Loading...
HomeMy WebLinkAbout0143643-Electric Electric Permit Work Card Job Address 1020 -1142 S KOELLER ST Permit Number 143643 Create Date 10/13/2010 Owner KOELLER ONE LLC Contractor STIEGLER COMPANY INC Service ( ) New Change 0 Temp • N/A Type -) Overhead 0 Underground • N/A Volts 480 / 277 Circuits 30 Luminaires 175 Amps 1000 Switches 12 Receptacles 100 Value $47,000.00 Use /Nature COMM/ 1118 S Koeller St/ Hobby Lobby/ Interior Remodel to include moving the existing wall between the sales area and of Work back rooms, new lounge, restrooms, classroom and frameroom. * *check #48351 Inspections: Date/Time Inspected 11/02/2010 12:OOAM Type Reinspect Inspector Kevin Benner Fax request /Reinspect above ceiling. LV wiring to be completed. Existing wiring to the frame shop will be removed when the new frame shop is availabe, speaker to be lowered to the new ceiling, FA wiring to be completed. Date/Time requested: 11/01/2010 11:07 AM Notice Type: Ready Date/Time: 11/02/2010 12:OOAM Access: Requested by: STIEGLER COMPANY INC - Ron Klossner Phone Number: 920 - 494 - 0224 ' ` Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Date/Time Inspected 11/03/2010 12:OOAM Type Final Inspector Kevin Benner approved w /cond. Fax request/ Electrical requirements are correct Emergency Illumination to be added. (less that .10fc at the floor in the hot spot) Date/Time requested: 11/01/2010 11:07 AM Notice Type: Ready Date/Time: 11/03/2010 08:OOAM Access: Requested by: STIEGLER COMPANY INC - Ron Klossner Phone Number: 920 -494 -0224 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 1020 -1142 S KOELLER ST Permit Number 143643 Create Date 10/13/2010 Owner KOELLER ONE LLC Contractor STIEGLER COMPANY INC Service 0 New ) Change 0 Temp • N/A Type ` ; Overhead u Underground • N/A Volts 480 / 277 Circuits 30 Luminaires 175 Amps 1000 Switches 12 Receptacles 100 Value $47,000.00 Use /Nature COMM/ 1118 S Koeller St/ Hobby Lobby/ Interior Remodel to include moving the existing wall between the sales area and of Work back rooms, new lounge, restrooms, classroom and frameroom. * *check #48351 Inspections: Date/Time Inspected 10/20/2010 12:OOAM Type Consultation Inspector Kevin Benner Discussed the emergency illumination with the Building Inspector, G.0 & Kyle from the E.C. Date/Time requested: 10/20/2010 00:00 AM Notice Type: Ready Date/Time: 10 /20/2010 12:OOAM Access: Requested by STIEGLER COMPANY INC Phone Number O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date/Time Inspected 10/28/2010 12:OOPM Type Abv Ceiling Inspector Kevin Benner not approved Fax request Date/Time requested: 10/27/2010 01:33 PM Notice Type: FC Ready Date/Time: 10/28/2010 12:00PM Access: Enter thru back of building • Requested by: STIEGLER COMPANY INC - Ron Phone Number: 920- 494 -0224 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date/Time Inspected 11/01/2010 12:OOPM Type Consultation Inspector Kevin Benner not approved IFieid Request from Kyle / Emergency Illumination test Not ready Date/Time requested: 10/28/2010 00:00 PM Notice Type: Ready Date/Time: 11/01/2010 07:28AM Access: Requested by: STIEGLER COMPANY INC Phone Number: O Reinspect Fee ` Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 1020 -1142 S KOELLER ST Permit Number 143643 Create Date 10/13/2010 Owner KOELLER ONE LLC Contractor STIEGLER COMPANY INC Service 0 New 0 Change Temp • N/A Type 00 Overhead 0 Underground • N/A Volts 480 / 277 Circuits 30 Luminaires 175 Value $47,000.00 Amps 1000 Switches 12 Receptacles 100 Use /Nature COMM/ 1118 S Koeller St/ Hobby Lobby/ Interior Remodel to include moving the existing wall between the sales area and of Work back rooms, new lounge, restrooms, classroom and frameroom. * *check #48351 approved w /cond. Inspections: Date/Time Inspected 10/15/2010 12:OOAM Type Rough In Inspector Kevin Benner approved Fax request South three offices only on the east side of the building Date/Time requested: 10/13/2010 11:53 AM Notice Type: Ready Date/Time: 10/15/2010 08:OOAM Access: '.Enter thru back of building Requested by: The Stiegier Co - Ron Klossner Phone Number: 920 - 494 -0224 • O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date/Time Inspected 10/19/2010 02:30PM Type Rough In Inspector Kevin Benner approved Fax request / Rough for rest of remodel minus the janitor closet area Reviewed with Kyle from the E.C. while on site Date/Time requested: 10/18/2010 09:12 AM Notice Type: Ready Date/Time: 10/18/2010 09 :36AM Access: iBack of building Requested by: STIEGLER COMPANY INC - Ron Klossner Phone Number: 920 - 494 -0224 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date/Time Inspected Type Rough In Inspector Kevin Benner approved Field Request from Kyle Janitor closet area Date/Time requested: 10/19/2010 08:22 AM Notice Type: Ready Date/Time: 10/20/2010 08:22AM Access: Requested by: STIEGLER COMPANY INC Phone Number: 920 -494 -0224 Ron Klossner O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid • • �e erELECTRICAL CONTRACTORS AND COMMUNICATIONS SERVICES February 15, 2011 RECEI D FEB 1 8 2011 DEPARTMENT OF City of Oshkosh COMMUNITY DEVELOPMENT INSPECTION SERVICES DIVISION Inspection Services Division PO Box 1130 Oshkosh, WI 54903 Attn: Kevin Brenner / Electrical Inspector RE: Hobby Lobby / Koeller One LLC 1118 S. Koeller St. Building Permit #143152 Electrical Permit #143643 Dear Kevin, Stiegler Electric has inspected the installation of emergency ballasts in existing fluorescent fixtures, providing an illuminated path of egress, and found the installation completed by others acceptable. The wire methods, grounding, fixture disconnects, ballast installation, and extension of the night light circuit were examined and found NEC compliant. Stiegler Electric considers this project completed and the electrical permit closed out. i (4._(.4...„,, Sincer- , Mr. Ron Klossner, President pjj The Stiegler Company, Inc. • PO. Box 3644 • Green Bay, WI 54303 • 920/494 -0224 • Fax: 920/494 -4473