Loading...
HomeMy WebLinkAboutBuilding N8-3118-0810 City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903 -1130 0/1-KO n i www.ci.oshkosh.wi.us ON THE WATER I�l August 23, 2010 Thomas Karrels T.R. Karrels & Associates 1934 Algoma Blvd. Oshkosh, WI 54901 Ryan Meyers Oshkosh Corporation 2307 Oregon St Oshkosh, WI 54902 Site: Plan Number: N8- 3118 -0810 Oshkosh Corporation — North Plant 2307 Oregon St Oshkosh WI 54902 For: Description: 1" floor office alterations Object Type: Building only Class of Construction: IIB - 3300 Sq Ft.; sprinklered Occupancy: B: Business / Office The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: • IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code and the international fire code. Construction of new walls may require the addition and or relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers • IFC 901.4 Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. Submit plans for fire sprinkler modifications. • IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. • IBC 1011 Exit signs are required to be installed per this section • IBC 1006.1 Means of egress illumination is required to be installed per this section • IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1006.4. Existing means of egress emergency lighting is permitted to be maintained in compliance with the code in effect at the time of construction. Any altered path of egress or new path of egress, and any new emergency lighting being installed is required to comply with current code requirements. 11:` •briann''2010 Comm Plan P.zvie;v;'.N3 -31 I S -0810 2307 Oregon St Blda Oab.dnc Page 1 of 2 • Comm 61.30(3) — This approval does not include heating, ventilating or air conditioning. The owner should be reminded that HVAC plans, calculations and appropriate fees are required to be submitted for review and approval prior to installation. The State of Wisconsin, Safety and Buildings division offers a number of worksheets and checklists for Commercial Building Code at http: // commerce. wi. gov /SB /SB- CommBldgPlanRevInfo.html that may assist you in preparing this submittal. Building Designer should coordinate with HVAC designer to avoid problems with clearance to combustibles, dampers etc. The submitted HVAC plans shall match the approved building plans. Building Designer is requested to provide complete set of Plans, Energy Calculations and Building Plan Review Letter to the HVAC Designer to help coordinate review. Note as per Comm 2.10 installation of HVAC without approved plans could result in double fees. • Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). SUBMIT: • IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1006.4. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. • Comm 61.40 (4) Supervision. Prior to the initial occupancy of a new building or addition and prior to the final occupancy of an alteration of an existing building the supervising professional shall file a compliance statement form SBD - 9720 with this office. Note: Submittal of a compliance statement will be considered as evidence that the supervising professional has properly addressed all items identified in this plan review letter. A copy of the approved plans, specifications, and this letter shall be on -site during construction. If plan index sheets were submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the copy on file in this office. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. The City of Oshkosh does not take responsibility for the design or construction of the reviewed items. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. Resp , Brian oe Building Systems Consultant (920) 236 -5051 bnoe @ci.oshkosh.wi.us cc: Property file Fee Required $ 450.00 Fee Received $ 450.00 Balance Due $ 0.00 it b, iann 2010 Comm Plan Review;;1'1a-311S-0810 2307 Oregon St Bldg Only doe Page 2 of 2