Loading...
HomeMy WebLinkAbout2005-Final (Bldg & HVAC) 0 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 5/17/05 Compliance Date 6/16/05 Compliance No Address 1740 ROBIN AVE Name Address City State Zip Code Sent to u Owner ZANGL & SHIELDS LLC W162 N9651 MAYFLOWERDR GERMANTOWN WI 53022 -0000 Introduction u Required for Occupancy Occupancy The following violations were noted at the final building and heating inspection. It would appear that the building was built to the former Commercial Building Code. In checking the file it was noted that the plans were approved under the IBC, therefore the old code can not be used. I have enclosed copies of the IBC code requirements for your information. Item # 1 Code IBC 1003.3.3.3 Compliance No Compliance Date 06/16/2005 Description The maximum riser heights shall be 7.75 inches and the minimum tread depth shall be 10 inches. A nosing not Tess than .75 inch but not more than 1.25 inches shall be provided on stairways with solid risers where the tread depth is less than 11 5/17/05 inches. Last Updated Item # 2 Code IBC 1003.3.3.3.1 Compliance No Compliance Date 06/16/2005 Description Stair treads and risers shall be of uniform size and shape. The tolerance between the largest and smallest riser shall not exceed .375 inch in any flight of stairs. 5/17/05 Last Updated Item # 3 Code IBC 1003.1.12.1 Compliance No Compliance Date 06/16/2005 Description Guards shall form a protective barrier not less than 42 inches high. The half wall for the 2nd floor stairways shall be a minimum of 42 inches high. 5/17/05 Last Updated Item # 4 Code IBC 2104.8 Compliance No Compliance Date 06/16/2005 Description Weep holes shall be provided in the outside of masonry walls at a maximum of 33 inches on center. Weep holes shall not be less than 3/16 inch in diameter. 5/17/05 Last Updated Item # 5 Code IMC Compliance No Compliance Date 06/16/2005 Description Submit the dryer venting installation instructions due to the long venting lengths. Duct tape is not an approved fastening means for the metal ducting for the dryer venting. 5/17/05 Last Updated Item # 6 Code NOTE Compliance No Compliance Date 06/16/2005 Description Occupancy will not be allowed until the drainage related issues are resolved with the City of Oshkosh Public Works Department. 5/17/05 Last Updated 10090 Page 1 of 3 0 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 5/17/05 Compliance Date 6/16/05 Compliance No Address 1740 ROBIN AVE Name Address City State Zip Code Sent to U Owner ZANGL & SHIELDS LLC W162 N9651 MAYFLOWERDR GERMANTOWN WI 53022 -0000 Introduction HI Required for Occupancy Occupancy The following violations were noted at the final building and heating inspection. It would appear that the building was built to the former Commercial Building Code. In checking the file it was noted that the plans were approved under the IBC, therefore the old code can not be used. I have enclosed copies of the IBC code requirements for your information. Item # 7 Code NOTE: Compliance No Compliance Date 06/16/2005 Description Final grading and paving is required to be completed. 5/17/05 Last Updated 10090 Page 2 of 3 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 5/17/05 Compliance Date 6/16/05 Compliance No Address 1740 ROBIN AVE Name Address City State Zip Code Sent to u Owner ZANGL & SHIELDS LLC W162 N9651 MAYFLOWERDR GERMANTOWN WI 53022 -0000 Introduction U Required for Occupancy Occupancy The following violations were noted at the final building and heating inspection. It would appear that the building was built to the former Commercial Building Code. In checking the file it was noted that the plans were approved under the IBC, therefore the old code can not be used. I have enclosed copies of the IBC code requirements for your information. Item # 8 Code NOTE Compliance No Compliance Date 06/16/2005 Description Occupancy is not allowed until the occupancy permit is issued and all final inspections are approved. It was noted at the final inspection that unit #1 was occupied. Citations may be issued if this unit is not vacated. 5/17/05 Last Updated Summary The violations are required to be corrected within the next 30 days. Occupancy is not approved and citations will be issued if the units are occupied without approval. If you have any questions feel free to contact me at 236 -5036. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 6/16/05 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 - 1:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. Signature k.) Date � 7 /d Inspected by: Nicole Krahn 236 -5036 nkrahn @ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: U Bldg - u Elec - U HVAC - U Plbg - U Designer - U Other J _ 0 -0000 U Inspector 10090 Page 3 of 3