HomeMy WebLinkAbout14600-Plumbing (12/05/2008) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER OSHKOSH WI 54903 -1130
Issue Date 12/5/2008 Compliance Date 1/4/2009 Compliance No
Address 37 STONEY BEACH RD
Name Address City State Zip Code
Sent to u Owner STEVEN D HAMP 37 STONEY BEACH RD OSHKOSH WI 54902 -7240
Li Required for Occupancy Occupancy
Introduction
An inspection of the plumbing on 9/11/08 revaled the following violations:
Item # 1 Code COMM 84.20 Compliance No Compliance Date 01/04/2009
Description Notice was left onsite during inspection and also expalined to plumbing contractor verbally regarding water closet clearances. Inspector has not
received notice that the required 15" center to side wall or 30" center to center clearances for the 2nd floor water closet have been corrected.
12/05/2008 The final inspection will not be approved until water closet clearance per the Wisconsin Uniform Plumbing Code is met.
Last
Updated
Item # 2 Code COMM 84.20 Compliance No Compliance Date 01/04/2009
Description Safing is required to be installed per the Wisconsin Uniform Plumbing Code and inspection requested by the installer prior to cover. The final
inspection will not be approved without the 2nd floor shower meeting all requirements of the Wisconsin Uniform Plumbing Code.
12/05/2008
Last
Updated
14600 Page 1 of 2
INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER
OSHKOSH WI 54903 -1130
Issue Date 12/5/2008 Compliance Date 1/4/2009 Compliance No
Address 37 STONEY BEACH RD
Name Address City State Zip Code
Sent to u Owner STEVEN D HAMP 37 STONEY BEACH RD OSHKOSH WI 54902 -7240
Introduction
U Required for Occupancy Occupancy
An inspection of the plumbing on 9/11/08 revaled the following violations:
Item # 3 Code COMM 82.40 Compliance No Compliance Date 01/04/2009
Description Water heating systems shall be sized to provide suffcient hot water to supply both the daily requirements and hourly peak loads of the building.
The owner /purchaser of the tankless water heater intended to be installed will be required to assist the plum ber and HVAC contractor to insure
12/05/2008 the water heater will meet the requirements of the plumbing code and to also meet the manufacturer's installation requirements.
Last
Updated
Summary You shall be required to comply and call for reinspection before any work is covered. Failure to comply will may result in
penalty per local ordinance.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 1/4/2009
Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the
nature of what needs to be inspected.
Signature Date
Inspected by: Paul Wolf 236 -5052 pwolf@ci.oshkosh.wi.us
I hereby certify the violations listed on this report , ected in compliance with the applicable codes.
Print Name tUI ?V , G Company
Signature I
Date
Also Sent to: u Bldg -
�J Elec -
u HVAC -
U Plbg MOREMAN PLBG & HTG SERVICE INC PO BOX 1325 OSHKOSH WI 54903 -1325
U Designer -
u Other -
p Inspector Nicole Krahn