HomeMy WebLinkAbout2010-Electric SQUARE D Schneider Electric Services APPLETON FACILITY N1051B Tower View Dr. Greenville, WI 54942 920 -757 -1057 Fax: 920 - 757 -1056 October 21, 2010 Mr. Mike Kortz Progressive Electrical Services 571 Marcella Street Kimberly, WI 54136 -1760 Re: FVTC Oshkosh Dear Mike, Enclosed is the report for the Square D low voltage circuit breaker that was tested at the new Fox Valley Technical College building located in Oshkosh, WI. The following is a summary of the field tests performed and findings. Low Voltage Circuit Breaker: Secondary Injection Test: This test ensures proper calibration of all functions of the solid statetrip unit. All results were acceptable. Ground Fault System Test: This test is used to verify the proper operation of the ground fault system. It was performed using the primary current injection method on the service disconnect circuit breaker. All results were acceptable. All of the equipment tested passed both the visual/mechanical inspections and the electrical tests performed. The equipment was found to be operational and within applicable standards and manufacturer's tolerances. Thank you for allowing Square D Services to meet the electrical needs of the Fox Valley Technical College and Progressive Electrical Services. If you have any questions or concerns regarding the enclosed test reports or work performed please feel free to contact me anytime at 920 -585 -0362. Regards, f . r Terry Michels Square D Sr. Field Service Representative Email: Terry. Michels @US.Schneider - Electric.com Fill SQUARE I:3 Services Division =-i Schgeider Eiecc.-c_ LV Circuit Breaker 1-888-778-2733 (Manually Operated) REFERENCE INFORMATION Contact Name: TOM OLSON 920-540- FSR: Terry Michels Job No: 29174940-001 4055 Customer Site: FOX VALLEY TECH Customer Ref No: DBID: 21-270420 FOR PROGRESSIVE Date: October 21, 2010 4200 POBEREZNY ROAD OSHKOSH, WI 54902 IDENTIFICATION - , Sub Station Location: Main Customer Asset ID: Service Disconnect Sub ID: Main Circuit ID: Main NAMEPLATE DATA Manufacture: Manufacture Date: Serial No: Type: ' , Z Square D 2010 N/A RKF3620044A Frame Size: Rated Amps: Sensor Rating: Rating Plug 2000 Amps 2000 Amps 2000 Amps 2000 Amps' i - Fuse Type: Fuse Manufacture: Fuse Model/Catalog No: Fuse Rating;' Unfused N/A Trip Unit Type: Trip Curve No: Interrupt Rating: MountinU: Micrologic 6.0A 613-5 65 KA Fixed Number of Operations: Number of Operations: INSPECTION CHECKLIST ITEM AS LEFT ITEM AS LEFT Blown Fuse Indicator (BFI): Not Applicable Switch Condition: Acceptable -' Interlocks: Acceptable Primary Disconnects: Acceptable Over-Travel Stops: Not Applicable Secondary Disconnects: Acceptable Mechanical Wear: Acceptable Ground Contacts: Acceptable Mechanical Lubrication: Acceptable Main Contacts: Acceptable Intermediate Contacts: Not Applicable Arcing Contacts: Acceptable Trip Free Test: Acceptable Pri.Current Path Lubrication: Acceptable Manual Close Test: Acceptable Arc Chutes: Acceptable Spring Discharge: Not Applicable Interphase Barriers: Acceptable Insulated Linkages/Bracing: Acceptable Gap / Wipe Settings: Not Applicable Contact Alignment / Not Applicable Sequence: Test Report, 29174940 - 001 3. OVER CURRENT PROTECTION - TRIP UNIT DATA Test Equipment ID: FFTS -803 Calibration Date: 1/19/10 FSR: 803 Manufacture: Square D Trip Device Serial #: N/A Style: Micrologic 6.0A Battery Status As Found: Pass As Left: Pass Settings CT Coil Ratings: 2,000 CT Tap Ratings: 2,000 Rating Plug: 2,000 As As As Left I *2T As As As Left I *2T Found Tested Setting ON Found Tested Setting ON Setting Setting Setting Setting Long Time Pickup 1 1 1 Instantaneous Pickup 2 2 2 Long Time Delay .5 .5 .5 Ground Fault Pickup 500 500 500 Short Time Pickup 1.5 1.5 1.5 Ground Fault Delay .1 .1 .1 Yes Short Time Delay .1 .1 .1 Yes TRIP UNIT TIMING TEST (measured Ian Secor.>,ds) Trip Device Test Current Specified Range Phase A Phase B Phase C Function Amps Amp Range Minimum Maximum As Found As Left As Found As Left As Found As Left Long Time 2,667 12 20 14.38 14.38 r 14.38 Short Time 3,500 4 6 5.201 5.201 5.201 Instantaneous 5,000 0.01 0.065. 0:037 0.037 ' ..: 0.037 Ground Fault 1,000 0.1 .., 0.2 04137 0.137 0.137 . . .- NOTES . GF system tested utilizing primary injection method. Test results are as follows: No Trip Test: Passed Trip Test: Tripped at 503 amps , „ . Test Report, 29174940 - 001 4.