HomeMy WebLinkAbout0100297-Building110 - New Single Family
Owner SHOWCASE CUSTOM HOMES INC
CITY OF OSHKOSH No 0100297
BUILDING PERMIT -APPLICATION AND RECORD
Create Date 02/03/2003
OSHKOSH
ON THE WATER
Job Address 4010 SHARRATT DR
Designer
Category
Contractor SHOWCASE CUSTOM HOMES INC
Type O Building O Sign O Canopy O Fence O Raze
Plan E1-007~0103R
Zoning R-1 Class of Const: 8
Unfinished/Basement 878 Sq. Ft. Rooms 3
Finished/Living 1658 Sq. Ft. Bedrooms 3
Garage 737 Sq. Ft. Baths 3
Foundation ~1 Poured Concrete (~) Floating Slab (~) Pier
(~ Concrete Block ~) Post O Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units I
Height 26 Ft.
Stories 2
Other
Size IRR
[] Projection1
Canopies 0
Signs 0
Height Permit Not Required
# Structures I
Use/Nature NSFR/2 story home with a 3 car attached garage, 12'x12' rear patio.
of Work
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By:
BREWER HEATING
SCHOMMER ELECTRICAL CON
$93,700.00 Plan Approval $75.00
Plumbing Contractor P&S PLUMBING
Permit Fee Paid
$362.00 Park Dedication $100.00
Date 03/19/2003 Final/O.P. 00/00/0000
[] Permit Voided
In the performance of this work I agr~ to perform all work pursuant to rules governing the described construction.
S,gnature '//~ .5'~'/~ ,i ' Date
- ~' t/ Agent/Owner
Address 2755 ALGOMA BLVD OSHKOSH WI 54901 - 0718 Telephone Number
235-5610/c-379-9046
OSHKOSH
ON THE WATER
Name SHOWCASE CUSTOM HOMES INC
Lot 58
GRADE STAKE FORM
Grade Stake Number 6892
Address 4010 SHARRATT DR Create Date 02/03/2003
Block Ward
Subdivision NORTH PARK ESTATES Zone
Street Number Lot Dimensions LJ_Sidewalk Existing ]
Building Grade Elevation Stakes Set At Site 0210312003 Set By D.W.G. BK - 586, P - 73
Department of Public Works
I, the undersigned, owner or agent of the above described propertY agree to have the grade established before excavation
has commenced. ~/].~X'~ ~'/~¢¢-~/,~_
Wisconsin Department of industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
WISCONSIN UNIFORM
BUILDING PERMIT
APPLICATION
Application No.
~97
[] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other:
Owner's Name
SHOWCASE CUSTOM HOMES IN£
Contractor: L~J ConE~ Bec[] HVAC bJ Plbg
SHOWCASE CUSTOM HOMES INC
Contractor: bJ Con [~J Elec b_J HVAC[~ Plbg
SCHOMMER ELECTRICAL CON
Contractor: ~ Con L_[ ElecL~ HVAC [] Plbg
BREWER HEATING
Contractor:b~ Con [] ElecE~ HVAC[~] Plbg
P&S PLUMBING
Lic/Cert #
2201
Lic/Cert #
170465
Lic/Cert #
4220
Lic/Cert #
Mailing Address
2755 ALGOMA BLVD Oshkosh
WI 54901- 0000
Mailing Address
2755 ALGOMA BLVD OSHKOSH
WI 54901 -718
Mailing Address
N 164 TWO MILE ROAD
APPLETON WI 54914 - 9121
Mailing Address
N8804 N DOUGLAS STREET RI PON WI 54971 -0
Mailing Address
PO BOX 2153 APPLETON WI 54913 - 0
Telephone No.
235-5610
Telephone No.
235-5610/c-379
Telephone No.
920)731-2299
Telephone No.
(920)748-6494
Telephone No.
734-3912
Lot Area
1/4, 1/4,Section ,T N,R
Building Address Subdivision Name Lot No.
4010 SHARRATT DR NORTH PARK ESTATES 58
i District(s) Permit No. Front Rear Left
E(or)W
Block No.
Right
New [] Repair Single Family Entrance Panel Forced Air Furnace Fuel
Two Family Size: 200am [] Radiant Baseboard or Panel
[] Alteration [] Raze
Garage Service: [] Heat Pump Space Htg
[] Addition [] Move [] Other (print): [] Overhead [] Boiler Water Htg
I E~ Other: [] Underground Central Air Conditioning Dwelling unit will have 3 kilowatt or
Other more installed electric space heating equip.
[] Site Constructed Concrete Infiltration control option is: [] Full sealing
Unfinished Manufactured Masonry Sewer of joints. [] Blower door test. [] Exterior
Treated Wood
Basement 878 Sq. ft. [] Municipal air infiltration barrier.
Living Area 1658 Sq. ft. 1-Story [] Septic
Garage 737 Sq. ft. [] 2-Story Permit No. Envelope 25703 BTU/HR
[] Other [] Seasonal Infiltration 15520 BTU/HR
[] Permanent [] Municipal Utility
[] Plus Basement [] Other [] Private On-Site Well $150,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, expres~ implied, on th~/Jl~part~ent or municipality; and certifies that all the above information/,,,-~ /_ ~is accurate.
APPLICANT'S SIGNATURE .~ ~/~,~// ~/_,/~__/__~-~ DATE SIGNED 03//XlO'~
~'- This p~rmit is isCed pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS revocation of this permit or other penalty
see standard conditions of approval
[] Town [] Village [] City [] County [~ State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 2 6 6
Plan Review $75.00 Construction
HVAC Name Nicole Krahn
Inspection ~J Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 2/3/03
Other [] Erosion
Total $105.00 --~ 275781 Cert. No. 248101
SBD-5823(R. 07/92)
OSHKOSH
ON THE WATER
Job Address
Name
Address
Subdivision
Building Permit Number
Number of Dwelling Units
Fee Required
PARKLAND DEDICATION FEE COLLECTION RECORD
4010 SHARRATT DR
SHOWCASE CUSTOM HOMES INC
2755 ALGOMA BLVD
NORTH PARK ESTATES
0100297
1
$100.00
Date 03/19~2003
Oshkosh WI 54901
Lot 58
Number of Structures
Fee Paid
Owner's Signature
Inspector's Signature
Date
Date
__--- 30-0' -'-'-~ 98A
5
GR,AV. EL ACCES~!V_E ~ ~ 10;/... ~ / ,/ 7,~
~ ~^x ~ ,OT ~,~ ~, ~ .~ ~./ ./~
~ A~ 4010 SHAR~ DR LOT 58 NPE ~ ~~
~ ~-~t SHOWCASE ~ (~) ~ "
Project Address
CITY OF OSHKOSH
STAND~CONDiTiONS'D~XP
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these Conditions. '
o
All habitable rooms must be provided with 8% light and 3.5% Ventilati0n~ -Bedrooms ..........
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be Separated froTM the-dwelling uni~ in-accordanc~- ;~ith iLHR 21.08.
-The door and frame assembly between the dwelling unit and an attached garage shall be' '
labeled by an independent testing agency' as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) ~d-b/i~k~d by'~01id Wobd~ ~ff .................................
drywall with the joints staggered.
All penetrations in exterior walls must be sealed prior to the insulation inspeCtion. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
Hydromassage tubg are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
Truss plans must be sUbmitted and approved p?i6r i0 framing the r$0f~
Truss plans including the truss layout must be provided on site at the rough building -
inspection. In addition to the truss plans, microlam calcUlations mUst be provided on site
at the rough building inspection for all micrOlams with Point loads on'them.
Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10.
11.
12.
13.
14.
15.
16.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained mil ~ h'.W~;i§..~'itablish¢~d.' -~
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end ofeachworkday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land.
development or disturbing activities.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the,inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum ora 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not alloWed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.