HomeMy WebLinkAbout2010-Electric INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER OSHKOSH WI 54903 -1130
Issue Date 12/14/2010 Compliance Date 1/13/2011 Compliance No
Address 432 WYLDEWOOD DR
Name Address City State Zip Code
Sent to u Owner STEVEN UJERRALYN R KLAPA 432 WYLDEWOOD DR OSHKOSH WI 54904 -0000
J Required for Occupancy Occupancy Two Family
Introduction The following violation was noted at the final inspection of the basement remodeling project.
Item # 1 Code NEC 210.12(B) Compliance No Compliance Date 01/13/2011
Description AFC! Protection is Required. All 120 - volt, single phase, 15- and 20- ampere branch circuits supplying outlets installed in
12/14/2010 dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets,
hallways, or similar rooms or areas shall be protected by a listed arc -fault circuit interrupter, combination -type, installed to
Last provide protection of the branch circuit.
Updated
Summary It is the responsibility of every property owner to confirm compliance with these orders before the compliance date as specified. If you have
any questions regarding these orders please feel free to contact me at 920 - 236 -5036.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 1/13/2011
Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the
nature of r7 eeds o be in? ecte . Signature Q ill �1�(�
Date
Inspected by: Nicole Krahn 236 -5036 nkrahn@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: Lf Bldg
Lf Elec
LJ HVAC
L� Plbg
LI Designer
-
Lj Other
Lj Inspector
16970 Page 1 of 1