HomeMy WebLinkAbout0072939-Plumbing (interior) ie CITY OF OSHKOSH No 0072939
OSHKOSH PLUMBING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 1934 MINERVA ST Owner DEL TRITT CONSTRUCTION Create Date 05/05/99
Contractor RASMUSSEN PLUMBING Category 410 - Residential- Interior Plan
Bathtub 1 Shower 1 Ejector /Grind 0 Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 2 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Valuation $6,000.00 Plan Approval $0.00 Permit Fees $96.00
Issued By Date 09/16/99
❑ Permit Voided
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature Date
Agent/Owner
Address 1914 GREENBRIAR TRL OSHKOSH WI 54904 - 0000 Telephone Number 414 - 233 -6747
Plumbing Permit Work Card
Job Address 1934 MINERVA ST Permit Number .0Og99e9 9 gi3 Create Date 05/05/99
Owner DEL TWIT CONSTRUCTION Contractor RASMUSSEN PLUMBING
Category 410 - Residential- Interior Plan Value $0.00
htub / Shower / Ejector /Grind / 1 Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain i 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory // Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet / / Lndry Stndp / Clothes Wshr Ice Chest FIr!Wst Sink Int Grease Trap
Res. Sink / Disposal Q Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher / Beer Tap Sculry Sink Wash Ftn
Water Heater Sump Pump / Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
WrA C/4LC- c r / 3 7 i q /
Size Material Type # Conn. e
Sanitary Sewer 11J
6 T 'c O f S'C
Storm Sewer
....ier Service
Date Type Inspector U Approved
el) CODE ENFORCEMENT DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
OSHKOSH CITY OF OSHKOSH, WISCONSIN
ON THE WATER CORRECTION NOTICE
Issue Date 8/3/1999 Compliance Date 9/2/1999 Compliance No
Address 1934 MINERVA ST Inspected By PLUMBING INSPECTOR
Name Address City State Zip Code
Sent to ✓f Owner DEL TRITT CONSTRUCTION 421 W BENT AVE OSHKOSH WI 54901 -2125
u Contractor RASMUSSEN PLUMBING 1914 GREENBRIAR TRL OSHKOSH WI 54904 -
r f Other -
J Inspector
u Required for Occupancy Occupancy Notice 0 First O Second 0 Final 0 Other
Introduction
An inspection of the plumbing on 8/3/99 revealed the following violation(s):
Item # 1 Code OMC 20 -8 (A) Compliance No Compliance Date 9/2/1999 IMMEDIATELY
Description
NO RECORD ON FILE OF OBTAINING PLUMBING PERMIT (REMIT $136.00 DOLLARS TO THE CITY OF
OSHKOSH - - -DBL PERMIT FEE).
Item # 2 Code COM82.20(1) Compliance No Compliance Date 9/2/1999 IMMEDIATELY
Description
NO RECORD ON FILE OF RECEIVING WATER CALCULATION WORK- SHEET.
Item # 3 Code COM82.30(10) Compliance No Compliance Date 9/2/1999 IMMEDIATELY
Description
DISCHARGE PIPE FROM THE SEWAGE PUMP SHALL BE CONNECTED TO THE HORIZONTAL DRAIN BY
MEANS OF A WYE PATTERN FITTING. THE BOTTOM OF THE WYE BRANCH OF THE FITTING SHALL BE
LOCATED ABOVE THE HORIZONTAL CENTER LINE.
Page 1 of 2
CODE ENFORCEMENT DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
OSHKOSH CITY OF OSHKOSH, WISCONSIN
ON THE WATER CORRECTION NOTICE
Issue Date 8/3/1999 Compliance Date 9/2/1999 Compliance No
Address 1934 MINERVA ST Inspected By PLUMBING INSPECTOR
Name Address City State Zip Code
Sent to u Owner DEL TRITT CONSTRUCTION 421 W BENT AVE OSHKOSH WI 54901 -2125
U Contractor RASMUSSEN PLUMBING 1914 GREENBRIAR TRL OSHKOSH WI 54904 -
Other
u Inspector
j Required for Occupancy Occupancy Notice • First O Second 0 Final 0 Other
Introduction
An inspection of the plumbing on 8/3/99 revealed the following violation(s):
Item # 4 Code OMC 20 -8 (A) Compliance No Compliance Date 9/2/1999 IMMEDIATELY
Description
REMIT TO THE CITY OF OSHKOSH $25.00 DOLLARS (RE- INSPECT FEE).
Summary
You will be required to call for re- inspection no later than 9/2/99.
You will be required to make payment to the City of Oshkosh no later than 9/2/99.
DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL (414) 236 -5050 FOR INSPECTION.
Signature Date
Page 2 of 2
J` 34-( GA t) h -
WATER CALCULATION WORKSHEET
Information Needed for Water Service Sizing
1. / ( Demand of building in gallons per minute.
2. Low pressure at main in street (or at external pressure tank).
3. Difference in elevation from main to meter (or external pressure tank to building
control valve).
4. ___ Size of water meter (if applicable).
5. S Developed length from main to meter (or external pressure tank to building
control valve).
You Must First Find the Available Pressure After the Water Meter
(or at building control valve). To obtain this pressure, you must:
6. 3 Find pressure loss due to friction in 1 // inch water service.
7. r Find pressure loss due to elevation, main to meter (or external pressure tank to
building control valve). Multiply the difference in elevation by .434 p.s.i. /ft.
8. ' Find pressure loss due to meter. (from manufacturer or AWWA).
9. 57 Subtract the loss due to friction (Step 6), loss due to elevation (Step 7), and loss
due to meter (Step 8) from the low main pressure (or low pressure at external
pressure tank). This calculation is the available pressure after the water meter (or
at the building control valve). This answer is entered in Line B, below.
Information Needed for Water Distribution Sizing
Using the following formula, find the pressure available for uniform loss (p.s.i /l00' of pipe)
A (C +D + E)x 100
WHERE: F
. A. 2 r Pressure available for uniform loss (p.s.i. /100' of pipe).
B. 57 Available pressure after water meter (at the building control valve or low pressure
at internal pressure tank). (See item 9, above).
C. 2 ` _ Pressure needed at controlling fixture.
D. 7 Difference in elevation between water meter (building control valve or internal
pressure tank) and controlling fixture in feet x .434 p.s.i. /ft.
E. Pressure loss due to water softeners, water treatment devices, instantaneous
water heaters and backflow preventers. Conventional water heaters usually do not
have a pressure loss.
F. / p5 Developed length from water meterjbuilding control valve or internal pressure
tank) to controlling fixture in feet "' ° x 1.5.
With pressure available for uniform loss, go to applicable table for distribution sizing.
SAD -6479 (R. 08/88)
1 c l 3: N€./- 0 a s t, b .z. I 7A. << {
Jt jL 1/4'VL--s - d � T Nc _
2 37_0y)
C___ /--( I____L?-13-(
11 (i3 / ( /er
Y` l
1— D( `E'S1).e Sc,
\ - D ' , ( i
//, f ‘,)-- /-
y, 5 G U = 1/ G-Pr