HomeMy WebLinkAboutPlumbing H1-400-0810-P (08/24/2010) 0 Oshkosh Plan Approval Form
OSHKOSH
ON THE WATER
Job Address 1020 -1142 S KOELLER ST Approval Number 3115
Approval Type Plumbing Plan H1 -400- 0810 -P
Submitter's Name McMillan Pazdan Smith Net Days to
Address 200 EAST BROAD ST, SUITE 300 Complete Review
GREENVILLE SC 29601 - 2
Owner Name KOELLER ONE LLC
Address 1818 W BELTLINE HWY
MADISON WI 53713 - 2334
Type of Plan Interior Remodel -Hobby Lobby (1118)
Fee $260.00 Date Received 08/11/2010 Date Approved 8/24/2010
City of Oshkosh
Inspection Services
215 Church Ave., PO Box 1130
Oshkosh, WI 54902 -1130
(920) 236 -5052 (920) 236 -5184 FAX
O.fHKOJH
ON THE WATER
August 24, 2010
McMillan Pazdan Smith
200 East Broad St. Suite 300
Greenville, SC 29601
Interior Plumbing Remodel -Hobby Lobby
Ref: Plumbing Plan Approval: 1020 -1142 (1118) S Koeller St., Oshkosh, WI
Plan ID# H1- 400 - 0810 -P
Dear Sirs,
Examination of the plumbing plans and specifications for this project has been completed. In
accord with Chapter 145, Wisconsin Statute, and COMM 81 through 85, Wisconsin
Administrative Code, the plumbing plans and specifications are approved contingent upon
compliance with the stipulation(s) noted below.
1. The plumber responsible for the installation shall keep at the construction site at
least one set of plans bearing the department's or agent municipality's stamp of
approval and least one set of specifications. The plans and specifications shall be
open to inspection by an authorized representative of the department. Comm.
82.20(6)
2. Per Comm. 82.41(3)(a) water supply systems shall be protected against
contamination due to cross connections or backflow conditions by one of the
methods or devices specified in Table 82.41 -1 depending upon the situation or
Table 82.41 -2 depending on specific application or use, and the limitations specified
in sub. (4). A water supply feed trap seal primer valve is required to comply with
ASSE 1018.
3. Per Comm. 82.41(3)(a) water supply systems shall be protected against
contamination due to cross connections or backflow conditions by one of the
methods or devices specified in Table 82.41 -1 depending upon the situation or
Table 82.41 -2 depending on specific application or use, and the limitations specified
in sub. (4). Wall hydrant is required to meet ASSE 1019 type A or B.
4. Per Comm. 82.31(3)(b) each gravity -flow sanitary building sewer shall be served by
at least one stack which extends from a building drain to a vent terminal or vent
header. The stack shall not be less than 3" in diameter from the building drain to the
vent terminal or vent header. The submitted plan does not reflect this code
requirement, field verification is required.
5. Per Comm. 82.20(8) all changes or modifications, which involve the provisions of
chs. Comm. 82 to 84, made to the plumbing plans and specifications, which have
been granted approval under sub. (1), shall be submitted to the department or agent
municipality for examination. All changes and modifications shall be approved in
writing by the department or agent municipality prior to the installation of the
plumbing.
In the event installation of this plumbing system has not commenced within two years from this
date, this approval shall become void. A new application accompanied by full examination
fees shall be filed and an updated approval received before work may commence.
In granting this approval, the City of Oshkosh or its representative does not hold itself liable for
any defects in plans or specifications, plan omissions, examination oversight, construction or
any damage that may result in or after installation. The City of Oshkosh reserves the right to
order changes or additions should conditions arise making this necessary.
It shall be necessary for the installing plumber to obtain a plumbing permit from the City of
Oshkosh before proceeding with actual installation of this plumbing system or any of its parts.
Respectfully,
Paul Wolf,
Plumbing Inspector