HomeMy WebLinkAboutFinal (electric) - 03/19/2001 INSPECTION SERVICES DIVISION 0 DEPARTMENT OF COMMUNITY DEVELOPMENT OSHKOSH CITY OF OSHKOSH, WISCONSIN ON THE WATER CORRECTION NOTICE Issue Date 03/19/2001 Compliance Date 04/18/2001 Compliance No Address 2480 MINERVA ST Inspected By Brian Noe Name Address City State Zip Code Sent to IJ Owner I RONALD W RONSON 2480 MINERVA ST OSHKOSH WI 54901 -1546 U Contractor HOEHNE ELECTRIC 621 E ONTARIO ST OMRO WI 54963 - U Other MARC'S REMODELING OSHKOSH WI - IJ Inspector u Required for Occupancy Occupancy SFR Notice • First 0 Final 0 Other Introduction At the time a final inspection was made on 2/15/01 it was agreed that the numerous electrical violations would be addressed by the electrical contractor who had a permit for the remodeling that was done.As of this date the following violations have not been corrected to our knowledge Item # 1 Code NEC 410 Compliance No Compliance Date 04/18/2001 IMMEDIATELY Description The lights located under the bar do not meet clearance requirements and are not installed per there listing requirements. Item # 2 Code Comm 16 Compliance No Compliance Date 04/18/2001 IMMEDIATELY Description The GFCI adjacent to the bar is not properly functional @@ Item # 3 Code NEC 240 -83 Compliance No Compliance Date 04/18/2001 IMMEDIATELY Description All cirrcuit breakers in the new sub panel are required to be properly tabled. @@ Item # 4 Code NEC 300 Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description The floating rec box for the wash machine is requird to be properly installed. All electrical equiptment is required to be properly suported, and secured. @@ Item # 5 Code NEC Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description The feeder cable for the sub panel is required to be properly secured Page 1 of 4 �1 INSPECTION SERVICES DIVISION ( /�. DEPARTMENT OF COMMUNITY DEVELOPMENT OSHKOSH CITY OF OSHKOSH, WISCONSIN ON THE WATER CORRECTION NOTICE Issue Date 03/19/2001 Compliance Date 04/18/2001 Compliance No Address 2480 MINERVA ST Inspected By Brian Noe Name Address City State Zip Code Sent to 12.1 Owner RONALD W RONSON 2480 MINERVA ST OSHKOSH WI 54901 -1546 u Contractor I HOEHNE ELECTRIC 621 E ONTARIO ST OMRO WI 54963 - 2J Other MARC'S REMODELING OSHKOSH WI - L J Inspector HI Required for Occupancy Occupancy SFR Notice 0 First 0 Final 0 Other I Introduction At the time a final inspection was made on 2/15/01 it was agreed that the numerous electrical violations would be addressed by the electrical contractor who had a permit for the remodeling that was done.As of this date the following violations have not been corrected to our knowledge Item # 6 Code NEC Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description The cable feeding the dryer receptacle is not properly installed Item # 7 Code NEC 300 Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description The flouresent light is not properly wired - no connector installed on fixture where cable enters. Item # 8 Code NEC 300 Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description All cable are required to be secured within 12 inches of entering the main service panel @@ Item # 9 Code NEC 110-16 Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description Code required working clearance is required to be provided in front of service and sub panel. Min 3 feet in front. @@ Item # 10 Code NEC 300-4 Compliance No Compliance Date 04/20 /2001 IMMEDIATELY Description NM cable is not permitted to be stappled to the bottom of floor joists unless provided with physical protection. Page 2 of 4 INSPECTION SERVICES DIVISION 10 DEPARTMENT OF COMMUNITY DEVELOPMENT OSHKOSH CITY OF OSHKOSH, WISCONSIN ON THE WATER CORRECTION NOTICE Issue Date 03/19/2001 Compliance Date 04/18/2001 Compliance No Address 2480 MINERVA ST Inspected By Brian Noe Name Address City State Zip Code Sent to H Owner RONALD W RONSON 2480 MINERVA ST OSHKOSH WI 54901 -1546 U Contractor HOEHNE ELECTRIC 621 E ONTARIO ST OMRO WI 54963 - U Other MARC'S REMODELING OSHKOSH WI - u Inspector Li Required for Occupancy Occupancy SFR Notice • First O Final O Other Introduction At the time a final inspection was made on 2/15/01 it was agreed that the numerous electrical violations would be addressed by the electrical contractor who had a permit for the remodeling that was done.As of this date the following violations have not been corrected to our knowledge Item # 11 Code NEC Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description The receptacle to for the water softner is not properly wired and has damage to the UFcable supplying it, and no cover plate. @@ Item # 12 Code NEC 220 Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description Service Toad calc is required to show the addition of the sub panel has not increased the load beyond code allowable load for the exisiting service. @@ Item # 13 Code NEC 110-26 Compliance No Compliance Date 04 /20/2001 IMMEDIATELY Description The dryer vent is not permitted within the dedicated space for the service and sub panel. Item # 14 Code Comm 21.08 Compliance No Compliance Date 04/20 /2001 IMMEDIATELY Description All penetrations in floor are required to be firestopped. @@ Page 3 of 4 el) INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT OSHKOSH CITY OF OSHKOSH, WISCONSIN ON THE WATER CORRECTION NOTICE Issue Date 03/19/2001 Compliance Date 04/18/2001 Compliance No Address 2480 MINERVA ST Inspected By Brian Noe Name Address City State Zip Code Sent to Owner RONALD W RONSON 2480 MINERVA ST OSHKOSH WI 54901 -1546 U Contractor HOEHNE ELECTRIC 621 E ONTARIO ST OMRO WI 54963 - u Other I MARC'S REMODELING OSHKOSH WI - u Inspector U Required for Occupancy Occupancy SFR Notice • First 0 Final 0 Other Introduction At the time a final inspection was made on 2/15/01 it was agreed that the numerous electrical violations would be addressed by the electrical contractor who had a permit for the remodeling that was done.As of this date the following violations have not been corrected to our knowledge Item # 15 Code NFPA 54 Compliance No Compliance Date 04/20/2001 IMMEDIATELY Description The unused gas line is required to be capped. @@ Summary Please make corrections and call for a reinspection prior to compliance dates. If you have any questions I can be reached at (920) 236 -5051. DEFICIENCIES MUST BE CO; • - CT AND APPROVED BEFORE CONCEALMENT. CALL (920) 236 -5050 FOR INSPECTION. Signature • _ Date (._34I /) • Page 4 of 4