Loading...
HomeMy WebLinkAboutLetter (final inspection) - 02/02/1994 (1.10; City of Oshkosh �.�KQ�H P.O. BOX 1130 OSHKOSH, WI 54902 -1130 ON THE WATER February 2, 1994 G.M Builders 2178 West County Road Y Oshkosh, WI 54901 Attn: George Mathwig Dear George: Per your request a final building inspection was made at 1085 Laager Lane on February 1, 1994. The following items were found to be in noncompliance: ter ILHR 22.07, caulk around the natural gas entrance pipe into the dwelling. (/Per ILHR 21.04, maximum step to grade at all exterior doors shall not exceed 8 inches. Rear patio door can be pinned, or a temporary step installed. a r ILHR 21.25(2), install a wall stud directly under the break in.the top plate on the garage west wall. V e r ILHR 21.32, the fireplace hearth extension must comply with the manufacturers listing. (16 inches out in front, and at least 8 'riches extended to the sides) Per ILHR 21.22, secure the posts to the I- beams. All above items must be corrected, and final inspection called for within 30 days of this notice in order to secure the certificate of occupancy. Please call 236 -5051 if you have any further questions in this matter. Sincerely, /72 a/ - c9// Kenneth S. Staehler ' Building Inspector g