Loading...
HomeMy WebLinkAbout2003-State of WI (trans id #939168) Safety and Buildings 141 NW BARSTOW ST FL 4TH WAUKESHA WI 53188 -3789 TDD #: (608) 264 -8777 NY4sconsin www.commerce.state.wi.usisb www.wisconsin.gov Department of Commerce Jim Doyle, Governor Cory L. Nettles, Secretary November 05, 2003 CUST ID No.681637 ATTN: Buildings & Structures Inspector JOEL CLARY BUILDING INSPECTION SUMMIT DESIGN LLC CITY OF OSHKOSH W6744 ROGERSVILLE RD POB 1130 FOND DU LAC WI 54937 OSHKOSH WI 54902 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 11/05/2004 Identification Numbers Transaction ID No. 939168 SITE• Site ID No. 627855 Robin Lane Apartments Please refer to both identification numbers, Robin Lane above, in all eorrespoudence with the agency. City of Oshkosh, 54901 Winnebago County Facility: Building 1 Robin Lane, Oshkosh 54901 Building 2 Robin Lane, Oshkosh 54901 Building 3 Robin Lane, Oshkosh 54901 FOR: Object Type: HVAC System Regulated Object ID No.: 929485 Hot water /Steam system Object Type: HVAC System Regulated Object ID No.: 929486 Hot water /Steam system Object Type: HVAC System Regulated Object ID No.: 929487 Hot water /Steam system The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Key Item(s) • COMM 64.22(1) Boilers and pressure vessels must be constructed and installed in compliance with the standards of the American Society of Mechanical Engineers, as adopted under chs. COMM 41 & 42. Submit • COMM 64.22 (1) This review does not include approval or registration for the installation of Boilers and Pressure Vessels as prescribed by COMM 41.41. The installation of any Boiler or Pressure Vessel shall be registered with the Department by the installer before the system is placed in operation. Registration shall be in writing on Form SBD -6314. This form, and additional information, may be obtained via telephone at 608 -266- 1818 or via the Internet at http: / /www. commerce state.wi.us /SB /SB- DivForms.html #Boilers JOEL CLARY Page 2 11/5/03 Reminders • COMM 63.29(2) Provide piping carrying fluids less than 55oF or more than 80oF with insulation to the thickness, and insulative value shown in COMM Table 63.29 -1, except where it can be shown that the heat gain to or heat loss from the piping without insulation will not increase building energy use. • COMM 64.23(4) No pipe carrying hot water, steam or other fluid at a surface temperature exceeding 250oF may be placed within one inch of any woodwork, pass through a combustible floor, ceiling or partition, unless the pipe is protected by a metal tube one inch larger in diameter than the pipe or with approved pipe covering. • COMM 64.53(1) HVAC system balancing report shall be made available to the department upon request. • COMM 64.53(3) Operating manuals concerning the HVAC equipment shall be presented to the owner. • ADAAG 4.2.5 Forward reach thermostat controls shall be located 48" above the finished floor. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at (262)548 -8603, or at the address on this letterhead. Sincerely, Fee Required $ 580.00 Fee Received $ 580.00 Balance Due $ 0.00 David Wallace Eng. Cons. Building Systems , Integrated Services WiSMART code: 7648 (262)548 -8603 , 7:45 -4:30 dwallace@commerce.state.wi.us cc: Peter R Ochs, Building Inspector, (920) 948 -3500, Friday, 7:45 A.M. - 4:30 P.M. Pam Zangl, Zangl & Shields LLC Jon P Wolf, Boiler Inspector, (920) 723 -0032