HomeMy WebLinkAbout16990-Electric (01/11/2011) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH ( DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 1/11/2011 Compliance Date 2/10/2011 Compliance No Address 512 514 GRAND ST Name Address City State Zip Code Sent to G Owner NORMAN A/DONNA BOCK 2242 WHITE SWAN DR OSHKOSH WI 54901 -25 El Required for Occupancy Occupancy Introduction Following a tenant complaint an inspection was performed at the above - mentioned address. The below- listed violation(s) need to be corrected. Item # 1 Code NEC 400.8(1 - 4) Compliance No Compliance Date 02/10/2011 Description Flexible cords - -Uses Not Permitted: (1) As a substitute for the fixed wiring of a structure (2) Where run through holes in walls, 01/11/2011 's tructural ceilings, suspended ceilings, dropped ceilings, or floors (3) Where run through doorways, windows, or similar openings (4) Where attached to building surfaces - a Tamp cord runs down through the kitchen cupboard to the heat tape in the Last crawlspace. 2 ext. cords run from the outlet at the back of the house to other locations as well. Permanent wiring (installed by a Updated licensed electrician) is required to power the heat tape. Item # 2 Code NEC 362.30 A & B Compliance No Compliance Date 02/10/2011 Description TENT shall be securely fastened at intervals not exceeding 3 ft - ENT run through the crawlspace is not supported properly. 01/11/2011 Last Updated , Item # 3 Code NEC 110.26 Compliance No Compliance Date 02/10/2011 Description Working clearance required for electrical equipment. Working space required by this section shall not be used for storage. 01/11/2011 i Dedicated Electrical Space. A space 30" wide and 36 "deep and extending from the floor to a height of 1.8 m (6 ft) above the equipment or to the structural ceiling, whichever is lower, shall be dedicated to the electrical installation. No piping, ducts, leak Last protection apparatus, or other equipment foreign to the electrical installation shall be located in this zone. - Water heater Updated tnfinges on required clearances. Item # 4 Code NEC 406.8(B)(1) Compliance No Compliance Date 02/10/2011 Description 115 and 20- Ampere Receptacles in a Wet Location 15- and 20- ampere, 125- and 250 -volt receptacles installed in a wet 01/11/2011 h ocation shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted. - No cover present on outdoor receptacle near back door. Last Updated Item # 5 Code MUN 16-35A(2) Compliance No Compliance Date 02/10/2011 Description [Every inside and outside stair, eve constructed P ry ry porch, every guardrail and every appurtenance thereto shall be so as to be 01/11/2011 safe to use and capable of supporting the Toad that normal use would cause to be placed thereon, and shall be kept in sound condition & good repair. Such stairs and porches shall be kept free of refuse or stored material. - Floorboards on the front Last porch flex and move a lot, the back guardrail is broken and nowhere near compliant Updated 16990 Page 1 of 3 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 1/11/2011 Compliance Date 2/10/2011 Compliance No Address 512 514 GRAND ST Name Address City State Zip Code Sent to ✓ Owner NORMAN A/DONNA BOCK 2242 WHITE SWAN DR OSHKOSH WI 54901 - 25 Required for Occupancy Occupancy Introduction Following a tenant complaint an inspection was performed at the above - mentioned address. The below - listed violation(s) need to be corrected. Item # 6 Code MUN 16- 33A(9)a Compliance No Compliance Date 02/10/2011 Description All living unit entryways shall be equipped with solid core doors in good condition and deadbolt locks installed as defined in 01/11/2011 Section 16 -22 OMC. Living unit entryways from common areas will require replacement with fire rated door assemblies. The front door has a plexiglass window, neither door has a deadbolt. Last Updated Item # 7 Code MUN 16- 34A(2)c Compliance No Compliance Date 02/10/2011 Description All habitable room windows /door windows shall be effectively screened with screens in good serviceable condition. 2 windows 01/11/2011 on the south side are lacking screens. Last Updated Item # • 8 Code MUN 16- 35A(1)c Compliance No Compliance Date 02/10/2011 Description Multiple windows need repair /maintenance. One window is broken. Several featured in a 2007 correction notice with props 01/11/2011 !holding them open appear unchanged. Last Updated 16990 Page 2 of 3 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 OSHKOSH WI 54903 -1130 ON THE WATER Issue Date 1/11/2011 Compliance Date 2/10/2011 Compliance No Address 512 514 GRAND ST Name Address City State Zip Code Sent to 0 Owner NORMAN A/DONNA BOCK 2242 WHITE SWAN DR OSHKOSH WI 54901 -2567 [_J Required for Occupancy Occupancy Introduction Following a tenant complaint an inspection was performed at the above - mentioned address. The below - listed violation(s) need to be corrected. Item # 9 Code MUN 17 -36B Compliance No Compliance Date 02/10/2011 Description No owner, agent or occupant shall allow on any residential premises any junk, debris or other condition, which creates a public 01/11/2011 nuisance, eyesore and /or hazard. This includes the proper storage & removal of garbage & debris. Garbage shall be properly stored behind and adjacent to the rear of the dwelling farthest away from any public street or sidewalk. Last Updated Summary Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns or questions at 236 -5274. Violations must be corrected and approved within 30 days unless otherwise noted. CaII for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and 'date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 2/10/2011 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call the Ins ection quest line at 236 -5128 noting the address, permit number (when applicable), and the nature of e what� be in ect Signature Date / Inspected by: Adam Krause 236 -5274 akrause @ci.oshkosh.wi.us 1 hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: L✓' Bldg - �` Elec [ HVAC - [ Plbg - 1 Designer - _ r_71 Other MICHELLE PETERS 512 GRAND ST OSHKOSH WI 54901 [✓J Inspector Andrew Prickett 16990 Page 3 of 3