Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Certificate of Occupancy
CITY HALL Inspection Services Div 215 Church Avenue City of Oshkosh 0 PO B 1130 OFIA Oshkosh WI 54903-1130 OJHKOJH ON THE WATER Approved: 06/28/2010 Reissued: 07/13/2010 MK1 LLC 905 Oregon St Oshkosh WI 54902 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby issued for the new 8 -Unit Apartment Building located at 820 -834 Nebraska St, Oshkosh WI as described in Building Permit #132885. This building shall be used as a Multifamily Apartment Building and is located in the C -3 Central Commercial Planned Development District. LIMITATIONS: Maximum number of persons: Per State Approved Plan Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land, or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. 0 e cej, Building Systems Inspector cc: Cumings Electric O'Neill Enterprises Building Permit Work Card Job Address 820 -834 NEBRASKA ST Permit Number 0132885 Create Date 9/2/2008 Owner MK -1 LLC Contractor OWNER Category 130 - New Multi- Family Plan E2- 2487 -0808 Occupany Permit Required Flood Plain Height Permit Class of Const: Use /Nature COMM/ 2 story 8 -unit apartment building. State Transaction ID #1505323, Site ID #734343. of Work NOTE: No work may commence above the foundation until engineering approval is granted. HVAC Contr Plumbing Contr Electric Contr Inspections: Date 1/22/2010 Type Rough In Inspector Nicole Krahn not approved REQUEST LINE / READY FOR A FINAL INSPECTION * * ** Brian states he set up an appointment with you for this Friday at 9am **** Draftstopping and firestopping were not completed for the plumbing penetrations. Date/Time requested: 1/21/2010 09:09 AM Notice Type: FC Ready Date/Time: 1/22/2010 09:00 AM Access: BRIAN WILL BE ON SITE Requested By: OWNER - Brian Burns Phone Number: (920) 216 -2149 Q Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Date 2/17/2010 Type Insulation Inspector Nicole Krahn approved w /cond. REQUEST LINE / READY FOR AN INSULATION INSPECTION NOTE: The garage ceilings were in the process of being blown in at the time of the inspection. Date/Time requested: 2/16/2010 10:03 AM Notice Type: Ready Date/Time: 2/16 /2010 10:03 AM Access: CALL BRIAN - HE WOULD LIKE TO BE PRESENT Requested By: OWNER - Brian Burns Phone Number: (920) 216 -2149 Q Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Date 2/17/2010 Type Re Rough In Inspector Nicole Krahn approved w /cond. The penetrations I could see were completed. Date/Time requested: 2/17/2010 12:33 PM Notice Type: Ready Date/Time: 2/17/2010 12:33 PM Access: Requested By: Phone Number: Q Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 6/28/2010 Type Final Inspector Nicole Krahn approved w /cond. Request line / For Occupancy The penetrations in the mechancial rooms needed additional firestopping applied where it appeared to have shrunk. Brian Burns was installing this when I left the job site. Date/Time requested: 6/25/2010 08:46 AM Notice Type: FC Ready Date/Time: 6/28/2010 . Access: Open Requested By: Brian Burns Phone Number: 920 - 216 -2149 Q Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Page 2 of 2 Building Permit Work Card Job Address 820 -834 NEBRASKA ST Permit Number 0132885 Create Date 9/2/2008 Owner MK -1 LLC Contractor OWNER Category 130 - New Multi-Family g ry a y Plan E2- 2487 -0808 Occupany Permit Required Flood Plain Height Permit Class of Const: Use /Nature COMM/ 2 story 8 -unit apartment building. State Transaction ID #1505323, Site ID #734343. of Work NOTE: No work may commence above the foundation until engineering approval is granted. HVAC Contr Plumbing Contr Electric Contr Inspections: Date 10/3/2008 Type Footings Inspector Nicole Krahn not approved Request line I have not received approval from the soil engineer for this site. Date/Time requested: 10/2/2008 03:16 PM Notice Type: Ready Date/Time: 10/3/2008 11:00 AM Access: Requested By: Del Rar - Laurie Phone Number: 920 - 731 -5464 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 10/6/2008 Type Footings Inspector Nicole Krahn not approved Request line q t e I have not received approval from the soil engineer for this site. Date/Time requested: 10/6/2008 09:32 AM Notice Type: Ready Date/Time: 10/6/2008 09:32 AM Access: Requested By: Laurie - Del Rar Phone Number: 920 - 731 -5464 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 10/8/2008 Type Foundation Backfill Inspector Nicole Krahn not approved Request line / Wall inspection I have not received approval from the soil engineer for this site, numerous requests have been made. Date/Time requested: 10/7/2008 09:22 AM Notice Type: Ready Date/Time: 10/7/2008 01:30 PM Access: Requested By: Laurie - Del Rar Phone Number: 920 - 731 -5464 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 10/10/2008 Type Foundation Backfill Inspector Nicole Krahn not approved Request line / Wall inspection I have not received approval from the soil engineer for this site, numerous requests have been made. Date/Time requested: 10/9/2008 08:49 AM Notice Type: Ready Date/Time: 10/9/2008 12:00 PM Access: Requested By: Laurie - Del Rar Phone Number: 920 - 731 -5464 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 1 of 2 Electric Permit Work Card Job Address 820 -834 NEBRASKA ST Permit Number 138292 Create Date 9/25/2009 Owner MK1 LLC Contractor CUMINGS ELECTRIC INC Service 0 New 0 Change° Temp • N/A Type 0 Overhead 0 Underground • N/A Volts 120/240 Circuits Luminaires 100 Amps 600 Switches 130 Receptacles 250 Value $23,000.00 Use /Nature Wiring for new 8 -unit apt building. * *debit acct of Work Inspections: Date 10/02/2009 Type Service Inspector Kevin Benner approved REQUEST LINE / READY FOR A SERVICE INSPECTION Faxed to WPS 10/2/9 Date/Time requested: 10 /01/2009 03:12 PM Notice Type: Ready Date/Time: 10/01/2009 03:12 PM Access: Requested by: CUMINGS ELECTRIC INC - Nancy Phone Number: (920) 231 -5946 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 10/02/2009 Type Rough In Inspector Kevin Benner not approved REQUEST LINE / READY FOR A ROUGH INSPECTION WITH OUT BATH FANS Gas pipe bonding, NEC 334.80 two or more NM cables through froming members in contact with insulation (found as many as seven). Faxed to the E.C. 10/2/9 Date/Time requested: 10/01/2009 03:12 PM Notice Type: Ready Date/Time: 10/01/2009 03:12 PM Access: Requested by: CUMINGS ELECTRIC INC - Nancy Phone Number: (920) 231 -5946 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 11/19/2009 Type Re Rough In Inspector Kevin Benner approved w /cond. REQUEST LINE / READY FOR A ROUGH INSPECTION FOR THE BATH FANS Gas piping was not bonded. Faxed to the E.C. 11/19/2009 Date/Time requested: 11/18/2009 12:21 PM Notice Type: Ready Date/Time: 11/18/2009 12:21 PM Access: Requested by: CUMINGS ELECTRIC INC - Jan Phone Number: (920) 231 -5946 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 06/25/2010 Type Final Inspector Kevin Benner approved w /cond. Request line \ A/C Split Systems: 2 polel5A CB in leiu of the 20A which is installed, boxes to be effectively closed. 6/25/10 Reviewed with the G.C.(Brian Burns) on site & called the E.C. (Dick W.) to discuss.The building inspector stated that she witnessed the corrections 6/30/10. Date/Time requested: 06/25/2010 07:32 AM Notice Type: Ready Date/Time: 06/25/2010 : Access: Open Requested by: CUMINGS ELECTRIC INC - Richard Wenz Phone Number: 231 -5946 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid HVAC Permit Work Card Job Address 820 -834 NEBRASKA ST Permit Number 134073 Create Date 11/17/2008 Owner MK1 LLC Contractor O'NEILL ENTERPRISES INC Fuel ✓ Gas I Oil I J Electric u Solar I Solid Value $50,000.00 System Q New ❑ Replace n Other ❑ Forced Air J Radiant ❑ Steam u A/C ❑ Vent ❑ Electric ❑ Hot Water U Suppl. ❑ Con. Burner Chimney Type 0 Chimney A 0 Chimney B 0 Direct Vent • Not Applicable Use /Nature COMM/ Hvac system for 8 -unit multifamily building. State Approved Plan Trans ID #1594268. of Work Inspections: Date 1/22/2010 Type Rough In Inspector Nicole Krahn approved Date/Time requested: 01/26/2010 12:19 PM Notice Type: Ready Date/Time: 01/22/2010 12:19 PM Access: Requested By: Phone Number: 0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 6/28/2010 Type Final Inspector Nicole Krahn approved Inspection was conducted with the final building inspection. Date/Time requested: 06/29/2010 08:23 AM Notice Type: Ready Date/Time: 06/29/2010 08:23 AM Access: Requested By: Phone Number: 0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Plumbing Permit Work Card Job Address 820 -834 NEBRASKA ST Permit Number 133066 Create Date 09/23/2008 Owner MK -1 LLC Contractor O'NEILL ENTERPRISES INC Category 440 - Industrial- Interior Plan Z3- 325 - 0808 -P Value $28,200.00 Bathtub 8 Clothes Wshr 4 Classrm Sink Surgeons Sink Roof Drain Deduct Meters Shower Lndry Tray 0 Exam Sink Sterilizer Soda Disp Wtr Sewer Mtrs Whirlpool Sump Pump F Prep Sink RPZ Valve Coffee Maker Wtr Usage Mtrs Lavatory 12 San Sump /Pump Flr/Wst Sink Bidet Site Drain Misc. 2 Toilet 12 Water Softner Hand Sink Urinal Wait. St. Fixtures Kit Sink 8 Standp Rec 4 Lab Sink Beer Tap Ice Chest Disposal Gar Drain Plaster Sink Dip Well Comm Ice Maker Dishwasher 4 Local Waste Sculry Sink Drink Ftn Int Grease Trap Floor Drain 3 Bar Sink Sery Sink Wash Ftn Ext Grease Trap Hose Bibb Breakrm Sink Shamp Sink Catch Basin Eye Wash Statn Water Heater 5 silcock Use /Nature Interior plumbing for new 8 unit townhouse. of Work Size Material Type # Conn.Type Sanitary Sewer Storm Sewer I Water Service I Inspections for Work Card 101042 Date 11/3/2008 Type Underground Inspector Paul Wolf approved Date/Time requested: 11/3/2008 07:23 AM Notice Type: Telephone Number: Access: Ready Date/Time: 11/3/2008 07:23 AM Requested By: O'NEILL ENTERPRISES INC O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 7/21/2009 Type Rough In Inspector Paul Wolf approved Date/Time requested: 7/21/2009 07:40 AM Notice Type: Telephone Number: Access: Ready Date/Time: 7/21/2009 07:40 AM Requested By: O'NEILL ENTERPRISES INC Q Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 6/24/2010 Type Final Inspector Paul Wolf approved E -mail request Date/Time requested: 6/24/2010 10:00 AM Notice Type: Telephone Number: 230 -2007 Access: Open Ready Date/Time: 6/24/2010 : Requested By: O'NEILL ENTERPRISES INC O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid H.V4C, COMPLIANC STATEMENT S8D -9720 ¶PT ` : lb* bm .b.inPN� b9rt a ye .. wCh.WJ, u►9eef. HVAC del i& of eiectncai ? o$srtin conu�on o1 Purl s wri bta Wipe ' an as 50 000 wttic beet or yreaW and bars (Comir 541 61•5f). Fe tp subltat this tatm may Mh pens* es as specdIed in Comm 50 26ICamm 6123 brai ordinsrt .. Tttia kxm must be submitted pmt to the p1@11 approval expir on dale or a other sut mmW may 1xa rruwned: ,.1 Ini*st1ons Priorlio► t}* mnlibal occupancy of ttew bl, ldwigs or additions and the final occupancy of } � + oomfrmted and sned fTn to: .'h# mum b kpet1on ofllce try to the plan approval Ioer for ag.ncy address annd • y and di1 .10541$ Ranch Road Nayward. *1.54843 54843 NOW $f tyre twAmwa$ dons by the municipality the cotnp1iance statement goes only to titre mama p ti building ;A ii not naedsd by Stt ety & BuMd1nQs, tlwe tMed �x $ nICy law, s 15.04 1 Xm►I L PROJECT VV QW7 4: P1m M in the fd$cwirg 00 information front your plan proval btler- Tta gibrt, ID N4a blp 15O323 PIoj*ct Name Minas Kirnba$ Tawnhomes 5 Nnibsr 734343 gyp, :f�aa r C' "7^1ryr ttla s� l $ , r PU RPOSE ST (Ched k Box B. C , M i to snd cal e pMM se an other �� ► pIiing Ob4ocI ID 1170014 "` 0 HVAC Ob ect ID s n C m 1M bM eI #M bawd an of IS cb ry ion. t ld�n of endfa I NIIC " b0Sfl,mod w $ili 1 �nancsi aw aipioved ii and I'w _ w s OMB 404160 10. i for f ptM�np�d c�nr of mqur a*. smokt dal GrsE) dM d , 12. M CpesQlpq/ i i Mllp DYn a �7v� t +ral1lpw11�1 k.r..4 d ear on bade iow O"J") and ww=% rnurnii �' sMAllgll ,M ° d ha$ di, Ii* � Ohl. WWOd 400VL class 13 KVAC fl EMS (may} a 1 - w�11rt�C Mr<Mtrtlrg in�t 1as1 IMyAMpili srld iii 2 A f GO�ti!li0N10l frV1Y� pYn approval snd +Ffrian _ tlMrliOl 1yr�M M �. ' ,lhMew y tl aglwpw npt l accw.nc • ) Cl 3 Pst IFiMM `IAItMad awn From P o t w ar a r+oo�e 10 rwd�wrrw aw•� saws atis a aN t 3. t .; .. SIG l4TltR FOR. �. h a eff 0 t ,ismfs R 4WQ '*U • y ( tt NNW 1x r a at ., tirew�.bpt �uct�Yl�p►� a Jun 28 10 04:28p Doug 9209971595 p 1 BUILDINGS, HVAC, COMPLIANCE STATEMENT SBD-9720 This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) observing construction of projects within buildings with total areas 50,000 cubic feet or greater and bleachers (Comm 6t40). Failure to submit this form may result in penalties as specified in Comm 61.23 and/or local ordinances. This form must be submitted prior to the plan approval expiration date or another submittal may be required. General Instructions: Prior to the initial occupancy of new buildings or additions and the final occupancy of altered existing buildings, submit this completed and signed form to: • The municipal building inspection office (refer to the plan approval letter for agency address) and • Safety and Buildings, 10541N Ranch Road Hayward, WI. 54843 Note: If the review was done by the municipality, the compliance statement goes only to the municipal building inspector. A copy is not needed by Safety & Buildings. Personal information you provide may be used for secondary purposes [Privacy Law s. 15.04 (1)(mrj 1. PROJECT INFORPAAT1ON: Please fill in the following with i rmation frorn„ygur plan approval letter. Transaction ID Number /C 9 4- Project Name car/ Ocr .42/'‘ Site Number 343 Site location (number & street) 0 Village 0 Town of .).5 H County of Z(.1 2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or D to indicate purpose and complete any other applicable boxes and information. Attach additional pages if necessary.) Check those which apply: 0 Building Object ID # er Object ID # /Z-d 2.. 24L_ 0 Lighting Object ID # 0 Partial Completion Description of Portion Completed A) a7r1i of Substantial Compliance To the best of my knowledge, belief, and based an onsite obsenration construction of the tcllowing building andfor HVAC items applicable tc this project have been completed in substantial compliance MTh the approved plans and specitimttions. 0 BUILDII4GiLIGHTING ITEMS 1. Structural system including sJernittal and erection of all building components 10. Exterior lighting 8 control requirements (Misses, precast meta) building, etc.) 11. Interior lighting & control requirements 2. Fire protection systems (sprinklers, alarms. smoke detedors) esigned. installed, 12. All conditions of lighting plan approval and tested (inciudIng forward Now on back flow devices) oy appropriately and applicable variances registered professionals 3. Shaft and stairway enclosure 4. Exits Including exit and directional lights 5. Fire-resistive miristruction, enclosure of hazards, fire walls, labeled doors. class 0 FIVAC ITEMS of construction, flre stoppea penetrations 6. Sanitation system (toilets sinks, drinking facilities) 1. HVAC system including final test 7. Barrier-free including Comrn 18 elevators and lifts 2. All conditions of HVAC plan approval and 8. Energy envelope requirements applicable variances 9. NI conditions of building plan approval and applicable variances The following items are not in compliance and must be addressed: 3) 0 Statement of Noncompliance Duo to the following listed violations, this project is nCt ready for occupancy: C) 0 Supervising Professional Withdrawn From Project (use A or B aoove to indicate project status as Of this date.) D) 0 Project Abandoned 3. SUPERVISING Pf3PFESSIONAL SIGNATURE FOR: 0 Blinding aVAC 0 Lightnc G yte Name (please print or type Phone number F — 4/? Customer ID flt I Signature (-•"---')." 8130-9720 (R 07,20081 SBD-9720 (R.02;2004) Safety and Buildings 2331 SAN LUIS PL STE 150 commerce.Wi.gov GREEN BAY WI 54304 W Contact Through Relay tsconsin www.commerce.wi:gov /sb/ epartment of Commerce OCT 2 g 20�$ www.wisconsin.gov Jim Doyle, Governor - Richard J. Lelnenkugel, Secretary October 24, 2008 CUST ID No. 682911 ATTN: Buildings & Structures Building Inspector DOUGLAS L GEYER BUILDING INSPECTION HVAC DESIGN SOLUTIONS LLC CITY OF OSHKOSH W7094 W SPENCER RD POB 1130 APPLETON WI 54914 OSHKOSH WI 54902 (Please forward a copy of this letter to the fire department conducting inspections of this project.) CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 02/22/2010 Identification Numbers Transaction ID No. 1594268 SITE: Site ID No. 734343 Miles Kimball Townhomes Please refer to both identification numbers, West 8TH and 9TH Ave above, in all correspondence with the agency. City of Oshkosh FOR: Facility: 687716 MILES KIMBALL TOWNHOMES BLDG 2 WEST 8TH AND 9TH AVE Object Type: HVAC ICC System Regulated Object ID No.: 1202839 Code Applies Date: 09/30/08 9,000 sq ft Area Heated Facility: 687717 MILES KIMBALL TOWNHOMES BLDG 3 WEST 8TH AND 9TH AVE Object Type: HVAC ICC System Regulated Object ID No.: 1202840 Code Applies Date: 09/30/08 9,000 sq ft Area Heated Facility: 687718 MILES KIMBALL TOWNHOMES BLDG 4 WEST 8TH AND 9TH AVE Object Type: HVAC ICC System Regulated Object ID No.: 1202841 Code Applies Date: 09/30/08 9,000 sq ft Area Heated Facility: 687719 MILES KIMBALL TOWNHOMES BLDG 1 WEST 8TH AND 9TH AVE Object Type: HVAC ICC System Regulated Object ID No.: 1202842 Code Applies Date: 09/30/08 9,000 sq ft Area Heated The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. Only those object types listed above have been approved; other submittals such as plumbing and those listed below under Also Submit, may be required. The following conditions shall be met during construction or installation and prior to occupancy or use: Submit • Comm 61.30(3) -This review does not include approval for the installation of Boilers & Pressure Vessels indicated on this plan. The installation of any Boiler or Pressure Vessel shall be registered with the Department by the installer before the system is placed in operation as prescribed by COMM 41.41. Registration shall be in writing on Form SBD -6314. The required department forms may be obtained from the Division of Safety & Buildings, Material Orders, P.O. Box 2509, Madison, WI 53701 -2509, telephone 608/266 -3151, 608/264 -8777 (TTY), or at the Safety & Buildings web site at http://www.commerce.state.wi.us/SB/SB- DivForms.html #Boilers Contact the Refrigeration/Boiler Safety Inspector listed at the end of this letter with any questions. DOUGLAS L GEYER Page 2 10/24/2008 • If this is a dual use water heater for space heating and potable water then it does not need to be registered as a boiler. The plumbing designer will need to provide additional information in the plumbing submittal. Water heaters shall be tested in accordance with ANSI Z 21.10.1 and ANSI Z 21.10.3 and shall be installed in accordance with the manufacturer's installation instructions. Water heaters utilized for both potable water heating and space- heating applications shall be sized to prevent the space- heating load from diminishing the required water - heating capacity. • Comm 61.36(1)(a) & (b) This approval will expire 2 years after the date of approval of the building plans if the building shell is not closed in within those 2 years. Also, this approval will expire 3 years after the date of building plan approval if the work covered by this approval is not completed and the building ready for occupancy within those 3 years. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full planets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction /installation/operation. Any local requirements shall be complied with. This plan has not been generally reviewed for compliance with fire code requirements, including those for fire lanes and fire protection water supply, so contact the local fire department for further information. If this construction project will disturb one or more acres of land, an Erosion Control Notice of Intent (NOI) shall be filed with the department 7 days prior to any earth disturbing activities. You will need to either file the NOI and an erosion control plan summary on -line at www.commerce.wi.gov /sb or submit a completed NOI form and either a plan summary or complete plan to us, with additional fees, or to the certified municipality. In granting this approval, the Division of Safety & Buildings reserves the right to require changes or additions, should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. The Division does not take responsibility for the design or construction of the reviewed items. Per s. Comm 61.40(4), projects for buildings of over 50,000 cubic feet total volume shall have supervising professionals who file compliance statements with this agency and the local code officials prior to occupancy of the project. The compliance statement form is available on our website, www.commerce.wi.gov /sb under forms for commercial buildings. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerel , Fee Required $ 710.00 This Amount Will Be Invoiced. l N When You Receive That Invoice, John D VanBuecken, P.E. Please Include a Copy With Your Building Plan Reviewer , Integrated Services Pavment Submittal. (920)492 -7727 , Monday - Friday 8:00 am - 4:30 pm WiSMART code: 7648 john.vanbuecken@wisconsin.gov cc: John R Anderson, State Building Inspector, (715) 823 -2014 , Monday,7:45A.M.- 4:30P.M. Brian Burns, Burns Development Jon P Wolf, Boiler Inspector, (920) 723 -0032 DEPARTMENT OF PUBLIC WORKS 215 Church Avenue P.O. Box 1130 Oshkosh, Wisconsin 54903 -1130 Ph. (920) 236 -5065 OJ1�KOJH Fax (920) 236 -5068 ON THE WATER November 12, 2008 Patrick Kuehl, P.E. Robert E. Lee & Associates, Inc. 4664 Golden Pond Park Court Hobart, WI 54155 RE: Drainage, Grading and Erosion Control Plan Approval (851 South Main Street and 800 -874 Nebraska Street) Dear Mr. Kuehl: , This letter is to inform you that the Drainage Grading and Erosion Control Plan (signed and sealed November 10, 2008), which you submitted on behalf of Burns Development, has been reviewed and approved. If you have any further questions regarding this project, please do not hesitate to contact us. Sincerely, James Rabe, P.E. Civil Engineer II cc: David Patek, P.E., Director of Public Works Steve Gohde, P.E., Assistant Director of Public Works Laura Gray, Civil Engineer I Allyn Dannhoff, Director of Inspection Services (via email) Brian Noe, Building Systems Inspector (via email) Todd Muehrer, Zoning Administrator / Associate Planner (via email) File • RECE NOV 12 2008 ROBERT E. LEE & ASSOC; tNO. I:\Engineering\SWMP - Non - Residential \851 S. Main St - Burns Page 1 of 1 Development\Drainage Grading and Erosion Control Plan Approval.doc REPORT OF DENSITY TEST OF COMPACTED FILL 1060 Breezewood Lane, Suite 102 ` nifr Neenah, ph 920 - 8888 WI 6 --140140 6 Engineering Resources, Testing Solutions fax 920 - 886 -1409 www.rvtcorp.com Project: MILES KIMBALL TOWNHOUSE Copies: OSHKOSH, WISCONSIN 14A Client: Mr. Brian Burns , _l Y Burns Development 905 Oregon St. Oshkosh, WI 54920 (It,W —tP)4 Date: October 2, 2008 RVT File No: N08 -349 . GENERAL: Date of Tests: 10/1/08 Scope of Work: Conduct field density tests on an "as requested" basis in the general area indicated by Rabe personnel. Perform laboratory analysis as necessary and notify Mr. Brian Burns with Burns Development of failing test results. Field Technician: M Gabriel Test Locations Selected By: River Valley Testing Corp. GENERAL LOCATION: Townhouse #4 (Depths are referenced to bottom of floor.L Test Elevation Proctor Number Test Location or Depth Number 16 20' S and 10' W of Northeast Corner -0' 1 17 Retest #16 -0' 1 18 15' S and 50' W of Northeast Corner -0' 1 19 10' S and 40' E of Northwest Corner -0' 1 20 30' S and 35' E of Northwest Corner -0' 1 FIELD DENSITY: Density Test Method: ASTM D6938, Laboratory Test Method: ASTM D1557, M ethod C Test Dry Moisture Gravel Max Lab Optimum Field Specified Number Density Content Content Density Moisture Compaction Compaction Comments* 16 127 4.0 145.3 7.1 88 95 2, L 17 231 4.2 145.3 7.1 90 95 2, 4, L 18 131 4.5 145.3 7.1 90 95 2, L 19 139 5.3 145.3 7.1 96 95 1, L 20 142 6.6 145.3 7.1 98 95 1, L REMARKS: - Test results are valid only at the indicated location and elevation. No guarantee is made as to the adequacy of compaction at other locations and elevations. - Densities are in Ibs per ft - Water Content is percent of Dry Sample *1. Test results comply with Specifications N — Native Soil 2. Recompaction required C — Clay Fill 3. Recompaction required after adjusting fill moisture content S — Sand Fill 4. Retest is after recompaction L — Crushed Limestone Fill 5. Moisture Content meets /does not meet specification 6. Maximum lab density adjusted for varying gravel content Respectfully Submitted, River Valey Testing Corp 2 ,-2-1 l-1 ".-*'• 335 (4/03) Geotechnical • Construction Materials Testing • Environmental REPORT OF DENSITY TEST OF COMPACTED FILL 1060 Breezewood Lane, Suite 102 . Neenah, 54956 I= ma law ph 920 - 8888 6 -140-1406 Engineering Resources, Testing Solutions fax 920-886-1409 www.rvtcorp.com Project: MILES KIMBALL TOWNHOUSE Copies: OSHKOSH, WISCONSIN Client: Mr. Brian Burns Burns Development 905 Oregon St. Oshkosh, WI 54920 Date: October 2, 2008 RVT File No: N08 -349 GENERAL: Date of Tests: 10/1/08 Scope of Work: Conduct field density tests on an "as requested" basis in the general area indicated by Rabe personnel. Perform laboratory analysis as necessary and notify Mr. Brian Burns with Burns Development of failing test results. Field Technician: M Gabriel Test Locations Selected By: River Valley Testing Corp. GENERAL LOCATION: Townhouse #4 (Depths are referenced to bottom of floor.L Test Elevation Proctor Number Test Location or Depth Number 21 Retest #17 -0' 1 22 Retest #18 -0' 1 23 Retest #21 -0' 1 FIELD DENSITY: Density Test Method: ASTM D6938, Laboratory Test Method: ASTM D1557, Method C Test Dry Moisture Gravel Max Lab Optimum Field Specified Number Density Content Content Density Moisture Compaction Compaction Comments* 21 135 7.8 145.3 7.1 93 95 2, 4, L 22 138 5.4 145.3 7.1 95 95 1, 4, L 23 140 8.8 145.3 7.1 96 95 1, 4, L REMARKS: - Test results are valid only at the indicated location and elevation. No guarantee is made as to the adequacy of compaction at other locations and elevations. Densities are in Ibs per ft - Water Content is percent of Dry Sample '1. Test results comply with Specifications N — Native Soil 2. Recompaction required C — Clay Fill 3. Recompaction required after adjusting fill moisture content S — Sand Fill 4. Retest is after recompaction L — Crushed Limestone Fill 5. Moisture Content meets /does not meet specification 6. Maximum lab density adjusted for varying gravel content Respectfully Submitted, River Valley Testing Co . 335 (4/03) Geotechnical • Construction Materials Testing • Environmental O'NEILL ENTERPRISES INC. PLUMBING & HEATING CONTRACTORS 522 W. 6T" AVENUE OSHKOSH WI. 54902 920- 230 -2007 - -- Fax 920 - 230 -2008 Firestop Submittal Project: Burns Development Miles Kimball Townhomes Date: 02 -09 -09 System No. C -AJ -2351 • F Rating — 2 Hr T Rating — 0 and 1 Hr (See Table) A p 3A, U IA. Floor or Wall Assembly Min 4 -1/2 in. thick reinforced light weight or normal weight (100 -150 pcf) concrete. Wall • may also be constructed of any UL Classified Concrete t fl 3A) i s Blocks *. Floor may also be constructed of any 6 in. thick UL • '' s i.__. ..� Classified hollow core Precast Concrete Units. Max diam 1 8 of opening is 4 or 5 in. (see table below). 1 B 3B See Concrete Blocks (CAZT) and Precast Concrete Units A (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 1B. Metallic Sleeve (optional) Nom 5 in. (or smaller - see ~ table below), Schedule 10 (or heavier) steel pipe sleeve, cast SECTION 'A —A' or grouted into floor or wall assembly, flush with floor or wall surfaces. 2. Through Penetrants One nonmetallic pipe to be installed either concentrically or eccentrically within the firestop system. The annular space shall be as specified in the table below. Pipe to be rigidly supported on both sides of floor or wall assembly. The following type and sizes of nonmetallic pipes may be used (see table below): A. Acrylonitrile Butadiene Styrene (ABS) Pipe Nom 3 in. diam (or smaller) Schedule 40, cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Polyvinyl Chloride (PVC) Pipe Nom 3 in. diam (or smaller) Schedule 40, cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. C. Rigid Nonmetallic Conduit (RNC)+ Nom 3 in. diam (or smaller) Schedule 40, PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). D. Chlorinated Polyvinyl Chloride (CPVC) Pipe Nom 2 in. diam (or smaller) SDR17 CPVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. 3. Firestop System The firestop system shall consist of the following: A. Fill, Void, or Cavity Materials* - Wrap Strip - Nom 1/4 in. thick intumescent material faced on both sides with a plastic film, supplied in 1 -1/2 in. wide strips. One or two pieces of wrap strips shall be used. The first piece installed around the outer circumference of the through penetrant with ends butted and held in place with masking tape. The second piece, where required, is either wrapped over the first piece (layered), or wrapped around the penetrant, stacked immediately above the first piece. The ends of the second piece shall be butted and held in place with masking tape, and offset from the taped joint of first piece. The mode of application of the second piece is dependant on the annular space between penetrant and periphery of opening. See table below. The wrap strips shall be recessed from the top or bottom surface of the concrete floor by an amount equivalent to the thickness of sealant required (see table below). In walls, the wrap strips shall be installed on one surface of the wall, such that the exposed edges of the wrap strips are recessed by an amount equivalent to the thickness of sealant required (see table below). W R GRACE & CO - CONN CONSTRUCTION PRODUCTS DIV — FlameSafe® Wrap Strip B. Fill, Void, or Cavity Materials* - Sealant Fill material applied within the annulus, flush with top or bottom surface of floor or one surface of wall, as shown in table below. When floor is constructed of hollow -core precast units, sealant to be installed on the bottom side of the floor. Max Max Pipe Annular No. of Opening /Sleeve Pipe Diam. Space Wrap Wrap Strip Min Sealant T- Rating Diam In Type In In Strip Installation Thknsln. Hr 4 ABS 3 1/4 to 5/16 1 2. Stacked 1/4 I 0 5 ABS 3 1/2 to 1 -3/16 2 Layered 1/2 0 4 PVC, 2 1/4 to 1 -5/8 1 — 1/2 1 RNC 4 PVC, 3 1/4 to 5/16 2 Stacked 1/2 0 RNC 3 PVC, 2 1/4 to 3/8 I 1/2 1 RNC W R GRACE & CO - CONN CONSTRUCTION PRODUCTS DIV — FlameSafe® FS 1900 *Bearing the UL Classification Mark +Bearing the UL Listing Mark. This writeup may not This material was extracted by contain the latest revision Grace Construction Products from the UL Fire Resistance Directory System No. F -C -2042 November 04, 2002 F Ratings —1 and 2 Hr (See Item 3) T Ratings - 0 and 1 Hr (See Item 3) { it --- � ,gag 1. Floor Ceiling Assembly — The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor- Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in Design No. L505, L511 or L536 in the UL Fire Resistance Directory. The general construction features of the floor - ceiling assembly are summarized below: A. Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor - Ceiling Design. Max diam of floor opening is 4 in. B. Wood Joists — For I hr fire -rated floor - ceiling assemblies, nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire -rated floor- ceiling assemblies, nom 2 by 10 in. lumber joists spaced 16 in. OC with nom 1 by 3 in. lumber bridging and with ends firestopped. C. Furring Channels — In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of gypsum board (Item ID). Furring channels spaced max 24 in. OC. In 1 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor- Ceiling Design. Furring channels spaced max 24 in. OC. D. Gypsum Board* — Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor- Ceiling Design. First layer of gypsum board nailed to wood joists. Second layer of gypsum board screw- attached to furring channels. Max diam of ceiling opening is 4 in. 2. Through Penetrants One nonmetallic pipe or conduit to be installed concentrically or eccentrically within the firestop system. Annular space between pipe or conduit and periphery of opening is dependent upon the hourly fire rating of the floor - ceiling assembly, and type of fill material in which it is installed as shown in Item 3. Pipe or conduit to be rigidly supported on both sides of the floor- ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 2 in. diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ - Nom 2 in. diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 2 in. diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. 3. Fill, Void or Cavity Material* — Sealant — In 2 hr fire -rated assemblies, min 3/4 in. thickness of sealant applied within annular space, flush with top surface of floor. Min 1 -1/4 or 5/8 in. thickness of sealant as indicated in the table below, applied within the annular space, flush with bottom surface of gypsum board ceiling. Additional fill material to be installed such that a min 1/4 in. crown is formed around the penetrating item on both sides of floor- ceiling assembly. In 1 hr fire - rated assemblies, min 3/4 in. thickness of sealant applied within annular space, flush with top surface of floor. Min 5/8 in. thickness of sealant applied within the annular space, flush with bottom surface of gypsum board ceiling. Additional fill material to be installed such that a min 1/4 in. crown is formed around the penetrating item on both sides of floor - ceiling assembly. The F and T Ratings of the firestop system are dependent upon the hourly fire rating of the floor- ceiling assembly, min and max annular space within the firestop system and . e and thickness of fill material used within the firesto • stem as shown in the table below: Min Thickness Min, Max of Sealant Rating of Type of Annular Within Ceiling, Assembly, Hr Sealant Space, in in F Rating, Hr T Rating, Hr 1 2 FS 1900 1/2, 1 -1/8 1 -1/4 2 1 0 2 FS 900+ 1/2, 5/8 i 5/8 2 ) 0 1 FS 900+ 1/2, 5/8 { 5/8 -11 1 ( 1 W R GRACE & CO - CONN CONSTRUCTION PRODUCTS DIV — FS 1900 Sealant or FS 900+ Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking This writeup may not This material was extracted by contain the latest revision Grace Construction Products XHEZ.F -C -2042 - Through - penetration Firestop Systems / ? Page 1 of 4 ONLINE CERTIFICATIONS DIRECTORY XH EZ. F -C -2042 Through - penetration Firestop Systems Page Bottom Design /System /Construction /Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through - penetration Firestop Systems See General Information for Through - penetration Firestop Systems System No. F -C -2042 January 07, 2009 F Ratings — 1 and 2 Hr (See Item 4) T Ratings - 0 and 1 Hr (See Item 4) L Rating at Ambient - Less than 1 CFM /sq ft L Rating at 400° F - Less than 1 CFM /sq ft http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME/showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2042 - Through - penetration Firestop Systems Page 2 of 4 1 Ei lug w I D 1. Floor Ceiling Assembly — The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor - Ceiling Designs in the UL Fire Resistance Directory. The 2 hr fire -rated wood joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in Design No. L505, L511 or L536 in the UL Fire Resistance Directory. The general construction features of the floor - ceiling assembly are summarized below: A. Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor - Ceiling Design. Diam of floor opening to be 1 in. to 1 -5/8 in. (25 to 41 mm) larger than outside diam of through penetrant. Max diam of floor opening is 4 in. (102 mm). B. Wood Joists — For 1 hr fire -rated floor - ceiling assemblies, nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. For 2 hr fire - rated floor - ceiling assemblies, nom 2 by 10 in. (51 by 254 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. C. Furring Channels — In 2 hr fire -rated assemblies, resilient galv steel furring installed perpendicular to wood joists between first and second layers of gypsum board (Item 1D). Furring channels spaced max 24 in. (610 mm) OC. In 1 hr fire - rated assemblies, resilient galv steel furring installed perpendicular to wood joists between gypsum board and wood joists as specified in the individual Floor - Ceiling Design. Furring channels spaced max 24 in. (610 mm) OC. D. Gypsum Board* — Nom 4 ft (1.2 m) wide by 5/8 in. (16 mm) thick as specified in the individual Floor - Ceiling Design. First layer of gypsum board nailed to wood joists. Second layer of gypsum board screw - attached to furring channels. Diam of ceiling opening to be 1 in. to 1 -5/8 in. (25 to 41 mm) larger than outside diam of through penetrant. Max diam of ceiling opening is 4 in. (102 mm). http: / /database.ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 • XHEZ.F -C -2042 - Through - penetration Firestop Systems Page 3 of 4 2. Chase Wall — (Not Shown, Optional) — The through penetrants (Item 3) may be routed through a 1 or 2 hr fire -rated single, double or staggered wood stud /gypsum board chase wall having a fire rating consistent with that of the floor - ceiling assembly. The chase wall shall be constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Nom 2 by 6 in. (51 by 152 mm) lumber or double nom 2 by 4 in. (51 by 102 mm) lumber studs. B. Sole Plate — Nom 2 by 6 in. (51 by 152 mm) lumber or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Diam of opening in sole plate to be 1 in. to 1- 5/8 in. (25 to 41 mm) larger than outside diam of through penetrant. Max diam of opening is 4 in. (102 mm). C. Top Plate — The double top plate shall consist of two nom 2 by 6 in. (51 by 152 mm) lumber plates or two sets of nom 2 by 4 in. (51 by 102 mm) lumber plates tightly butted. Diam of opening in top plate to be 1 in. to 1 -5/8 in. (25 to 41 mm) larger than outside diam of through penetrant. Max diam of opening is 4 in. (102 mm). D. Gypsum Board* — Thickness, type, number or layers and fasteners shall be as specified in individual Wall and Partition Designs. 3. Through Penetrants — One nonmetallic pipe or conduit to be installed concentrically or eccentrically within the firestop system. Annular space between pipe or conduit and periphery of opening is dependent upon the hourly fire rating of the floor - ceiling assembly, and type of fill material in which it is installed as shown in Item 4. Pipe or conduit to be rigidly supported on both sides of the floor - ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ — Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 2 in. (51 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Electrical Nonmetallic Tubing (ENT +) — Nom 1 in. (25 mm) diam (or smaller) corrugated -wall electrical nonmetallic tubing (ENT) constructed of polyvinyl chloride (PVC) and installed in accordance with the National Electrical Code (NFPA No. 70). See Electrical Nonmetallic Tubing (FKHU) category in the Electrical Construction Materials Directory for names of manufacturers. 4. Fill, Void or Cavity Material* — Sealant — In 2 hr fire -rated assemblies, min 3/4 in. (19 mm) thickness of sealant applied within annular space, flush with top surface of floor or chase wall sole plate. Min 1 -1/4 or 5/8 in. (32 or 16 mm) thickness of sealant as indicated in the table below, applied within the annular space, flush with bottom surface of gypsum board ceiling or chase wall top plate. Additional fill material to be installed such that a min 1/4 in. (6 mm) crown is formed around the penetrating item on both sides of floor - ceiling assembly. In 1 hr fire -rated assemblies, min 3/4 in. (19 mm) thickness of sealant applied within annular space, flush with top surface of floor. Min 5/8 in. (16 mm) thickness of sealant applied within the annular space, flush with bottom surface of gypsum board ceiling . Additional fill material to be installed such that a min 1/4 in. (6 mm) crown is formed around the penetrating item on both sides of floor - ceiling assembly. The F and T Ratings of the firestop system are dependent upon the hourly fire rating of the floor - ceiling assembly, min and max annular space within the firestop system and type and thickness of fill material used within the firestop system as shown in the table below: Min Thickness Min, Max of Sealant Annular Within Rating of Type of Space, in. Ceiling, in. Assembly, Hr Sealant (mm) (mm) F Rating, Hr T Rating, Hr http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2042 - Through- penetration Firestop Systems Page 4 of 4 2 FS 1900 1/2, 1 -1/8 (13, 38) 1 -1/4 (32) 2 0 1 FS 1900 1/2, 1 -1/8 (13, 38) 5/8 (16) 1 0 2 FS 900+ 1/2, 5/8 (13, 16) 5/8 (16) 2 0 1 FS 900+ 1/2, 5/8 (13, 16) 5/8 (16) 1 1 W R GRACE & CO - CONN — FS 1900 Sealant or FS 900+ Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking Last Updated on 2009 -01 -07 Questions? Notice of Disclaimer Page Top Copyright n 2009 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc.®" An independent organization working for a safer world with integrity, precision and knowledge. 111 /111/ http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 System No. F -C -2082 • July 17, 2003 F Rating —1 Hr T Ratings — 3/4 and 1 Hr (See Item 4) - 1;1 =4 K. ss ti I A L A =•., r" -%; , • . J i ! ,..gTtoiy CONFIGURATION A CONFIGURATION 13 1. Floor - Ceiling Assembly — The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor - Ceiling Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor - Ceiling Design. Max diam of floor opening is 5 in. _ B. Wood Joists — Nom 2 by 10 in. lumber joists spaced 16 in. OC with nom 1 by 3 in. lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members * with bridging as required with ends firestopped. C. Furring Channels — (Not Shown) — Resilient galv steel furring installed perpendicular to wood joists (Item 1B) between gypsum board (Item ID) and wood joists as required in the individual Floor- Ceiling Design. D. Gypsum Board* —Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor - Ceiling Design. Gypsum board secured to wood joists or furring channels as specified in the individual Floor - Ceiling Design. 2. Chase Wall — The through penetrant (Item 3) shall be routed through a 1 hr fire -rated single, double or staggered wood stud/gypsum board chase wall constructed of the materials and in the manner specified in U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall have the following construction details. CHASE WALL CONFIGURATION A A. Studs — Nom 2 by 6 in. or double nom 2 by 4 in. lumber studs. B. Sole Plate — Nom 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 5 in. C. Top Plate — The double top plate shall consist of two nom 2 by 6 in. or two sets of parallel 2 by 4 in. lumber plates tightly butted. Max diam of opening is 5 in. D. Gypsum Board* — Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. CHASE WALL CONFIGURATION B A. Studs — Nom 2 by 4 in., 2 by 6 in. or double 2 by 4 in. lumber studs. Nom 2 by 4 studs are allowed for a max 3 in. diameter penetrant. B. Sole Plate — Nom 2 by 4 in., 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Plate may be discontinuous over opening, terminating at both sides of periphery of opening. For openings 3 in. diam or less, plate may be continuous with opening cut in plate. Max diam of opening or max length of discontinuity is 4 in. C. Top Plate The single top plate shall consist of nom 2 by 4 in., 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Plate may be discontinuous over opening, terminating at both sides of periphery of opening. For openings 3 in. diam or less, plate may be continuous with opening cut in plate. Max diam of opening or max length of discontinuity is 4 in. D. Steel Plate For a nom 3 in. diameter penetrant through 2 by 4 in. lumber plates, two sides of noncontinuous lumber plates shall be connected with nom 16 gauge (or heavier) 1 -1/2 in. wide steel plate. Steel plates to be sized in length to overlap a min of 4 in. onto each side of the noncontinuous plates and secured with a min of two 'A in. long (or longer) No. 8 (or larger) wood screws on each side of each plate. E. Gypsum Board* — Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. 3. Through Penetrants — One nonmetallic pipe or conduit or tubing to be installed approximately midway between wood joists and either concentrically or eccentrically within the firestop system. Diam of openings hole -sawed through flooring system and through top plate of chase wall assembly to be max 1 in. larger than outside diam of through penetrant. The annular space within the firestop system is dependent upon the nom diam of the through penetrant. If the nom diem of the through penetrant is 3 in. or less, the annular space within the firestop system shall be a min 0 in. (point contact) to a max 1 in. If the nom diam of the through penetrant is greater than 3 in., the annular space within the firestop system shall be a min 0 in. (point contact) to a max 3/8 in. The pipe, conduit or tubing may be installed with continuous point contact. Pipe, conduit or tubing to be rigidly supported on both sides of the floor- ceiling assembly. The following types and sizes of nonmetallic pipes, conduits or tubing may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 4 in. diam Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Rigid Nonmetallic Conduit+ — Nom 4 in. diam Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code (NFPA No. 70). C. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 4 in. diam SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. D. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 4 in. diam Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. E. Cross Linked Polyethylene (PEX) Tubing — Nom 1-1/2 in. diam (or smaller) SDR 9 cross linked polyethylene (PEX) tubing for use in closed (process or supply) piping systems. 4. Fill, Void or Cavity Material* — Sealant — Min 3/4 in. thickness of fill material applied within annulus, flush with top surface of floor. Min 5/8 in thickness of fill material applied within annulus on lower top plate of chase wall assembly. Additional fill material to be installed such that a min 1/4 in. crown is formed around the through penetrant on the top surface of the floor and bottom surface of the lower plate of chase wall assembly. If the through penetrant is installed with continuous point contact, a min %: in. thick bead of fill material applied around outer circumference of through penetrant on top surface of floor and bottom surface of lower top plate. The T Rating of the firestop system is dependent upon the type of sealant used within the firestop system as shown in the table below: T •e of Fill Material T Ratin., Hr FS 900+ Sealant • FS 1900, FS1901, FS1905 and FSl929 Sealant W R GRACE & CO - CONN — CONSTRUCTION PRODUCTS DIV — FS 1900, FS 1901, FS 1905 and FS 1929 Sealant or FS900+ Sealant 'Bearing the UL Classification Mark + Bearing the UL Listing Mark • This writeup may, not This material was extracted by contain the latest revision Grace Construction Products from the UL Fire Resistance Directory System No. F -C -2087 June 23, 2000 F Rating —1 Hr TRating -1 Hr AMkMIYW(ii!wk r.04.: s W r I L Y .w ... n 1. Floor - Ceiling Assembly The 1 hr fire -rated solid or trussed lumber joist floor- ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor - Ceiling Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor - Ceiling Design. Max diam of opening is 5 in. B. Wood Joists Nom 2 by 10 in. lumber joists spaced 16 in. OC with nom 1 by 3 in. lumber bridging and with ends firestopped. As an altemate to lumber joists, nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Furring Channels (Not Shown) — Resilient galv steel furring installed perpendicular to wood joists (Item 1 B) between wallboard (Item 1D) and wood joists as required in the individual Floor-Ceiling Design. D. Gypsum Board* Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor - Ceiling Design. Wallboard secured to wood joists as specified in the individual Floor- Ceiling Design. 2. Closet Flange Polyvinyl chloride (PVC) or acrylonitrile butadiene styrene (ABS) closet flange installed in hole -sawed opening in flooring system with flange secured to top of flooring with steel screws. Diam of circular opening through flooring (Item 1A) to be max 1/2 in. larger than outside diam of closet flange. 3. Drain Piping Nom 4 in. diam (or smaller) Schedule 40 solid or cellular core PVC or ABS drain piping and fittings. Short length of pipe with 90 degree elbow fitting cemented into bottom socket of closet flange. Drain piping to soil stack cemented into elbow. 4. Fill, Vold or Cavity Material*— Fill material forced into annulus between closet stub and periphery opening in flooring to max extent possible, flush with bottom surface of floor. Additional fill material to be installed such that a min 3/8 in. crown is formed around the closet stub on bottom surface of floor. W R GRACE & CO - CONN CONSTRUCTION PRODUCTS DIV — FS1900, FS1901, FS1905 and FS1929 or FS900+ Sealant 1' 5. Water Closet (Not Shown) - Floor mounted vitreous china water closet. * Bearing the UL Classification Marking This material was extracted by This write up may not contain Grace Construction Products from the latest UL revision the UL Fire Resistance Directory XHEZ.F -C -2087 - Through - penetration Firestop Systems Page 1 of 3 C XH EZ. F -C -2087 Through - penetration Firestop Systems Page Bottom Design /System /Construction /Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through - penetration Firestop Systems See General Information for Through- penetration Firestoo Systems System No. F -C -2087 May 01, 2006 F Rating — 1 Hr T Rating — 1 Hr L Rating at Ambient - Less than 1 CFM /sq ft L Rating at 400° F - Less than 1 CFM /sq ft http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2087 - Through- penetration Firestop Systems Page 2 of 3 i \ 5 (1141 1 -- - - J i � k i....... w.rw' — .. . MfiiGi l . \ ME. &"1 gin- -. - -.. -: ' �.. - € i — ,;ag t .— ,„w. \ i. ,- - l .///). t J / M1 w1.... � • H - .4...I.m. ....wy...µ/ .. .�.wlNwMn A .. . • ... • 1 �.. _t— IwJr.wL..J..r.C.wMaw.Gw.I. Ir. A.. wwW... A.+ C.] Lw.Awiw...mJ— f_.J�A- 1-1. —.�1V� RvJGwN. if J (,-.4 4 1. Floor - Ceiling Assembly — The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor - Ceiling Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor- Ceiling Design. Max diam of opening is 5 in. (127 mm). B. Wood Joists — Nom 2 by 10 in. (51 by 254 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Furring Channels — (Not Shown) — Resilient galv steel furring installed perpendicular to wood joists (Item 1B) between gypsum board (Item 1D) and wood joists as required in the individual Floor - Ceiling Design. D. Gypsum Board* — Nom 4 ft (1.2 m) wide by 5/8 in. (16 mm) thick as specified in the individual Floor - Ceiling Design. Gypsum board secured to wood joists as specified in the individual Floor - Ceiling Design. 2. Closet Flange — Polyvinyl chloride (PVC) or acrylonitrile butadiene styrene (ABS) closet flange installed in hole -sawed opening in flooring system with flange secured to top of flooring with steel screws. Diam of circular opening through flooring (Item 1A) to be max 1/2 in. (13 mm) larger than outside diam of closet flange. 3. Drain Piping — Nom 4 in. (102 mm) diam (or smaller) Schedule 40 PVC or ABS drain piping and fittings. Short length of pipe with 90 degree elbow fitting cemented into bottom socket of closet flange. Drain piping to soil stack cemented into elbow. 4. Fill, Void or Cavity Material* — Sealant — Fill material forced into annulus between closet stub and periphery opening in flooring to max extent possible, flush with bottom surface of floor. Additional fill material to be installed such that a min 3/8 in. (10 mm) crown is formed around the closet stub on bottom surface of floor. W R GRACE & CO - CONN — FS1900, FS1901, FS1905 and FS1929 Sealant or FS900+ Sealant 5. Water Closet — (Not Shown) — Floor mounted vitreous china water closet. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2087 - Through - penetration Firestop Systems Page 3 of 3 *Bearing the UL Classification Mark Last Updated on 2006 -05 -01 Questions? Notice of Disclaimer Page Top Copyright CO 2009 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc. ®" An independent organization working for a safer world with integrity, precision and knowledge. aE MOW Aidia WINIIHMInee http : // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 System No. F -C -2089 November 14, 2001 F Rating — Hr T Rating —1 Hr t;$! tr 1. Floor - Ceiling Assembly The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor- Ceiling Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual floor- Ceiling Design. Rectangular cutout in flooring to accommodate the bathtub drain piping (Item 2) to be max 8 by 12 in. B. Wood Joists Nom 2 by 10 in. lumber joists spaced 16 in. OC with nom 1 by 3 in. lumber bridging and with ends firestopped. As an altemate to lumber joists, nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Furring Channels (Not Shown) — Resilient gals steel furring installed perpendicular to wood joists (Item 18) between wallboard (Item 1D) and wood joists as required in the individual Floor Ceiling Design. D. Gypsum Board* Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor - Ceiling Design. Wallboard secured to wood joists as specified in the individual Floor- Ceiling Design. One piece of gypsum wallboard, min 4 in. longer and wider than the cutout in the flooring, screw - attached to bottom of flooring concentric with cutout by means of 1 in. long Type S steel screws spaced max 5 in. OC. Diam of opening hole -sawed through the gypsum wallboard patch to be nom 1 in. larger than outside diam of bathtub drain piping (Item 2). 2. Drain Piping Nom 1 -1/2 in. diam Schedule 40 solid or cellular core polyvinyl chloride (PVC) or acrylonitrile butadiene styrene (ABS) pipe and drain fittings cemented together and provided with PVC bathtub waste /overflow fitting. Pipe to be installed either concentrically or eccentrically within the firestop system. The annular space within the firestop system shall be a min 3 /8 in. toa max 5 /8 in. 3. Fill, Void or Cavity Material* - Sealant - Min 5/8 in. thickness of fill material to be applied within annulus between the tee of the drain fitting and gypsum board patch on the top surface of the floor. An additional 1/4 in. crown of fill material shall be applied around tee of drain fitting on top surface of the gypsum board patch. WR GRACE &CO -CONN CONSTRUCTION PRODUCTS DIV — FS1900, FS1901, FS1905 and FS1929 or FS900+ Sealant Bearing the UL Classification Marking This material was extracted by This write up may not contain Grace Construction Products from the latest UL revision the UL Fire Resistance Directory XHEZ.F -C -2089 - Through - penetration Firestop Systems Page 1 of 3 XH EZ. F -C -2089 Through - penetration Firestop Systems Page Bottom Design /System /Construction /Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through - penetration Firestop Systems See General Information for Through - penetration Firestop Systems System No. F -C -2089 May 01, 2006 F Rating — 1 Hr T Rating — 1 Hr L Rating at Ambient - Less than 1 CFM /sq ft L Rating at 400° F - Less than 1 CFM /sq ft http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2089 - Through - penetration Firestop Systems Page 2 of 3 4 / 1 --- - , 1 ..w ., . j „ig F... }�, r - .. - i l i I 17 l 1 1............. / ffJ�t /` -' i S ... tiX 1\ N t r+ _I - -'r• ^-^ -- r te_ -.- +.�f — n. ' •+- �Y+- .ww.w..v.w -- r �i-+ ..w+.►- .... . r te . 1 ,_ I ,ic .) } ,n....... 1. Floor - Ceiling Assembly — The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor - Ceiling Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor - Ceiling Design. Rectangular cutout in flooring to accommodate the bathtub drain piping (Item 2) to be max 8 by 12 in. (203 by 305 mm). B. Wood Joists — Nom 2 by 10 in. (51 by 254 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Furring Channels — (Not Shown) — Resilient galv steel furring installed perpendicular to wood joists (Item 1B) between gypsum board (Item 1D) and wood joists as required in the individual Floor Ceiling Design. D. Gypsum Board* — Nom 4 ft (1.2 m) wide by 5/8 in. (16 mm) thick as specified in the individual Floor - Ceiling Design. Gypsum board secured to wood joists as specified in the individual Floor- Ceiling Design. One piece of gypsum board, min 4 in. (102 mm) longer and wider than the cutout in the flooring, screw- attached to bottom of flooring concentric with cutout by means of 1 in. (25 mm) long Type S steel screws spaced max 5 in. (127 mm) OC. Diam of opening hole -sawed through the gypsum board patch to be 1 in. (25 mm) larger than outside diam of bathtub drain piping (Item 2). 2. Drain Piping — Nom 1 -1/2 in. (38 mm) diam Schedule 40 solid or cellular core polyvinyl chloride (PVC) or acrylonitrile butadiene styrene (ABS) pipe and drain fittings cemented together and provided with PVC bathtub waste /overflow fitting. Pipe to be installed either concentrically or eccentrically within the firestop system. The annular space within the firestop system shall be a min 3/8 in. (10 mm) to a max 5/8 in. (16 http: / /database.ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2089 - Through- penetration Firestop Systems Page 3 of 3 mm). 3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material to be applied within annulus between the tee of the drain fitting and gypsum board patch on the top surface of the floor. An additional 1/4 in. (6 mm) crown of fill material shall be applied around tee of drain fitting on top surface of the gypsum board patch. W R GRACE & CO - CONN — FS1900, FS1901, FS1905 and FS1929 Sealant or FS900+ Sealant *Bearing the UL Classification Mark Last Updated on 2006 -05 -01 Questions? Notice of Disclaimer Page Top Copyright CO 2009 Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc. @" An independent organization working for a safer world with integrity, precision and knowledge. K ate-_ a � A ill 71 . http : / /database.ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 System No. F -C -2091 2A) F Rating —1 Hr 2 (- T Ratings — 3/4 and 1 Hr (See Item 4) , z , to 1. Floor Ceiling Assembly - The 1 hr fire -rated solid or trussed lumber joist floor ceiling assembly shall be constructed of the materials and in the — + - °- ! t ` i, _ - 1 manner specified in individual L500 Series Floor- Ceiling Designs in the UL � / ` , // �— �I Br a \\ / Fire Resistance Directory, as summarized below: ) //' A. Flooring System -- Lumber or plywood subfloor with finish floor of } /; / i . T _ lumber, plywood or Floor Topping Mixture* as specified in the individual F.. Y Floor- Ceiling Design. Max diam of floor opening is 5 in. B. Wood Joists — Nom 2 by 10 in. lumber joists spaced 16 in. OC with '61 nom 1 by 3 in. lumber bridging and with ends firestopped. As an altemate to V • f ' ' 9 (g) lumber joists, nom 10 in. deep (or deeper) lumber, steel or combination U n lumber and steel joists, trusses or Structural Wood Members* with 0 \.1V) 4C, bridging as required with ends firestopped. C. Furring Channels (Not Shown) — Resilient gals steel furring installed perpendicular to wood joists (Item 1B) between gypsum board (Item 1D) and wood joists as required in the individual Floor Ceiling Design. - D. Gypsum Board* — Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor- Ceiling Design. Gypsum board secured to wood joists as specified in the individual Floor - Ceiling Design. 2. Chase Wall — The through penetrant shall be routed (Item 3) through a 1 hr fire -rated single, double or staggered wood stud /gypsum board chase wall constructed of the materials and in the manner specified in individual U300 Series Wall and Partition Designs in the UL Fire — Resistance Directory and shall have the following construction details: CHASE WALL CONFIGURATION A A. Studs — Nom 2 by 6 in. or double nom 2 by 4 in. lumber studs. B. Sole Plate Nom 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 5 in. - C. Top Plate — The double top plate shall consist of two nom 2 by 6 in. or two sets of parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 5 in. D. Gypsum Board* — Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. CHASE WALL CONFIGURATION B - A. Studs — Nom 2 by 4 in., 2 by 6 in. or double 2 by 4 in. lumber studs. Nom 2 by 4 studs are allowed for a max 3 in. diameter penetrant. B. Sole Plate — Nom 2 by 4 in., 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted. Plate may be discontinuous over opening, terminating at both sides of periphery of opening. For openings 3 in. diam or less, plate may be continuous with opening cut in plate. Max diem of opening or max length of discontinuity is 4 in. _ C. Top Plate — The single top plate shall consist of nom 2 by 4 in., 2 by 6 in or parallel 2 by 4 in lumber plates, tightly butted. Plate may be discontinuous over opening, terminating at both sides of periphery of opening. For openings 3 in. diam or less, plate may be continuous with opening cut in plate. Max diam of opening or max length of discontinuity is 4 in. D. Steel Plate — For a nom 3 in. diameter penetrant through 2 by 4 in. lumber plates, two sides of noncontinuous lumber plates shall be - connected with nom 16 gauge (or heavier) 1 -1/2 in. wide steel plate. Steel plates to be sized in length to overlap a min of 4 in. onto each side of the noncontinuous plates and secured with a min of two %z in. long (or longer) No. 8 (or larger) wood screws on each side of each plate. E. Gypsum Board* Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. 3. Through Penetrants — One nonmetallic pipe to be centered within the firestop system. Diam of opening hole -sawed through flooring (Item 1B) and through both top plates (Item 2C) to be max 1/2 in larger than the outside diam of pipe. The pipe may be installed with continuous point contact. Pipe to be rigidly supported on both sides of floor - ceiling assembly. The following types nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 4 in. diam Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste, or vent) piping systems. B. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 4 in diam Schedule 40 cellular or solid core ABS pipe for use in (process or supply) or vented (drain, waste or vent) piping systems. 3A. Sanitary Tee — (Optional) — The vertical pipe (Item 3) may be provided with a Schedule 40 PVC or ABS sanitary tee above the top plate of the chase wall for connection of a nom 2 in. diam (or smaller) Schedule 40 solid or cellular core PVC or ABS drain pipe, respectively. Drain pipe to run horizontally through the concealed space above the ceiling and penetrate the flooring. Diam of the circular opening in the flooring - shall be a max 5/8 in. larger than the diam of the pipe such that a min 0 in. (point contact) to a max 5/8 in. annular space is present between the pipe and the periphery of the opening. The pipe may be installed with continuous point contact. 4. Fill, Void or Cavity Material* — Sealant — Min 3/4 in thickness of fill material applied within annulus, flush with top surface of floor. Min 5/8 in. thickness of fill material applied within annulus, flush with bottom surface of lower top plate of chase wall assembly. Additional fill _ material to be installed such that a min 3/8 in. bead is formed around the through penetrant on the top surface of floor and bottom surface of lower top plate of chase wall. When the optional sanitary tee is used, min 3/4 in. thickness of till material applied within annulus between drain pipe and flooring, on top surface of floor. Additional fill material to be installed such that a min 3/8 in. bead is formed around the drainpipe on the top surface of floor. If the through penetrant is installed with continuous point contact, a min %z in. thick bead of fill material shall be applied - around outer circumference of through penetrant on top surface of floor and bottom surface of lower top plate. The T Rating of the firestop system is dependent upon the t .e of sealant used within the firesto. s stem as shown in the table below: Tv .e of Fill Material T Ratin , Hr FS 900+ Sealant 3/4 FS 1900, FS1901, FS1905 and FS1929 Sealant 1 WR GRACE &CO -CONK CONSTRUCTION PRODUCTS DIV — FS 1900, FS 1901, FS 1905 and FS 1929 Sealant or FS900+ Sealant - *Bearing the UL Classification Mark This writeup may not This material was extracted by contain the latest revision Grace Construction Products from the UL Fire Resistance Directory XHEZ.F -C -2091 - Through - penetration Firestop Systems Page 1 of 5 ONLINE CERTIFICATIONS DIRECTORY XH EZ. F -C -2091 Through - penetration Firestop Systems Page Bottom Design /System /Construction /Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through - penetration Firestop Systems See General Information for Through - penetration Firestop Systems System No. F -C -2091 August 24, 2007 F Rating — 1 Hr T Ratings — 3/4 and 1 Hr (See Item 4) L Rating at Ambient - Less than 1 CFM /sq ft L Rating at 400° F - Less than 1 CFM /sq ft http: / /database.ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2091 - Through- penetration Firestop Systems Page 2 of 5 o wv . e w esaM ec� sa►* +►x..10. wre1.4,.r 1 Oft w 3 o:a e.viw . acto$14. 1 C «ekow1w yr IWO I 1. Floor - Ceiling Assembly — The 1 hr fire -rated solid or trussed lumber joist floor - ceiling assembly shall be constructed of the materials and in the manner specified in individual L500 Series Floor - Ceiling Designs in the UL Fire Resistance Directory, as summarized below: A. Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor - Ceiling Design. Max diam of floor opening is 5 in. (127 mm). B. Wood Joists — Nom 2 by 10 in. (51 by 254 mm) lumber joists spaced 16 in. (406 mm) OC with nom 1 by 3 in. (25 by 76 mm) lumber bridging and with ends firestopped. As an alternate to lumber joists, nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required with ends firestopped. C. Furring Channels — (Not Shown) — Resilient galv steel furring installed perpendicular to wood joists (Item 1B) between gypsum board (Item 1D) and wood joists as required in the individual Floor Ceiling Design. D. Gypsum Board* — Nom 4 ft (1.2 m) wide by 5/8 in. (16 mm) thick as specified in the individual Floor- Ceiling Design. Gypsum board secured to wood joists as specified in the individual Floor - Ceiling Design. Max diam of ceiling opening is 5in. (127mm). 2. Chase Wall (Optional) — The through penetrant (Item 3) may be routed through a 1 hr fire -rated single, double or staggered wood stud /gypsum board chase wall constructed of the materials and in the manner specified in individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall have the following construction details: CHASE WALL CONFIGURATION A http: / /database.ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME/showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2091 - Through - penetration Firestop Systems Page 3 of 5 A. Studs — Nom 2 by 6 in. (51 by 152 mm) or double nom 2 by 4 in. (51 by 102 mm) lumber studs. B. Sole Plate — Nom 2 by 6 in. (51 by 152 mm) or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Max diam of opening is 5 in. (127 mm). C. Top Plate — The double top plate shall consist of two nom 2 by 6 in. or two sets of parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Max diam of opening is 5 in. (127 mm). D. Gypsum Board* — Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. CHASE WALL CONFIGURATION B A. Studs — Nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or double 2 by 4 in. (51 by 102 mm) lumber studs. Nom 2 by 4 in. (51 by 102 mm) studs are allowed for a max 3 in. (76 mm) diameter penetrant. B. Sole Plate — Nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Plate may be discontinuous over opening, terminating at both sides of periphery of opening. For openings 3 in. (76 mm) diam or less, plate may be continuous with opening cut in plate. Max diam of opening or max length of discontinuity is 4 in. (102 mm). C. Top Plate — The single top plate shall consist of nom 2 by 4 in. (51 by 102 mm), 2 by 6 in. (51 by 152 mm) or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly (76 mm) butted. Plate may be discontinuous over opening, terminating at both sides of periphery of opening. For openings 3 in. (76 mm) diam or less, plate may be continuous with opening cut in plate. Max diam of opening or max length of discontinuity is 4 in. (102 mm). D. Steel Plate — For a nom 3 in. (76 mm) diameter penetrant through 2 by 4 in. (51 by 102 mm) lumber plates, two sides of non - continuous lumber plates shall be connected with nom 16 gauge (or heavier) 1 -1/2 in. (38 mm) wide steel plate. Steel plates to be sized in length to overlap a min of 4 in. (102 mm) onto each side of the non - continuous plates and secured with a min of two 1 /2 in. (13 mm) long (or longer) No. 8 (or larger) wood screws on each side of each plate. E. Gypsum Board* — Thickness, type, number of layers and fasteners shall be as specified in individual Wall and Partition Design. 3. Through Penetrants — One nonmetallic pipe to be centered within the firestop system. Diam of opening hole -sawed through flooring (Item 1B) and through both top plates (Item 2C) to be max 1/2 in. (13 mm) larger than the outside diam of pipe. The pipe may be installed with continuous point contact. Pipe to be rigidly supported on both sides of floor - ceiling assembly. The following types nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste, or vent) piping systems. B. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. 3A. Sanitary Tee (Optional) — The vertical pipe (Item 3) may be provided with a Schedule 40 PVC or ABS sanitary tee above the top plate of the chase wall for connection of a nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular core PVC or ABS drain pipe, respectively. Drain pipe to run horizontally through the concealed space above the ceiling and penetrate the flooring. Diam of the circular opening in the flooring shall be a max 5/8 in. (16 mm) larger than the diam of the pipe such that a min 0 in. (point contact) to a max 5/8 in. (16 mm) annular space is present between the pipe and the periphery of the opening. The pipe may be installed with continuous point contact. 4. Firestop System — The firestop system shall consist of the following: A. Fill, Void or Cavity Material* — Sealant — Min 3/4 in. (19 mm) thickness of fill http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2091 - Through - penetration Firestop Systems Page 4 of 5 material applied within annulus, flush with top surface of floor or top surface of the sole plate of chase wall assembly (when used). Min 5/8 in. (16 mm) thickness of fill material applied within annulus, flush with the bottom of the gypsum ceiling or bottom surface of lower top plate of chase wall assembly (when used). Additional fill material to be installed such that a min 3/8 in. (10 mm) bead is formed around the through penetrant on the top surface of floor or top surface of the sole plate of chase wall assembly (when used) and the bottom of the gypsum ceiling or bottom surface of lower top plate of chase wall (when used). When the optional sanitary tee is used, min 3/4 in. (19 mm) thickness of fill material applied within annulus between drain pipe and flooring, on top surface of floor. Additional fill material to be installed such that a min 3/8 in. (10 mm) bead is formed around the drain pipe on the top surface of floor. If the through penetrant is installed with continuous point contact, a min 1/2 in. (13 mm) thick bead of fill material shall be applied around outer circumference of through penetrant on top surface of floor and bottom surface of lower top plate. The T Rating of the firestop system is dependent upon the type of sealant used within the firestop system as shown in the table below: Type of Fill Material T Rating, Hr FS 900+ Sealant 3/4 FS 1900, FS1901, FS1905 and FS1929 Sealant 1 W R GRACE & CO - CONN — FS1900, FS1901, FS1905 and FS1929 Sealant or FS900+ Sealant B. Fill, Void or Cavity Material* — Wrap Strip — Nom 1/4 in. thick intumescent material faced on both sides with a plastic film, supplied in 1 in. wide strips. Two layers of wrap strips are individually wrapped around the through - penetrant with the ends butted and held in place with masking tape. Butted ends in successive layers shall be offset or aligned. The wrap strips are wrapped around vertical through - penetrant (Item 3) on underside of gypsum board ceiling or bottom surface of lower top plate of chase wall assembly (if used). W R GRACE & CO - CONN — FlameSafe Wrap Strip C. Steel Collar — Collar fabricated from coils of precut 0.018 in. thick (28 MSG) galv sheet steel available from wrap strip manufacturer. Collar shall be nom 1 in. deep with min four 1 in. wide by 2 in. long anchor tabs for attachment to underside of ceiling or bottom surface of lower top plate of chase wall assembly (if used). Retainer tabs, 3/4 in. wide tapering down to 1/4 in. wide and located opposite the anchor tabs, are folded 90 degrees toward through - penetrant surface to maintain the annular space around the through - penetrant and to retain the wrap strips. Steel collar wrapped around wrap strips and vertical through - penetrant (Item 3) with a 1- 1/2 in. wide overlap along its perimeter joint and secured together by means of a min 1/2 in. wide by 0.028 in. thick stainless steel hose clamp installed at mid - height of the collar. Collar secured to ceiling or bottom surface of lower top plate of chase wall assembly (if used) at each anchor tab with 3/16 in. diam by min 3 in. long toggle bolts in conjunction with min 1/4 in. by 1 -1/4 in. diam steel fender washers. *Bearing the UL Classification Mark Last Updated on 2007 -08 -24 9uestions? Notice of Disclaimer Page Top Copyright n 2009 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from http:// database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.F -C -2091 - Through - penetration Firestop Systems Page 5 of 5 Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc.®" An independent organization working for a safer world with integrity, precision and knowledge. // ,dU ai 010414, http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =XH... 2/9/2009 System No. W -L -2170 November 02, 2000 F Ratings —1 and 2 Hr (See Item 2) T Ratings — 0 and 1 Hr (See Item 2) frf ilAl an $ CrioN_ 1. Wall Assembly The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 3 -5/8 in. wide and spaced max 24 in. OC. B. Wallboard, Gypsum Board* 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 4 in The hourly F and T Ratings of the firestop system are dependent on the hourly fire rating of the wall and type and diam of through penetrant as shown in Item 2. 2. Nonmetallic Pipe One nonmetallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between the through penetrant and the periphery of the opening is dependent upon the diam of through penetrant. If the nom diam of the through penetrant is 1 -1/2 in. or less, the annular space shall be a min 3/8 in. to max 1 -1/8 in. If the nom diam of the through penetrant is greater than 1 -1/2 in. , the annular space shall be a min 5/8 in. to max 1 in. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types of nonmetallic pipes, conduits or tubing may be used: A. Polyvinyl Chloride (PVC) Pipe Nom 2 in. diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste, or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe Nom 2 in. diam (or smaller) SDR 17 CPVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. C. Rigid Nonmetallic Conduit+ Nom 2 in. diam (or smaller) Schedule 40 PVC conduit installed in accordance with Article 347 of the National Electrical Code, (NFPA No. 70). D. Acrylonitrile Butadiene Styrene (ABS) Pipe Nom 1 -1/2 in diam Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. E. Electrical Nonmetallic Tubing (ENT)+ Nom 1 -1/2 in. diam (or smaller) PVC tubing installed in accordance with Article 331 of the National Electrical Code, (NFPA No. 70). F. Cross Linked Polyethylene (PEX) Tubing Nom 1 -1/2 in. diam (or smaller) SDR 9 cross linked polyethylene (PEX) tubing for use in closed (process or supply) piping systems. The hourly F and T Ratings of the firestop system are dependent on the hourly fire rating of the wall and type and max diam of through penetrant as tabulated below: Rating of Type of Through Max Diam of F T Wall, Hr Penetrant Through Rating Rating Penetrant, In Hr Hr 2 ' PVC Pipe, CPVC Pipe or PVC Conduit : 2 2 1 2 PVC ENT 1 -1/2 2 1 2 ABS Pipe or PEX Tubing 1 -1/2 2 0 1 PVC Pipe, CPVC Pipe or PVC Conduit 2 1 0 1 PVC ENT, ABS Pipe or PEX Tubing 1 -1/2 j t 0 3. Fill, Void or Cavity Material* — Sealant Min 5/8 in. thickness of fill material applied within annulus, flush with both surfaces of wall. Additional fill material to be installed such that a min 1/4 in. thick crown is formed around the penetrating item. W R GRACE & CO - CONN CONSTRUCTION PRODUCTS DIV — FS 1900, FS 1901, FS 1905 and FS1929 Sealant *Bearing the UL Classification Marking +Bearing the UL Listing Mark This writeup may not contain This material was extracted the latest UL revision by Grace Construction Products from the UL Fire Resistance Directory XIIEZ.W -L -2170 - Through - penetration Firestop Systems Page 1 of 3 Of, ; . ; XHEZ.W -L -2170 Through - penetration Firestop Systems Page Bottom Design /System /Construction /Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through - penetration Firestop Systems See General Information for Through - penetration Firestop Systems System No. W -L -2170 May 02, 2006 F Ratings — 1 and 2 Hr (See Item 2) T Ratings — 0 and 1 Hr (See Item 2) L Rating at Ambient - Less than 1 CFM /sq ft L Rating at 400° F - Less than 1 CFM /sq ft http : / /database.ul.com/cgi- bin/XYV /template /LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 XHEZ.W -L -2170 - Through - penetration Firestop Systems Page 2 of 3 J t IA , is A ^5 .. S• i t l ' I x `�w 1 ♦ 1 1 i --. .. mss. •t .... i. .1" ..erl) ,..,.. ,._ \, ti1 '• � - " / ' +� , 1 - x ? Y l am. -�-� � r "4y.. .. 1. Wall Assembly — The 1 or 2 hr fire -rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300, U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3 -5/8 in. (92 mm) wide and spaced max 24 in. (610 mm). OC. B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.2 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300, U400 or V400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 4 in. (102 mm). The hourly F and T Ratings of the firestop system are dependent on the hourly fire rating of the wall and type and diam of through penetrant as shown in Item 2. 2. Nonmetallic Pipe — One nonmetallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between the through penetrant and the periphery of the opening is dependent upon the diam of through penetrant. If the nom diam of the through penetrant is 1- 1/2 in. (38 mm) or less, the annular space shall be a min 3/8 in. (10 mm) to max 1 -1/8 in. (29 mm). If the nom diam of the through penetrant is greater than 1 -1/2 in. (38 mm), the annular space shall be a min 5/8 in. (16 mm) to max 1 in. (25 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types of nonmetallic pipes, conduits or tubing may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 2 in. (52 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste, or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 2 in. (52 mm) diam (or smaller) SDR 1713.5 CPVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. C. Rigid Nonmetallic Conduit+ — Nom 2 in. diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code, (NFPA No. 70). D. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 1 -1/2 in. (38 mm) diam Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 XIHEZ.W -L -2170 - Through - penetration Firestop Systems Page 3 of 3 E. Electrical Nonmetallic Tubing (ENT)+ — Nom 1 -1/2 in. (38 mm) diam (or smaller) PVC tubing installed in accordance with the National Electrical Code, (NFPA No. 7 F. Cross Linked Polyethylene (PEX) Tubing — Nom 1 -1/2 in. (38 mm) diam (or smaller) SDR 9 cross linked polyethylene (PEX) tubing for use in closed (process or supply) piping systems. The hourly F and T Ratings of the firestop system are dependent on the hourly fire rating of the wall and type and max diam of through penetrant as tabulated below: Rating Type of Through Max Diam of F T of Penetrant Through Rating Rating Wall, Hr Penetrant, In. Hr Hr (mm) 2 PVC Pipe, CPVC Pipe or PVC 2 (51) 2 1 Conduit 2 PVC ENT 1 -1/2 (38) 2 1 2 ABS Pipe or PEX Tubing 1 -1/2 (38) 2 0 1 PVC Pipe, CPVC Pipe or PVC 2 (51) 1 0 Conduit 1 PVC ENT, ABS Pipe or PEX Tubing 1 -1/2 (38) 1 0 3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. Additional fill material to be installed such that a min 1/4 in. (6 mm) thick crown is formed around the penetrating item. W R GRACE & CO - CONN — FS1900, FS1901, FS1905 and FS1929 Sealant *Bearing the UL Classification Marking +Bearing the UL Listing Mark Last Updated on 2006 -05 -02 Questions? Notice of Disclaimer Page Top Copyright n 2009 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc. ®" An independent organization working for a safer world with integrity, precision and knowledge. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =XH... 2/9/2009 General Certificate of Conformance Flame Safe Firestop Products FlameSafe FS 1900 Sealant FlameSafe FS3000 Coating FlameSafe FS900+ Sealant FlameSafe FS2900 Coating FlameSafe FS900 Sealant' FlameSafe FSIS Intumescent Sleeve FlameSafe Mortar Seal FlameSafe Pillows FlameSafe® FSP 1100 Putty FlameSafe® Bags FlameSafe FSP1077 Putty Pad KBS Sealbags FlameSafe FSP1000 Putty FlameSafe FS500 / FST600 Sealant' FlameSafe FSWS Wrap Strip FlameSafe C700S Safing Sealant FlameSafe S100 Sealant' FlameSafe PB 100 Panel Board FlameSafe FSD Device FlameSafe Silicone Sealant THESE PRODUCTS COMPLY WITH THE FOLLOWING ASTM STANDARDS: ASTM E 119 Fire Tests of Building Construction and Materials ASTM E 814 Fire Tests of Through Penetration Fire Stops (Under positive furnace pressure of minimum .01 inches of water) 1 ASTM E 84 Surface Burning Characteristics of Building Materials 2 ASTM E 1966 Test Method for Fire Resistive Joint Systems 2 ASTM E 1399 Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems No asbestos or PCBs are used or contained in these products. Michael Richardson Craig Boucher Worldwide QA Manager Technical Services Engineer 10/9/03 10/9/03 Date Date a r �� � , f xr `y W -, fib"` -' ri z' ` ' :',41 '� o tr-x ' .. 1 ' w: : s ue, ii.. w ww1i41.graceconstrucijon ■cof 1r PRODUCT DATA ■ UPDATES •TECH LETTERS ■DETAILS •MSDS •CONTACTS ■FAQS ir + .> y } g FlameSafe® FS 1900 Sealant ` . Intumescent, Elastomeric Firestop B enefits n x r ,,,, ,... -„ v g #�,pr' "p r i A" °' • Underwriters Laboratories ' �, .1','.:.'. • � � r�0" s 4 1 classified • Factory Mutual approve • ,' 43t 4` • Hundreds of firestop through fi ' ` � - ¢�4 4' ,. .� _ penetration and joint systems ;0 , ` .��' A , 1')'` �" .? � � . 0'.1 `. x • Listed in systems with up to 4 ''' ' fli = i . 3 hour fire rating � <4 9 . "� • Tested to UL 1479 (ASTtiI E814), - x , . ' � ~ UL 2079 (ASTM E1399), ASTM . . -� -' C719, UL 723 (ASTM E84) ' = *, „,,,&.„, ; • Sound transmission tested in � , " It � ' — accordance with ASTM E90 r 1, ,, � • Water- based, easy to use � — and clean up ” ` m k ' • Excellent adhesion to a variety "' of substrates and penetrants . _-� '` g Flamesafe FS 1900 Sealant — • Used in bus and HVAC ducts, construction joints and for the demanding firestop require- CPVC, cc -PVC, ABS, cc -ABS, through penetrations with ments of pipe, cable, sprinkler PEX, insulated pipe and plastic mixed penetrants, metallic or penetrations and construction coated cables. non-metallic pipes joints when subjected to frequent • No solvents, silicones FS 1900 does not contain solvents expansion and contraction. and , as a result, is not toxic and — or outgassing FS 1900 is intumescent and will not p damage plastic pipes or • Elastomeric expands to fill the void created by cable jackets. p p • Paintable the melting and burning of PVC, — • Caulkable or trowelable Physical Properties Description FlameSafe® FS 1900 Sealant is a Color _....._.. __........_...---..._..__..: ......... ...._....__.........---- ._...._ Red high performance, elastomeric and Weight _ 1 10.0 lbs/ al (1.2 kg/L) intumescent sealant. It is a high Storage and Installation Temperatures_ 40 °F to 90 °F (4 °C to 32 °C ) solids, water -based compound ASTM C719 Passed — engineered to provide exceptional adhesive and elastomeric properties Flame Spread (UL 723 /ASTM E84) 0 Smoke Developed (UL 723 /ASTM E84) 5 GRACE Construction Products — ¢ Applications Figure 1 FlameSafe FS 1900 is used to seal 1 l uL classified steel or wood stud fire openings in fire -rated structures. zie, A. A. rated wallboard assembly r Systems are available for metallic A B. FlameSafe FS 1900 at 0.625 in. (16 mm) .': l' 4,7 , ' and non - metallic pipe, cable, „` `L C. Max. 2 in. (50.8 mm) dia. PVC, CPVC conduit, cable tray and duct B ABS, or non - metallic conduit 1. ..:!.4. iiimil Max. 1.5 in, (38 mm) dia. ENT tubing penetrations through typical wall and floor construction. Also available for joints between fire- 1 if/1i' resistive assemblies (such as wall- 0. 1 , :-; . ' to -wall floor -to -floor and head of wall), concrete, masonry, fluted See note f • deck and gypsum substrates, wood t ABS CPVC 8 PVC Through Gypsurn Wall la and 2 Four (ULW L2 ..770) s ' ' ,, " fi r g '4 x x i t ,, 4 , ; ; joist floor -to- ceiling and chase wall assemblies. See Figures 1 -3 for Figure 2 examples of typical details. , A. FlameSafe FS 1900 applied a min. 1 in. 0 — A (25.4 mm) thick flush with the floor FS 1900 is particularly suited for 1 Apply a 0.375 in. (9.5 mm) bead at � the point of contact use in applications where system A B. � Min. 4.5 in. (114 mm) concrete floor R vibration and building movement — ti 1111 x „. g B or wall are concerns. W ' ° - C. Backer rod polyurethane backing P : roger' C 0. Max. 24 in. (610 mm) dia. or smaller ,; steel or cast iron pipe t D Max. 4 in. (102 mm) dia. EMT conduit Application Guide Max. 6 in. (152 mm) copper pipe or Penetrations I � steel conduit • — -- — 'See note Metallic X fv1 t.o1 b6. Though Concrete Floor or Wall -3 Hour (UL C A,1 1235Y § x R r _ _ _X — x ° <a fi a . - fir i k i t 4 *,; 4 W -, Cables I X • F igure 3 A l ,. Cable Tra . s - 1 X e A. FlameSafe FS 1900 applied at floor I nsulated 1 X surface to a 0.75 in. (19 mm) depth }_...._...._ _......_.._ -._. s A B C D with a 0.375 in. (9.5 mm) crown Misc. Electrical 1 X B . Nominal 2 in. x6 in. (50.8 mm x 152 mm) — i x"' ,/? or parallel 2 in. x 4 In. (50.8 mm x 102 mm) H VAC + X _ lumber plates Mixed i X C. Min. 0.75 in. (l9 mm) lumber or plywood subfloor Joints Max. 5 in. (125 mm) opening -- -- - -- X - - -- D. Nominal 2 in. x 10 in. (50.8 mm x 250 mm) Perimeter Barrier lumber joists �� E. Double top plate consisting of two (Curtain Wall) _ _ — -- 2 In. x6 in. (50.8mmx 152mm)or ' two sets of parallel 2 in. x 4 in. '� (50.8 mm x 102 mm) lumber studs Applicable Standards E F. Max. 41n, (102 mm) dia. PVC, ABS • FlameSafe FS 1900 is classified by A � I ' (solid or cellular core) and CPVC f piping as an open (vented) or Underwriters Laboratories Inc. and closed system G FlameSafe FS 1900 applied at bottom 1` ' by Underwriters' Laboratories of — _ � of top plate to a 0.75 in. (19 mm) At depth with 0.375 in. (9.5 mm) crown Canada for 1, 2 and 3 hour rated systems, in accordance with AST ?..t,' H. One layer of gypsum wallboard E814 (UL 1479/CAN 4- S1151\4), H G F ceiling capable of providing o 1 hr rating 0.4i ' See note ;;Wood .lolst and Chose Wall Floor Ceiling - 1 Hour (UL F-C-2082) *Refer to UL designs for full system description. — "Fire Tests of Through - Penetration FS 1900 is approved by the City of and material used may vary Firestops" and UL 2079, New York (MEA 83 -89 -M Vol. V, according to the size of opening "Standard for Fire Tests of Joint 47 -98 -M Vol. II, 179 -96 -M Vol. II), being protected and the type of Systems." FS 1900 is Factory the California State Fire Marshal penetrant. Material may be installed Mutual approved and listed by (4485 - 1551:103) and ICBO. using a standard or powered caulk Warnock Hersey. It has been tested gun, or troweled into place using a to and passed ASTNI C719, Installation mason's trowel or putty knife. — "Adhesion/Cohesion of All contact surfaces must be free of FlameSafe FS 1900 is a water -based Elastomeric Joint Sealant for loose dirt, scale, oil or other foreign sealant and time required for drying Cyclic Movement." In addition, materials. Installation procedures will vary according to — environmental conditions. 7` °' 4 ` Maintenance Figure 4 rx, Applications using FlameSafe A. FlameSafe FS 1900 Sealant W' 4110 0.51n. (13 mm) deep FS 1900 are maintenance free, A B. Mineral wool Insulation (4 pcf), however, installations should be 2 in. (50.8 mm) deep B C. Min. 4.5 in. (114 mm) NW or LW 1,1 inspected periodically for 4 AI �,;, / ' concrete floor or wall D. Max. 12 in. (305 mm) steel or iron pipe , accidental damage and repaired as original a with a max. 1 in. (25.4 mm) fiberglass } per the approved design. insulation `t D Warranty All statements, technical information and recommendations A contained herein are based on tests — a 'see note we believe to be reliable. However, s .. since the conditions of use and felt el E ThiouaF Co ra F[ r • ,v �!r 1 t5T s " , t k s � a�, a pplicat ion are beyond our control, *Refer to UL designs for full system description. Grace Construction Products shall not be liable for any damage, direct :,- A or consequential, resulting from the 'AAyaj5,11!'''' t . , . .�� � s , � h use of this material or design. . — Flam a f t " 19{ 0 Se lant is ava�l'ab t�trntl � u r� r qe s Grace Construction Products only Consrrt ctton Products distributors in t otIowm qtt , t1 w tes . warranty shall be to replace any of — � its products found to be defective. � � . � P ac k. Description Part No. o �� u ��_ � , �� Sfd T echnical Support Caulk Tubes 4 4. �: � � `i ' ,. f t ; %. Grace Construction Products Caulk Tube: ' "` 2 19 in ' ..,44±. 12 provides technical support for �h 10.3 oz (305 1111 'F 4 ;:0; "; (312 cm ,, = all of its products, including Caulk Tube* 26874 57 in. 6 FlameSafe FS 1900 Sealant. Call 31 oz (0.92 L) (934 cm3) toll free at 866 - 333 -3SBM (3726) 74 for assistance in product selection Sausage Pack --1,1t4_ 4, 37 in. 12 and for detailed specifications and 20.2 oz (0.62 L) ? r (606 cm approvals. We provide engineering analysis for unique firestopping Poly Pails applications, including system Poly Pail 26872 ,- 231 in. 4 design drawings suitable for 1 gal (3.8 L) (3,788 cm3) submittals. Material Safety Data Poly Pail 26873 1,155 in.3 1 Sheets are also available. More 5 gal (19.0 L) (18,942 cm3) information is available at our web For use with powered caulk gun only. Call Grace Construction Products for tool site, www.graceconstruction.com. recommendation. product Estimating Guide for Through- Penetrations -- (Volume in cubic inches assuming 0.5 inch required depth) PIPE 1 SIZE Size of Round Opening (Inches) Pipe O.D. 1 Trade Size 6.5 I 7 8 j 9 1 10 11 12 13 i 14 1 15 1 16 � 1 1 18 19 20 0.54 1/4 0.3 11.5 3.4 1 6.2 i __ ! 0.68 3 /g 0.2 1 1.4 3 16.1 1 0 .84 1 3/, 0.1 1 1.3 3.3 6.0 . ; 1.05 3 /4 1 1.1 3.1 15.8 j j - � 1.32 1 i 0.9 2.8 1 5.6 r 9.1 _� I I I 1.66 1 0,5 2.5 i 5,2 1 8,7 1 hh F - j i - 1.90 11 0.2 2.1 1 4.9 j 8.4 1 I . 2.38 2 1.3 4.1 1 7.6 , . 1 1.9 1 I j _ I I 2.88 21/2 1 0 10.91 3.50 3 i , 1.5 1 5.0 9.3 , 14.4 20.3127.0 _ 4.00 31 1 1 3.S 7..9 1 13.0 18.8 25.51 1 _ 11 11 4.50 4 11.9 6.2 1 11.3 17.2 23.9' 31,3 39.6148.6. 1 1 5.56 I 5 2.0 7.1 13.0 19.7 27.1 35.61 44.4 I ; _ 6.63 6 ' 2.0 7.91 14.5 , 22.0 30 21 39.3 49.1 59,71 71,1 8.6 8 1 1 2.6110.0 18.3127.3 37.1147.7159.1 10.75 10 1 i 1 2.1111.2 21.0 31.6143.0 51.1 68.1 81.8 12.75 12 2.51 13.1 1 24.5 36.7 49.6 63.4 14.00 14 � 1 1 I t 11.4 23.5 36.5 50.2 64.8 ' .1 16.00 1 16 I i h 12.9 26.7 41.2 56.5 80 - 18.00 1 18 i 1 1 I 14.5 29.8 ` a a s s- , :r • , mm r . z r �` 1:',4: a , 'w: . a.' + aNla 1 $1 3R z �f • :� B s 2,111, ® i i° J FGI:> C US APPROVED I �JF c..l s , - For Technical Assistance call toll free at 866- 333 -3SBM (3726). wb Visit our web site at www.graceconstruction.com J printed on recycled paper W. R. Grace & Co.-Conn. 62 Whittemore Avenue Cambridge, MA 02140 - FlameSafe is a registered trademark of W. R. Grace & Co.•Coan. Wr hope the information here will be helpful. k u based un data and knowledge considered to be true and accurate and is offered for the usres' consideration, investigation and veritiution. but we du not warrant the results to be obtained. Pjease read all staremetts, recormnendations or suggestions in conlututiun with our conditions u l sale, which apply to 311 goods supplied by us. No st rec n or snggrsra is intended fur any us which would infriogr any cop W. R. Grace & Co.-Conn., 61 Whittemore Avenue, Cambridge, V li\ 02140. In Canada, Grace C;tnada, Inc., 294 Clements Road, West, Ajax, Onta[io, parent ur CC.111.11 L15 3C6. - These products may be covered by y patents or parents pending. Copyright 1003. W. R. Grace & Co.-Conn. FS-100C Printed in USA 5/03 F.VII/.tbt Construction Products m W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS ID Number: Z- 01569 MSDS Date: 11/05/2002 SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS Number: Z -01569 Cancelled MSDS Number: Z -01552 MSDS Date: 11/05/2002 Chemical Family Name: Polyvinyl Acetate & Acrylic Latex Based Emulsion Product Use: Intumescent, Elastomeric Firestop Chemical Formula: Mixture -NA CAS # (Chemical Abstracts Mixture -NA Service Number): Manufactured by: W.R. Grace & Co. -Conn. Grace Canada, Inc. 62 Whittemore Avenue 294 Clements Road West Cambridge, MA 02140 Ajax, Ontario L1S 3C6 In Case of Emergency Call: In USA: (617) 876 -1400 In Canada: (905) 683 -8561 SECTION 2 - COMPOSITION /INFORMATION ON INGREDIENTS Ingredient CAS# Percent (max) 2- Propenoic acid, polymer.. 052640 -81 -0 10 -20 Dipentaerythritol 000126 -58 -9 1 -5 _ Graphite 007782 -42 -5 1 -5 Melamine 000108 -78 -1 1 -5 Methenamine 000100 -97 -0 < 1 Phenol, isopropylated, phosphate (3:1) 068937 -41 -7 5 -10 Phenol - formaldehyde polymer 009003 -35 -4 1 -5 Polyvinyl Acetate Emulsion NJ801415075P 10 -20 Pseudocumene 000095 -63 -6 < 1 Silicic acid, sodium salt 001344 -09 -8 5 -10 Talc 014807 -96 -6 1 -5 Triphenyl phosphate 000115 -86 -6 1 -5 Zinc borate 001332 -07 -6 1 -5 www.graceconstruction.com Page 1 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS ID Number: Z -01569 MSDS Date: 11/05/2002 SECTION 3 - HAZARDS IDENTIFICATION Emergency Overview: Warning! Causes mild to moderate eye irritation. Causes respiratory tract irritation. May be harmful if ingested. Causes digestive tract irritation if ingested. Harmful if absorbed through skin. HMIS Ratin Health: 2* Flammability: 0 Reactivity: 0 Personal Protective Equipment: B (See Section 8) Potential Health Effects: Inhalation: Causes respiratory tract irritation. Prolonged inhalation may cause sensitization. Effects include: Nausea, sneezing, coughing, itching, tightness of chest and wheezing. Hypersensitive individuals may experience allergic respiratory reaction. Eye Contact: Eye contact causes mild to moderate irritation. Skin Contact: Acute skin contact is not expected to cause irritation. Hypersensitive individuals may develop an allergic reaction resulting in dermatitis, rash or hives. Skin Absorption: Harmful if absorbed through the skin. -' Ingestion: Harmful if ingested. If ingested, causes irritation to the linings of the mouth, esophagus and stomach. Effects include the following: No other effects expected unless listed below. Reproductive and developmental effects have been reported for certain ingredients. Long -term repeated ingestion of small amounts of product may cause a decrease in red blood cells or liver and kidney damage. Phenol- formaldehyde polymer has tested positive as a mutagen. www.graceconstruction.com Page 2 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: F1ameSafeS FS 1900 Series Firestpp Sealant MSDS ID Number: Z -01569 MSDS Date: 11/05/2002 SECTION 4 - FIRST AID MEASURES: Skin Contact: Wash with soap and water. If discomfort or irritation persists, consult a physician. Remove contaminated clothing and wash before reuse. Eye Contact: -- If discomfort or irritation persists, consult a physician. Flush eyes with water for at least 15 minutes while holding eyelids open. Ingestion: If discomfort or irritation persists, consult a.physician. Never give anything by mouth to an unconscious person. Do not induce vomiting. Inhalation: If symptoms develop, get fresh air. If symptoms persist, consult a physician. If breathing has stopped, give artificial respiration then oxygen if needed. SECTION 5 - FIRE .4ND >EXPLOSION HAZARD DATA Flash Point: >212 °F /100 °C Flash Point Method: Estimated Lower Explosion Limit: Not Available Upper Explosion Limit: Not Available Auto - Ignition Temperature: Not Available NFPA Rating: Health: 1 Flammability: 0 Reactivity: 0 Extinguishing Media: Product will not support combustion. Use alcohol foam, Carbon dioxide, dry chemical or water to treat surrounding fire. Special Fire Fighting Procedures: Wear self - contained breathing apparatus and complete personal protective equipment when potential for exposure to vapors or products of combustion exist. Isolate area and keep unnecessary people away. No special procedures specific to this product. Unusual Fire and Explosion Hazards: During fire, oxides of nitrogen may be evolved. www.graceconstruction.com Page 3 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafee FS 1900 Series Firestop Sealant MSDS ID Number: Z- 01569 MSDS Date: 11/05/2002 SECTION 6 - ACCIDENTAL RELEASE MEASURES: Spills/Leaks: Use proper personal protective equipment. Do not flush to sewer or allow to enter waterways. Keep unnecessary people away. SECTION 7 - HANDLING AND STORAGE Precautionary Measures: Avoid contact with eyes, skin and clothing. Do not take internally. Practice good personal hygiene to avoid ingestion. Use only with adequate ventilation. Wash clothing before reuse. FOR PROFESSIONAL USE ONLY. KEEP OUT OF CHILDREN'S REACH. SECTION 8 - EXPOSURE CONTROLS AND PERSONAL PROTECTIVE EQUIPMENT EXPOSURE GUIDELINES (US) Ingredient ACGIH TLV OSHA PEL Other TWA STEL Ceiling TWA STEL Ceiling 2- Propenoic acid, polymer.. - - - - " - - Dipentaerythritol Graphite 2 mg/m3 - respirable - - TWA dust: 2.5 (respirable mg/m3 fraction) TWA (all forms except graphite fibers) Melamine ' - - - - - Methenamine - - - - Nitric acid 2 ppm 4 ppm STEL - 2 ppm 4 ppm - - TWA TWA; 5 STEL; mg/m3 10 TWA mg/m3 STEL Phenol, isopropylated, phosphate (3:1) - - - - - - Phenol - formaldehyde polymer - - - - - - Polyvinyl Acetate Emulsion - - - - - " — Pseudocumene - - - - - - Silicic;acid, sodium salt - - - - - Sulfuric acid 1 mg/m3 3 mg/m3 - 1 mg/m3 - - TWA STEL TWA www.graceconstruction.com Page 4 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS ID Number: Z -01569 MSDS Date: 11/05/2002 SECTION 14 - TRANSPORTATION INFORMATION Proper Shipping Name: Not Applicable UN/NA Number: Not Applicable Domestic Hazard Class: Nonhazardous Surface Freight Classification: Not Applicable Label/Placard Required: Not Applicable SECTION 15 - REGULATORY INFORMATION REGULATORY CHEMICAL LISTS: CERCLA (Comprehensive Response Compensation and Liability Act): (None present unless listed below) Chemical Name CAS # Wt % CERCLA RO Zinc borate 001332 -07 -6 3.9 1,000 SARA Title III (Superfund Amendments and Reauthorization Act) SARA Section 312/Tier I & II Hazard Categories: Health Immediate (acute) Yes Health Delayed (chronic) Yes Flammable No Reactive No Pressure No 302 Reportable Ingredients (Identification Threshold 1 %.): Chemical Name CAS # Wt % SARA 302 TPO www.graceconstruction.com Page 8 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS ID Number: Z -01569 MSDS Date: 11/05/2002 313 Reportable Ingredients (Chemicals present below reporting threshold are exempt): Chemical Name CAS # Wt Acetaldehyde 000075 -07 -0 .0015 Acrylamide 000079 -06 -1 .0009 Acrylonitrile 000107 -13 -1 .0003 Cumene 000098 -82 -8 .0201 Ethyl acrylate 000140 -88 -5 .0024 Ethylene Glycol 000107 -21 -1 .081 Formaldehyde 000050 -00 -0 .0363 Nitric acid 007697 -37 -2 .45 Pseudocumene 000095 -63 -6 .4288 Sulfuric acid 007664 -93 -9 .45 Vinyl acetate 000108 -05 -4 .0907 Xylenes (o -, m -, p- isomers) 001330 -20 -7 .0402 Zinc Compounds RR- 00578 -7 3.9 National Volatile Organic Compound Emission Standards For Architectural Coatings: Volatile Organic Content: (gr/L) 10.86 g/1 WHMIS Classification(s): D2 B This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR). This MSDS contains all the information required by the CPR. State Regulatory Information: California Proposition 65: WARNING! This product contains substances known to the state of California to cause cancer, birth defects or other reproductive harm. www.graceconstruction.com Page 9 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS ID Number: Z -01569 MSDS Date: 11/05/2002 Massachusetts Hazardous Substance List(Identification threshold 0.001 %(lppm)): Chemical Name CAS # Wt % Acetaldehyde 000075 -07 -0 .0015 Acrylamide 000079 -06 -1 .0009 Acrylonitrile 000107 -13 -1 .0003 Ethyl acrylate 000140 -88 -5 .0024 Formaldehyde 000050 -00 -0 .0363 Nitric acid 007697 -37 -2 .45 Sulfuric acid 007664 -93 -9 .45 Vinyl acetate 000108 -05-4 .0907 New Jersey Hazardous Substance List(Identification threshold (0.1 %)): Chemical Name CAS # Wt Nitric acid 007697 -37 -2 .45 Pseudocumene 000095 -63 -6 .42 Sulfuric acid 007664 -93 -9 .45 Pennsylvania Hazardous Substance List(Identification threshold 0.01 %): Chemical Name CAS # Wt % — Formaldehyde 000050 -00 -0 .036 CHEMICAL INVENTORY STATUS: All chemicals in this product are listed or exempt from listing in the following countries: US CANADA EUROPE AUSTRALIA JAPAN KOREA PHILIPPINES TSCA DSL NDSL EINECS/ELINCS AICS ENCS ECL PICCS Yes Yes No Not Not Not Not Not Determined Determined Determined Determined Determined www.graceconstruction.com Page 10 of 11 11/19/02 W. R. GRACE MATERIAL SAFETY DATA SHEET Product Name: FlameSafe® FS 1900 Series Firestop Sealant MSDS ID Number: Z -01569 MSDS Date: 11105/2002 SECTION 16 - OTHER INFORMATION Non - Hazardous Ingredient Disclosure: Chemical Name CAS Number Water 007732 -18 -5 Prepared by: EH &S Department Approved by: EH &S Department Approved Date: 09/18/2000 Disclaimer: "The data included herein are presented in accordance with various environment, health and safety regulations. It is the responsibility of a recipient of the data to remain currently informed on chemical hazard information, to design and update its own program and to comply with all national, federal, state and local laws and regulations applicable to safety, occupational health, right -to -know and environmental protection." www.graceconstruction.com Page 11 of 11 11/19/02