTERRUPTING CAPACITY PS PRESSING BB BASEBOARD B BLOWER DS DIGESTER SUPERNATANT COND CONDENSATE AL ALUMINUM P7 PRESSURE TRANSDUCER C CONVECTOR BLR BOILER DSL DIGESTED CPVC CHLORINATED POLYVINYL CHLORIDE AT AMPERE TRIP PTF POTENTIAL CU CBLING DIFFUSER GIN COLD WATER CHILL CALLER BFV BUTTERFLY VALVE EF EXCESS FLOW ATS AUTOMATIC TRANSFER SWITCH D DRAIN PVC POLYVINYL CHLORNDE CT COOLING TOW ER CENT CENTRIFUGE FE FINAL EFFLUENT bCHP DOUBLE CHECK BACKFlOW PREVENTER AM AMERICAN WIRE GAUGE PM POWER CUH HEATER CABfNET UNIT HE CNTP CENTRATEPUMP F FORCEMAIN OF DRIMNOFOUNNTAIN C CONDUIT RE REQUEST TO EXIT CWP CHILLEDWATERPUMP CENTP CENTRIFUGE FEED PUMP G NATURAL GAS DFU DRAINAOR FIXTURE UNIT CATV CABLE TELEVISION Ix" DRY COOLER RTS REMOTE TEST SWITCH CP CHEMICAL PUMP GTS }l GRAVITY TCKENFR SUPERNATANT DI DUCTILE IRON CB CIRCUIT BREAKER RVSS REDUCED VOLTAGE SOLID STATE DH DEHUMIDIFIER COMP COMPRESSOR OR GRIT ESEW EMEROElNCY SHOWER EYEWASH CCTV CLOSED CIRCUIT TELEVISION SC SHORT CIRCUIT DL DRUM LOWER DEC DEWATERED BIOSOUDS CONVEYOR ML NPw W Id -P BLE L NoN7'OTAwATER EVI EWC E ELECTRIC WATER COOLER CKT CIRCUIT SCADA SUPERVISORY CONTROL AND EBB EDH ELECTRIC BASE BOA R D ELECTRIC DUCT HEATER ER DP DRAINAGEPUMP OF OVERFLOW FCO FLOOR CLEAN OUT CR CARD READER SCC SUPERVISORY CONTROL CENTER EF IXHAUSTFAN DRLP DIGESTER RECIRCULATION PUMP CC ODOR CONTROL FD FLOOR DRAIN CS CONTROL STATION SE SERVICE ENTRANCE EG EXHAUST GRILLE DSLMP DIGESTER MIXING PUMP PEC POLYELECTROLYTE CHEMICAL lie HOSE BIBB CT CURRENT TRANSFORMER SEC SECONDARY FJ EXPANS[ONJOINT DSLTP DIGESTED SLUDGE TRANSFER PUMP POP PERFORATED DRAIN PIPE HO HUB DRAIN CU COPPER SH SHIELDED EL EXPANSION LOOP DOW DOWNWARD OPENING WEIR GATE PRF PROCESS RETURN FLOW HOPE KOH DENSITY POLYETHYLENE HEATING HOT WATER RETURN DC DIRECT CURRENT SPT SUBMERSIBLE PRESSURE TRANSDUCER ER ERO EXHAUSTREGISTER ELECTRIC REHEAR COIL £FC EXCESS FLOW CLARIFIER PRE PRIMARY FFfLUFNT HAWS HAS HEATING HOT WATER SUPPLY DISC DISCONNECT SS STAINLESS STEEL ERU ENERGY RECOVERY UNIT EFP EXCESS FLOW PUMP PPo PHIIMARY INFtuENi HR HOSE REEL DM DENSITY METER SV SOLENOID VALVE Em ELECTRIC UNIT HEATER EFSP EXCESS FLOW SOLIDS PUMP PRS PRIMARYSLUDGE HDYL KOH WATER LEVEL DO DISSOLVED OXYGEN DEVICE SW SWITCH EWH ELECTRIC WALL }SEATER EP EFFLUENT PUMP PS R PLANT SANITARY S EWER RETURN ACTIVATED SLUDGE w HOT WATER OP DOOR POSITION SWITCH TEL TELEPHONE FCU FAN COIL UNIT o a y ID ID Z PC FINAL CLARIFIER RW RAW WASTEWATER It IWP INVERT ELEVATION INDIRECT WASTE PIPE DT bIFF£RENTIALPRESSURETRANSDUCER T THERMOSTAT FD PR FIRE DAMPER FINNED TUBE RADIATION a Y FILT FILTER SAN SANITARYSEWER L LAVATORY E EMERGENCY TS2W TWO SPEED TWO WINDING FUR FURNACE a FM FLOW METER s SCUM MB MOP BASIN EMS EMERGENCY STOP TYP TYPICAL GRV GRAVITY ROOF VENTILATOR GC GRIT CLASSIFIER $A SAMPLE MR MANHOLE EMT ELECTRICAL METALLIC TUBING UFM ULTRANSONIC FLOW METER GUH GAS UNIT RETATER GFM GAS FLOW METER SB SODIUM &SULFITE PHW P PROCESS HOT WATER PUMP EOL END OF LINE DEVICE UG UNDERGROUND He HEATING CG[L fA �a GCS GP GAS COMPRESSOR SKID GRIT PUMP SD SE SCUM DECANT SECONDARY EFFLUENT POC POINT OF CONNECTION ES ELECTRIC STRIKE ULT ULTRANSDNIC LEVEL TRANSMITTER HP HRtP HEAT PUMP BEAT RECOVERY PUMP * d SH SODIUM HYPOCHLORITE PRV PRESSURE REDUCING VALVE FAAP FIRE ALARM ANNUNCIATOR PANEL UPS UNINTERRUPTIBLE POWER SUPPLY HU HUMIDIFIER 0 GRN GRINDER SL SLUDGE PVC POLYVINYL CHLORIDE FACP FIRE ALARM CONTROL PANEL UTP UNSHIELDED TWISTED PAIR HWH HOTWATERUNITHEATER GT GRIT TRAP SPD SUMP PUMP DISCHARGE CC OUICK CONNECT FIT FLOW INDICATING TRANSMITTER V VOLTS HWP HOT WATER PUMP GUH GAS UNIT HEATER ST STORM SEWER RCP REINFORCED CONCRETE PIPE FLA FULL LOAD AMPERES VFO VARIABLE FREQUENCY DRIVE HTX NEAT EXCHANGER W GIN GRIT WASHER SW SERVICE WATER RD ROOF DRAIN FLS FLOW SWITCH W WIRE OR WATT L LOWER fJ HBT HYIDRDPNEUMATIC BOOSTER TANK SWS SEAL WATERSUPPLY RZBP REDUCED ZONE BACKFLOW PREVENTER FM FLOW METER WP WEATHERPROOF MAU MAKEUP AIR UNIT MH HTX HEAT EXCHANGER TO TRENCH DRAIN {ST) s SD so SINK SHOWER DRAIN FIRE PUMP CONTROL PANEL WF SCALE P PWP PUMP PROCESS WATER PUMP O IP INFLUENT PUMP TSL THICKFNEDSLUOGE SEJ SEWAGE NECTOR FS FLOAT SWITCH XPMR TRANSFORMER RF RETURN FAN MA MOTORIZED ACTUATOR 1 WAS "ACKENED WASTE ACTIVA7EDSLUOGE SHR SHOWER FT FEET XP EXPLD510N PROOF G RETURN GRILLE MBV MOFOR�D BALL VALVE V VENT SP SUMP PUMP FVNR FULL. VOLTAGE NON-REVERSING Y WYE RR REGISTER MFS MECHANICAL FINE SCREEN WAS WASTE ACTIVATED SLUDGE SS STAINLESS STEEL FVR FULL VOLTAGE REVERSING ZS ZERO SPEED RTU ROOFTOP UN17 W MIX MIXER W POYABLEWATER SV SOLEdNOIOVALVE GFI GROUNOFAULTINTERRUPTER 30 SUCT10NDIFFUSER MOV MOTOR OPERATED VALVE SYS T SERVICE SINK TANK GFM GAS FLOW METER 5F so SUPPLY FAN SUPPLY GRILLE ;p 0 MP MIXING PUMP TO TRENCH DRAIN GFP GROUND FAULT PROTECTION (EQUIPMENT) SR SUPPLYREGISTER te te MPE MISCELLANEOUS PROCESS EQUIPMENT u URINAL GRID GROUND ST STEAM TRAP g MST MANUAL STRAINER V VENT GRS GALVANIZED RIGID STEEL SUR $TEAM URT HEATER — MT MICROTURBINE Ys VACUUM BREAKER HOA NANOOFFAUTO RCP TEMPERATURE CONTROL PANEL Z NRP NITRATE RECYCLE PUMP VCP VITRIFIED CLAY PIPE HP HORSEPOWER TO TRANSFER GREECE O OCD OVERHEAD COILING DOOR VTR W VENT THRU ROOF WASTEPIPE HV HIGHVOLTAGE GENERAI)WACABBREVIATIONS UH W UNIT HEATER UN7YElTILATOR OCE ODOR CONTROL EQUIPMENT WCO WALLCLEANOUT HZ HERTZ VAV VARIABLE AIR VOLUME BOX 7 ' y N 2 PC PROGRESSINGCAVITYPUMP WC WATER CLOSET IG ISOLATED GROUND ACH AIR CHANGES YD VOLUME DAMPER Q f, PCD PRIMARY CLAWFIER DRIVE WH WATER HEATER AMC INTERMEDIATE METAL CONDUIT ABOVE FINISHED FLOOR VFD VARIABLE FREQUENCY DRIVE - Z Y V — PCFD PRIMARY CLARIFIER FLOCCULATOR DRIVE IN WATER SOFTENER J JUNCTION BOX ALT ALTERNATE XT EXPANSIONTANK Q S H PF POLYMER FEEDER WSfU WATER S ERWCE FIXTURE UNIT KVA K {LOVOLTAMPERES AP BTU ACCESS PANEL BRITISH THERMAL UNIT > g h 7 O PFP POLYMER FEED PUMP KVAR KILOVOLT AMPERES REACTIVE STEM BRITISH THERMAL UNIT PER HOUR IL C 3 PRCP PHOSPHORUS REMOVAL CHEMICAL PUMP KIN KILOWATT CFM CUBIC FEET PER MINUTE G G PRCT PHOSPHORUS REMOVAL CHEMICAL TANK LIT LEVEL INDICATING TRANSMITTER CLO CB LING Q 1[ PREP PROCESS RETURN FLOW PUMP LP LIGHTING PANEL COND CONDENSATE v H PRSP PRIMARY SLUDGE PUMP LTG LIGHTING GAT DB DISCHARGE AIR TEMPERATURE DRY BULB TEMPERATURE Q d O PTP POLYMER TRANSFER PUMP LV LOW VOLTAGE DOC DIRECT DIGITAL CONTROL p, RAE] REFRIGERATED AIR DRYER MAT V MASTER ANTENNA TELEVISION DG DOORGRILLE F RASP RETURN ACTIVATED SLUDGE PUMP MC METAL GLAD DX DIRECT EXPANSION RM RAPID MIXER MCB MAIN CIRCUIT BREAKER EA EXHAUST AIR L LI SAM SAMPLER MCC MOTOR CONTROL CENTER EL EN ASR TEMPERATURE SCMP SCUM PUMP MCCB MOLDED CASE CIRCUIT BREAKER ES P RELVAT1ON EXTERNAL STATIC PRESSURE SCW SCREENINGS WASHER MCM THOUSAND CIRCULAR MILS EMT ENTERING WATER TEMPERATURE SEJ SEWAGE EJECTOR MCP MOTOR CIRCUIT PROTECTOR PC FAIL CLOSED I] SG SLIDE GATE MDP MAIN DISTRIBUTION PANELSOARD FLA FULL LOAD AMPS SHP SODIUM HYPOCHLORITE PUMP MFM MAGNETIC FLOW M ETER FO FAIL OPEN Q SLG SLUICE GATE ML MAGNETIC LOCK FPI FINS PER INCH O SP SUMP PUMP MLO MAIN LUGS ONLY FPM FT FEET PER MINUTE PEEP j O SSC 5CREENINGSSCREWCONVEYOR MO MOTOROPERATEO GA GAUGE N STCP STRUVITE CHEMICAL PUMP MS MOTION SENSOR GPM GALLONS PER MINUTE p STG STOP E MSS MA SWITCHBOARD LAT LEAVING AIR TEMPERATURE V SV S I OLEHOO VALVE NITS TRANSFER MANUAL TRANSFER SWITCH NUAL LWT LEAVING WATER TEMPERATURE UV ULTRAVIOLET DISINFECTION MY MEDIUM VOLTAGE MBH MC THOUSANDS OF BTU PER HOUR MECHANICAL CONTRACTOR NIA NOTAPPLICABLE NA NOTAPPUCABLE NAG NOTIFICATION APPLIAHCE CIRCUIT PANEL NIC NORMALLYCLOSED NC NORMALLYCLOSED NO NORMALLY G EN NEC NATIONAL ELECTRIC CODE NPT NATIONAL PIPE THREAD NM NONMETALLIC Nis NO7TOSCALE QA OINT'SIDEAIR NO NORMALLYOPEN OC ON CENTER STRAN0 NTS NOT TO SCALE OV OUPLETVELOCITY 'O 0 PHASE PD PRESSURE DROP DCB OR. CIRCUIT BREAKER PSI POUNDS PER SQUARE INCH R N 0 1 N B e R B OL O VERLOAD Palo POUNDS PER SQUARE INCH GAUGE OS OCCUPANCYSENSOR RA RETURN AIR PER MINUTE s y.{ OT OVERTEMP S RP A M SF S REU PPP L Y UAIR SUPPLYFAN X SP STATIC PRESSURE 00—G ©.05 SOB NO. 1382 —M File: S: \MAD \1300 -- 9399 \1382 \043 \Arad \Drawings \00— GO.05.dwg 'Fiore: Aug 96, 2010 — 2:97pm Illllp — 2:97pm �s 10' tlll ATT 2G6 E.iC€if�45' 1.�tiE 'c l 1O' tlTSF -fly f � f f '752 . f 2 - 3 3 1 zsss €;c-(Y CaUf4T I 1 f 1 f t y PT2cIx.7w UT:E €tFCTT1c 1 6\ Lf� 16T, :t.' d� C3 EL. 750+ .3+ d C) G g ■■11Y I�■■' ■ ■■ ■ ■ ',i! ■ ■ !11..11....■. BENZ 1111 ■!■ ■ ■ i ■1 1111 ' wr're ■... 1111■■■ f■■■■■ ■■■■ri ■ LOCATION OF ' F KEY S= FIG41= S 11t3cot L O TO r ''rrr,p v s SITE PLAN PROYDE SC�R REPLACE IN KIN LANDSCAPING REMOVED OR DAMAGED LXIRING cONsmicnom CALL- DIGGERS HOTLINE ' e iJ2 NEW VALVE MANIFOLD AND BUILDING. 1- 800- 242 -851 1 L. FR EE FREE Toc O NEW PUMP STATION MANHOLE LID AND ACCESS HATCH. TELEFAX (414) 239 - M47 O ENTER SRE FROM HICKORY LANE TW (FOR HU 4o EMBED) 1-OW- 342 -zu9 �5 EXISnNG PUMP STATION CONTROL PANEL VM STAWTE 18ZO173 (1974} ■■ 1OG &RES 4114. OF J WCW Mr' © NEW PUMP STATION CONTROL PANEL NOT= BEFORE YOU E)(CAYATE us o\ r\ ME ■R■ ■■11Y I�■■' ■ ■■ ■ ■ ',i! ■ ■ !11..11....■. BENZ 1111 ■!■ ■ ■ i ■1 1111 ■ ■... 1111■■■ f■■■■■ ■■■■ri ■ ■ :■11!p 1111■■!■ I I■ Err 1111■■■■ ■ E ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■■ 1111 ■ ■ ■■11!■ 11!11!■ ■ ■ 7 ■ ■1111 iiiai1r ■■■ Es ■ 1111 ■■ wompa■R I►I� �i:GiiaGii��i iii ' 11::lrigN■ ■ rm��� ■■ ■ ■ ■ ■:I 1111■■ 1111 1111 DEMOLITION NOTES: RE14OVE CONCRETE LID, ACCESS HATCH, AND AIR VENT. MMHOLE TO REMAIN. �2 REMOVE ACCESS MANHOLE, VAULT LID, AND WALL TO AT LEAST THREE FEET BELOW GRADE AND MINIMUM TWO FEET CLEAR FROM ANY PORTION OF NEW CONSTRUCTION. Q REMOVE PIPING. VALVES, FITTINGS. AND APPURTEAIFHCES. REMOVE PIPE TO EXTENT NEEDEII FOR NEW PIPING TIE - IN. p REMOVE CONTROL PANEL AND PAD. COORDINATE NEW PANEL LOCATION WITH SCAIlk CONTRACT. 0 z O �r Z y O Z Q �a fn F � N a z n E 1 OO v_ W W 0 s W w W O ff LL x h VI O LL O ( U � O STRAND A8000LA11t%f4M HNGINEER9 08-- CD1.01 JOB NO. 1362 -043 File: S: \MAD \1300 -- 1399\ 1382 \043 \Acad \Drawings \08— CD1,01.dwg Time: Aug 16, 2010 — 2:17pm a PREFABRICATED BUILDING AS SPECIFIED III ■l #��■■ ■ ■[Y�II[ , V� VI'I�Li■�I■tfl 1H 14 TOP AND Q— ---------- ------- - - - - -� �S]T_IlCI► EXISTING W -0' ID PRECAST WET WELL U fN; ET IF 733.$4+ S' Ed-f FROM £ T- 728.8k L 4 n i 0� 70P PLAN 2' 2' GATE VALVE -- 6'x2' THR BLEND FLANOE REDUCER t -i4 TOP & BOTTOM CON J4024' O.C. 2-15 CONT. 1 EXISTING VAULT REMNANT NOT SHOWN FOR CLARTIY IO - TIE TO FLOOR (IYP.) 6'CONCRETE SLAB w/ 4012' IENFORCiNG EACH WAY 6' GRANULAR CUSHION OVER VAPOR BAMET -2' FOUNDATION INSULATION 8' CRUSHED STONE —� THRUST 1(� O4 DRAWINGS OF PUMPING STATION AND EXISTING PIPING ARE BASED ON ORIGINAL PUMP STATION DRAWINGS AND FIELD MEASUREMENTS. ELEVATIONS OF EXISTING PIPE AND NEW PIPE ELEVATIONS BASED ON EXISTING PIPE ELEVATIONS ARE APPRO)IMATE. CONTRACTOR SHALL FIELD VERIFY. O2 STATION PIP1N0, FTrnNGS AND VALVES SHALL BE AWWA Ct51 DUCTILE IRON, SPECIAL THICLOIESS CLASS 53, CONFORMING TO SPECIFICATIONS. O CONIRNCFOR SHALL FURNISH ALL NECESSARY PIPING AND FITTINGS, REGARDLESS IF THEY ARE SHOWN OR NOT, INCLUDING FIELD VERIFIED SPOOL LENGTHS AND FLANGE FILLERS REQUIRED TO COMPLETE THE INSTALLATION, ALLOWING ALIGNMENT OF PUMPS WITH NEW AND EXISTING PIPINO AS SHOWN. 4O THE PUMP ORIENTATION AND THE CEOMETRY OF THE PIPING, FITINCS, AND SUPPORTS SHOWN ON THE DRAWINGS ARE EASED ON THE RECORD DRAY TUGS. 5O FLANGE FILLER. ® PROVIDE MEGALUG OR EQUAL JOINT RESTRAINT. Q 3' PLUG VALVE AS SPECIFIED, O 3' QUICK CONNECT. O SUPPORT PER SPECIFICATIONS, 10 4' CHECK VALVE AS SPECIFIED. 11 4' PLUG VALVE AS SPECIFIED. 1© AIR RELEASE: VALVE AS SPECIFIED. ROUTE DISCHARGE TO WET WELL AND SEAL. PENETRATIONS, 13 PROVIDE NEW W COUPLING. 14 EXTERIOR OF PREFAB BUILDING EXTENDS 1' DOWN NEW FOUNDATION WALL 15 REPLACE EXISTING CONCRETE LLD AND HATCH AS SHOWN. IF CIP OPTION IS USED, PROVIDE STRUCTURAL CALCULA11ONS 70 OWNER FOR APPROVAL DESIGN LOW - 30 PSF. i3 �S a is EL 7§2.00f z 18 PROVIDE NEW 30'x48' DUAL OPENING ACCESS FLITCH. LOCATE HATCH TO ALLOW MAINTENANCE AND REMOVAL OF EXISTING PUMPS AND MOUNTING OF EXISTING GUIDE RATES AND HARDWARE. HME SIDE SHALL BE AS SHOWN. L7 CONTINUOUS DUAL. i' BUTYL RESIN SEALANT STRIPS AT NEW LID TO EXSTING STRUCTURE JOINT. SEAL EXTERIOR JONT WITH SILICONE SEALNT. 18 ATTACH 17ISTIHG RAILS AND APPURTENANCES TO NEW LLD. VERIFY ABILFTY TO REMOVE PUMPS IN NEW MOUNTED LOCATION. 13 4' DUCTILE [RON VENT W/ INSECT SCREEN. ©D 4'x4'x6' THICK CONCRETE PAD. TOC- 751.75 SLOPE AT 29 AWAY FROM BUILDING. N � € m � a � g 8 Z D F a t O L � t? W L N U , o Z Z �a Z I� oa rY. V Z A z r 0 N " o � } o 0 C � V !7 O I m A T pBQ0CIJXT A EE N IID ' 1) ENOINEERG 08 --ASM 1.01 JOB NO. 1382 File: S: \MAO \1300 ---- •1399\ 1382 \043 \Acad \Drawings \O&- ASM1.01.dwg Time: Aug 16, 2010 -- 2:17pm �- ------ --- ------ -- 1 1 1 VAULT ---- _ _ 1—•----....--..... ,........,.s ..............s..l— , I # I I I I I III ■l #��■■ ■ ■[Y�II[ , V� VI'I�Li■�I■tfl 1H 14 TOP AND Q— ---------- ------- - - - - -� �S]T_IlCI► EXISTING W -0' ID PRECAST WET WELL U fN; ET IF 733.$4+ S' Ed-f FROM £ T- 728.8k L 4 n i 0� 70P PLAN 2' 2' GATE VALVE -- 6'x2' THR BLEND FLANOE REDUCER t -i4 TOP & BOTTOM CON J4024' O.C. 2-15 CONT. 1 EXISTING VAULT REMNANT NOT SHOWN FOR CLARTIY IO - TIE TO FLOOR (IYP.) 6'CONCRETE SLAB w/ 4012' IENFORCiNG EACH WAY 6' GRANULAR CUSHION OVER VAPOR BAMET -2' FOUNDATION INSULATION 8' CRUSHED STONE —� THRUST 1(� O4 DRAWINGS OF PUMPING STATION AND EXISTING PIPING ARE BASED ON ORIGINAL PUMP STATION DRAWINGS AND FIELD MEASUREMENTS. ELEVATIONS OF EXISTING PIPE AND NEW PIPE ELEVATIONS BASED ON EXISTING PIPE ELEVATIONS ARE APPRO)IMATE. CONTRACTOR SHALL FIELD VERIFY. O2 STATION PIP1N0, FTrnNGS AND VALVES SHALL BE AWWA Ct51 DUCTILE IRON, SPECIAL THICLOIESS CLASS 53, CONFORMING TO SPECIFICATIONS. O CONIRNCFOR SHALL FURNISH ALL NECESSARY PIPING AND FITTINGS, REGARDLESS IF THEY ARE SHOWN OR NOT, INCLUDING FIELD VERIFIED SPOOL LENGTHS AND FLANGE FILLERS REQUIRED TO COMPLETE THE INSTALLATION, ALLOWING ALIGNMENT OF PUMPS WITH NEW AND EXISTING PIPINO AS SHOWN. 4O THE PUMP ORIENTATION AND THE CEOMETRY OF THE PIPING, FITINCS, AND SUPPORTS SHOWN ON THE DRAWINGS ARE EASED ON THE RECORD DRAY TUGS. 5O FLANGE FILLER. ® PROVIDE MEGALUG OR EQUAL JOINT RESTRAINT. Q 3' PLUG VALVE AS SPECIFIED, O 3' QUICK CONNECT. O SUPPORT PER SPECIFICATIONS, 10 4' CHECK VALVE AS SPECIFIED. 11 4' PLUG VALVE AS SPECIFIED. 1© AIR RELEASE: VALVE AS SPECIFIED. ROUTE DISCHARGE TO WET WELL AND SEAL. PENETRATIONS, 13 PROVIDE NEW W COUPLING. 14 EXTERIOR OF PREFAB BUILDING EXTENDS 1' DOWN NEW FOUNDATION WALL 15 REPLACE EXISTING CONCRETE LLD AND HATCH AS SHOWN. IF CIP OPTION IS USED, PROVIDE STRUCTURAL CALCULA11ONS 70 OWNER FOR APPROVAL DESIGN LOW - 30 PSF. i3 �S a is EL 7§2.00f z 18 PROVIDE NEW 30'x48' DUAL OPENING ACCESS FLITCH. LOCATE HATCH TO ALLOW MAINTENANCE AND REMOVAL OF EXISTING PUMPS AND MOUNTING OF EXISTING GUIDE RATES AND HARDWARE. HME SIDE SHALL BE AS SHOWN. L7 CONTINUOUS DUAL. i' BUTYL RESIN SEALANT STRIPS AT NEW LID TO EXSTING STRUCTURE JOINT. SEAL EXTERIOR JONT WITH SILICONE SEALNT. 18 ATTACH 17ISTIHG RAILS AND APPURTENANCES TO NEW LLD. VERIFY ABILFTY TO REMOVE PUMPS IN NEW MOUNTED LOCATION. 13 4' DUCTILE [RON VENT W/ INSECT SCREEN. ©D 4'x4'x6' THICK CONCRETE PAD. TOC- 751.75 SLOPE AT 29 AWAY FROM BUILDING. N � € m � a � g 8 Z D F a t O L � t? W L N U , o Z Z �a Z I� oa rY. V Z A z r 0 N " o � } o 0 C � V !7 O I m A T pBQ0CIJXT A EE N IID ' 1) ENOINEERG 08 --ASM 1.01 JOB NO. 1382 File: S: \MAO \1300 ---- •1399\ 1382 \043 \Acad \Drawings \O&- ASM1.01.dwg Time: Aug 16, 2010 -- 2:17pm �S PAN N BC ONTRO GENERATOR RECEPTACLE N BREAKER \JUNCTION BOX ENGLO5UREO �� _ y - °ss �� UTILITY METER 0 _ t 9 1 ELECTRIC UHIT 0 - 1 d z o U O O U w UTkrfY PAD MOUNTED TFf�.H�PGnf; +.Eft AM ITENNA� r3;4 CONDUIT PREFABRICATEQ BUILDING RECEPTACLE COO PREFABRICATED BUILDING INTERIOR AND PANEL EXTERIOR LIGHTS PREFABRECATM BULOW0 UNIT HEATER@ ' Lam► 1 No N. err 12E MAL NOTES: I. MAXIMUM DOWN TIME FOR THE ELECTRICAL STRHCE AT THE SITE IS 4 HOURS. 2. SEE SECTION 13102 OF THE SPECIFICATIONS FOR ELECTRICAL EQUIPMENT PROVIDED BY THE PREFABRICATED BUILDING MANUFACTURER. F UNK BREAKER ENCLOSURE METER CONTROL PANEL. WIRE NY © 2"13 13 NEUTRAI 1' CONDUIT 08 GRO I' CONDUIT m 101FWD]FMMIu KEY NOTES: O1 RELOCATE SQSTING CONTROL PANEL AS SHOWN. EXCESS LENUTH OF WIRING ASSOCIATED WITH THE PUMPS, FLOATS, RADAR TRANSDUCER, ETC., IS COILED UP IN THE EXISTING CONTROL PANEL AND JUNCTION BOXES. EXISTING WIRING SNAIL BE EXTENDED IN NEW CONDUIT TO LOCATION OF RELOCATED CONTROL PANEL SPLICING EXISRNG WIRING IS NOT ALLOWED. S FOR ADOMONAL MOUNTING REQUIREMENTS. O ALL ELECTRC& WORK AND EQUIPMENT INSIDE THE BUILDING SHALL BE RATED FOR NEMA 0, CORROSIVE ENVIRONMENTS. O LIGHT FIXTURE SHALL BE MANUFACTURED BY METALUX, MODEL VT3- 232DR- UNV- ER8I- TEH -SSL, OR EQUAL LIGHT FIxTURE SHALL BE PROVIDED WITH PRISMATIC LENS, TWO ENO WATERTIGHT HUBS, AND STAINLESS STEEL LATCHES AND BE RATED FOR WET LOCATIONS. O LICIT FIXTURE SHALL BE MANUFACTURED BY LUMWK, MODEL MH- IP- T- 70- 12OV -L4 OR EQUAL IIGFIT FIXTURE SHAD. BE MOUNTED 8'-0' AFG. ® PROVIDE 3KW, 24OV, 10 ELECTRIC UNIT HEATER MANUFACTURED BY QWAK, CATALOG NUMBER JUW -300, OR EQUAL, UNIT HEATER SFW1 BE PROVIDED WITH A DISCONNECT SWITCH THAT IS SUETABLE FOR CORROSIVE ENNRONNENTS. A REMOTE MOUNTED LINE VOLTAGE T14MMOSTAT MANUFACTURED BY HONEYWELL, MODEL T6051A, OR EQUAL SHALL. BE PROVIDED FOR CONTROL OF THE UNIT HEATER, 1J8 RELOCATE EXISTING UTICA( METER AS SHOWN. UTTLETY METER SHALL BE MOUNTED TO PREFABRICATED BUILDING. COORDINATE SPLICING OF EXISTING SERVICE CONDUCTORS WITH UTILITY COMPANY. O 7 RELOCATE EXISTING MAIN BREAKER ENCLOSURE AS SHOWN. MAIN BREAKER ENCLOSURE SHALL BE MOUNTED TO PREFABRICATED BUILDING WITH STAINLESS STEEL HtiRDWARE. ® PROYIOE NEW 24UV, 2 -POLE, SINGLE PHASE CIRCUIT BREAKER IN EXISTING CONTROL PANEL FOR POWER TO UNIT HEATER IN PREFABRICATED BUILDING. ® RELOCATE EXISTING SCADA ANTENNA LOCATED ON EXISTING CONTROL PANEL MOUNTING STRUCTURE TO THE PREFABRICATED BUILDING ROOF. COORDINATE ANTENNA MOUNTING REQUIREMENTS WITH PREFABRICATED SUIUNNO MANUFACTURER. 4 z 49 01- H Q 0 Z Q CL A. IL t, 4Z W y �a 0 0 0 = W W rt a r z w w Q a N Z 0 U N H 0 }+ 4 = O y �] 0 0 SaL AA AM30CXTF.%F4EDT. 19NIsINEERB 08 —E1.01 JOB NO. 1382 -04.1' Fife: S: \MAD \1300 --- -1399\ 1382\ 043 \Acad \Drawings \08-- E1.01.dwg Time: Aug 16, 2010 — 2:18pm