Loading...
HomeMy WebLinkAbout2010-Building (new wall) CITY OF OSHKOSH No 142063 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 923 S MAIN ST Owner TDS PROPERTIES LLC Create Date 06/30/2010 Designer T- Karrels Contractor FOX RIVER DEVELOPMENT CO Category 223 - Alteration Offices, Banks, Professional Plan Type • Building 0 Sign 0 Canopy 0 Fence O Raze Zoning Class of Const: Size Unfinished/Basement Sq. Ft. Rooms Height Ft. ❑ Projection Finished/Living Sq. Ft. Bedrooms Stories Canopies Garage Sq. Ft. Baths Signs Foundation • Poured Concrete 0 Floating Slab O Pier 0 Other 0 Concrete Block O Post 0 Treated Wood Occupancy Permit Not Required Occupancy Fee $0.00 Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units 0 # Structures 0 Use /Nature Construct new 9'-6" wall to separate storage areas as per plans. 'O.K. to issue of Work HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation �.�.� $2,500.00 Plan Approval $0.00 Permit Fee Paid $39.00 Park Dedication $0.00 Issued By: �X, Date 07/16/2010 Final /O.P. 00 /00 /0000 ❑ Permit Voided Parcel Id # 0301980000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure an • - - ary approvals before starting such activity. I have re -. - • . • rstand t - afore coned info ation. � Signature Date / "o /� Agent/Owner Address Oshkosh WI 54901 - 0000 Telephone Number 235 -7784 To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. City of Oshkosh Inspection Services Division P O Box 1130 Oshkosh, WI 54903 -1130 Phone: (920) 236 -5050 Fax: (920) 236 -5084 OJHKOJH Building Permit Application ON THE WATER If you are a contractor participating in the Permit Fee Account System and have adequate funds, check here if you want this processed through your account n JOB ADDRESS 92.3 OWNER / /2S Pe. at Cf CONTRACTOR P .--47 > i - C. Q tJ, I am the: ❑ Owner OR E Contractor USE CATEGORY ❑Single Family ❑Duplex ❑Multi - Family ❑Rental Commercial ❑Industrial Work being done: ❑ Addition ❑ Deck/Porch/Patio ❑ Dri eway/Parking ❑ Extemal Remodeling ❑ Fence/Hedge/Kennel ❑ age/Utility Structure ❑ Handicap Ramp ❑ Hot Tub /Spa Internal Remodeling ❑ Sign/Canopy /Awning ❑ Stair/Handrail ❑ Stove/Fireplace ❑ Swimming Pool ❑ Wrecking Permit ❑ Other Additional information, such as plan submittal and approval, may be required before issuance. Fliers, located in the hallway, may be referenced to note if any additional information is necessary. • Full description of work being done: p '7 -h , � // 044. 2 , "-Ad] /% t h /7 % 4 /' 4 �ci/ 0".ely c�c� s //f ✓�� E ■ `y / � / Any work not included in this application is not permitted. Value of the job $ 2 J ® � (Value for materials and labor is required to ensure consistency in accessing permit fees for all applicants.) PLEASE READ, SIGN, & DATE: I certify the above information is complete and accurate. Any deviations from the above submitted information may require additional permits to be obtained. I acknowledge and agree to these terms. Name: � . 't pv S ( yob v b 73 (Please print) Signa - • D / Date: 3/02 6 CLEAR' 31 36 , m 5 O 28 1 NEW LOCATION 23 25 ' 30 35 33 E ISTI �G STORAGE/ WORK AF EA 27 I I 22 22 22 5 GENERAL NOTE S k- )(ISTiNO 15. 2x10 JOISTS ICLG.I 0 16 "o /c w/ 518" DRYWALL FINISHED /PAINTED OFFICE ._ 5 ,w, BELOW & 3/4" OSB SHEATHING ABOVE, BEAR ® 8' -0'. PROVIDE SIGN THAT READS "NO STORAGE ON DECK ABOVE''. EXISTING � a a5, --, I(� C. 5 TOILET EXISTING b OF I E In Z R,, J+€ F61+1= VARf, PAINTED. O N ' O O EXIST IN 9'- 5 " =AF.F. PAINTED, EQUI,PIVE NT 8. INSULATE EXISTING STUD CAVATIES, PROVIDE 055 SHEETS TO i Q !n CLOSE OPENING AS REQUIRED. EXISTING EXISTING EXISTING O Y 9. NEW 2x4 STUDS a@ 16 11 0 /c TO HEIGHT OF 9' -5 11 s w/ INSULATION 6 BREAK/ OFFICE OFFICE 29 23 5 s CONFERENCE O 1 20. EXISTING SLIDING DOOR 8 TRACK TO BE REMOVED, CLEAR' 31 36 , m 5 O 28 1 NEW LOCATION 23 25 ' 30 35 33 E ISTI �G STORAGE/ WORK AF EA 27 I I 22 22 22 5 GENERAL NOTE S k- )(ISTiNO 15. 2x10 JOISTS ICLG.I 0 16 "o /c w/ 518" DRYWALL FINISHED /PAINTED OFFICE ._ 5 ,w, BELOW & 3/4" OSB SHEATHING ABOVE, BEAR ® 8' -0'. PROVIDE SIGN THAT READS "NO STORAGE ON DECK ABOVE''. Y 16. 2z6 STUDS ® 16 "o.c. w/ INSULATION FOR SOUND AND C. 5 EXISTING b OF I E In Z EX MEN P� 5 2 � KEY NOTES TO THIS SHEET IOI AV , 1. ALIGN NEW STUD WALL CONSTRUCTION WITH EXISTING. t! 2 ___ NOT USED Z O - 3. NEW STUD WALL CONSTRUCTION TO DIE INTO EXISTING H STRUCTURAL WINDOW MULLION. Q_ cr 4. 3' -0" x W -8" FULL LIGHT WOOD DOOR AND FRAME, CLEAR N ? 1 &+ GLASS. Q A4 R #, 3 5. EXISTING DOOR /FRAME /HARDWARE TO REMAIN UNCHANGED. 6. 3--O- FLUSH SOLID COOR WOOD DOOR AND FRAME, 7. EXISTING THRESHOLD TO BE REMOVED TO ALLOW BARRIER FREE ACCESS BETWEEN FRONT AND REAR AREAS. CONTRACTOR OPTION WOULD BE TO REMOVE EXISTING DOOR /FRAME AND PROVIDE NEW FLUSH SOLID CORE WOOD DOOR AND FRAME SIZE TO MATCH EXISTING w (MIN, 3'-0" x D B. NEW PUSH /PULL HARDWARE, CLOSER b DEADBOLT, FINISH TO MATCH EXIST. 9. NEW LOCKING LATCH SET, STYLE AND FINISH TO MATCH EXISTING 10. EXISTING DOOR /FRAME ASSEMBLY TO BE REMOVED AND RELOCATED WHERE SHOWN, VERIFY CONDITIONS IN FIELD, 11. NEW 2.4 STUDS 0 16 11 o/c w/ INSULATION FOR SOUND AND 5/8" DRYWALL EACH SIDE. WALL TO EXTEND TO HEIGHT OF OFFICE /RETAIL EXIST. TRUSS BOTTOM CHORD (APPROX. 9' -5 "I. WALL TO BE , SPACE LOCATED ADJACENT TO EXISTING STAIR CONSTRUCTION. 12. EXISTING STUD WALL TO BE REMOVED 8 MODIFIED AS °i °1 ° 0 LL REQUIRED TO ACCOMODATE NEW DOOR /FRAME OPENING. - - 13. EXISTING OPENING TO BE INFILLED w/ STUDS, INSULATION b DRYWALL, AS REQUIRED. FINISH 8 PAINT TO MATCH EXISTING ADJACENT. 14. NEW 2.4 STUDS 0 16" o/c w/ 5/8" DRYWALL AT CORRIDOR Q SIDE ONLY, WALL TO EXTEND TO HEIGHT OF 8' -O ", PAINTED. i P 5 EXISTING FFI EXIST, Wnnd F-N1 VISITOR WAITING EXISTING EXISTING OFFICE OFFIC _j b FIRST FLOOR PLAN 1 /4" • 1' -0" NORTH 23 25 EXISTING STORAGE/ WORK AREA 1 IM EXISTING CONSTRUCTION TO REMAIN SHOWN SHADED • ALL NEW DRYWALL WALLS TO BE FINISHED AND PAINTED TO MATCH EXISTING, OR AS DIRECTED BY OWNER. • ALL EXISTING CEILINGS TO REMAIN UNCHANGED NEW WALLS ARE TO EXTEND TO UNDERSIDE OF EXISTING FINISH CEILINGS. • ALL EXISTING FINISH FLOORING TO REMAIN UNCHANGED, NEW STUD WALLS ARE TO BE CONSTRUCTED OVER EXISTING FLOOR FINISHES. • ALL NEW WOOD DOOR CASINGS, WOOD BASE, ETC, TO MATCH EXISTING, PAINTED. • ALL NEW WOOD DOORS AND FRAMES TO BE PAINTED TO MATCH EXISTING, ADDITIONAL EMERGENCY EGRESS LIGHTS TO BE PROVIDED AS REQUIRED. PROVIDE 4" VINYL BASE AT DRYWALL WALLS IN EXISTING STORAGE/ WORK AREAS to EXISTING OFFI 12 EXISTING 0 FO FICE b NEW LOCATION ---^ S 15. 2x10 JOISTS ICLG.I 0 16 "o /c w/ 518" DRYWALL FINISHED /PAINTED ._ BELOW & 3/4" OSB SHEATHING ABOVE, BEAR ® 8' -0'. PROVIDE SIGN THAT READS "NO STORAGE ON DECK ABOVE''. 16. 2z6 STUDS ® 16 "o.c. w/ INSULATION FOR SOUND AND 5/8DR " YWALL EACH SIDE E WALL TO T° xI O aG 1 In Z J+€ F61+1= VARf, PAINTED. O N ' 17. NEW 5/8" DRYWALL OVER EXISTING OSB SHEATHING TO EXTEND 3 9'- 5 " =AF.F. PAINTED, 8. INSULATE EXISTING STUD CAVATIES, PROVIDE 055 SHEETS TO !n CLOSE OPENING AS REQUIRED. O Y 9. NEW 2x4 STUDS a@ 16 11 0 /c TO HEIGHT OF 9' -5 11 s w/ INSULATION 6 In 5/8" DRYWALL, PAINTED. O 1 20. EXISTING SLIDING DOOR 8 TRACK TO BE REMOVED, J21, EXISTING HEADER-TO REMAIN & BE - SUPPORTED BY NEW STUD WALL. 22. REMOVE EXISTING SPRINKLER PIPING AND ASSOCIATED z HANGERS, EXISTING SYSTEM HAS BEEN PREVIOUSLY O DEACTIVATED b ABANDONED. f'- 23.EXISTING CEILING PANELS TO BE RE- SECURED IN PLACE TO Q EXISTING STRUCTURE ABOVE. ANY MISSING PANELS ARE TO BE REPLACED AS REQUIRED TO MATCH EXISTING. ANY INSULATION MISSING AT MISSING PANELS TO ALSO BE L REPLACED. PAWT ENTIRE CEILING. J t24.REMOVE EXISTING SKYLIGHT SASH 6 GLASS, (APPROX. 6'x3' W AREAI, INFILL w/ INSULATION, FRAMING AND CEILING PANELS W Z o AS REQUIRED TO MATCH EXISTING, PAINT. _ 25.ADJUST ALL EXISTING ELECTRICAL BOXES, DEVICES, ETC. L ' ?'AS REQUIRED TO ALLOW FOR NEW WALL FINISHES. O 26.PROVIDE NEW 2x4 W LAY -IN SUSPENDED CEILING SYSTEM. ELECTRICAL CONTRACTOR TO PROVIDE NEW 2.4 LAY -IN C7 LIGHT FIXTURES AS NECESSARY 8 REMOVE EXISTING. Z ���------��� M I6) 27.PROVIDE ADDITIONAL STUDS /SUPPORT WHERE EXISTING M O v STUDS. DO NOT EXTEND OR ATTACH TO BOTTOM PLATE. J VERIFY QUANTITY 6 CONDITIONS IN FIELD. 28. XISTING SUSPENDED HEATING UNIT TO BE REMOVED/ RELOCATED TO ADJACENT SPACES BY HVAC CONTRACTOR. m //� vU) 36 29,EX15T1NG SUSPENDED HEATING UNIT TO REMAIN. Q . 30. ELECTRICAL CONTRACTOR TO REMOVE EXISTING LIGHT, FIXTURES, AND cr- H 4 REPLACE w/ NEW AS REQUIRED. L 31. EXISTING PHONE /DATA EQUIPMENT, ETC, TO BE REMOVED z 6 AND RELOCATED AS DIRECTED BY OWNER. IF IT IS DETERMINED THAT ALL EQUIPMENT IS INACTIVE, REMOVE IN ITS ENTIRETY. - 32. AT EXISTING DOORS, PROVIDE NEW WEATHERSTRIP, SWEEPS, W ETC. AS REQUIRED. ADJUST STEEL PLATE AT SILL TO (r ELIMINATE BINDING. 33.PROVIDE NEW 518" DRYWALL OVER EXISTING STUDS/ SHEATHING, Z INISH b PAINT. 34. ROVIDE NEW LOW PROFILE SUSPENDED HEATING UNIT OR THIS SPACE BY HVAC CONTRACTOR. = n H. 0 -( 35.EPDXY PAINT EXISTING CONCRETE FLOOR. PREPARE FLOOR AS O REQUIRED BY MANUFACTURER RECOMMENDATIONS PRIOR to • TO PLACING NEW FINISH. M 36.EXISTING EXIT LIGHT TO REMAIN. N rn - 37. NEW EXIT LIGHT w/ DIRECTIONAL ARROW AS REQUIRED. JUNE 17, 2010 DRAWN BY SHEET A2 FLOOR PLAN JJOB M0938