HomeMy WebLinkAbout0100375-BuildingOSHKOSH
ON THE WATER
Job Address
Designer
Category
Type
3321 LOUISE CT
110 - New Single Family
CITY OF OSHKOSH No 0100375
BUILDING PERMIT -APPLICATION AND RECORD
Create Date 03/07/2003
Owner HAROLD SALZER
Contractor SALZER SIDING
Building O Sign O Canopy O Fence O Raze
Plan E1-023-0303R
Zoning R-1 Class of Const: 8
Unfinished/Basement 1482 Sq. Ft. Rooms 4
Finished/Living 1482 Sq. Ft. Bedrooms 3
Garage 776 Sq. Ft. Baths 2
Foundation O Poured Concrete (~ Floating Slab (~) Pier
C) Concrete Block (~) Post C) Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units 1
Height 16 Ft.
Stories 1
Other
Size Irrg
[] Projection
Canopies
Signs
Height Permit Not Required
# Structures 1
Use/Nature NSFR/1 story home with a 2 car attached garage, 12'x12' rear concrete patio.
of Work
HVAC Contractor MCM AIR INC Plumbing Contractor WELLNITZ PLUMBING
Electric Contractor SECKAR ELECTRIC
Fees: Valuation $77,000.00 Plan Approval $75.00 Permit Fee Paid $311.00 Park Dedication $0.00
Issued By: / Date 03/25/2003 Final/O.P. 00/00/0000
[] Permit Voided
In the performance of this work I agree to perform all work pursuant t~p~les governing the described construction.
S,gnature ..~-'~.-.~¢.--~¢~j/2¢''~ /~ /--//~/' ',1 Date ~-~,~
'
Address PO BOX 825 OSHKOSH WI 54903 - 0825 Telephone Number (920) 231-5025
OSHKOSH GRADE STAKE FORM
ON THE WATER Grade Stake Number 6910
Name HAROLD SALZER Address 3321 LOUISE CT Create Date 03/07/2003
Lot 14 Block Ward
Subdivision Assessors plat #1 Zone
Street Number Lot Dimensions L=J_ Sidewalk Existing
Building Grade Elevation Stakes Set At Site 03/11/2003 Set By D.W.G. BK - 586, P - 64
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before exc~/-at~on
Wisconsin Department of Industry,
Labor'and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
WISCONSIN UNIFORM Application No.
BUILDING PERMIT ~_~_ 7 5
APPLICATION IPa~ce~ ~-°-
[] Constr [] HVAC [] Etec [] Plbg [] Erosion E~ Other:
Mailing Address Telephone No.
PO BOX 825 Oshkosh WI 54903 - 0000
Lic/Cert # Mailing Address Telephone No.
7351 PO BOX 825 OSHKOSH WI 54903 - 825 (920) 231-5025
Owner's Name
HAROLD SALZER
Contractor: [~j conE]] Elec]]]] HVAC bi PIbg
SALZER SIDING
Contractor: bi Con ~ Elec bi HVACL] Plbg
SECKAR ELECTRIC
Contractor: ~ I Con ~j Elec[~J HVAC [] Plbg
MGM AIR lNG
Contractor: L_] Con [] EIoo E]] HVAC[] Plbg
WELLNITZ PLUMBING
Lic/Cert #
689404
Mailing Address
5920 COURTNEY PLUMMER RD
WINNECONNf WI 54986 - 0
Telephone No.
(920) 582-4909
Lic/Cert # Mailing Address Telephone No.
4264 6122 COUNTY ROAD M WINNECONNiW154986 - 9780 (920) 582-4402
Lic/Cert Cf Mailing Address Telephone No.
223819 4810AMBERWOOD LN APPLETON WI 54915 -0 (O)231-7390
Sq. ft. 1/4, 1/4,Section ,T N,R E(or)W
Block No.
Building Address
3321 LOUISE CT
Subdivision Name Lot No.
Assessors plat #1 14
District(s) Zoning Permit No. Front Rear Left Right
New [] Repair Single Family Entrance Panel Forced Air Furnace
Fuel
[] Alteration [] Raze Two Family Size: 200am [] Radiant Baseboard or Panel
Garage Service: [] Heat Pump Space Htg
[] Addition [] Move [] Other (print): [] Overhead [] Boiler Water Htg
[] Other: [] Underground ~E]] Central Air Conditioning g unit will have 3 kilowatt or
[] Site ConstruCted Concrete Other more installed electric space heating equip
Infiltration control option is: [] Full sealing
Unfinished [] Manufactured Masonry Sewer of joints. [] Blower door test. [] Exterior
Basement 1482 Sq. ft. Treated Wood [] Municipal air infiltration barrier.
Living Area 1482 Sq. ft. 1-Story Other [] Septic
[] 2-Story Permit No. Envelope 28348 BTU/HR
Garage 776 Sq. ft. [] Other [] Seasonal Infiltration 18066 BTU/HR
[] Permanent [] Municipal Utility
[]] Plus Basement [] Other [] Private On-Site Well $132,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creat.e.s no legal liability, express or implied, on the Department or m~uni, jci1~lity; and certifies that all the above information is accurate.
APPLICANT-S SIGNATURE¢.~"~~~-'~~//,.,/,. .... . / DATE SIGNED ~-~--~____~,~¢'-~
Th'i rmlt i i / / '""
APPROVAL CONDITIONS revocation'S pe ' of'Sthis'SSUedper pr~,~rp s/gantothertO pe~altythe IIo¢,~id'g conditions. Failure to comply may result in suspension or
see standard conditions of approval
Town [] Village [] City [] County ~ State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name Nicole Krahn
Inspection Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 3/17/03
Other [] Erosion
Total $105.00 ~ 288723 Cert. No. 248101
SBD-5823 (R. 07/92)
' I
22.5' /
I
~' '"O"j-. ~r~ N / GRAVEL ACCESS DRIVE
~' m l 24' MAX {} LOT LINE/'
j ~ o ~
" 130'
HARRY SALZER
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address ~-'-'~7_~\ ~,_~}~,~\.a.~ ~ Permit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or beloTM ground level must be provided with egress windoWs
. in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire-resistive rating of 20
minutes. Ail drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the. top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
o
Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
All'overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
o
Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough' building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilevered floors with point loads. Floor tresses
and TJI's must be designed for the cantilevered areas.
10.
The propertY owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintain.~ecI~until, t~e;.1.~)~,js esta:bl,~h~l:.:.,
11.
All storm sewer inlets must' be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. RePair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing actiVities.
12.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13.
All mechanicals must be roughed in prior to requesting ihe'r6ughbuilding inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
14.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center~
of the garage floor and a minimum of a 3' pathway must be provided aroUnd' the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16.
Tl~e building placard must remain on the patio door or on a kitchen window Until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with n0-ffirther notic& being
given.
17.
All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.