Loading...
HomeMy WebLinkAbout0082485-Building (CD CITY OF OSHKOSH No 0082485 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 2013 SHERIDAN ST Owner DEL TRITT CONSTRUCTION LLC Create Date 10/04/2000 Designer Contractor DEL TRITT CONSTRUCTION Category 110 - New Single Family Plan C8- 110 -1000R Type 0 Building () Sign 0 Canopy () Fence 0 Raze Zoning R -1 Class of Const: 8 Size IRREGULAR Unfinished /Basement 928 Sq. Ft. Rooms 5 Height 17 Ft. Projection Finished /Living 928 Sq. Ft. Bedrooms 2 Stories 1 Canopies Garage 484 Sq. Ft. Baths 1 Signs Foundation Poured Concrete 0 Floating Slab O Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ Constructing new 928 sf 1 -story residence with attached garage, 8' x 12' patio, and paved driveway.. of Work HVAC Contractor G &B PRODUCTS Plumbing Contractor RASMUSSEN PLUMBING Electric Contractor D&A ELECTRIC Fees: Valuation $48,500.00 Plan Approval $75.00 Permit Fee Paid $252.00 Park Dedication $0.00 Issued By: S m S Date 10/25/2000 Final /O.P. Permit Voided In the pertorman - of t is war/ v e e to • - • • •• - II work pur- ant to rules governing the described construction. Signature 411 r _...dL.,,mtv Date Agent/Owner Address 421 W BENT AVE OSHKOSH WI 54901 - 0000 Telephone Number 231 -2156 Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0082485 P.O. Box 7969 APPLICATION Parcel No. Madison, WI 53707 Wisconsin Statues 101.63, 101.73 V. ' ' Constr 7 HVAC 7 Elec Plbg ./1 Erosion 1 1 Other: Owner's Name Mailing Address Telephone No. DEL TRITT CONSTRUCTION LLC 421 W BENT AVE Oshkosh WI 54901 - 0000 (920)231.2156 Contractor: ✓ Con Elec HVAC Plbg Lic/Cert # Mailing Address Telephone No. DEL TRITT CONSTRUCTION 665731 421 W BENT AVE OSHKOSH WI 54901 - 0000 231 -2156 Contractor: Con ❑✓ Elec ❑ HVAC Plbg Lic/Cert # Mailing Address Telephone No. D&A ELECTRIC 260797 P 0 BOX 258 DALE WI 54931 - 0258 (920) 779 -0448 Contractor: r Con I I Elec V1 HVAC I Plbg Lic/Cert # MaTng Address Telephone No. G &B PRODUCTS 1026 S MAIN ST OSHKOSH WI 54902 - 0000 (920) 231 -5699 Contractor: I Con I Elec I HVAC I /1 Plbg Lic/Cert # Mailing Address Telephone No. RASMUSSEN PLUMBING 1914 GREENBRIAR TRL OSHKOSH WI 54904 - 0000 920 - 233 -6747 of Area � Sq. ft. 1/4, 1 /4,Section ,T N,R E(or)W :uilding Address Subdivision Name Lot No. Block No. 2013 SHERIDAN ST Zoning District(s) Zoning Permit No. Front Rear Left Right _ Setbacks ft. ft. ft ft G ki!i ?i�0�!i�!i!i!� .....:., ,...� _�.� ��!i. . > ❑ iii. s! I7 New Repair Vi Single Family Entrance Panel J Forced Air Furnace Fuel Nat. Oil Elea Solid Sola ❑ Alteration 1 Raze ❑ Two Family Size: 100 am. ❑ Radiant Baseboard or Panel Ga x ❑ Addition Move I Garage Service: ❑ Heat Pump Space Htg ✓� ❑ L Other (print) Overhead L Boiler Water Htg ✓ I ❑ Other 2 Underground C entral Air Conditioning ❑ ❑ " ❑ Dwellin unit will have 3 kilowatt or IN r Other .��������� Site Constructed J j �� - — — — - — -• more installed electric space heating equip. onstructed Concrete Infiltration control option is: %/1 Full sealing Unfinished E Manufactured 7 Masonary Sewer .._ T reated Wood of joints. Blower door test. Exterior Basement 928 Sq. ft. °,a ���� — 1 0 Municipal air infiltration barrier. Living Area 928 Sq. ft. ✓ 1-Story • Other ❑ Septic ► - ......: 9 q. �� ����� Vi ..�� �������� ❑ 2 -Story 1 a, :- - - - - - 1 Permit No Envelope 18755 BTU /HR Garage 484 sq. ft. . easonal 7 Other ► ; v�wwvv I n fi ltration 6389 BTU /HR ✓ Permanent . ,5 ��������������.� L Other Municipal Ut ' ----- r j--- j - - 1 ✓ Plus Basement ❑ Private On -Site Well $59,700.00 The applicant agrees to comply with all ap• ca .le code statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, expr. s or pile. f. he •: • - • •- . municip lity; and certifies that all the above information is accurate. APPLICANTS SIGNATUR iI f V `rt�'r DATE SIGNED APPROVAL CONDITIONS h•e mit is issued pursuant to the following conditions. Failure to comply may result in suspension or revocation of this permit or other penalty SEE STANDARD CONDITIONS OF APPROVAL • ���►� - Town ❑ Village ✓ City ❑ County State of: Municipality Number of Dwelling Location: •� City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 onstruction Inspection HVAC Name Shaun Scullion Wis. Permit Seal $30.00 Electrical Other Plumbing Date 10/04/2000 ✓ Erosion Total $105.00 237958 Cert. No. 697254 5BD -5823 (R. 07/92) OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6437 Name DEL TRITT CONSTRUCTION LLC Address 2013 SHERIDAN ST Create Date 10/04/2000 Lot Block Ward Subdivision Zone Street Number Lot Dimensions 50' x 125' ✓ Sidewalk Existing Building Grade Elevation Stakes Set At Site 10/06/2000 Set By D.W.G. Department of Public Works I, the undersigned, owner or agent of the above described property agree to have t • ade established before excavation has commenced. / ... _ . % astr / �',. CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address 126/3 S Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. 2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire- resistive rating of 20 minutes. All drywall joints are required to be taped /sealed unless the joints are fitted so that the gap is no more than a dimes thickness ( 1/20 -inch) and backed by solid wood or drywall with the joints staggered. 3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. 5. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 6. All overframing must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re- inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re- inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd flo► Si�nafure o/ ppCicant: ; / 1 / oU ir afe: /S. ` Y 6) Z;, 4l,(e - -r ci( i/,,,e) 6 w 2 ' 1 F1, i g0�4 1-4."-- & ppe..-rY "Ow 50.0' 50. so.o ,0 N N . . CJI p �.. .r. } x 50.0 il 7 ,,,,,„„..„,,,„.,,f,„,„:,,n 20 1 3 30 2009 1 50.0' o zy uC ° y m 1 �- l 1 - O M . N m y 1S C e fir � i'. C p'+ o 4o 9 0 p m�'a� 0 °• � iu flifffil II) n 0 mS c) C tri 1.., C7 °`° 2m o2.Rg�°wm O N ..E.,emdmev CD r (D �Da ? qmA$ =•