HomeMy WebLinkAbout0089043-Building CITY OF OSHKOSH No 0089043
OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 2388 SHORE PRESERVE DR Owner OSHKOSH AREA SCHOOL DISTRICT Create Date 09/05/2001
Designer Contractor UNLICENSED - UNKOWN
Category 110 - New Single Family Plan c O v/
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze
Zoning R -1 Class of Const: 8 Size
Unfinished /Basement 2200 Sq. Ft. Rooms Height 18 Ft. ❑ Projection
Finished /Living 2200 Sq. Ft. Bedrooms Stories 1 Canopies
Garage 800 Sq. Ft. Baths Signs
Foundation 0 Poured Concrete 0 Floating Slab 0 Pier 0 Other
0 Concrete Block • Post 0 Treated Wood
Occupancy Permit Not Required Flood Plain No Height Permit Not Required
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ New Single Family Dwelling w/ attached garage, driveway, and deck as per plans.
of Work
HVAC Contractor CENTRAL HEATING SERVICE INC Plumbing Contractor SAMMONS PLUMBING
Electric Contractor VAN ERT ELECTRIC
Fees: Valuation $1 0 . 0 Plan Approval $75.00 Permit Fee Paid $530.00 Park Dedication $100.00
Issued By: Date 09/11/2001 Final /O.P.
0 Permit Voided
In the performance of thi ork 1 gree to perfor all work pursuant to rules governing the described construction.
Si g n ature -- T � -Z'- Date e 1/4/ 20 7
Agent/Owner �
Address 0 - 0000 Telephone Number 292--1225
OSHKOSH GRADE STAKE FORM
ON THE WATER Grade Stake Number 6596
Name OSHKOSH AREA SCHOOL DISTRICT Address 2388 SHORE PRESERVE DR Create Date 09/05/2001
Lot 9 Block Ward
Subdivision Northshore Estates Zone
Street Number Lot Dimensions 100 x 120' I I Sidewalk Existing
Building Grade Elevation Stakes Set At Site 00 /00 /0000 Set By
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation
has commenced.
• ) •
Wisconsin Department of Industry, WISCONSIN UNIFORM Application No.
Labor and Human Relations
Safety and Buildings Division BUILDING PERMIT 0089043
P.O. Box 2509 APPLICATION Parcel No.
Madison, WI 53701 -2509
Wisconsin Statues 101.63, 101.73
«; ' Q Constr ❑ HVAC ❑ Elec ❑ Plbg Q Erosion ❑Other:
Owner's Name Mailing Address Telephone No.
OSHKOSH AREA SCHOOL DISTRI. PO BOX 3048 Oshkosh WI 54901 - 0000 292 -4275
Contractor: U Con Li Elec ❑ HVAC ❑ Plbg Lic/Cert # Mailing Address Telephone No.
UNLICENSED - UNKOWN 0 - 0000
Contractor: ❑ Con U Elec ❑ HVAC Li Plbg Lic/Cert # Mailing Address Telephone No.
VAN ERT ELECTRIC 170921 2000 PROGRESS WAY KAUKUANA WI 54130 - 0000 (920) 766 -3888
Contractor: ❑ Con ❑ Elec U HVAC Li Plbg Lic/Cert # Mailing Address Telephone No.
CENTRAL HEATING SERVICE INC 4272 1565 HARRISON STREET OSHKSOH WI 54901 - 0000 (920) 235 -6670
Contractor: ❑ Con ❑ Elec ❑ HVAC U Plbg Lic/Cert # Mailing Address Telephone No.
SAMMONS PLUMBING 522 W. MURDOCK AVE OSHKOSH WI 54901 - 0000 414 - 231 -9880
' • :° Lot Area
° _��< .+ Sq. ft. 1/4, 1 /4,Section ,T N,R E(or)W
Building Address Subdivision Name Lot No. Block No.
2388 SHORE PRESERVE DR Northshore Estates 9
Zoning District(s) Zoning Permit No. Front Rear Left Right
CI ' , r ,. ' $' s i� .x.: * . OC +r E c g * i i i o s "'�P�,57I;: g a 1 a ms: x.,),) s m .>
� - d i ° .° ° o...: *o° « '. �M1.r���� �ro� . " M4Ar am. ? <'o. °. � o o a. � m � P . .a.� � a �
Q New ❑ Repair i0 Single Family Entra Panel i0 Forced Air Furnace • • -
❑ Alteration ii Raze ❑ Two Family Size: 200 am • ❑ Radiant Baseboard or Panel Fuel Ga ❑ Garage S e r v i ce: ❑ Heat Pump • - - ✓ I1 El l
❑ Addition ❑ Move ■ ■ ■ ■
❑ Other (print): 111 Overhead ❑ Boiler ✓
❑Other i 4 Underground Q Central Air Conditionin Dwelling unit will have 3 kilowatt or
lc i - "C'YP .. • ° a » Other
« a Q Site Constructed Q Concrete � � at :Mk option E sealing
Manufactured Masona Sewer ...
Unfinished ❑ ❑ ry
Basement 2200 Sq. ft. - - « *�P ❑ Treated Wood Q Municipal
Living Area 2200 S ft. El 1-Story
« �• ❑ Other El Perm Permit No. Envelo f e + . ®` 3wp 3 # ** k*
❑ 2-Story *' « p 38479 BTU /HR
Garage 800 Sq. ft. Other . Seasonal : �� &
Q Permanent : , �*« ;_ � & Infiltration 27441 BTU /HR
Li Other Q Municipal Utility I.. .T.f111 «
1121 Plus Basement ❑ Private On -Site Well $200,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express ' d, on t epart nt or municipality; and certifies that all the above inform lion i s accurate.
APPLICANT'S SIGNATURE Z DATE SIGNED 4 ih1 d /
This p it is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS p
revocation of this permit or other penalty
See Plan Review
1 «� G a « ❑ Town ❑ Village Q City ❑ County ❑ State of: Municipality Number of Dwelling Location:
° °« City Of Oshkosh 7 0 - 2 6 6
� � � , � « mt «� *gy « �� « . « « « «� «« «..
o �r « « '. r m x +�''';;;ic« a * : ''o . � ^." s a » �,� wa m «» e « a a `"a a _ff !:-.17,;:, , , xi. : , a s .. e ::4;;:':' « r
.ek .+.« srs:41' ..I.Xa:+h «. .ez,.n.#ak !9.> <*< ,tea mm __!: '.. ... .Im.,9:mi �. :.m:1 a «.f�«"' .r momm � «m s _t:.�ms.� �. _.s . «m «"ism «I «m «wm «�QO. m m« �« m. +i�4
Plan Review $75.00 Q Construction Name Brian Noe
Inspection II HVAC
Wis. Permit Seal $30.00 Electrical Date 09/05/2001
•
Other Plumbing
Q Erosion
Total $105.00 il 256596 Cert. No. 70266
SBD -5823 (R. 07/92)
OSHKOSH PARKLAND DEDICATION FEE COLLECTION RECORD
ON THE WATER
Job Address 2388 SHORE PRESERVE DR Date 9/11/01
Name OSHKOSH AREA SCHOOL DISTRICT
Address PO BOX 3048 Oshkosh WI 54901
Subdivision Northshore Estates Lot 9
Building Permit Number 0089043
Number of Dwelling Units 1 Number of Structures 1
Fee Required $100.00 Fee Paid
Owner's Signature 41 Date 7 11 __
Inspector's Signature � / Date �� o�
ZONING/LAND USE COMPUANCE CHECKLIST
JOB LOCATION: 2.- ? , 11D)-7 - )35 E, 6 u t ,/Z ZONING
PROPERTY OWNER/CONTRACTOR: G 4.,,&-e5,y , ,_,yam_ .IDls7-
CONSTRUCTION DATA: �ew Construction _ Addition Alteration
TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) iie
COMPLIANCE CHECKLIST
DEFICIENT COMMENTS
Use
___ Lot Width
Lot Area
Lot Area Per Family
Floodplain
Front Yard
Front Yard Side Street
Rear Yard
Side Yards
Building Area
Parking Standards
Off -Street Loading Standards
Vision Clearance _
Transitional Yard Standards
Landscape Standards
Height
Conditions of Approval
Compliance with P.C. or
BZA Conditions of Approval
Signage Standards
Drainage Plan
REVIEW AUTHORITY
As per Section 30 -5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or
designee, must approval all plans, except the following: (1) Alterations or interior work when the use is
conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc.,
when the use is conforming and when no change is proposed.
APPROVED DENIED
Plan Commission Action Required
Variance(s) Required
REVIEWED BY: % DATE: (
q
--o1
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903 -1130
OOJH Office 920 - 236 -5050
ON T+iE WATER Fax 920 - 236 -5084
PLAN REVIEW
Project Address: 2388 pore Preserve Dr Date Reviewed: 9/10/01
Submitted By: Oshkosh AreaSchool District Phone Number: 292 -4275
Plan Number: C9-091 -0801 0 Mailed
Reviewed By: Brian Noe ❑ Faxed 233 -5398
Phone: 236 -5051 Delivered with Permit
Result of Plan Review:
►/ Conditionally Approved
Withheld Pending Approval of Additional Information
Not - Approved, Plans Returned for Revisions
Conditions Noted on Plan Review
1. 21.02 Complete truss plans and layout are required to be submitted for review, and be
provided on site at the time of rough inspection.
2. 21.09 Smoke detectors are required to be provided in each bedroom and adjacent to all
sleeping areas. Because there are two distinct bedroom areas two smoke detectors will be
required in the common area on the first floor, one adjacent to each bedroom group.
3. Min hallway width is 36 inches finished surface to finished surface.
4. No structure is permitted within anyEasement located on the property.
5. The drainage will be required to be completed in compliance with the approved drainage
plan.
6. See also standard conditions of plan approval.
S' ofA l ca u j ' Pam �
you pp
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address Permit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire - resistive rating of 20
minutes. All drywall joints are required to be taped /sealed unless the joints are fitted so
that the gap is no more than a dimes thickness ( 1 /20 -inch) and backed by solid wood or
drywall with the joints staggered.
3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
6. All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
8. Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is
required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion
control measures must be maintained until the lawn is established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re- inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re- inspection fee per inspection.
15. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
Silnalure olAppficanl i 4� bC aLJale: C V I/147
igIAJA(��AE7
4 N '. swr Ff uc
bi a
17
R.
y / $essr, U
L,
1 • ,,
25 25 8ti
55' 1
I
II
12&
u) i c
i i Z ti- li
{
k ...0 1
I cy
. ,,-,,
‘a
I. , N
i
1 E