Loading...
HomeMy WebLinkAbout0142480-Electric (new service) CITY OF OSHKOSH No 142480 OSHKOSH ELECTRIC PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 3321 COUNTY RD A Owner NONWEILER INVESTMENTS LLC Create Date 08/09/2010 Contractor WITZKE ELECTRIC INC Category 651 - Industrial -New Service Plan Service • New O Change 0 Temp 0 N/A Type 0 Overhead • Underground Volts 277/480 Circuits Luminaires Amps 2000 Switches Receptacles Appliances Use /Nature of Installation of a new service on the NE corner of the building which will back -feed the existing service and the addition of a 600A 480V Work service for a fire -pump located on the west end of the building. *A.P. Non - Weiler * *debit acct Fees: Valuation $75,000.00 Plan Approval $0.00 Permit Fee Paid $438.00 Issued By: Date 08/09/2010 ❑ Permit Voided I Parcel Id # 1519607400 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address PO BOX 102 OSHKOSH WI 54903 - 102 Telephone Number (920) 235 -6572 To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. AUG. 9.2010 8 :50AM WITZKE ELECTRIC N0.291 P.1 City of Oshkosh Division of Inspection Services P.O. Box 1130 Oshkosh, WI 54903.1130 t r -\11411,, Phone (920) 236.5050 Fax (920) 236.50,34 ' K ON MP WA ELECTRICAL PERMIT APPLICATION All information after bold categories must be provided. Incomplete applications will not be processed. • Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI '54903.112S. Commencing work without permit(s) will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. OR v u or con arrr tin a Pe it ecount Svstern, and have adequate funds. check her i v r w hls recessed through vour account ® 0//0 DATE JOB ADDRESSJ$Q / ei1' 7L 4 OWNS /OY.l Wet. . CONTRACTOR \III l fzkci El eztric Inc - CHECK LI ALL APPLICABLE USE CATEGORY ClSingle Family ODuplex ❑ Multi - Family ❑Rental 0Commercial ArIndustri al SERVICE *ew ❑Temporary TYPE ❑Overhead CiNot Applicable ❑Change ❑Not Applicable underground FILL IN THE APPROPRIATE BLANK WITH THE NYYMBER Volts 6977 / Iiiu Receptacles # Circuits # Phase '$ Amps Switches # Fixtures # CHECK Lf ALL APPLICABLE Range ❑Dishwasher ❑Garbage Disposal ❑Dryer ❑Water Heater ❑Fan OR Blower ❑Furnrnace DA/C ElElectric Sign ❑Motors CIGas Pumps ❑Other DESCRIPTION OF ALI WORK BEING DONE ,. _5 r/1 —I, 14/ is __L._ r ,0 :irrr e.rr iewiam, VALUE (Including labor and all materials including light fixtures) S 7.5;o°61 ` ob BLASTER ELECTRICIAN ---_1_,,?.mt. Q—cDe, Received Time Aug. 9. 2010 8:51AM No.2323 3v02 , I Electric Permit Work Card J ob Address 3321 COUNTY RD A Permit Number 142480 Create Date 8/9/2010 Owner NONWEILER INVESTMENTS LLC Contractor WITZKE ELECTRIC INC Service . New 0 Change() Temp 0 N/A Type 0 Overhead • Underground O N/A Volts 277/480 Circuits Luminaires Amps 2000 Switches Receptacles Value $75,000.00 Use /Nature Installation of a new service on the NE corner of the building which will back -feed the existing service and the addition of a of Work 600A 480V service for a fire -pump located on the west end of the building. *A.P. Non - Weiler * *debit acctapproved 1 i i Inspections: Date 08/18/2010 Type Underground Inspector Adam Krause approved Request line / Wants to know if you want to inspect the underground conduits. Trench is open. Please call Dan and let him know if you are going to inspect. ■ I i L Date/Time requested: 08/17/2010 03:06 PM Notice Type: Ready Date/Time: 08/17/2010 03:06 PM Access: — Requested by: WITZKE ELECTRIC INC - Dan Phone Number: 379 - 4 0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 10/01 /2010 Type Service Inspector Kevin Benner — t�� approved QUAKED conducting GFP test this morning . eviewed with Charlie & Dan while on site. 65KAIC MCB Faxed to WPS 10/4/10 Date/Time requested: 09/30/2010 07:46 AM Notice Type: Ready Date/Time: 09/3 07:46 AM Access: Open - - - - - -- - - -- Requested by: WITZKE ELECTRIC INC - Dan Phone Number: 379 -4967 0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid • SQARE LD Services Division Schneider Electric LV Circuit Breaker ,RVIUMf a New his. -mu `f '," kJ 1- 888 - 778 -2733 (Manually Operated) REFERENCE INFORMATION Contact Name: FSR: LARRY AKSTULEWICZ Job No: 29106562 -001 Customer Site: WITZKE ELECTRIC Customer Ref No: 0224189 DBID: 21- 284160 C/O A P NONWEILER CO. Date: September 30, 2010 3321 NORTH SHORE DRIVE OSHKOSH, WI 54903 IDENTIFICATION Sub Station Location: North Main Service Customer Asset ID: Sub ID: Main Circuit ID: Main NAMEPLATE DATA Manufacture: Manufacture Date: Serial No: Type: Square D 10363 06411117170001 RK2000 Frame Size: Rated Amps: Sensor Rating: Rating Plug: 2000 Amps 2000 Amps 2000 Amps 2000 Amps Fuse Type: Fuse Manufacture: Fuse Model /Catalog No: Fuse Rating: Square D Trip Unit Type: Trip Curve No: Interrupt Rating: Mounting: Micrologic 6.0A n/a 65 KA Fixed Number of Operations: Number of Operations: INSPECTION CHECKLIST ITEM AS LEFT ITEM AS LEFT Blown Fuse Indicator (BFI): Not Applicable Switch Condition: Acceptable Interlocks: Not Applicable Primary Disconnects: Not Applicable Over - Travel Stops: Not Applicable Secondary Disconnects: Not Applicable Mechanical Wear: Not Applicable Ground Contacts: Acceptable Mechanical Lubrication: Not Applicable Main Contacts: Tested Intermediate Contacts: Not Applicable Arcing Contacts: Not Applicable Trip Free Test: Acceptable Pri.Current Path Lubrication: Not Applicable Manual Close Test: Acceptable Arc Chutes: Not Applicable Spring Discharge: Not Applicable Interphase Barriers: Not Applicable Insulated Linkages /Bracing: Acceptable Gap / Wipe Settings: Not Applicable Contact Alignment / Acceptable Sequence: Test Report, 29106562 - 001 4. INSPECTION NOTES Generic Note Ground Fault sytem was primary injected with 510 amps, Main circuit breaker GF set at 500 amps, tripped with a time of 0.129 seconds. Ground Fault system operates as designed. INSULATION RESISTANCE TEST Test Equipment ID: Calibration Date: 1/10 FSR: 7072 Test Voltage: 500 Megger Tests are performed with breaker Tests are performed with breaker CLOSED and all unenergized poles grounded OPEN and all unenergized poles grounded AS FOUND AS LEFT AS FOUND AS LEFT AToB 90GS2 KS2 ALINE TO LOAD 1.5TS2 K AToC 127GS2 KS2 B LINE TOLOAD 1.5TS2 KS2 BToC 129G12 K12 CLINE TO LOAD 1.5TS2 KS2 A TO GROUND 53.2 G S2 K E2 B TO GROUND 56.3 G 12 K 0 TEMPERATURE 60 °F °F C TO GROUND 61.7 G E2 K E2 HUMIDITY 55 % % CONTROL WIRING TEST Test Voltage: Kv As Found: As Left: CONTACT RESISTANCE TEST Test Equipment ID: Ductor Calibration Date: 1/10 FSR: 7072 THROUGH PRIMARY DISCONNECT FINGERS AND /OR BYPASS PRIMARY DISCONNECT FINGERS AND /OR FUSES FUSES (IF APPLICABLE) (OR NO PRIMARY DISCONNECT FINGERS AND /OR FUSES) AS FOUND AS LEFT AS FOUND AS LEFT PHASE A PHASE A 20 p S2 PHASE B PHASE B 19 p 12 PHASE C PHASEC 16NS2 OVER CURRENT PROTECTION - TRIP UNIT DATA Test Equipment ID: FFTS Calibration Date: 1/10 FSR: 7072 Manufacture: Square D Trip Device Serial #: 6.0A Style: Micrologic Battery Status As Found: Pass As Left: Pass Settings CT Coil Ratings: CT Tap Ratings: Rating Plug: 2,000 As As As Left I *2T As As As Left I *2T Found Tested Setting ON Found Tested Setting ON Setting Setting Setting Setting Long Time Pickup 1 1 1 Instantaneous Pickup 2 2 2 Long Time Delay .5 .5 .5 Ground Fault Pickup A A A Short Time Pickup 1.5 1.5 1.5 Ground Fault Delay .1 .1 .1 Yes Short Time Delay .1 .1 .1 Yes Test Report, 29106562 - 001 5. TRIP UNIT TIMING TEST (measured in Seconds) Trip Device Test Current Specified Range Phase A Phase B Phase C Function Amps Amp Range Minimum Maximum As Found As Left As Found As Left As Found As Left Long Time 2,667 10 15 13.88 13.88 13.88 Short Time 3,500 3 8 5.106 5.106 5.106 Instantaneous 5,000 0.005 0.05 0.036 0.036 0.036 Ground Fault 1,000 0.05 0.5 0.131 0.131 0.131 Test Report, 29106562 - 001 6.