HomeMy WebLinkAbout2002-Cross Connection (trans id#822278) Safety and Buildings 401 PILOT CT STE C WAUKESHA WI 53188 -2439 www.o ,SCOfSiI fl TDD #: (608) 284 -8777 anmeroe.state.wi.us/sb Department of Commerce www•wisoonsin•gov Scott McCallum, Governor Philip Edw. Albert, Secretary December 20, 2002 CUST ID No.232866 ATTN Plumbing Inspector - RICHARD A BIESE MUNICIPAL CLERK TT SCHMIDT PLUMBING INC CITY OF OSHKOSH 419 S WASHINGTON ST PO BOX 1130 COMBINED LOCKS WI 54113 OSHKOSH WI 54903 -1130 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 12/20/2004 Identification Numbers Transaction ID No. 822278 SITE: Site ID No. 643853 Evco Plastics Please refer to both identification numbers, max. 450 West Ripple Ave above, in all correspondence with the agen+y:'; City of Oshkosh, 54902 -8807 Winnebago County FOR: Description: Serving Cistern Object Type: Cross Connection Control Device Regulated Object ID No.: 885406 Device Type: Reduced Pressure Preventer; Location On Property: Ne Corner of Building; Manufacturer: Watts; Model: 909; Plan Type: Alteration; 3/4" Valve Size The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Key Items 1. Comm 82.41(5)(e)3.a. If an Rp is located within a building, a drain or approved receptor shall be provided to receive the vent port discharge. The floor drain or receptor to receive the discharge of the reduced pressure principle backflow preventer relief valve shall be sized to handle the anticipated discharge. 2. Comm 82.40(3)(d)3. The installation of each RP, RP detector, PVB and SVB shall display a department assigned identification number. 3. The backflow preventer shall be installed so that the relief valve outlet is protected by an approved air - gap. The drain from the relief valve must discharge to either a floor drain or an approved receptor. No part of the backflow preventer may be submerged under any circumstance. 4. RP, PVB, or SVB's shall not be by- passed. Except for repair, they shall not be made inoperative or removed without departmental approval. 5. It is the responsibility of the owner to make sure the device is tested and that the test report forms (SBD- 9927) is sent to the Safety and Buildings Division upon completion of the test. A department- listed Backflow Prevention Device Tester shall perform the test. A list of testers is available from the department upon request. 6. A TEST SHALL BE CONDUCTED ON EACH RP,PVB, OR SVB PRIOR TO IT BEING PUT INTO SERVICE, AND A MINIMUM OF ONCE A YEAR THEREAFTER. RICHARD A BIESE Page 2 12/20/02 A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of construction /installation/operation. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, Fee Required $ 125.00 0Fee Received $ 125.00 Balance Due $ 0.00 Chet Kintop General Plumbing Plan Reviewer , Integrated Services W (262) 548 -8634, Fax: (262) 548 -8614 , Monday - Friday 07:45 To 4:30 ckintop @commerce.state.wi.us cc: James E Zickert , Plumbing Consultant, (920) 948 -7336 Evco Plastics