Loading...
HomeMy WebLinkAbout0100375-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type 3321 LOUISE CT 110 - New Single Family CITY OF OSHKOSH No 0100375 BUILDING PERMIT -APPLICATION AND RECORD Create Date 03/07/2003 Owner HAROLD SALZER Contractor SALZER SIDING Building O Sign O Canopy O Fence O Raze Plan E1-023-0303R Zoning R-1 Class of Const: 8 Unfinished/Basement 1482 Sq. Ft. Rooms 4 Finished/Living 1482 Sq. Ft. Bedrooms 3 Garage 776 Sq. Ft. Baths 2 Foundation O Poured Concrete (~ Floating Slab (~) Pier C) Concrete Block (~) Post C) Treated Wood Occupancy Permit Required Flood Plain No Park Dedication Required # Dwelling Units 1 Height 16 Ft. Stories 1 Other Size Irrg [] Projection Canopies Signs Height Permit Not Required # Structures 1 Use/Nature NSFR/1 story home with a 2 car attached garage, 12'x12' rear concrete patio. of Work HVAC Contractor MCM AIR INC Plumbing Contractor WELLNITZ PLUMBING Electric Contractor SECKAR ELECTRIC Fees: Valuation $77,000.00 Plan Approval $75.00 Permit Fee Paid $311.00 Park Dedication $0.00 Issued By: / Date 03/25/2003 Final/O.P. 00/00/0000 [] Permit Voided In the performance of this work I agree to perform all work pursuant t~p~les governing the described construction. S,gnature ..~-'~.-.~¢.--~¢~j/2¢''~ /~ /--//~/' ',1 Date ~-~,~ ' Address PO BOX 825 OSHKOSH WI 54903 - 0825 Telephone Number (920) 231-5025 OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6910 Name HAROLD SALZER Address 3321 LOUISE CT Create Date 03/07/2003 Lot 14 Block Ward Subdivision Assessors plat #1 Zone Street Number Lot Dimensions L=J_ Sidewalk Existing Building Grade Elevation Stakes Set At Site 03/11/2003 Set By D.W.G. BK - 586, P - 64 Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before exc~/-at~on Wisconsin Department of Industry, Labor'and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 WISCONSIN UNIFORM Application No. BUILDING PERMIT ~_~_ 7 5 APPLICATION IPa~ce~ ~-°- [] Constr [] HVAC [] Etec [] Plbg [] Erosion E~ Other: Mailing Address Telephone No. PO BOX 825 Oshkosh WI 54903 - 0000 Lic/Cert # Mailing Address Telephone No. 7351 PO BOX 825 OSHKOSH WI 54903 - 825 (920) 231-5025 Owner's Name HAROLD SALZER Contractor: [~j conE]] Elec]]]] HVAC bi PIbg SALZER SIDING Contractor: bi Con ~ Elec bi HVACL] Plbg SECKAR ELECTRIC Contractor: ~ I Con ~j Elec[~J HVAC [] Plbg MGM AIR lNG Contractor: L_] Con [] EIoo E]] HVAC[] Plbg WELLNITZ PLUMBING Lic/Cert # 689404 Mailing Address 5920 COURTNEY PLUMMER RD WINNECONNf WI 54986 - 0 Telephone No. (920) 582-4909 Lic/Cert # Mailing Address Telephone No. 4264 6122 COUNTY ROAD M WINNECONNiW154986 - 9780 (920) 582-4402 Lic/Cert Cf Mailing Address Telephone No. 223819 4810AMBERWOOD LN APPLETON WI 54915 -0 (O)231-7390 Sq. ft. 1/4, 1/4,Section ,T N,R E(or)W Block No. Building Address 3321 LOUISE CT Subdivision Name Lot No. Assessors plat #1 14 District(s) Zoning Permit No. Front Rear Left Right New [] Repair Single Family Entrance Panel Forced Air Furnace Fuel [] Alteration [] Raze Two Family Size: 200am [] Radiant Baseboard or Panel Garage Service: [] Heat Pump Space Htg [] Addition [] Move [] Other (print): [] Overhead [] Boiler Water Htg [] Other: [] Underground ~E]] Central Air Conditioning g unit will have 3 kilowatt or [] Site ConstruCted Concrete Other more installed electric space heating equip Infiltration control option is: [] Full sealing Unfinished [] Manufactured Masonry Sewer of joints. [] Blower door test. [] Exterior Basement 1482 Sq. ft. Treated Wood [] Municipal air infiltration barrier. Living Area 1482 Sq. ft. 1-Story Other [] Septic [] 2-Story Permit No. Envelope 28348 BTU/HR Garage 776 Sq. ft. [] Other [] Seasonal Infiltration 18066 BTU/HR [] Permanent [] Municipal Utility []] Plus Basement [] Other [] Private On-Site Well $132,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creat.e.s no legal liability, express or implied, on the Department or m~uni, jci1~lity; and certifies that all the above information is accurate. APPLICANT-S SIGNATURE¢.~"~~~-'~~//,.,/,. .... . / DATE SIGNED ~-~--~____~,~¢'-~ Th'i rmlt i i / / '"" APPROVAL CONDITIONS revocation'S pe ' of'Sthis'SSUedper pr~,~rp s/gantothertO pe~altythe IIo¢,~id'g conditions. Failure to comply may result in suspension or see standard conditions of approval Town [] Village [] City [] County ~ State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name Nicole Krahn Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 3/17/03 Other [] Erosion Total $105.00 ~ 288723 Cert. No. 248101 SBD-5823 (R. 07/92) ' I 22.5' / I ~' '"O"j-. ~r~ N / GRAVEL ACCESS DRIVE ~' m l 24' MAX {} LOT LINE/' j ~ o ~ " 130' HARRY SALZER CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address ~-'-'~7_~\ ~,_~}~,~\.a.~ ~ Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or beloTM ground level must be provided with egress windoWs . in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire-resistive rating of 20 minutes. Ail drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the. top and bottom plates, gaps around heating ducts, and holes in the return air spaces. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. o Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. All'overframing must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. o Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough' building inspection for all microlams with point loads on them. Calculations must be provided for all cantilevered floors with point loads. Floor tresses and TJI's must be designed for the cantilevered areas. 10. The propertY owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintain.~ecI~until, t~e;.1.~)~,js esta:bl,~h~l:.:., 11. All storm sewer inlets must' be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. RePair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing actiVities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting ihe'r6ughbuilding inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center~ of the garage floor and a minimum of a 3' pathway must be provided aroUnd' the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. Tl~e building placard must remain on the patio door or on a kitchen window Until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with n0-ffirther notic& being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor.