GENTLEMEN: A recent inspection of the Family Room and Garage
addition located at 2030 Sheridan St., Oshkosh.
discloses violations of the following sections of the General
Ordinances of the City of Oshkosh.
SECTION LOCATION & NEEDED CORRECTIONS
7 -46 (6) Joist twelve (12) feet or more in length framing
/_,up into the side of headers or trimmers shall have
. supported in metal o
PP joist hangers.
7 -54 (c) Plywood sheathing shall be nailed 6" o.c. on the
edges and 12" o.c. in the field of the sheet, as
required by the Manufacturer's Specifications.
7 -51 (d) Window Openings Shoulder studs on small window
n family room.
Inner stud on jamb: Extend in one (1) piece from
header to bearing and securely nail to outer stud.
- � 0.-#._ I s for ins section of unexcavated s .: c - : .*
interior areas.
An o.eninl of not less than two 2 b' tw. eet
The above violations shall be corrected on or before .
At the time of inspection, these violations were pointed out to
.
Date of Inspection
Inspector
Page -2.
OFFICIAL NOTICE
FROM
INSPECTOR'S OFFICE
CITY OF OSHKOSH, WISCONSIN
NEE_ Mr. Michael Lang
ADDRESS 2030 Sheridan St., Oshkosh, Wis. DATE F 1. 1974
54901
GENTLEMEN: A recent inspection of the Family Room and Garage
addition looated at 20 Sh eridan St. Oshkosh.
discloses violations of the following sections of the General
Ordinances of the City of Oshkosh.
SECTION LOCATION & NEEDED CORRECTIONS
square shall be installed to provide access for
inspection and repair in each unexcavated space
under wood floor construction.
7 -37 (k) Wall vents for unexcavated space:
Foundation wall vents proportioned on a basis of
two (2) square feet for each twenty -five (25)
lineal feet of exterior wall shall be installed for
ventilating all unexcavated spaces and each space
shall have at least two (2) vents, noncorrodible
screening of not over one- quarter (;) inch mesh
shall be installed in each opening.
\■l.JV\ t„SV MN,
CALM 1,7{ ‘QAtoc OcA".u..A. etreplk".40
The above violations shall be corrected on or before 2 - 8 -74
At the time of inspection, these violations were pointed out to
Mrs. Lang
Date of Inspection 2-1 -74