HomeMy WebLinkAbout0089259-Plumbing (interior) CITY OF OSHKOSH No 89259
OSHKOSH PLUMBING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 1842 MICHIGAN ST Owner DEL TRITT Create Date 05/17/2001
Contractor RASMUSSEN PLUMBING Category 410 - Residential- Interior Plan
Bathtub 1 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 2 Lndry Stndp Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Valuation $6,000.00 Plan Approval $0.00 Permit Fees $72.00
Issued By +(V) Date 09/17/2001
❑ Permit Voided
In the performance of this work, I agree to perform all work pursuant to rules goveming the described construction.
Signature Date
Agent/Owner
Address 1914 GREENBRIAR TRL OSHKOSH WI 54904 - 8887 Telephone Number 920 - 233 -6747
Plumbing Permit Work Card
Job Address 1842 MICHIGAN ST Permit Number 0. ,2.57 Create Date 05/17/2001
Owner DEL TRITT Contractor RASMUSSEN PLUMBING
=gory 410 - Residential- Interior Plan Value $6,000.00
bathtub 11 Shower / 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain / 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory i/ 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 1/ 2 Lndry Stndp — 1 - 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink P 1 Disposal /1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher j 1 Beer Tap Sculry Sink Wash Ftn
Water Heater / 1 Sump Pump 1 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn.Type
Sanitary Sewer iA J y;07
r /
Storm Sewer r , 7
Water Service
Date 00 /00 /0000 Type Inspector u Approved
■ Yj t-P
0 .. i llt// PC \/6
Sent 6/27/01 7:02 AM Page 1 of 1
Rasmussen Plumbing, Inc.
Jeff Rasmussen
Master Plumber #223251
1914 Greenbriar Trail
Oshkosh, WI 54 904 -8887
Phone (920) 211
Fa\ available bw must call office first
(
s p ��-- - TA`tr
/of 1 -; - `1 11-r) - - 1 k ;
/- 9,st RAJLL . lit -ti 7n
/- -eta- O r e
1- Tit
Ltr
LA-0s
S 1. u rear 51-4- -`'
k . r f!BoF.
Zo roc.— r�.����ttttt Y r r te`
L
f. s --9 r4,4113
Lai
c ODD
■
Fixture Listing
Date' June 27, 2001
Name: ; g—If S St..t..-JC--"^' 1 l4 1i Project: , riu s F
Street q
( t 1 1 (A-t44 4 r-: kA., Street: ig 72 ivt i 4 4. i 7
City: 6 .514 CC City: Oft / Cal t?
Non Public Use Fixtures
Hot Cold Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Uishwushing Machine 1.00 00 1.00
2 !lose Rib, 1/2" diameter 00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
1 Bathtub, lavatory and water closet - FT group 2.00 3.50 4.00
1 Shower Stall, lavatory and water closet FT - group 1.50 3.00 3.50
Total Water Supply Fixture Units 6.50 14.50 17.50
12.5 Gallon per minute demand of the building. Predotninatly Flush Tank
34.5 Pressure available for uniform Loss. For the table use - 35.0
Maaimun Allowable load for Copper Tube Type M, ASTM 688
Nominal Sire 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual 1. 1). .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in 11 per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6.5 0 12.5 21.5 32 45 79 121 174 303
Maximutn FM WSFI1 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 8 0 17.5 34 60 110 270 480 776 1833
1 U0 1 abed WV ES :9 1019/! luaS
•
WATER DISTRIBUTION DATASHEET
Date: June 27, 200 I
Name: D —rit-1.
T_ Project:
Street: J C L w"ew.S ✓� •x. 1 Street: t /"C.• i
City: City 4044 K,.
1. _ 12.5 Gallon per minute huiding demand, predominatly Flush Tank.
2. 53.0 Low pressure at the Main in Street.
3. .9 Lb loss from a 2_0 ft difference in elevation from Main in Street to the Water Meter.
4a. .9 Lb loss from a 15.0 ft l'' Copper Tube Type K ASTM 1388 water service from the Main in Street to the curb stop.
Pressure loss deteminc d using a C value of 130 , inside diameter of .995 and a velocity of 5.2 ft per sec.
4b. 4.3 Lb loss from a 70.0 ft 1" Copper Tube Type K ASTM 1388 water service from the curb stop to the Water Meter_
Pressure loss determned using a C value of 130 , inside diameter of .995 and a velocity of 5.211 per sec.
5 2.3 Lb loss from a 3 /4in Meter .
6. _ 44,6 Lhs of pressure available at the Water Meter. This value is entered in (R) below
The (A) value listed below is determined by using the following formula, then rounding the result up.
A = B- (C +D}+E) x 100
F
A. 35 Pressure available blur uniform loss (psi /100 feet of pipe).
H. 44.6 Lhs of pressure available at the Water Meter.
C. 20.0 Pressure needed at the controlling fixture.
D. 3.9 Lb loss resulting from a 9.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a serving the controlling fixture.
F. 60.0 Ft Developed length from the 40.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable toad for Copper Tube Type M, ASTM 1388
Nominal Sive 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in tt per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Crpm 6.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 8 0 17.5 34 60 110 270 480 776 1833
l to l abed Wbf 95 :9 10/9/t luaS
Rasmussen Plumbing, Inc.
1914 Greenbrier Trail
Jeff Rasmussen Oshkosh, WI 54904-88117 Master Plumber 4223251
Phone (920)233-6747
Fax (920)213 -6747
Per our conversation on 11/28/00 that I am able to take the water
pressure frorobsi or neighbor of jobsite to get a pressure number to
figure the water calculation worksheet:
The water pressure was taken on 6 - a - 7- 0 (
at C�� is iyfr")
and the pressure is at 53
4 I
1 to l eb Os :9 10/911 lueg