Loading...
HomeMy WebLinkAbout0064855-Building (shed) CITY OF OSHKOSH No 0064855 OSH' OSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER - ( Job Address 1150 LAAGER LA Owner Create Date 6/30/98 Designer Contractor OWNER Category 151 - New Utility Buildings -Sheds (Reside Plan Type 0 Building 0 Sign 0 Canopy n Fence () Raze Zoning Class of Const: Size 8'x8' Unfinished /Basement Sq. Ft. Rooms Height Ft. u Projection Finished/Living Sq. Ft. Bedrooms Stories Canopies Garage Sq. Ft. Baths Signs Foundation Poured Concrete O Floating Slab O Pier Q Other Concrete Block O Post O Treated Wood Occupancy Permit Not Required Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use/Nature SF R/ Constructing a 85x8' shed in the rear yard. 1 he shed will be anchored to resist uplift. of Work HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuatio $750. 00 Plan Approval $0.00 Permit Fee Paid $10.00 Park Dedication $0.00 Issued By: �`( Y / �,,...„ Date 6/30/98 Final /O.P. Li Permit Voided In the performance of this ork I agree to p orm - I work pursuant to rules governing the described construction. Signature / QA Date (•- JV ?? Agent/0 - ner Address 150 LAAGER LA 0�I'd H WI 54901 - 6694 Telephone Number (ED ZONING /LAND USE COMPLIANCE CHECKLIST OSH'OSH ON THE WATER Name LAWRENCE B/S A SCHMIDT Address 1150 LAAGER LA Create Date 06/30/98 Construction Data New Construction Q Addition Q Alteration Type of Construction (i.e. fence, pool, parking lot, sign, etc. SFR/ 85x8' shed in the rear yard Compliance Checklist Deficient Comments Li Use lI Lot Width Li Lot Area U Lot Area Per Family LI Hood Plain t-i Front Yard Li Front Yard Side Street 11 Hear Yard Li Side Yard , :_�' U Building Area Li Parking Standards I=FDff:StietWdin g an ar s U Vision Clearance Li Transitional Yard Standards U Landscape Standards Li Height Li Conditions of Approval 11 Compliance with P.C. or BZA Conditions of Approv Li Signage Standards U Urainage Plan Review Authority As per Section 30 -5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc., when the use is conforming and when no change is proposed. Approved 0 Denied I Plan Commission Action Required Vanance(s) Required Reviewed By Nicole Krahn Date 06/30/98 v\ d o � Cpl _ T • OD QJ Z 0 c g 11 1P 1P 1P 4P 4P 1P 4P LP 01 4P 1P 4 4 4P 1P 4P 4 1P tr N 10 J 01 01 01 4 r 0 o 10 10 10 10 10 OD CO CO 01 CD 11 r 1D W CO 1• U1 O (N O 01 01 1P r N N N N 00 11 00 W 4 4 N 10 CO 4 N U1 iP U1 1P 4, 10 J 01 01 0 fD a Z z Z z z z z z Z z z z z z Z z Z z f+ N H H H H H H H H H H H H l- H H H H H CD c+ x 0 x x x x 0 0 CC 0 5 0 0 0 0 0 0 CC ri 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r r r r r r r r r r r r r r r r H r Z a a a Pr f 11 N Fi N lJ1 N U1 lT U1 LP ln In U1 l71 U1 l71 LP U l ! 1 lT1 LP ll1 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 'JO U1 01 U1 01 tT 01 U1 LP U1 U1 01 U1 01 U1 U1 U1 U1 01 fD \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ 0 10 01 W 41 W W W W N N N N N N N N N N N a C O O 0 0 0 0 0 10 10 l0 10 1D l0 10 10 l0 10 10 f + CD \ - \ \ \ \ \ \ fD N 10 10 l0 10 10 l0 10 b 10 10 VD l0 10 l0 10 10 l0 LO ft CO CO CO CO CO CO CO CO 00 CO CO CO CO N CO 00 CO CO (D a 0 H N r r r U1 U1 r r N r r N N L71 U1 r ly N 0 01 01 11=. 14 U1 01 1D N 171 U1 r r .P J N N f•t r 1T 1P P.. 4 0 J 01 0 N 11 W 10 10 01 r J F+ = 01 W r r W U1 J 4 U1 r -0 N r r 01 1 D 01 CO z 01 0 10 CO 0 C) l0 IV 07 U1 10 N N r J 4 J 01 L ro ro ID O 0 LO O X >4 M W r 00 0 r 0 10 g 0 0 0 0 0 0 X o 0 01 C r ~ 1 D D 1 t�royy a n rt 1s K 0 N 0 O Z .. 0 H ( fD Z P p 0 0 a ro 0 fn 1 17 H H 1f�n O DJ G7 CD fn '] t Z Z Z Do C 0 DO 0 u1 �y 1 110 Ni r 0 70 1 8 C7 tai t+7 C7 x P H t CU z> 0 0 0 r O N O J r t`j m H 0 ti 0 H r r r r rro H 0 f DD cn Z1 Z H M 7J t+J = tl7 tt C+] th ' ] 0 0 DJ r 0 a s 3 �ro H , m n '0' c i m 0 Z 01 x y Z H 1 •=1 m cA 0 0 �C CD H 1 1 0 d i H Z ;U 10 y t] t�] ro Y• 1-I p P C � 3 3 0 H H u c�ni CD v Z 'Cl p • t� y0 r 11:1 z 111 r r 0 0 01 x 0 Z 0 p a N 0 f+ U1 r 1- C 01 r 10 l0 N N 01 01 0 N N 4=. N N N N U1 01 r• r• r- r• H• N- r• H• r• H• r• H. H• r• P. H. N• r• ro 0 ro rt CI' rt rt el - rt el* et el* rt rt ft rt CI' rt rh rt f* 0 r r r r r r r r r r r f•+ r r r 1-+ r 1-+ C f 1p w w 1N w w w w w w w 10 w w 01 w 0) w w CD CD CO J 01 01 U1 co 0 10 10 ■D l0 CO CO CO J J J 01 0 CO 4 W W CO CO r CO 01 N N 1D CO CO 10 10 10 W 1 1 CO J N N CO tD 01 10 J U1 4 CO W W (1) P1 01 r G. CD 11 1 0 01 N CO N • ■ • HANDY. ' . HOME _ PRODUCTS WOODEN S BUILDING It's Easy...It's Handy CAMBRIDGE 8' x 8', 8' x 12' and 8 X 16 Patent Pending 12/97 HANDY CHECKLIST & ASSEMBLY INSTRUCTIONS BEFORE YOU BEGIN: FIRST... Read these instructions thoroughly before you begin assembly. Assembly is easiest if you follow the steps in the order shown. In a drawing, a dotted line represents a part hidden from view (like a part under a panel). ❑ CHECK ALL PARTS Compare the parts you have to the list on page 2. If a part is missing, circle the part in question and call us toll -free at 1- (800)- 221 -1849. Ask for a Consumer Help -Line Representative to assist you. O ASSISTANCE REQUIRED Assistance is necessary to handle, fit, and secure some components. O SQUARENESS IS VERY IMPORTANT! Ke ing all 90° corners and 90° perpendiculars square throughout the assembly of this building will make each succeeding ste easier and is necessary to assure that all components fit together properly. O CHECK LOCAL ZONING Before erecting any.building on your property, check with your local government office regarding any local requirements. O FLOOR SYSTEM: WOOD OR CONCRETE Before assembling your building, you must first construct a floor system. We recommend using the optional Handy Home Products Wood Floor kit, or installing a 4" concrete slab floor system. (See page 4 for more on both options). O LUMBER The lumber used to manufacture this storage building has been graded in accordance with national grading rules. Framing lumber is graded for its structural integrity, not its appearance. Trim lumber is graded on one surface for its appearance. O ALWAYS WEAR OSHA - APPROVED SAFETY GLASSES THROUGHOUT THE ASSEMBLY PROCESS. OTOr.,L.S REQUIRED - -�®. ❑ Hammer O Phillips Screwdriver ' RUIN�°�'�® O Level O Step' adder / l O Pe ,cil wasswassexas ❑ T- :;e Measure , i. ik ❑ S4 ► fety Glasses �' • O OPTIONAL TOOLS (MAKE ASSEMBLY EVEN EASIER) r o Electric Drill with #2 Phillips Tip ❑ Chalk Line 4 CI Square ❑ Nail Pouch HANDY HOME . � PRODUCT_ S WOODEN STORAGE BUILDING It's Easy...h's Handy PARTS LIST: 8' X 8'CAMBRIDGE TRUSSES _ 6 - Truss Halves (Part MF) - Pre - Assembled 6 - Gusset - 3/8" x 6" x 24" REAR WALL 1 - Right Rear Wall Wood Gusset _ 1 - Left Rear Wall _ 2 - WallSupport (Part LN) -2 "x3 "x18 -1/4" _ 2 - Notched Rear Wall Interlocking Brace (Part PI) - 2" x 3" x 86 -1/2" FRONT WALLS _ 1 - Left Front Wall Panel with Door 1 - Right Front Wall Panel with Door _ 1 - Front Wall Vertical Brace (Part LN) - 2" x 3" x 18 -1/4" _ 2 - Front Wall Support (Part LN) - 2" x 3" x 18 -1/4" _ 1 - Interior Weatherstrip - 3/8" x 1 -3/4" x 69 -3/4" 1 - Over Door Trim (Part OH) - 2" x 3" x 55" Truss -half SIDE WALLS / ROOF 2 - Side Wall Panel - 44 -5/8" x 47 -7/8" Erna _ 2 - Side Wall Panel - 48" x 47 -7/8" _ 2 - Side Wall Top Plate (Part PM) - 2" x 3" x 92 -5/8" WM! __ 10 - Side Wall Stud (Part NE) - 2" x 3" x 45 -1/2" ©x ©x _ 2 - Lower Roof Panel -12 x 96 Waferboard 2 - Mid -Roof Panel - 24" x 96 "* Waferboard Barrel Bolt *Some kits may substitute 2 - 36" x 96" Roof Panels in place of the 4 Panels listed above. _ 2 - Top Roof Panel - 36" x 96" Waferboard 9 B B t _ 6 - Soffit Nailers (Part RA) - 2" x 4" x 6" E B % _ 2R/2L - Soffit End Caps - 3/4" Plywood 6 -1/4" x 7 -5/16" e 6 .1,- 4 - End Cap Filler (Part DE) - 1" x 3" x 6 -1/4" _ 2 - Fascia (Part KM) - 1" x 4" x 94 -7/8" Door Has _ 4 - Corner Trim (Part EV) - 1" x 3" x 41 -1/2" _ 4 - Corner Trim (ParfCJ) - 1" x 2" x 41 -1/2" _ 2 - Soffit Roof Panel - 5 -1/2" x 96" Waferboard • GABLE OVERHANG _ 1 - Gable Overhang Supportt Right (Part MO) - 2" X 3" X 37 -1/8" _ 1 - Gable Overhang Support Left (Part MP) - 2" x 3" x 37-1/8" 2 - Gable Roof Panel - 9 -3/8" x 36" Waferboard HARDWARE AND MISC._ 2 - Temporary Brace _ 1 - 2 -Piece Door Hasp Assembly 1 - Barrel Bolt - 1 - Package Varlotis- 3ize�Va 1 - -1/4" •Rprews _, _ - 2" `Nails „�,.r� 3" Nails 2 HANDY ® i11 PROD HO UCT' WOODEN STORAGE BUI LDING It's Easy...lt's Handy TERMS AND ABBREVIATIONS THE FOLLOWING TERMS AND ABBREVIATIONS • Plate: dimension lumber which runs ARE USED IN THESE INSTRUCTIONS AND ARE perpendicular to studs and to which studs are DEFINED AS FOLLOWS: nailed for framing • Dimension lumber: lumber ranging from 1 -1/2 • Primer: first coat of paint in a paint job that to 5 inches in thickness and up to 12 inches in consists of two or more coats. A primer paint width. Most commonly used in framing may contain sealers structure and floors • Rack: (as in "rack the frame ") removing the • Drip edge: a metal product of various shapes "twist" from a frame in order to align members which is nailed or stapled to the edges of the square and parallel roof to cause water to drip free of the building • Roofing: material —wood, metal, asphalt -type, • Gusset: a wood panel designed to attach etc. — installed on the roof panels to protect it framing members at an intersection (roof) and weatherproof the structure • Joist: one of a series of parallel framing • Roof panels: panels fastened to the rafters to members used to support floor or ceiling Toads which the shingles or other roof covering are • Level (carpenter's): tool used for determining attached true horizontal, vertical, or angular direction, • Shim: (as in "shim to the ground ") a thin by centering a tiubble in a liquid - filled tube wedge of wood or other material placed • Nails: used for general construction, having a between the floor kit frame and the ground round shaft and a flat head. Two sizes of nails to adjust relative position or level. We • are used for this project : recommend cedar shims #6d 2" nail • Sill plate: the strip of wood that lies #10d 3" nail immediately on top of a concrete foundation in wood frame construction • Nominal dimension: an approximate • Studs: one of a series of vertical supports dimension assigned to a piece of material used in wall framing as a convenience in referring to the piece • Toe -nail: (as in "toe -nail through stud into Below are nominal and actual dimensions of the floor') adjoining of components using a nail or most common lumber sizes used in our kits: screw at an angle Nominal dimension Actual dimension • Truss: a structural unit consisting of various (inches) (inches) members arranged to provide rigid support 1' x 2' 3/4" x 1 -1/2' over wide spans with a minimum amount of 1' x 3' 314' x 2 -1/2' material 1' x 4' 3/4' x 3 -1/2' • Vapor barrier: a watertight material used to prevent the passage of moisture or water 2' x 3' 1 - 1/2' x 2 -1/2' vapor into or through structural elements 2' x 4' 1-1/2" x 3 -1/2' (floors, walls, ceilings) 2' x 6' 1 -1/2' x 5 -1/2' This symbol provides you with Cei)) helpful hint on assembly. • On center: a method of indicating the spacing of framing members by stating the measurement from the center of one member to the center of the succeeding one w_. o' 3 2 pcs Part PI Rear Wall Brace z . x s x ov 1 , G 0 0 1 Pc — Left Rear Wall Panel ❑ 1 pc — Right Rear Wall Panel ❑ 2 pcs Part LN Wall Support 2" x 3" x 18 -1/4" ASSEMBLING REAR WALL ASSEMBLING REAR WALL: Y 2 -A: Assemble interlocking Rear Wall Braces (Part PI) as shown and nail together 2_A ( Pl ) with one 2" nail. a • Wall Panel 7 1 2' Nails every 8' (20 cm) (2.5 cm) Horizontal 2 -B: Position right Rear Wall Panel on vertical 2_B 't Rear Wall Brace Rear Wall Brace with exterior face up. • Left edge of Panel should be centered along length of vertical Brace. Wall Panel should overhang bottom edge of ‘0140 Vertical Erace by 1". Nail with 2" nails vertical ` every 8" along Vertical Brace. Rear Wall Bra ce 432' (110 cm) • Position bottom edge of horizontal to Bottom of ...z brace 43 -1/2" from bottom of Panel, Horizontal PI and nail with 2" nails every 8" through right wall into horizontal brace. 3' Nail 2 -C: Butt lei Rear Wall Panel to Right Wall Panel ith Trim aligned at peak. Nail in 3' (76 cm (LN) same manner as above. from Edge of Panel y �1' (2 5 cm) #� \ • Nail Trim together at peak with two from Bottom 3" rails as shown. 41---Epcangemot • Posi:ior Wall Support (Part LN) under bottom of Left Wall Panel 3" from ou'sde edge and up 1" from bottom of _ Wail Panel; narrow side should face up aga nst Wall Panel. Nail with three 2" na through panel into support as 44... ..... sh wn. • Install Wall Support onto Right Wall 2-C __ Pa' el same as above. 2-V 3' (7.6 cm) Set assembled rear wall aside for from Edge of 8 0 (3 2 pcs Part PM Top Plate 2" x 3" x 92 -5/8" El 10 pcs Part NE Side Wall Stud 2" x 3" x 45 -1/2" ❑ 2 pcs — Large Sidewall 48" x 47 -7/8" Panel ❑ 2 pcs — Small Sidewall 44 -5/8" x 47 -7/8" Panel 3-A ASSEMBLING SIDE WALLS (PM) ON 8' X 8' BUILDINGS FOR 8' X 12' AND 8' X 16' 411114411\ (NE) ` REAR BUILDINGS REFER TO SECTION 3X AT THE BACK OF THIS MANUAL. 3 - Lay Side Wall Top Plate (Part PM) on flat IIIIIIIIIIIPIIPP:..._.><2°2 5/e' surface. Measure 48" from end towards ts `'� center and mark. 161 cm) 1 cm) • Measure 24" to each side of center and / mark. 24• • Center three Side Wall Studs (Part NE) (61 ) on marks made above and secure each T' ` ' 24, 48• Stud with two 3" nails through Top � (61 cm) (122 ern) Plate into ends of Studs. _ • Place two Side Wall Studs flush with the outside edges of the Side Wall Top ' Plate. Secure both Studs with two FRONT 3" nails through the Top Plate into Two 3' the Studs. Nails Grooved 3 _ B Edge Center Stud ( 2' 2' Nail WaIN Panel Nail .0 I� (NE) (PM) \ 1' (2.5 cm) 3 - Position Large Side Wall Panel on Side ■ Wall assembly with grooved edge 2a• (19 overlapping middle stud by 3/4" as (61 cm) shown. 1C- • Top edge of Side Wall should be flush 2a'' • to top edge of Top Plate. Bottom edge (61 cm) of Side Wall should overhang Studs by 1". Nail through Side Wall into Top Plate and center Stud with 2" nails at 40NT > three corners. ' Nail Wall ' T Panel to (PM) 9 0 . 3 - C: Position Small Side Wall Panel on the TOP VIEW sqtefe Side Wall assembly with the square edge �- Edge of panel butting tight to first panel on 3 "� Grooved Edge \ � 2' Nail middle Stud. TOP PLATE • Align panel as done in step 3 -B. Nail with one 2" nail at four corners as 5 , e • CENTER STUD 20 shown. (52 Center to Edge • Measure from center of middle Stud .j 24" on center to Studs on either side. (6 «^/ ` 44%tw Nail through Wall Panel into Top Plate 24 and all Studs with 2" nails every 8 ". a�c 0 ',, • Repeat steps 3A to 3C but reverse the 24• stud layout to create a mirror image ref cm) Edge to Center wall assembly. ..< 4 1111111* ::::::::_... ,,, ,- V' Grooved Edge tiaN Flush 4111 1114* / Nai Wall FRONT T �nl TOP PLATE 7 1 STUD � LEFT SIDE ( 2.5 cm) / • Square TOP VIEW Edge ". / Grooved Edge 2 'Nad-.., ■ TOP PLATE CENTER STUD �20 5/8 Caner :Edge fr io e 24 (61 an) 24• C (61 ran) � ena 24 , ,.. , e x . Edge a Carder Grooved alt-s.- -- ___ Ed•e Flush I/ Nai `;, all T NW TOP PLATE P 1 STUD 1' (2.5 cm) RIGHT SIDE 10 o 2 pcs — Front Wall Left and Panels Right CI 3 pcs Part LN Wall Brace 2" x 3" x 18 -1/4" 4 El 2 pcs — Temporary 3/8" x 5" x 14" Braces • 3" (7.6 cm) ASSEMBLING FRONT A 2' A__=-11 3/4" (1.9 cm) WALL PANEL 4 1111 lb , (L") ASSEMBLING FRONT WALL PANEL: TOP VIE W 4 -A: Position right Front Wall Panel on flat Nails surface with exterior side up. Position im, 2 ,, _ Brace (Part LN) under right Panel with .. 1/2' narrow side against Wall Panel, 3" below (un � u 4111111 peak. Leave left half (3/4 ") of Brace ( t exposed. Nail with four 2" nails through I fn' • Panel into Brace. (3.b «") 4 -B: Lay left Front Wall Panel over exposed half of Brace and butt tight to 3/8" 3/8" Spacer spacer at bottom of right Panel and align trim at peak. Nail through top of left Wall Panel into Brace with four 2" nails. sr , Use one Part OH and two Parts LN 0 under Wall Panels, as indicated by • `� dotted lines, to temporarily level panels while assembling. • To temporarily secure the Doors to prevent opening during assembly, first • Nail make sure the two Panels are butted 3' tightly together (doors still have 3/8" 11 1 11 ‘ .;," \ .t.. ‘ gap). Now, attach two pieces of Temporary Brace along inside edges of doors with four 1-1/ screws in each • Nail trim together at peak with two 3" nails as shown. 4 -B � • Position Brace (Part LN) under bottom of Left Wall Panel 3" from outside edge and up 1" from bottom of Wall Panel; narrow side should face up against Temporary ,• , Wall Panel. Nail with three 2" nails Braces through panel into support. `I ' • • ( OH) • .. lik lik ssembled Front _ _I_t Wall aside for •-- • -• -- ------------ - - later use. 3' (7.6.6 \ (LN) from Edge prii of Panel 1' (2.5 cm) from Bottom Edge of • • Panel \ \ ' \ . \ . . N) • ---- I -, h QM)) 3' (7.6 cm) 11 0 . ERECTING SIDE & FRONT TOE - NAILING WALLS ON FLOOR 5-A ASSEMBLY �. ~ o T �� 5 -A: Position assembled Side Walls on Floor, - FLOOR with Studs setting on Floor and Wall Panels overhanging the Floor by 1" T along bottom and flush at front end (detail). Secure Side Wall Panels with 2" nails every 8" through bottom of Side Wall and into Floor. Using a 3" nail, toe -nail from the inside —� through Stud into Floor (see detail). 2• Nails � repeat for remaining Studs. • I ` • �,� If wind conditions require, use Lower •-< 92 si b: FRONT • • Roof Panel (3/8" x 12" x 96 ") as ( �3s J temporary brace for Side Walls during ,') co) assembly. Position approximately 12" g6 • (24 from rear of Wall Panels. Side 4 Wall Panel Floor .---,e ` Secure Side Wall Panel \ l 5 -B: Position assembled Front Wall on Floor to Floor with L' 1• at front, with Wall Supports setting on 2" nails every 8" (20 cm) / (2.5 cm) Floor and Front Wall panels overhanging \ \` /// the Floor by 1 ". Make sure Wall panels are flush with floor at left and right sides. Along bottom edge of front, nail t with 2" nails every 8" on each side of ' , Doors through Front Wall Panels and 5 -B �'' into Floor. / • Secure Front Wall to Side Walls by �� 2" Nails I � nailing with 2" nails every 8" through Front Wall Panel into Side Wall Studs. • On inside, nail with three 3" nails through Wall Brace into Floor. • . 7 'ci • A i 1,,,. ...„: WALL \PANEL ra. Wall 3" Nails - Brace . 1" (2.5 cm) Overhang FLOOR \ i .L T 12 o 6 pcs Part MF Assembled Truss s Ives 6" x 24 6 pcs — Gusset Extension Kit Parts 0 4 pcs Part MF Assembled Truss Halves 0 4 pcs — Gusset 3/8" x 6" x 24 ASSEMBLING ROOF TRUSSES � �or Having a helper hold parts tightly 6 Q t ogether while you nail will assure proper positioning and fit. / ASSEMBLING ROOF TRUSSES: I NSIDE OF 6 -A Position two Truss halves together on FRONT WALL PANEL Floor with peaks aligned. Push ends of Trusses into corners where Side Wails meet Front Wall aligning Truss halves at centerpoint of Front Wall Panel as shown. ��_ +� • Note: If installing building on a concrete slab, choose a flat surface to 96" � l assemble Truss halves and maintain a (244cm) 96" outside dimension at bottom ends \ Al of Truss. • Install Gusset flush to edges of Truss and nail with ten 2" nails. Turn Truss over and attach Gusset to other side in same manner. Assemble remaining Truss halves in the same fashion. _ assembled Trusses upside down 1 along Front Wall for later use. 1111.,....,_. 6 B: Place g 6 - C: Build any extender Trusses at this time v NI Nailing Pattern 4 !FY 6 -B 13 0 . ERECTING ROOF TRUSSES 3 ES 1 ON 8' X 8' BUILDINGS FOR 8' X 12' AND 8' X 16' � BUILDINGS REFER TO SECTION 7X THE 7_A �%� BACK OF THIS S MANUAL. ' I . 1 ERECTING ROOF TR USSES ' I1 � '' 7 -p: Position assembled Truss atop Side Wall i To p Plate, aligned over Stud at Front of building. Secure Truss to Top Plate � i 3° nail driven at angle as shown; secure 3•' Nail , described ab ove ali to Top Plate on both sides of building. a ' • Erect other two Roof Trusses as • � ctl I II 9 Wing dire y I / over Studs. td 0 6 pcs Part RA Soffit Nailers 2" x 4" x 6" . 8 INSTALLING SOFFIT 8-A �'4 N NAILERSON8'X8' j j l BUILDINGS FOR 8' X 12' AND 8' X 16' BUILDINGS REFER TO SECTION 8X AT THE BACK OF THIS MANUAL. 1 / 8 - A: Position the soffit Hailers on the outside I' ii % t of the side walls 1/4" down from the top edge. Position them adjacent to the wall ' .6 cm) I (0.6 studs as shown. • Fasten each soffit nailer with two 1 -1/4" screws through the Side Wall Panel from the inside. 15 9 . ERECTING REAR WALL ON FLOOR ASSEMBLY 9 -A ERECTING REAR WALL: � / t Remove temporary tem ora side wall brace before • `� erecting Rear Wall. > 9 -A: Position assembled Rear Wall on Floor opposite Front Wall, with Wall Supports 1111111101i setting on Floor and Rear Wall Panels overhanging the Floor by 1 ". Along exterior, nail with 2" nails every 8" through bottom edge of Rear Wall Panels into Floor. • Secure Rear Wall to Side Walls by nailing with 2" nails every 8" through ilk Rear Wall Panel into Side Wall Stud. WAL • Remove temporary braces from Front \PANE Doors to access inside. On inside, nail wan 3• Nails with three 3" nails through Wall Brace \,... (2.5 cm) . Supports into Floor as shown. Overhang FLOOR T 16 ❑ 4 pcs — Soffit End 3/4" x 6 -1/4" x 10 - Caps 7 -5/16" ❑ 4 pcs Part DE End Cap Filler 1" x 3" x 6-1/4" ❑ 4 pcs Part EV Comer Trim 1" x 3" x 41 -1/2" ❑ 4 pcs Part CJ Comer Trim 1" x 2" x 41 -12" 10-A INSTALLING SOFFIT END CAPS AND CORNER TRIM Two - , /a•screws E 10 -A: Attach an End Cap Filler (Part DE) to (DE) 1' 3' .End Cap 6 Eller 1/4' (DE) each Soffit End Cap as shown, using two x 1 -1/4 screws to make two each left and I two right Soffit End Cap Assemblies. soffit \ 1 1 41110 E C ap Position right Soffit End Cap Assembly End Cap 3/4• x 6 -1, 4' x 7 -5/16• flush to the lower side of front trim and �/ / fasten with two 3" nails. Right Left • Install Soffit End Cap Assemblies to I the other three corners in the same manner. Two ro\ nails I Soffit E • Cap Assembl f \\ • //'/ 10 "B 10 - Assemble the four Corner Trim pieces as shown. The 1" x 3" (Part EV) trim piece overlaps the 1" x 2" (Part CJ) trim piece. Secure with five 2" nails per trim piece. • Position the assembled trim piece over the corner of the shed and flush under the soffit end cap; 3" face should be towards the front. ° Comer Trim • Secure with six 2" nails through the trim into the walls. N. 1 • Install the remaining Corner Trim in the same manner. On the rear of the Six 2" N building the 3" face should face the rear. ° 'omer Ax3 Trim x4 11/2' Five 2' Nails (ComerTrim I (C.J) 1 x2x41 1/2" 17 0 2 pcs Part KM Fascia 1" x 4" x 94-78" . 0 , INSTALLING FASCIA ON 11 -A 8' X 8' BUILDINGS FOR 8' X 12' AND 8' X 16' BUILDINGS REFER TO SECTION 11X AT THE BACK OF THIS MANUAL. G 11 -A: Attach Fascia (Part KM) between front and rear soffit end caps. Nail each end with two 2" nails through end cap into Fascia. • Hold Fascia flush to the bottom of the r soffit Hailers and secure with two 2" . � nails through Fascia into each nailer. ' �= 1 ������ • Install Fascia to the opposite side in the Till same way. '44) 4� I /11M k I ♦♦ Fascia (KM) \ 1x4x94 7/8' 2' Nails 18 ❑ 2 pcs — Soffit Roof Panel 5 -1/2" x 96" APPLYING SOFFIT ROOF 12 -A PANELS ON 8' X 8' BUILDINGS X' FOR 8' X 12' AND 8' X 16' BUILDINGS REFER TO SECTION 12X AT THE Nails BACK OF THIS MANUAL. 12 - Position Soffit Roof Panel waferboard flush to wall and 3/16" back from front edge of building. • Nail with two 2" nails into end caps and each soffit nailer. 3/16' .— (0.5 «n) 19 ❑ 2 pcs — Lower Roof Panel 12" x 96" APPLYING LOWER ROOF PANELS ON 8' X 8' 41 BUILDINGS 13 -A FOR 8X12 AND SXI6 */117Z° � ,,' � BUILDINGS REFER TO �SECTION 13X AT THE r BACK OF THIS MANUAL. /.41 13 - Position Lower Roof Panel 3/16" back from front and rear wall trim and butted \, tightly to top edge of Sidewall Panel. Ilk • Nail front corners with 2" nails; square panel at rear and nail with 2" nails at rear corners. 3/16' (0.5 cm) • Apply Lower Roof Panel to other side of building in the same way. Roof Panel • • 20 0 2 pcs — Mid -Roof Panel 23 -7/8" x 96" - 14 APPLYING MID -ROOF 14-A PANELS ON 8' X 8' BUILDINGS / �. FOR8'X12'AND8 X16 � �� z . `. BUILDINGS REFER TO ` SECTION 14X AT THE /: / I \ 24 �� •/-1-4111111i....,_ BACK OF THIS MANUAL. (61 cm) 24' ' ' F �. � /, 14 -A: Position Mid -Roof Panel flush to Lower 1111111 (, rom Fro cm> nt ', ' Roof Panel and back 3/16" from Front ilo Trim. Nail at corners. ,, • Apply Mid -Roof Panel to other side of ' building in same manner. • Measure and mark Mid -Roof Panels on both sides as indicated. • Align trusses with marks and nail • through Lower Roof Panels and Mid- Roof Panels into all Trusses and Trim with 2" nails every 8 ". • 21 0 0 2 pcs - Upper Roof Panel 36" x 96" APPLYING UPPER ROOF PANELS ON 8' X 8' 15-A /"24%,,„ 24• BUILDINGS `61 / _ .(72 m FOR 8' X 12' AND 8' X 16' " I, ► F 'O r . -- BUILDINGS REFER TO / r-(111% SECTION 15X AT THE BACK OF THIS MANUAL. . 15 - A: Position Upper Roof Panel flush to Mid- ii iiillr6A Roof Panel and back 3/8" from Front Trim (This additional space is for mounting the Gable Overhang). Nail at front corners with 2" nails through Roof Panel into Trim. Rack panel as necessary , to square up building and maintai n 3/ 8" _ - 1 1 spacing. Secure Panel to Trusses with 2" Ra to Fit '- _ 4 1 nails every 8" into each Truss, maintaining the Truss dimensions shown. �' • Apply Upper Roof Panel to other side of 'I I 1 1 i / g bui in same manner. i fti N. I/ I 22 ❑ 1 pc Part OH Over Door Trim 2" x 3" 55" 16 ❑ 1 Pc — Interior 3/8" x 1 -3/4" x Weatherstrip 69 -3/4" ❑ 1 pc — Barrel Bolt ❑ 1 pc — Swivel Hasp TRIM AND HARDWARE (OH) 16 -A: Position Over Door Trim (Part OH) over Door, equally space overhang on sides and attach using six 1 -1/4" screws from ' < inside through Panel into Trim. i ? • Remove 3/8" Door Spacers from edge of door. i i i i 3 3 i 16 -A ' 16 - Install Interior Weatherstrip to left Door INSIDE OF BUILDING using six each 1 -1/4" screws. Top View • Install Barrel Bolt to inside of left Door Left Door y with our 3/4" screws. r�7 1;i Barrel Boft Interior ` Left Door 4 - Weather :w�x "; • Weather S Strip trip Six 1 -1/4" screws 16 -B SWIVEL HASP 16 - Install Swivel Hasp to outside of Door with seven 3/4" screws. (7) 3/4" � Screws E f e a \6) o S � EXTERIOR FRONT DOORS RIGHT DOOR 16 -C 23 0 ❑ 2 pcs — Gable Roof Overhang Panel ❑ 1 pc Part MP Gable Overhang Support (Left) ❑ 1 pc Part MO Gable Overhang Support (Right) • INSTALL GABLE OVERHANG Gable Overhang Roof Panel 90° Square Comers 12x49 1/2x3/8" 17 -A: Position Gable Overhang Roof Panel 17-A Away from Supports 2" Nails - 8" Apart over the Left Gable Overhang Support 7 / (Part MP) as shown. Roof Panel should 7 7 be flush on the front and angled faces of .7 7 the support. ;:::::r: ure for Right Gable t 1 1 i Gab Overhang Support Overhang Roof Support (Part MO). t ;; 2x3x49 1/2" (MO) Position overhang above the door on the / RIGHT Front Wall with trim butting tightly against the Upper Roof Panel. (MP) • Secure with 2" nails spaced 8" apart. LEFT Nail at Angle the nails slightly toward the rear of the building. Slight Angle Repeat procedure for other Gable Toward Roof Overhang Roof Support. Secure the corners with two 2" nails each. Toe -nail the peak together with 2• Nails - 8" Apart two 2" nails. r ! J j /I TO COMPLETE YOUR BUILDING, REFER „. j I TO PAINTING, SHINGLING, AND GENERAL - ' ' MAINTENANCE AT THE BACK OF THIS MANUAL. \ . / 24 ' PAINTING, SHINGLING, AND GENERAL MAINTENANCE Your Handy Home Products Wooden Storage Building, like your home, requires a certain amount of normal maintenance and care: NAIL INSPECTION: After assembly is finished, CHECK ENTIRE STRUCTURE INSIDE AND OUT FOR ANY PROTRUDING NAIL POINTS. Pound the points over into the wood or cut off flush. CAULKING: Before painting, you must apply a quality exterior caulk at all horizontal and vertical seams, between trim and walls, gable seam, and around all door trim. Caulk is not included. PAINTING: Your Handy Home Products Wooden Storage Building must be painted with two coats of latex paint within 30 days of assembly in order to insure long life. ALL EXPOSED EDGES of the exterior siding panels and inside of doors must be sealed. The bottom edges are most important. Periodic refinishing, as weather conditions demand, is also necessary. Paint is not included. Exterior Paint or Stain Exterior Paint or Stain Building Size Trim Sides 8' x 8' 1 quart 1 gallon • 8' x 12' 1 quart 1 -1/2 gallons 8' x 16' 1 quart 2 gallons SHINGLING: Your Handy Home Products Wooden Storage Building must be shingled. We recommend that a drip edge also be applied before shingling. When shingling, follow manufacturer's installation instructions. Shingles and drip edge are not included. You will need: Building Size Shingles (Required) Drip Edge (Recommended) 8' x 8' 1 -1/3 sq. - 4 bundles 40 lin. ft. 8' x 12' 2 sq. - 6 bundles 50 lin. ft. 8' x 16' 2 -2/3 sq. - 8 bundles 60 lin. ft. Comments? Questions? Please feel free to call our Consumer Help Line Toll Free 1- 800 - 221 -1849, ext. 208 Monday through Friday 9:00 a.m. to 4:00 p.m. Eastern Standard Time Saturdays & Sundays, March through October 10:00 a.m. to 4:00 p.m. 35 FOUNDATION PLAN FOR 8 X 8 SHED I plan on first laying a 4" base of gravel. I will then lay 24" x 24" square cement blocks for my flooring. The building will sit on top of the blocks. Each of the four corners will be anchored by 2' steel anchor rods. Gary J. Krug