HomeMy WebLinkAbout16976-Final Reinspection (plumbing) 12/27/2010 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER OSHKOSH WI 54903 -1130
Issue Date 12/27/2010 Compliance Date 1/26/2011 Compliance No
Address 1020 -1142 S KOELLER ST
Name Address City State Zip Code
Sent to J Owner KOELLER ONE LLC 1818 W BELTLINE HWY MADISON WI 53713 -2334
Required for Occupancy Occupancy Commercial
Introduction A re inspection of the final plumbing at 1118 S Koeller St (Hobby Lobby) was conducted on 12/22/2010. Inspection revealed
the following violation(s) still exist:
Item # 1 Code Comm. 82.10(1)(f) Compliance No Compliance Date 01/07/2011 IMMEDIATELY
Description A plumbing system shall be of durable material, free from defective workmanship, and designed and constructed so as to
12/27/2010 provide satisfactory service for its reasonable expected life. Wall hung water closets are not properly secured to the structure
of the building. The closets have excessive movement when force is applied. Closets and or carrier fittings are required to be
Last properly sercured to prevent failure and causing injury to users.
Updated
Summary The licensed plumber responsible for the installation shall be required to comply and call for reinspection no later than 1/7/2011. Final
occupancy will not be granted until violations are corrected. Failure to comply may also result in penalty per local ordinance.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 1/26/2011
Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule
inspections please call the spection Request line at 236 -5128 noting the address, permit number (when applicable), and the
nature of what ne s to inspected.
Signature Date /' - • 2.7 mid
Inspected by: Paul Wolf 236 -5052 pwolf @cLoshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: Li Bldg -
u Elec -
Li HVAC -
U Plbg GRP MECHANICAL INC 730 HAWTHORNE DR OMRO WI 54963 -0
L Designer -
12 Other HOBBY LOBBY 1118 S KOELLER ST OSHKOSH WI 54902 -
u Inspector Nicole Krahn
16976 Page 1 of 1