HomeMy WebLinkAbout2001-State of WI (trans id #632178) RECEIVED Safety and Buildings
4 01 PILOT CT STE C
WAUKESHA WI 53188 -2439
r s TDD #: (608) 264 -8777
4sconsin A R 1 �� { www.commercestate.wi.us /sb
www.wisconsin.gov
Department of Commerce DEPARTMENT or
COMMUNITY DEVELOPMENT daJ. Blanchard, Brenda J. Blanchard, Secretary
April 12, 2001
CUST ID No.264198 ATTN.• Buildings & Structures Inspector
OSHKOSH INSPECTION
ROBERT E WILLIAMS 215 CHURCH AVE
1285 SUNNYRIDGE RD PO BOX 1130
PEWAUKEE WI 53072 OSHKOSH WI 54902 -1130
RE: CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 04/12/2003 Identification Numbers
Transaction ID No. 632178
Site ID No.
SITE Please refer to both identification numbers,
SITE ID: 627855, ROBIN LANE APARTMENTS above, in all correspondence with the agency.
WINNEBAGO COUNTY, CITY OF OSHKOSH; ROBIN LANE, OSHKOSH 54901
FACILITY: ROBIN LANE APARTMENTS, BLDG 2 ROBIN LANE, OSHKOSH 54901
ROBIN LANE APARTMENTS BLDG 3 ROBIN LANE, OSHKOSH 54901
FOR:
DESCRIPTION: APARTMENT BUILDING 1
OBJECT TYPE: BUILDING REGULATED OBJECT ID NO.: 786267
8 WOOD FRAME - UNPROTECTED CLASS OF CONSTRUCTION, NEW PLAN, 8,470 PROJECT SQ FT,
UNSPRINKLERED, OCCUPANCY (RESIDENTIAL)
DESCRIPTION: APARTMENT BUILDING2
OBJECT TYPE: BUILDING REGULATED OBJECT ID NO.: 786268
8 WOOD FRAME - UNPROTECTED CLASS OF CONSTRUCTION, NEW PLAN, 8,470 PROJECT SQ FT,
UNSPRINKLERED, OCCUPANCY (RESIDENTIAL)
DESCRIPTION: APARTMENT BUILDING 3
OBJECT TYPE: BUILDING REGULATED OBJECT ID NO.: 786269
8 WOOD FRAME - UNPROTECTED CLASS OF CONSTRUCTION, NEW PLAN, 8,470 PROJECT SQ FT,
UNSPRINKLERED, OCCUPANCY (RESIDENTIAL)
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in
chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements.
The following conditions shall be met during construction or installation and prior to occupancy or use:
• COMM 50.12 This review does not include heating, ventilating or air conditioning. The owner should be
reminded that HVAC plans, calculations, a completed SBD -118 application form and appropriate fees are
required to be submitted for review and approval prior to installation.
• COMM 50.12 This review does not include lighting. COMM 63.01 Prior to installation, lighting plans
and calculations shall be prepared in compliance with the code and properly signed and sealed. The plans
shall be available at the job site as requested by the Department representative or local official.
• COMM 50.12 Prior to installation, one copy of the wood truss plans, calculations, a completed SBD -118
application form and a $100 submittal fee shall be submitted to this office. Also one copy of the plan shall
be provided at the job site. When the total building volume exceeds 50,000 cubic feet, each set of plans
shall bear an indication of review which has been signed or initialed by the building designer of record.
ROBERT E WILLIAMS Page 2 4/12/01
• This approval is only valid for the apartment buildings number 1, 2, and 3 and is not valid for any other
building or structure on the site.
• COMM 57.871 It is the designer's responsibility to verify that adequate maneuvering space is provided
within the higher usability bathrooms on the first floor level in order to use the bathroom facilities.
A copy of the approved plans, specifications and this letter shall be on -site during construction and open to
inspection by authorized representatives of the Department, which may include local inspectors. All permits
required by the state or the local municipality shall be obtained prior to commencement of
construction /installation/operation.
In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions
should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead.
Sincerely, DATE RECEIVED 04/10/2001
A e < ,t_t_t„e_<_ i FEE REQUIRED $ 1,270.00
FEE RECEIVED $ 1,270.00
LAWRENCE STILEN BALANCE DUE $ 0.00
P.E., BUILDING CONSULTANT , INTEGRATED SERVICES
(262) 548 -8607, FAX: (262) 548 -8614 , MON -THURS 6:30 - 4:00, FRI
6:30 - 10:30 iS-. T'Oode: 7
LSTILEN @COMMERCE. STATE. WI.US
cc: PETER R OCHS , BUILDING INSPECTOR, (920) 929 -3167, FRIDAY, 7:45 A.M. - 4:30 P.M.
ZANGL & SHIELDS LLC