Loading...
HomeMy WebLinkAbout0140443-Electric (2000 amp outdoor service) Electric Permit Work Card Job Address 339 W 20TH AVE Permit Number 140443 Create Date 4/12/2010 Owner OSHKOSH CORPORATION Contractor BEEZ ELECTRIC INC Service New 0 Change° Temp 0 N/A Type 0 Overhead • Underground 0 N/A Volts 277/480 Circuits Luminaires Amps 2000 Switches Receptacles Value $35,000.00 Use /Nature JND / Installing new outdoor 2000 amp service. **debit acct of Work Inspections: Date 04/19/2010 Type Underground Inspector Kevin Benner approved Discussed driving the ground rods in lieu of laying them in the trench Date/Time requested: 04/19/2010 06:54 AM Notice Type: Ready Date/Time: 04/19/2010 11:00 AM Access: Eric Folsky will be on site Requested by: BEEZ ELECTRIC INC Phone Number: 379 -5601 Rob O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 04/29/2010 Type Service Inspector Kevin Benner approved w /cond. Inspection was requested to install a 400A disconnect on an existing buss duct. The electrical contractor is requesting that the utility • isconnect the service in leiu of shutting down the service disconnect. Because this installation is on the load sidethe service disconnect an inspection will not be required before the service is re- energized by the utility. Faxed to WPS 4/29/10 Date/Time requested: 04/29/2010 12:42 PM Notice Type: Ready Date/Time: 05/01/2010 12:00 PM Access: Requested by: BEEZ ELECTRIC INC Phone Number: 920 - 379 -5601 Rob Jones O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 05/28/2010 Type Service Inspector Kevin Benner approved REQUEST LINE / READY FOR A SERVICE INSPECTION Need confirmation from Sq.D that the MCB has a max. setting of 800A (2000A device) 65KAIC. Reviewed with Rob Jones & Eric Folsky. 44/10 12:10 PM Received confirmation of the MCB setting & Rob stated that hewould seal the cover over the adjusting means of the CB I immediately. APPROVED TO ENERGIZE. FAXED TO WPS 6/5/10. Scheduled for switch -over 6/6/10. Date/Time requested: 05/24/2010 03:21 PM Notice Type: Ready Date/Time: 05/28/2010 00:00 Access: Requested by: BEEZ ELECTRIC INC - Rob Phone Number: (920) 379 -5601 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid SQUARE D Schneider Electric 110 Packerland Drive, Suite C -2 Green Bay, WI 543 -4 y, 03 861 Phone (920) 494 -3313 Fax (859)- 372 -1830 May 27, 2010 RE: OSHKOSH TRUCK Shipping Building pp g Id ng 1901 Osborne Street Oshkosh, WI 54902 SUBJECT: SQUARE D FO #28179635 Hello, This is to confirm that the ground fault trip 9 on the Square D /PowerPact RK 2000AS /800AT utility breaker located within the service entrance switchboard was tested on 5/27/2010. The test was performed in accordance with NEC 230.95(C). With the ground fault trip set to .500 amperes on the breaker, 1000A of ground fault current was injected. The breaker properly tripped g P p Y PP ed due to the ground fault current in . 10,R seconds. Additionally, a Time Current Coordination Study was conducted to determine the optimum TCC settings of the type RK main circuit breaker. Results of the study are included with this document. The TCC dials on the RK main circuit breaker have been set based on the results of the TCC Study. Using the full function test kit S33595, it was determined that the microprosser based trip unit is operational and within calibration. Regards, SQUARE D COMPANY eiir�v a CW/ - RC 6 R. C. Batson Senior Executive Field Engineer • 1 UTIL -0001 CBL -0001 T ) PD -0001, MCB - SQUARE D RK Sensor/Trip 2000.0 A Settings LTPU /LTD (A 0.4 -1.0 x S) 0.4 (800A); 24 STPU (1.5 -10 x LTPU) 10 (8000A) STD (0 -0.4) 0.4 (I ^2t In) INST (2 -15 x S) 6 (12000A) y} PD -0003, 400A LC ) PD -0002, MCB GFP SQUARE D SQUARE D LC RG Sensor/Trip 400.0 A Sensor /Trip 1600.0 A Settings Settings Thermal Curve GFPU (500- 1200A) A (500A) INST HI (4000A) GFD (0 -0.4) 0.1 (I ^2t In) MDP 480 V Isc 3P 60188 A Project: OSHKOSH TRUCK SHIPPING BLDG 28179635 Scenario: Base Project LV Breakers Description Frame /Sensor /Plug Settings SQUARE D RK 2500.0A Phase Powerpact R- Framc, 6.OA /P /H 2000.0A LTPU /LTD (A 0.4 -1.0 x S) 0.4 (800A); 24 LSI, 600- 2500A, UL STPU (1.5 -10 x LTPU) 10 (8000A) STD (0 -0.4) 0.4 (1 ^21 In) INST (2 -15 x S) 6 (12000A) SQUARE D R 2 A Q G 500.0 Phase Powerpact R- Frame, 6.0A/P /H 1600.0A GFPU (500- 1200A) A (500A) GF, 1600- 2500AS, UL GFD (0 -0.4) 0.1 (1 ^21 In) SQUARE D LC 400.0A Phase LC 400.0A Thermal Curve 300 -600A INST HI (4000A) Page 1 CURRENT IN AMPERES 1000 ,, . O i tki k PD- 0001 % , MCB \ ► 1 1 S 100 0. PD -0002, MCB GFP c � • t i � � F.' \ . PD -0003, 400A LC X t 0- c, I 4`0 0 10 Co �y 4. ki o rn 1 % z 9 w rn o' r 0 �j � O 'e: Z 46 i w . a, i : yi:•i ii0a i• .�i� •i �+y i iOe �Oi ��� a %O � i• ; i (� 6•iiii0 O)••O a4� ` 0•4•ii►�• , ie'a04 ; 0.10 �iiligii 0 � i ai a�0°i i•�ii`%i i%•`a�•'�i,'O�'� iI aa0m$:4��•�o�s $::: 1: a te . . • • 0.01 �V 0.5 1 10 100 1K 10K 100K TCC OTC 28179635.tcc Ref. Voltage: 480V Current in Amps x 1