Loading...
HomeMy WebLinkAbout16760-Plumbing (09/21/2010) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 9/21/2010 Compliance Date 10/21/2010 Compliance No Address 721 E PARKWAY AVE Name Address City State Zip Code Sent to Owner ROBERT /JEAN MCGREGOR TRUST 1009 LAUREL RD SANTA PAULA CA 93060 -1231 Li Required for Occupancy Occupancy Introduction Inspection /consultation requested by the contractor and performed on 9/10/10 revealed the following violations: Item # 1 Code MC Sect 24 - 6.1 Compliance No Compliance Date 10/21/2010 Description No person(s) shall discharge or cause to be discharged, any polluted waters such as stormwater, groundwater, roof runoff, 09/21/2010 subsurface drainage or cooling water to any sanitary sewer. Foundation drain tile discharging to the sanitary floor drain is not permitted. The foundation drain tile shall discharge to a sump with pump and discharge to grade where no nuisance is created Last or to the storm sewer. Updated Item # 2 Code Comm. 82 -84 Compliance No Compliance Date 10/21/2010 Description Basement bathroom and laundry discharge shall comply with all code requirements of the current Wisconsin Uniform Plumbing 09/21/2010 Code. This includes but is not limited to compliant drains, sanitary vents and points of discharge. Last Updated Item # 3 Code Wis Stats 145.06 Compliance No Compliance Date 10/21/2010 Description No person may engage in or work at plumbing in the state unless licensed to do so by the department. This shall not apply to 09/21/2010 plumbing work done by a property owner in a one - family building owned and occupied by him or her. Last Updated Item # 4 Code MC Sect 20 -8 Compliance No Compliance Date 10/21/2010 Description No person shall perform or permit the performance of any plumbing work, as defined by state statute or regulation adopted by 09/21/2010 reference as a part of this Code, unless a permit is first obtained. A licensed plumber is required to secure a permit prior to work commencing. Last Updated Item # 5 Code Comm 82.41 Compliance No Compliance Date 10/21/2010 Description Water supply systems and the connection of each plumbing fixture, piece of equipment, appliance or nonpotable water supply 09/21/2010 piping system shall be designed, installed and maintained in such a manner to prevent the contamination of water supplies by means of cross connections. A licensed plumber is required to install cross connection protection at the boiler water supply. Last Updated 16760 Page 1 of 2 C.) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 9/21/2010 Compliance Date 10/21/2010 Compliance No Address 721 E PARKWAY AVE Name Address City State Zip Code Sent to J Owner ROBERT /JEAN MCGREGOR TRUST 1009 LAUREL RD SANTA PAULA CA 93060 -1231 L Required for Occupancy Occupancy Introduction Inspection /consultation requested by the contractor and performed on 9/10/10 revealed the following violations: Item # 6 Code Comm 20 - 25 Compliance No Compliance Date 10/21/2010 Description The flue piping serving the gas fired water heater is required to be properly fastened per the Wisconsin Uniform Dwelling Code 09/21/2010 and manufacturer's recommendations. Last Updated Summary It was stated to the plumbing inspector by the general contractor that the residence was flooded out. If this is accurate and the gas fired appliances in the residence were submerged, an inspection by a licensed contractor would be required in order to protect the health and welfare of future building occupants. Compliance is required prior to occupancy. Building, electrical and HVAC permits are also required prior to work commencing. Any questions please contact the plumbing inspector at 920 - 236 -5052. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 10/21/2010 Office hours for obtaining pe its are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call t nspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what nerds be inspected. Signature �/ Date Inspected by: Paul Wolf 236 -5052 pwolf @ci.oshkosh.wi.us hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: J Bldg MARC'S REMODELING 1805 MARQUETTE AVE OSHKOSH WI 54901 -0 LJ Elec - u HVAC - J Plbg C SWEETING PLUMBING LLC 1583 COUNTRY MEADOW CT OSHKOSH WI 54904 -9316 Designer LJ Other - Lf Inspector 16760 Page 2 of 2