HomeMy WebLinkAbout0066831-Plumbing (interior) CITY OF OSHKOSH No 0066831
OSH' OSH PLUMBING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 150 ROLLING GREEN CIR Owner CONTEMPORARY HOMES Create Date 07/22/98
Contractor P &S PLUMBING Category 410 - Residential- Interior Plan
Bathtub 1 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 4 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 4 Lndry Stndp 1 Clothes Wshr Ice Chest FIr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type is Gonn. Type
Sanitary Sewer
Storm Sewer
Water Service
Valuation $6,400.00 Plan Approval $0.00 Permit Fees $68.00
Issued By Date 10/15/98
Li Permit Voided
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature
Date
Agent/Owner
Address PO BOX 2153 APPLETON WI 54913 - 0 Telephone Number 734 -3912
Plumbing Permit Work Card
Job Address 150 ROLLING GREEN CIR Permit Number 0066831 Create Date 07/22/98
Owner CONTEMPORARY HOMES Contractor P &S PLUMBING
Category 410 - Residential- Interior Plan Value $6,400.00
htub 1 Shower / 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory '11/ 4 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet J / 4 Lndry Stndp f 1 Clothes Wshr Ice Chest Fir/Wst Sink Int Grease Trap
Res. Sink f 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump f 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
ize 'f atena ype onn. ype
Sanitary Sewer ja./.4.4--
(J( CT/ f t /e7/7// /(9 O
Storm Sewer L /2-//g I
....ter Service
Date Type Inspector Approved
A
/ R OLL /,tiG 6-11 a -r
WATER CALCULATION WORKSHEET i 2
Information Needed for Water Service Sizing S H a w ascs c crsTciy �"aS
1. / Demand of building in gallons per minute. (2 5 , 5 u' F - )
2. 5 Low pressure at main in street (or at external pressure tank).
3. S Difference in elevation from main to meter (or external pressure tank to building
control valve).
4. 3 "/ „Size of water meter (if applicable).
5. % ! r Developed length from main to meter (or external pressure tank to building
control valve).
You Must First Find the Available Pressure After the Water Meter
•
(or at building control valve). To obtain this pressure, you must:
if 6. g, `/Y Find pressure loss due to friction in I inch water service.
7. 2.17 Find pressure loss due to elevation, main to meter (or external pressure tank to
building control valve). Multiply the difference in elevation by .434 p.s.i. /ft.
8. V Find pressure loss due to meter. (from manufacturer or AWWA).
9. '57,37 Subtract the loss due to friction (Step 6), loss due to elevation (Step 7), and loss
due to meter (Step 8) from the low main pressure (or low pressure at external
pressure tank). This calculation is the available pressure after the water meter (or
at the building control valve). This answer is entered in Line B, below.
Information Needed for Water Distribution Sizing
Using the following formula, find the pressure available for uniform loss (p.s.i /100' of pipe)
A= B- (C +D +E)x100
WHERE: F
A. - 3 0 Pressure available for uniform loss (p.s.i. /100' of pipe).
B. 37,3 Available pressure after water meter (at the building control valve or low pressure
at internal pressure tank). (See item 9, above).
C. f Pressure needed at controlling fixture.
D. 4., 9'/ Difference in elevation between water meter (building control valve or internal
pressure tank) and controlling fixture in feet 1 x .434 p.s.i. /ft.
E. - 0 — Pressure loss due to water softeners, water treatment devices, instantaneous
water heaters and backflow preventers. Conventional water heaters usually do not
have a pressure loss.
F. '7 5 Developed length from water meter (building control valve or internal pressure
tank) to controlling fixture in feet 5d x 1.5.
With pressure available for uniform loss, go to applicable table for distribution sizing.
SRD - 6479 (R. 08/88)
TAG"- R2.tio -S
34 _
tr 2 '7