HomeMy WebLinkAbout0086110-Building 0 .- CITY OF OSHKOSH No 0086110
OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 1842 MICHIGAN ST Owner DEL TRITT Create Date 05/10/2001
Designer RUS HINTZE Contractor DEL TRITT CONSTRUCTION
Category 110 - New Single Family Plan C9-046-0501R
Type • Building Q Sign Q Canopy Q Fence Q Raze
Zoning R -1 Class of Const: 8 Size 40' X 48'
Unfinished /Basement 1050 Sq. Ft. Rooms 5 Height 18 Ft. ❑ Projection
Finished /Living 1050 Sq. Ft. Bedrooms 2 Stories 1 Canopies
Garage 484 Sq. Ft. Baths 1 Signs
Foundation 0 Poured Concrete 0 Floating Slab 0 Pier 0 Other
0 Concrete Block Q Post 0 Treated Wood
Occupancy Permit Required Flood Plain No Height Permit Not Required
Park Dedication Not Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ New single family with attached garage, driveway - NO DECK OR PATIO
of Work
NEW UDC CODE APPLIES
HVAC Contractor UNKNOWN ? ?? Plumbing Contractor RASMUSSEN PLUMBING
Electric Contractor D&A ELECTRIC
Fees: Valuation $69,000.00 Plan Approval $75.00 Permit Fee Paid $287.00 Park Dedication $0.00
Issued By: r---- Date 05/17/2001 Final /O.P.
❑ Permit Voided
In the perf'-rmance , f this,,a agree to perform all work pursuant to rules governing the described construction.
Signature A • f
Date
Agent/Owner
Address 6228 COUNTY RD N PICKETT WI 54964 - 9533 Telephone Number 589 -4209
Wisconsin „ Department of Industry, WISCONSIN UNIFORM Application No.
Labor and Human Relations
Safety and Buildings Division BUILDING PERMIT 0086110
P.O. Box 2509 Parcel No.
Madison, WI 53701 -2509 APPLICATION
Wisconsin Statues 101.63, 101.73
Q Constr 11] HVAC ❑ Elec ❑ Plbg Q Erosion El Other:
Owner's Name Mailing Address Telephone No.
DEL TRITT Oshkosh WI 54901 - 0000
Contractor: 13 Con • Elec U HVAC ❑ Plbg Lic/Cert # Mailing Address Telephone No.
DEL TRITT CONSTRUCTION 665731 6228 COUNTY RD N PICKETT WI 54964 - 9533 589 -4209
Contractor:. Con Q Elec . HVAC In Plbg Lic/Cert # Mailing Address Telephone No.
D&A ELECTRIC 260797 P 0 BOX 258 DALE WI 54931 - 0258 (920) 779 -0448
Contractor:. Con • Elec 0 HVAC II Plbg Lic/Cert # Mailing Address Telephone No.
UNKNOWN ? ??
Oshkosh WI 54901 - 0000
Contractor:. Con • Elec . HVAC 0 Plbg Lic/Cert # Mailing Address Telephone No.
RASMUSSEN PLUMBING 1914 GREENBRIAR TRL OSHKOSH WI 54904 - 8887 920 - 233 -6747
Lot Area
S.. ft. 1/4, 1 /4,Section ,T N,R E(or)W
Building Address Subdivision Name Lot No. Block No.
1842 MICHIGAN ST Smith Grovee Land Replat
Zoning District(s) Zoning Permit No. Front ' IiiIM® Right
i 1
u oe» °li 47 w . q . ; m 7 <tio
Q New ❑ Repair 0 Single Family Entrance Panel Q Forced Air Furnace Nat. Oil Elec. Solid Sola
❑ Alteration El Raze E] Two Family Size: 100 am. ❑ Radiant Baseboard or Panel Fuel Ga-
❑ Addition ❑ Move ❑ Garage Service: ❑ Heat Pump Space Htg 0 ❑ ❑ ❑ ❑ ❑
❑ Other (print): ❑ Overhead ❑ Boiler Water Htg 0 - ❑ ❑ ❑ ❑
❑ Other 0 Underground Q Ce ntral Air Conditioning
Other = Dwelling unit will have 3 kilowatt or
more installed electric space heating equip.
. ... S Constructed io 0 Co ncrete c ° �„it'':'::','' Infiltration control option is: 12 Full sealing
Unfinished ❑ Manufactured ❑ Masonary Sewer
Treated Wood joints.
❑ Blower door test. ❑ Exterior
Basement 1050 Sq. ft. 7 ffi : Q Municipal of air infiltration barrier.
Living Area 1050 Sq. ft. 0 1 -Story ❑ Other � �� ❑ Septic o
2-Story .
Garage 484 S q' ft. El ❑ ry < Permit No. Envelope 20829 BTU /HR
Seasonal
Other � `',� � �` *� �� ���� Infiltration 12950 BTU /HR
Permanent �
❑ Other Q Municipal Utility •°
Q Plus Basement ❑ Private On -Site Well $82,000.00
The applicant agrees to comply with all ble codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, expr- . impli- s 1- I -. - rtment or nicipality; and certifies that all the above information is - curate.
APPLICANT'S SIGNATURE _ ` 1a' DATE SIGNED (-
APPROVAL CONDITIONS T is permit is issued pursuant to the following conditions. Failure to comply may result in s pens.
revocation of this permit or other penalty
See standard conditions of approval
❑ Town ❑ Village 0 City ❑ County ❑ State of: Municipality Number of Dwelling Location:
, City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Q Construction . a_ >.
Inspection 1 HVAC Name Brian Noe
MI
Wis. Permit Seal $30.00 Electrical
- Plumbing Date 05/10/2001
Other
0 Erosion
Total $105.00 in 264790 Cert. No. 70266
BD -582 (R. 07/92)
OSHKOSH GRADE STAKE FORM
ON THE WATER Grade Stake Number 6522
Name DEL TRITT Address 1842 MICHIGAN ST Create Date 05/10/2001
Lot Block Ward
Subdivision Smith Grovee Land Replat Zone
Street Number Lot Dimensions Sidewalk Existing
Building Grade Elevation Stakes Set At Site 05/15/2001 Set By KN 565 /55
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to ha - grade established before excavation
has commenced.
. i .,....,
a w .,
, .5. 0 i, .
1 ' 1rij 2 a.ilcia .4 J e' A --....- u) 4 ,
N 1 '
1 , e E
' 2
2 10
1 o d.
��-
M r•
.0'0(-
0 t1 1
X0'09 .0"09 4-4 "
.0'09 • 0"09 10 " 09
L -rovccip
r o -,,
§siik.'-' V 1 V .s F. t om, i r .4..., ,
....,
„.„ -7".. 1.• ' '4' ' .''''
s
w,
\ n
fl r � 4
.
, kik -
, �r,,
t J + 2 2' � ALT w�
:8 I tE8 I 1 .,,,, . cr
N M � y � .
, W �+
, (. sr Fsn�cc l (V 1V
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address t t ' Z- rmc-k � �� Permit # Y // O
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire- resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness ( 1/20-inch) and backed by solid wood or
drywall with the joints staggered.
3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
6. All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
8. Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
•
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is
required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion
control measures must be maintained until the lawn is established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re- inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re- inspection fee per inspection.
15. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd fl • • .
/ /
Signature o /Appicant: 4 /C�� 2tate: