HomeMy WebLinkAbout15122-Plumbing (06/05/2009) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER OSHKOSH WI 54903 -1130
Issue Date 6/5/2009 Compliance Date 7/5/2009 Compliance No
Address 117 E NEW YORK AVE
Name Address City State Zip Code
Sent to u Owner ALMOST EVERYTHING LLC PO BOX 121 THERESA WI 53091 -0000
HI Required for Occupancy Occupancy
Introduction
An inspection of the plumbing on 6/3/09 revealed the following violation(s):
Item # 1 Code Comm 82.40(4) Compliance No Compliance Date 07/05/2009
Description A control valve shall be installed in the supply piping to each water heater, water treatment device, plumbing appliance and piece of
equipment. Dual use angle stop serving kitchen sink and dishwasher is prohibited.
06/05/2009
Last
Updated
Item # 2 Code Comm 82.40(7) Compliance No Compliance Date 07/05/2009
Description Fixture supply connectors serving kitchen sinks may not exceed 24" in developed length upstream of a plumbing fixture or the body of a faucet.
Supply connectors at kitchen sinks exceed 24 ".
06/05/2009
Last
Updated
Item # 3 Code Comm 82.10(1) Compliance No Compliance Date 07/05/2009
Description Plumbing shall be installed and maintained in such a manner to protect the health, safety and welfare of the public or ocupants. Tub spout at
1st floor bathtub is extended 1" from the tub wall. This will allow water to weep behind wall and cause probable mold or rotting of structure.
06/05/2009
Last
Updated
15122 Page 1 of 2
0 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH CORRECTION NOTICE PO Box 1130
ON THE WATER OSHKOSH WI 54903 -1130
Issue Date 6/5/2009 Compliance Date 7/5/2009 Compliance No
Address 117 E NEW YORK AVE
Name Address City State Zip Code
Sent to Lā Owner ALMOST EVERYTHING LLC PO BOX 121 THERESA WI 53091 -0000
Introduction
HI Required for Occupancy Occupancy
An inspection of the plumbing on 6/3/09 revealed the following violation(s):
Item # 4 Code Comm 82.38 Compliance No Compliance Date 07/05/2009
Description Owner shall provide evidence of clearwater and foundation drain separation from sanitary sewer. Clearwater sump is currently pumping to a 4"
standpipe at front wall of home near the building cleanout.
06/05/2009
Last
Updated
Summary You shall be required to comply and call for reinspection prior to occupancy.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 7/5/2009
Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the
nature of what needs to a inspected.
Signature Date r . f * 6 9
Inspected by: Paul Wolf 236 -5052 pwolf@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: _ f Bldg
u Elec
HVAC
4 Plbg SBS PLUMBING LLC 4635 RED FOX RD
OSHKOSH WI 54904 -7784
Lf Designer
L Other
Inspector ā -
15122 Page 2 of 2