HomeMy WebLinkAbout16990-Electric (01/11/2011) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
( DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER OSHKOSH WI 54903 -1130
Issue Date 1/11/2011 Compliance Date 2/10/2011 Compliance No
Address 512 514 GRAND ST
Name Address City State Zip Code
Sent to G Owner NORMAN A/DONNA BOCK 2242 WHITE SWAN DR OSHKOSH WI 54901 -25
El Required for Occupancy Occupancy
Introduction Following a tenant complaint an inspection was performed at the above - mentioned address. The below- listed violation(s) need
to be corrected.
Item # 1 Code NEC 400.8(1 - 4) Compliance No Compliance Date 02/10/2011
Description Flexible cords - -Uses Not Permitted: (1) As a substitute for the fixed wiring of a structure (2) Where run through holes in walls,
01/11/2011 's tructural ceilings, suspended ceilings, dropped ceilings, or floors (3) Where run through doorways, windows, or similar
openings (4) Where attached to building surfaces - a Tamp cord runs down through the kitchen cupboard to the heat tape in the
Last crawlspace. 2 ext. cords run from the outlet at the back of the house to other locations as well. Permanent wiring (installed by a
Updated licensed electrician) is required to power the heat tape.
Item # 2 Code NEC 362.30 A & B Compliance No Compliance Date 02/10/2011
Description TENT shall be securely fastened at intervals not exceeding 3 ft - ENT run through the crawlspace is not supported properly.
01/11/2011
Last
Updated ,
Item # 3 Code NEC 110.26 Compliance No Compliance Date 02/10/2011
Description Working clearance required for electrical equipment. Working space required by this section shall not be used for storage.
01/11/2011 i Dedicated Electrical Space. A space 30" wide and 36 "deep and extending from the floor to a height of 1.8 m (6 ft) above the
equipment or to the structural ceiling, whichever is lower, shall be dedicated to the electrical installation. No piping, ducts, leak
Last protection apparatus, or other equipment foreign to the electrical installation shall be located in this zone. - Water heater
Updated tnfinges on required clearances.
Item # 4 Code NEC 406.8(B)(1) Compliance No Compliance Date 02/10/2011
Description 115 and 20- Ampere Receptacles in a Wet Location 15- and 20- ampere, 125- and 250 -volt receptacles installed in a wet
01/11/2011 h ocation shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted. - No cover present on
outdoor receptacle near back door.
Last
Updated
Item # 5 Code MUN 16-35A(2) Compliance No Compliance Date 02/10/2011
Description [Every inside and outside stair, eve constructed
P ry ry porch, every guardrail and every appurtenance thereto shall be so as to be
01/11/2011
safe to use and capable of supporting the Toad that normal use would cause to be placed thereon, and shall be kept in sound
condition & good repair. Such stairs and porches shall be kept free of refuse or stored material. - Floorboards on the front
Last porch flex and move a lot, the back guardrail is broken and nowhere near compliant
Updated
16990 Page 1 of 3
INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER
OSHKOSH WI 54903 -1130
Issue Date 1/11/2011 Compliance Date 2/10/2011 Compliance No
Address 512 514 GRAND ST
Name Address City State Zip Code
Sent to ✓ Owner NORMAN A/DONNA BOCK 2242 WHITE SWAN DR OSHKOSH WI 54901 - 25
Required for Occupancy Occupancy
Introduction Following a tenant complaint an inspection was performed at the above - mentioned address. The below - listed violation(s) need
to be corrected.
Item # 6 Code MUN 16- 33A(9)a Compliance No Compliance Date 02/10/2011
Description All living unit entryways shall be equipped with solid core doors in good condition and deadbolt locks installed as defined in
01/11/2011 Section 16 -22 OMC. Living unit entryways from common areas will require replacement with fire rated door assemblies. The
front door has a plexiglass window, neither door has a deadbolt.
Last
Updated
Item # 7 Code MUN 16- 34A(2)c Compliance No Compliance Date 02/10/2011
Description All habitable room windows /door windows shall be effectively screened with screens in good serviceable condition. 2 windows
01/11/2011 on the south side are lacking screens.
Last
Updated
Item # • 8 Code MUN 16- 35A(1)c Compliance No Compliance Date 02/10/2011
Description Multiple windows need repair /maintenance. One window is broken. Several featured in a 2007 correction notice with props
01/11/2011 !holding them open appear unchanged.
Last
Updated
16990 Page 2 of 3
INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
OSHKOSH WI 54903 -1130
ON THE WATER
Issue Date 1/11/2011 Compliance Date 2/10/2011 Compliance No
Address 512 514 GRAND ST
Name Address City State Zip Code
Sent to 0 Owner NORMAN A/DONNA BOCK 2242 WHITE SWAN DR OSHKOSH WI 54901 -2567
[_J Required for Occupancy Occupancy
Introduction Following a tenant complaint an inspection was performed at the above - mentioned address. The below - listed violation(s) need
to be corrected.
Item # 9 Code MUN 17 -36B Compliance No Compliance Date 02/10/2011
Description No owner, agent or occupant shall allow on any residential premises any junk, debris or other condition, which creates a public
01/11/2011 nuisance, eyesore and /or hazard. This includes the proper storage & removal of garbage & debris. Garbage shall be properly
stored behind and adjacent to the rear of the dwelling farthest away from any public street or sidewalk.
Last
Updated
Summary Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns or questions at
236 -5274.
Violations must be corrected and approved within 30 days unless otherwise noted. CaII for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and 'date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 2/10/2011
Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule
inspections please call the Ins ection quest line at 236 -5128 noting the address, permit number (when applicable), and the
nature of e
what� be in ect
Signature Date /
Inspected by: Adam Krause 236 -5274 akrause @ci.oshkosh.wi.us
1 hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: L✓' Bldg -
�` Elec
[ HVAC -
[ Plbg -
1 Designer - _
r_71 Other MICHELLE PETERS 512 GRAND ST OSHKOSH WI 54901
[✓J Inspector Andrew Prickett
16990 Page 3 of 3