HomeMy WebLinkAboutPlumbing - 07/09/2001 CD
INSPECTION SERVICES DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
OSHKOSH CITY OF OSHKOSH, WISCONSIN
ON THE WATER CORRECTION NOTICE
Issue Date 7/9/01 Compliance Date 8/8/01 Compliance No
Address 416 ROCK PL Inspected By PLUMBING INSPECTOR
Name Address City State Zip Code
Sent to L� Owner GAY L MANDEIK 416 ROCK PL OSHKOSH WI 54901 -3980
lA Contractor TUREKS PLUMBING INC N2808 MEADE ST APPLETON WI 54913 -
U Other -
u Inspector
lA Required for Occupancy Occupancy Notice 0 First 0 Final Q Other
Introduction An inspection of the plumbing on 7/3/01 revealed the following violation(s):
Item # 1 Code Comm 82.40(5)(d)5 Compliance No Compliance Date 8/8/01 IMMEDIATELY
Description Every WATER HEATER relief valve which is designed to discharge water or steam shall be connected to a
discharge pipe.
Item # 2 Code Comm 82.40(5)(d)5.e Compliance No Compliance Date 8/8/01 IMMEDIATELY
Description The discharge pipe shall be installed to drain by gravity flow to a floor served by a floor drain or to a receptor in
accordance with s. Comm 82.33 (8). The outlet of the discharge pipe shall terminate within 6 inches over the floor
or receptor, but not less than a distance equal to twice the diameter of the outlet pipe. The outlet of the discharge
pipe may not be threaded.
Item # 3 Code Comm 82.40(7) Compliance No Compliance Date 8/8/01 IMMEDIATELY
Description SIZING OF WATER SUPPLY PIPING. The sizing of the water supply system shall be based on the empirical
method and limitations outlined in this subsection or on a detailed engineering analysis acceptable to the
department. WATER CALCULATION WORK SHEET REQUIRED. PRESSURE BALANCE FAUCET.
Page 1 of 2
INSPECTION SERVICES DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
OSHKOSH CITY OF OSHKOSH, WISCONSIN
ON THE WATER CORRECTION NOTICE
Issue Date 7/9/01 Compliance Date 8/8/01 Compliance No
Address 416 ROCK PL Inspected By PLUMBING INSPECTOR
Name Address City State Zip Code
Sent to IA Owner GAY L MANDEIK 416 ROCK PL OSHKOSH WI 54901 -3980
IA Contractor TUREKS PLUMBING INC N2808 MEADE ST APPLETON WI 54913 -
U Other
L J Inspector
IA Required for Occupancy I Occupancy Notice 0 First O Final O Other
Introduction An inspection of the plumbing on 7/3/01 revealed the following violation(s):
Item # 4 Code Comm 82.40(7)(f)1 Compliance No Compliance Date 8/8/01 IMMEDIATELY
Description Water distribution piping 1/2 inch in diameter serving 2 or more plumbing fixtures may not have a load of more than
2 water supply fixture units. @@
Summary You will be required to call for re- inspection no later than 8/8/01.
DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL (920) 236 -5050 FOR INSPECTION.
Signature Date
Page 2 of 2