HomeMy WebLinkAboutCertificate of Occupancy - 02/24/2010 CITY HALL Inspection Services Div 215 Church Avenue City of Oshkosh PO Box 1130 Oshkosh WI 54903 -1130 OfHKOJH ON THE WATER Approved: February 24, 2010 Issued: February 24, 2010 Winnebago County P.O. Box 2808 Oshkosh, WI 54903 -2808 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby issued for the new Air Traffic Control Tower located at 3110 Knapp Street, Oshkosh WI as described in Building Permit #123939. This building shall be used as an Air Traffic Control Tower and is located in the M -3 General Industrial District. CONDITIONS: 1) Rough -in and above ceiling electrical inspections were not requested or conducted for the office areas. LIMITATIONS: Maximum number of persons: 35 NOTE: 1) Copies of inspection results are available upon request in room 205, City Hall. 2) Future permits may be required for additional work to your property. Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land, or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. Building Systems Inspector cc: Miron Construction BN /sms Electric Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 134859 Create Date 1/27/2009 Owner WINNEBAGO COUNTY Contractor SCHINDLER ELEVATOR CORPORATIOI` Service 0 New 0 Change° Temp • N/A Type 0 Overhead 0 Underground • N/A Volts Circuits Luminaires Amps Switches Receptacles Value $1,500.00 Use /Nature 642 - Commercial -New Building Wiring COMM / WIRING ASSOCIATED WITH THE ELEVATOR IN THE AIR TRAFFIC of Work CONTROL TOWER * *check #2494134, 2497076 Inspections: Date 07/03/2008 Type Final Inspector Kevin Benner not approved field request from the Omni & Assoc. Tim Bolwerk Date/Time requested: 07/03/2008 00:00 AM Notice Type: FC Ready Date/Time: 07/03/2008 00:00 AM Access: Requested by: OMNI & ASSOC Phone Number: 830 -6150 Tim 0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 07/28/2008 Type Re Final Inspector Kevin Benner not approved Proper sized wire terminals, green equipment grounding conductors, Firestopping from the hoistway to the elevator closet, work space for the panel, electric permit Date/Time requested: 07/22/2008 01:01 PM Notice Type: Ready Date/Time: 07/23/2008 07:00 AM Access: Requested by: OMNI & ASSOC Phone Number: 830 -6150 Tim 0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 12/02/2009 Type Re Final Inspector Kevin Benner The conditions of the approval are: Tim stated that he and the PM from Miron Const corrected the firestop installation per the submitted drawings. Reviewed with Tim Bolwerk & Brian Noe (Building Inspector) Date/Time requested: 11/25/2009 08:35 AM Notice Type: Ready Date/Time: 12/02/2009 10:02 AM Access: Requested by: Omni Engineering - Tim Bolwerk Phone Number: 830 -6150 Tim 0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 124400 Create Date 4/20/2007 Owner WINNEBAGO COUNTY Contractor NORTHERN ELECTRIC INC Service New 0 Change 0 Temp 0 N/A 1 Type 0 Overhead • Underground 0 N/A_ Volts Volts 120/208 Circuits Luminaires Value $400,000.00 Amps 600 Switches Receptacles Use /Nature 642 - Commercial -New Building Wiring COMM / Wire new air traffic control tower. of Work Inspections: Date 11/14/2007 Type Service Inspector Adam Krause approved IC Rating on fuses 200K, 57K available at X -frmr Faxed approval to WPS 11 -14 -2007 10:45 AM Date/Time requested: 11/13/2007 08:44 AM Notice Type: Ready Date/Time: 11/13/2007 08:44 AM Access: Requested by: NORTHERN ELECTRIC INC Phone Number: O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 03/25/2008 Type Service Inspector Kevin Benner not approved Fire Pump FCN notice plus these items were reviewed with Mike: Bonding bushing conductor size to be #6, Bonding jumper in the etersocket, Arc Flash Warning Labels, Grounding from the water. ID "Fire Pump Disconnecting Means" in 1" letters. Date/Time requested: 03/20/2008 02:47 PM Notice Type: FC Ready Date/Time: 03/20/2008 02:47 PM Access: Requested by: NORTHERN ELECTRIC INC Mike Phone Number: O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 05/01/2008 Type Re Service Inspector Kevin Benner approved w /cond. Fire Pump • II violations have been corrected except the labels are not on site yet. FAXED TO WPS 5/1/8 Noted that a chiller required working space for the control panel. FCN left on site. Date/Time requested: 04/24/2008 12:36 PM Notice Type: FC Ready Date/Time: 04/28/2008 00:00 AM Access: Requested by: NORTHERN ELECTRIC INC _ Phone Number: 371 -5027 Mike O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 05/02/2008 Type Abv Ceiling Inspector Kevin Benner approved w /cond. op Floor: Fireproofing to be repaired where the electrical was attached to the structure, pen box for the locating beacon to be installed on the roof. Noted violations on the floor below the top that were reviewed with ike:Dedicated space above the electrical panel, parallel wire terminations on bonding lug(s), , CL2 & pwr wiring seperation in the HVAC anel Date/Time requested: 05/01/2008 10:48 AM Notice Type: Ready Date/Time: 05/01/2008 10:48 AM Access: Requested by: NORTHERN ELECTRIC INC Phone Number: 371 -5027 Mike O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 124400 Create Date 4/20/2007 Owner WINNEBAGO COUNTY Contractor NORTHERN ELECTRIC INC Service 0 0 Change ❑ Temp ❑ N/A 1 Type 0 Overhead • Underground O N/A Volts 120/208 Circuits Luminaires Amps 600 Switches Receptacles Value $400,000.00 Use /Nature 1642 - Commercial -New Building Wiring COMM / Wire new air traffic control tower. of Work Inspections: Date 06/26/2008 Type Consultation Inspector Kevin Benner approved enerator & Fire Pump Test old Start & transfer was 8.73 sec. Hot start & transfer was 5.94 sec. Date/Time requested: 06/23/2008 01:53 PM Notice Type: Ready Date/Time: 06/26/2008 10:00 AM — — Access: Requested by: Fire Dept Grizwald Phone Number: O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 06/30/2008 Type Final Inspector Kevin Benner not approved In addition to the violations that were noted on the FCN underground, rough -in and above ceiling inspections were not requested or conducted. Flag pole lights will not be installed until the site work is complete. The elevator electrical inspection was not conducted because t he elevator inspector was conducting his inspection at the time of electrical inspection and 1 could not access the equipment. Date/Time requested: 06/23/2008 12:10 PM Notice Type: FC Ready Date/Time: 06/30/2008 10:00 AM Access: Requested by: NORTHERN ELECTRIC INC Phone Number: 468 -7000 Bill O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date Type Re Final Inspector Kevin Benner EC's portion of the FCN only Date/Time requested: 07/01/2008 02:46 PM Notice Type: Ready Date/Time: 07/01/2008 02:46 PM Access: Requested by: NORTHERN ELECTRIC INC Phone Number: 371 -5027 Mike O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 07/23/2008 Type Re Final Inspector Kevin Benner not approved All electrical also to include the FAA violations Chiller platform not correct, dedicated space sheild not installed panel "Cu, Date/Time requested: 07/21/2008 02:28 PM Notice Type: Ready Date/Time: 07/21/2008 02:28 PM Access: Call Brian Chitam 224 - 723 -9567 Requested by: NORTHERN ELECTRIC INC Bill Phone Number: 468 -6000 O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 124400 Create Date 4/20/2007 Owner WINNEBAGO COUNTY Contractor NORTHERN ELECTRIC INC Service New O Change Q Temp O N/A Type O Overhead • Underground 0 N/A Volts 120/208 Circuits Luminaires Amps 600 Switches Receptacles Value $400,000.00 Use /Nature 1642 - Commercial -New Building Wiring COMM / Wire new air traffic control tower. of Work Inspections: Date 09/29/2009 Type Re Final Inspector Kevin Benner approved w /cond. The condtions of the approval are: There were not rough or above ceiling inspections requested or conducted. Requested fire- stopping submittals for the elevator hoistweay electrical penetrations and the shaft penetrations for the cabling installation for the FAA low voltage equipment. Reviewed with Tim Bolwerk. Date/Time requested: 09/24/2009 08:59 AM Notice Type: Ready Date/Time: 09/29/2009 09:30 AM Access: Requested by: Omni Engineering - Tim Bolwerk Phone Number: 830 -6150 Tim O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 12/02/2009 Type Consultation Inspector Kevin Benner not approved Email Request Reviewd the fire stopping for the elevator and the FAA installations. Tim Bolwerk stated that he would not assist in gaining compliance with I the FAA installations other than contact information. Date/Time requested: 11/25/2009 08:35 AM Notice Type: Ready Date/Time: 12/02/2009 10:05 AM Access: Meet on site Requested by: Omni Engineering - Tim Bolwerk Phone Number: 830 -6150 Tim O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 01/20/2010 Type Re Final Inspector Kevin Benner approved w /cond. Rough -in and above ceiling inspections were not requested or conducted for the office areas Date/Time requested: 01/15/2010 11:06 AM Notice Type: Ready Date/Time: 01/20/2010 11:00 AM Access: Requested by: Omni Engineering - Tim Bolwerk Phone Number: 830 -6150 Tim O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 131779 Create Date 7/23/2008 Owner WINNEBAGO COUNTY Contractor NORTHERN ELECTRIC INC Service New 0 Change 0 Temp • N/A Type 0 Overhead 0 Underground • N/A Volts Circuits Luminaires Amps Switches Receptacles Value $8,500.00 Use /Nature 2 - Commercial -New Building Wiring Low Voltage wiring associated with the Air Traffic Control Tower * *check #62588 of Work Inspections: Date 07/23/2008 Type Consultation Inspector Kevin Benner Field Request Reviewed the wiring that is presently installed. Additional wiring will be installed after EAA when equipment can be relocated from the old tower. No Firestopping was installed. Date/Time requested: 07/23/200800:00 AM Notice Type: Ready Date/Time: 07/23/2008 00:00 AM Access: Requested by: OMNI & Assoc. Phone Number: 830 -6150 Tim O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 09/29/2009 Type Final Inspector Kevin Benner not approved Firestopping was not installed. — Date/Time requested: 09/24/2009 08:57 AM Notice Type: Ready Date/Time: 09/29/2009 09:30 AM Access: Requested by: Omni Engineering - Tim Bolwerk Phone Number: 830 -6150 Tim Bolwerk O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 12/02/2009 Type Final Inspector Kevin Benner not approved Fire stopping does not match the systems that were submitted Date/Time requested: 11/25/2009 08:35 AM Notice Type: Ready Date/Time: 12/02/20 10:00 AM Access: Requested by: Phone Number: O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Date 01/13/2010 Type Consultation Inspector Kevin Benner CN Discussed how to correct his installations and the tower floor penetration inspection to be done. 1/14/10 Emailed the E.C. to procure firestopping submittals for the floor penetrations. Date/Time requested: 01/07/2010 09:58 AM Notice Type: Ready Date/Time: 01/13/2010 10:0 A M Access: Meet Scott on site Requested by: FAA Phone Number: 608 - 244 -4148 Scott O Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Electric Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 131779 Create Date 7/23/2008 Owner WINNEBAGO COUNTY Contractor NORTHERN ELECTRIC INC Service a New 0 Change° Temp • N/A j Type 0 Overhead 0 Underground • N/A Volts Circuits Luminaires Amps Switches Receptacles Value $8,500.00 Use /Nature 642 - Commercial -New Building Wiring Low Voltage wiring associated with the Air Traffic Control Tower * *check #62588 of Work Inspections: Date 01/20/2010 Type Consultation Inspector Kevin Benner approved Date/Time requested: 01/15/2010 11:06 AM Notice Type: Ready Date/Time: 01/20/2010 11:00 PM Access: Requested by: FAA Phone Number: 608 - 807 -7407 Scott Sherer 0 Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 7/2/2008 Type Final Inspector Allyn Dannhoff not approved See e-mail dated 7/8/08. Date/Time requested: Notice Type: Ready Date/Time: • Access: Requested By: Phone Number: O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 7/22/2008 Type Final Inspector Allyn Dannhoff approved Date/Time requested: • Notice Type: Ready Date/Time: • Access: Requested By: Phone Number: O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 5 of 5 Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 6/19/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time Request line / Pouring slab on grade Thurs & Fri, 6/21 & 6/22 Date/Time requested: 6/19/2007 08:32 AM Notice Type: Ready Date/Time: 6/21/2007 Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 969 -7696 O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 12/20/2007 : Type Rough In Inspector Allyn Dannhoff approved REQUEST LINE / READY FOR A FRAMING INSPECTION - WOULD LIKE TO SHEET ROCK FRIDAY 12/14/07 PLEASE CALL ERIC HE WOULD LIKE TO BE PRESENT FOR THE INSPECTION RI and Insulation - No concerns noted. Need to research wiring methods for floor /air supply cabinets in the control cab. Spoke to Eric on 12/21/07 - No different requirements between return & supply plenums. Date/Time requested: 12/12/2007 03:13 PM Notice Type: Ready Date/Time: 12/12/2007 03:13 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: (920) 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 1/25/2008 Type Consultation Inspector Allyn Dannhoff no time REQUEST LINE / READY FOR AN ABOVE CEILING INSPECTION TO LOOK AT THE VARIOUS MECHANICALS AND THE CAB ACCESS AREA. Talked to Jerry and told him I would not be able to make inspection. Date/Time requested: 1/24/2008 08:42 PM Notice Type: Ready Date/Time: 1/30/2008 00:00 Access: ONSITE 7A -330P Thru the gate to the temporary wood door Requested By: MIRON CONSTRUCTION CO INC - Jerry Phone Number: (920) 969-7624 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 4/30/2008 : Type Final Inspector Allyn Dannhoff approved w /cond. REQUEST LINE / WOULD LIKE A BUILDING GENERAL INSPECTION (FINAL ?). PRE -FINAL Advised Michael Schmid, PM, handrails in stairs must be continuous. Date/Time requested: 4/17/2008 10:38 AM Notice Type: Ready Date/Time: 4/24/2008 00:00 AM Access: Enter through the hollow metal doors on the east or west side of the tower (doors open from 7am -330p Monday - Friday) I Requested By: MIRON CONSTRUCTION CO INC - Jerry Phone Number: (920) 969 -7624 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 4of5 Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 5/23/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time Request line / Pouring foundation walls at 2:OOpm Date/Time requested: 5/22/2007 11:57 AM Notice Type: Ready Date/Time: 5/23/2007 Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: Q Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/25/2007 Type Footings Inspector Allyn Dannhoff no time Request line / Pouring interior footings at 2:OOpm Date/Time requested: 5/23/2007 12:19 PM Notice Type: Ready Date/Time: 5/24/2007 02:00 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: none given Q Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Date 5/25/2007 Type Footings Inspector Allyn Dannhoff no time Request line / Pouring interior footings on Tues 5/29 — , Date/Time requested: 5/25/2007 11:33 AM Notice Type: Ready Date/Time: 5/29/2007 Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 Q Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Date 5/31/2007 Type Foundation Backfill Inspector Allyn Dannhoff no tim Request line / Pouring interior foundation at 2:00 Thurs & Fri 5/31 & 6/1 Date/Time requested: 5/30/2007 02:00 PM Notice Type: Ready Date/Time: 5/31/2007 02:00 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 969 -7696 Q Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 3 of 5 Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 5/15/2007 Type Footings Inspector Allyn Dannhoff no time Request line / Pouring at 1:30 Date/Time requested: 5/15/2007 09:49 AM Notice Type: Ready Date/Time: 5/16/2007 01:30 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/17/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time REQUEST LINE / POURING THE FOUNDATION WALL AT 1:30 ON 5/17/07 I I I Date/Time requested: 5/16/2007 11:21 AM Notice Type: Ready Date/Time: 5/16/2007 11:21 AM Access: Requested By: MIRON CONSTRUCTION - ERIC WELLHOUSE Phone Number: (920) 969 -7969 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/21/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time REQUEST LINE / READY FOR A BACKFILL INSPECTION ON THE FOUNDATION WALLS AND YOU CAN CHECK THE INSULATION - WILL BE POURING MORE FOUNDATION WALLS ON MONDAY 5/21/07 AT 1:30PM Date/Time requested: 5/18/2007 09:26 AM Notice Type: Ready Date/Time: 5/18/2007 09:26 AM Access: Requested By: MIRON CONSTRUCTION CO INC - ERIC Phone Number: (920) 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/21/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time Request line Date/Time requested: 5/21/2007 11:04 AM Notice Type: Ready Date/Time: 5/22/2007 01:30 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 2 of 5 Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date Type Foundation Backfill Inspector Allyn Dannhoff Phone call to Allyn - Pouring mud slab on Wed. 5/2 and rebar pourings the rest of the week. Date/Time requested: 4/30/2007 01:59 PM Notice Type: Ready Date/Time: 5/2/2007 : PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 Q Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 5/10/2007 : AM Type Foundation Backfill Inspector Allyn Dannhoff approved Phone call to Allyn - Will pour the tower slab on Tues. 5/9. Will call before to confirm the pour. No concerns noted (tower base). Base is poured - discussed details with Eric. Date/Time requested: 4/30/2007 01:59 PM Notice Type: Ready Date/Time: 5/9/2007 : PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 910 - 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date Type Note Inspector Allyn Dannhoff UPDATE: Will pour tower base Tues morn 5/9 and some backfilling and excavating. Friday will do backfilling and Monday 5/14 excavating for 4' frost walls. • Date/Time requested: 5/7/2007 : AM Notice Type: Ready Date/Time: Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 Q Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date Type Footings Inspector Allyn Dannhoff REQUEST LINE / READY FOR A FOOTING INSPECTION **WILL POUR TOMORROW 5/15/07 AT 1:30PM ** Date/Time requested: 5/14/2007 09:28 AM Notice Type: Ready Date/Time: 5/14/2007 09:28 AM Access: Requested By: MIRON CONSTRUCTION CO INC - ERIC Phone Number: (920) 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 1 of 5 HVAC Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 124615 Create Date 05/03/2007 Owner WINNEBAGO COUNTY Contractor AUGUST WINTER & SONS INC Fuel U Gas ! J Oil u Electric u Solar U Solid Value $200,000.00 System Ff New Replace n Other u Forced Air ❑ Radiant a Steam LJ NC ❑ Vent ❑ Electric ❑ Hot Water u Suppl. ❑ Con. Burner Chimney Type ❑ Chimney A 0 Chimney B O Direct Vent • Not Applicable Use /Nature Install HVAC system for new Air Traffic Control Tower Facility. 1 of Work Inspections: Date 7/22/2008 Type Final Inspector Allyn Dannhoff approved Date/Time requested: Notice Type: Ready Date/Time: • Access: Requested By: Phone Number: 0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Plumbing Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 125208 Create Date 05/16/2007 Owner WINNEBAGO COUNTY Contractor S &S MECHANICAL Category 440 - Industrial- Interior Plan Value $49,719.00 Bathtub Shower Water Softner Wait. St. Shamp Sink Coffee Maker Whirlpool Floor Drain 4 Local Waste Ice Chest Flr/Wst Sink 2 Int Grease Trap Lavatory 3 Lndry Tray Clothes Wshr Exam Sink Catch Basin Ext Grease Trap Toilet 3 Disposal Bidet Sculry Sink Wash Ftn RPZ Valve 2 Res. Sink 2 Dishwasher 0 Beer Tap Hand Sink Urinal 1 Eye Wash Statn Bar Sink Sump Pump 1 Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs Water Heater 3 Classrm Sink Sterilizer Surgeons Sink Ice Maker Deduct Meters Site Drain Breakrm Sink 0 Dip Well F Prep Sink Gar Drain Wtr Usage Mtrs - 1 Roof Drain _ 10 Ejector /Grind Drink Ftn 1 Sery Sink 1 Soda Disp Misc. 5 4 3/4" silcock, 1 PRV Fixtures Use /Nature Interior plumbing for new Airport Tower. State completed plan review. Tank type electric water heater and point-of-use water heater to of Work be installed. Trap primer valves to comply with COMM 82.41. Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Inspections for Work Card 92063 Date 6/15/2007 Type Underground Inspector Paul Wolf approved w /cond. Vent stack shall be installed per COMM 82.31. Date/Time requested: 6/14/2007 07:28 AM Notice Type: FC Telephone Number: Access: Ready Date/Time: 6/14/2007 07:28 AM Requested By: S &S MECHANICAL O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 6/27/2007 Type Rough In Inspector Paul Wolf approved Restroom carriers set. Date/Time requested: 6/27/2007 09:54 AM Notice Type: Telephone Number: Access: Ready Date/Time: 6/27/2007 09:54 AM Requested By: S &S MECHANICAL O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 8/1/2007 Type Rough In Inspector Paul Wolf approved Started water piping. Date/Time requested: 8/1/2007 08:57 AM Notice Type: Telephone Number: Access: Ready Date/Time: 8/1/2007 08:57 AM Requested By: S &S MECHANICAL O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 12/18/2007 Type Rough In Inspector Paul Wolf approved w /cond. ;Requested water calc sheet from plumber to determine distribution sizing serving tower. Date /Time requested: 12/18/20007:51 AM Notice Type: Telephone Number: Access: Dean 375 -3454 Ready Date/Time: 12/18/200 07:51 AM Requested By: S &S MECHANICAL O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Inspections for Work Card 92063 Date 6/26/2008 Type Final Inspector Paul Wolf not approved RPZ valve serving boiler shall be tagged and tested with report filed and SS not permitted to receive condensate from HVAC equipment. Only 1 RPZ valve installed, not 2 as permit indicates. Date /Time requested: 6/26/2008 07:25 AM Notice Type: FC Telephone Number: Access: Ready Date/Time: 6/26/2008 07:25 AM Requested By: S &S MECHANICAL O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 7/8/2008 Type Re Final Inspector Paul Wolf approved [ fest report filed for RPZ. I Date/Time requested: 7/8/2008 08:43 AM Notice Type: Telephone Number: Access: Ready Date/Time: 7/8/2008 08:43 AM Requested By: S &S MECHANICAL 0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid 0 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH i.� DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 12/21/2009 Compliance Date 1/20/2010 IMMEDIATELY Compliance No Address 3110 -3130 KNAPP ST Name Address City State Zip Code Sent to ✓f Owner WINNEBAGO COUNTY PO BOX 2808 OSHKOSH WI 54903 -2808 ✓� Required for Occupancy Occupancy Commercial Introduction hile conducting a routine inspection the following violations were noted. The violations are in reference to the FAA's portion •f the Low Voltage wiring associated with the Air Traffic Control Tower Permit # 131779 Item # 1 Code NEC 300.21 Compliance No Compliance Date 01/20/2010 IMMEDIATELY Description Openings around electrical penetrations through fire- resistant -rated walls, partitions, floors, or ceilings shall be firestopped using approved methods to maintain the fire resistance rating. 12/21/2009 Last Updated Summary To avoid any further inconvenience, please correct the above noted violations immediately. Any quest or concerns please feel free to contact me @ 920 - 236 -5046 or Brian Noe @ 920 -236 -5051 Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 1/20/2010 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. Signature Date Inspected by: Kevin Benner 236 -5046 kbenner @ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Bldg — 1 MIRON CONSTRUCTION CO INC PO BOX 509 NEENAH WI 54957 -509 IJ Elec NORTHERN ELECTRIC INC 314 N DANZ AVE GREEN BAY WI 54302 -3526 Lf HVAC U Plbg — - - u Designer j Other , - - - ✓ Inspector P j Brian Noe 15787 Page 1 of 1 Page 1 of 2 Noe, Brian From: Benner, Kevin Sent: Monday, December 21, 2009 8:42 AM To: Tim Bolwerk Cc: Noe, Brian Subject: RE: Letter from city of Oshkosh Hi Tim, Sorry I was not able to get back to you sooner, but I was really busy Thursday and Brian & I were both off work on Friday. With the short notice, no other arrangements could be made for someone else to conduct the inspection. Brian & I will still need to get in the tower to inspect the installation which you and Mike did on Friday. A correction notice will be sent to Northern Electric because they procured the permit for the installation and the airport will be copied. Did the elevator contractor meet you on site to position the elevator car for you to use as work platform? Happy Holidays! Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Thursday, December 17, 2009 9:17 AM To: Benner, Kevin Cc: terry.ripp @dot.wi.gov; PMoll @co.winnebago.wi.us Subject: FW: Letter from city of Oshkosh Kevin — Do you know if a correction notice was going to be sent out on the fire wall penetration from the Equipment Room in the base building of Wittman Tower to the Communication Chase in the tower? This notice would need to be sent to Peter Moll at the airport, but the work would be done by FAA. I will need this notice to forward on to FAA so I have something to get them back to do the work. As far as the penetration from the elevator equipment room into the hoist way, Mike Schmid from Miron and I will be down on site tomorrow, Friday, to redo this penetration per the detail from Hilti. We are planning on being there around 8:00 and working on it until it is complete. Any questions, please let me know. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 12/21/2009 Page 2 of 2 From: Ripp, Terry - DOT [mailto:Terry.Ripp ©dot.wi.gov] Sent: Wednesday, December 16, 2009 2:47 PM To: Tim Bolwerk Subject: Letter from city of Oshkosh Tim, Peter has NOT received a letter yet from the City Inspector for the tower. I asked him when he did, if it was in the next 2 weeks to make sure that you knew about it. If you get anything from him and you have time to contact FAA, fine otherwise, it will wait until I get back. Actually, I think Ron Hubrich is on vacation until after the first of the year also, so I don't know if it pays to do anything or not. Please note new e-mail address: terry.ripp@dot.wi.gov Terry J. Ripp Bureau of Aeronautics P.O. Box 7914 Madison, WI 53707 -7914 608 - 267 -7108 phone 608 - 267 -6748 FAX www.dot.wisconsin.gov /modes /air.htm This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com /legal /OMNNI_Email_Disclaimer.pdf 12/21/2009 Page 1 of 2 Noe, Brian From: Benner, Kevin Sent: Thursday, December 17, 2009 12:14 PM To: Noe, Brian Subject: FW: Letter from city of Oshkosh Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Thursday, December 17, 2009 9:17 AM To: Benner, Kevin Cc: terry.ripp @dot.wi.gov; PMoll @co.winnebago.wi.us Subject: FW: Letter from city of Oshkosh Kevin — Do you know if a correction notice was going to be sent out on the fire wall penetration from the Equipment Room in the base building of Wittman Tower to the Communication Chase in the tower? This notice would need to be sent to Peter Moll at the airport, but the work would be done by FAA. I will need this notice to forward on to FAA so I have something to get them back to do the work. As far as the penetration from the elevator equipment room into the hoist way, Mike Schmid from Miron and I will be down on site tomorrow, Friday, to redo this penetration per the detail from Hilti. We are planning on being there around 8:00 and working on it until it is complete. Any questions, please let me know. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Ripp, Terry - DOT [mailto:Terry.Ripp @ dot.wi.gov] Sent: Wednesday, December 16, 2009 2:47 PM To: Tim Bolwerk Subject: Letter from city of Oshkosh Tim, Peter has NOT received a letter yet from the City Inspector for the tower. I asked him when he did, if it was in the next 2 weeks to make sure that you knew about it. If you get anything from him and you have time to contact FAA, fine otherwise, it will wait until I get 12/17/2009 Page 2 of 2 back. Actually, I think Ron Hubrich is on vacation until after the first of the year also, so I don't know if it pays to do anything or not. Please note new e-mail address: terry.ripp@dot.wi.gov Terry J. Ripp Bureau of Aeronautics P.O. Box 7914 Madison, WI 53707 -7914 608- 267 -7108 phone 608 - 267 -6748 FAX www. dot .wisconsin.gov /modes /air.htm This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http://www.omnni.com/legal/OMNNI_Email_Disclaimer.pdf 12/17/2009 Page 1 of 1 Noe, Brian From: Benner, Kevin Sent: Tuesday, December 08, 2009 10:48 AM To: Tim Bolwerk Cc: Noe, Brian Subject: RE: Wittman Tower Hi Tim, Thanks for the update. Could you please keep me in the loop as to when the penetration is to be corrected so that we have an opportunity to inspect it as it is being installed? Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 _ City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Tuesday, December 08, 2009 8:03 AM To: Benner, Kevin; Michael .Schmid @Miron - Construction.com Cc: PMoll @co.winnebago.wi.us; terry.ripp @dot.wi.gov Subject: Wittman Tower Kevin — Attached to this e-mail is a detail we received from Hilti for sealing up the firewall penetration and providing a two hour fire rating from the elevator equipment room to the hoistway. I will work directly with Mike Schmid from Miron to get this taken care of and documented. As far as the firewall penetrations from the main level equipment room to the communication chase that had been done by FAA, please send out a correction notice to Peter Moll at Wittman Regional Airport. FAA will correct this penetration, but the notice will need to be sent to the Owner of the tower. If you have any questions or comments, please let me know. Thanks! Mike — Give me a call so we can discuss some times that might work to take care of the penetration in the elevator control room. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com/ legal /OMNNI_Email_Disclaimer.pdf 12/8/2009 DI IR ENGINEERING JUDGMENT FIRESTOP DETAIL PROJECT : A000-A09 -2 HOUR FIRE WALL OPENING CONTRACTOR : OMNNI ASSOCIATES F-RATING = 2-HR. FRONT VIEW SECTION A-A N, * .. • ...... . . . . .,. . . . 0 . . .. V *4 . ' • ' * . • 4 . * 4 , i . 4 . A/ 4 • . 00fr 0000r — ,..., . . • • 0, . • • • • • • . • . • • • • • • • * 0 0, 4 " • eill1.404001°° . . 411111111111111111t 4 . - .. Adler 41110 . Al, ' 4 OP „,-.• ,......0 1 10 AO , .. • • • 0 4 41 III 0 1. CONCRETE WALL ASSEMBLY (MINIMUM 5" THICK) (2-HR. FIRE-RATING) 2. MAXIMUM 2" x 4" SOLID/ENCLOSED STEEL WIRE WAY (MIN. 16 GA.) (MAX. QTY. = 2). 3. MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED, RECESSED TO ACCOMMODATE SEALANT. 4. MINIMUM 112" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. NOTES :1. MAXIMUM SIZE OF OPENING = 12" x 12". • 2. ANNULAR SPACE = MINIMUM 1/2", MAXIMUM 8". _ ...._ , THIS ENGINEER/1G JUDGMENT REPRESENTS A FIRESTOP SYSTEM THAT WOULD BE EXPECTED TO PASS THE STATED RATNGS IF TESTED. (REFERENCE : UL SYSTEM NO. C-AJ-8099 & C-AJ-8143) HILTI, Inc. 1 Sheet 1 of 1 Drawing No Tulsa, Oklahoma USA (800) 879 Scale 9164" = 1" 4 A ay , Designed by ......7 4 4„,„,,, D I 1011 8a Hilt' Firestop Systems Dec. 07 , 2009 Saving Lives through innovation and Education Page 1 of 1 Noe, Brian From: Benner, Kevin Sent: Tuesday, December 08, 2009 10:49 AM To: Noe, Brian Subject: FW: Wittman Tower Attachments: firestop _detail_elevator_room.pdf Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Tuesday, December 08, 2009 8:03 AM To: Benner, Kevin; Michael .Schmid @Miron - Construction.com Cc: PMoll @co.winnebago.wi.us; terry.ripp @dot.wi.gov Subject: Wittman Tower Kevin — Attached to this e-mail is a detail we received from Hilti for sealing up the firewall penetration and providing a two hour fire rating from the elevator equipment room to the hoistway. I will work directly with Mike Schmid from Miron to get this taken care of and documented. As far as the firewall penetrations from the main level equipment room to the communication chase that had been done by FAA, please send out a correction notice to Peter Moll at Wittman Regional Airport. FAA will correct this penetration, but the notice will need to be sent to the Owner of the tower. If you have any questions or comments, please let me know. Thanks! Mike — Give me a call so we can discuss some times that might work to take care of the penetration in the elevator control room. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com /legal /OMNNI_Email_Disclaimer.pdf 12/8/2009 Page 1 of 1 Benner, Kevin From: Tim Bolwerk [Tim.Bolwerk @omnni.com] Sent: Saturday, November 21, 2009 2:16 PM To: Benner, Kevin Cc: terry.ripp @dot.wi.gov; Michael .Schmid @Miron- Construction.com; tim.marty@wi.gov Subject: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower Attachments: Fire stop system.pdf Kevin — I have reattached the detail that was forwarded to you in our last correspondence regarding this penetration. I have contacted Miron Construction on this detail and Miron Construction has contacted Schindler elevator on the detail. While this detail may not fit the attached detail exactly, it is the nearest Hilti detail that could be found for the application by the contractor. What was installed, per Mike Schmid at Miron, was the wireway was packed with steel wool as per the drawing, and then a sheet metal enclosure was installed to contain the steel wool. The fire caulk was applied over and around the sheet metal enclosure. I did touch bases with the state elevator inspector, Tim Marty, and he indicated that as part of his inspection, before issuing an elevator use permit, he does review not only all the elevator components and operation, but also the fire wall penetrations. Mr. Marty indicated that if he had noted any concerns with this particular penetration, he would have noted the concern on his report. He did indicate he was satisfied with the installation of this penetration at the time of his inspection. He also indicated that the State Elevator Inspector would have jurisdiction over this installation, but suggested that if you had further concerns, that you could give him a call. We would just ask that you contact Mr. Marty to discuss to see if there can be some agreement on this penetration. While we are not looking to circumvent anyone's concerns regarding any portion of this project, we are mostly interested in getting the job complete and obtaining the official occupancy permit for this project. If you are not satisfied with either detail on the remaining fire penetrations in question or are not interested or will not discuss the elevator hoistway penetration with Mr. Marty or have discussed and would still have some action item, we would just ask that you provide some direction on what you would like to see done. Again, we are just looking to close the project out but we also want to close the project out in compliance with codes and requirements. Thanks Kevin! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com/ legal /OMNNI_Email_Disclaimer.pdf 12/2/2009 Page 1 of 2 Noe, Brian From: Benner, Kevin Sent: Monday, November 23, 2009 7:06 AM To: Noe, Brian Subject: FW: Wall Fire Rating Clarification Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenr?er @ci.oshkosh.wi.us Fro : Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] _ Sent S aturday, November 21, 2009 12:54 PM To: n ner, Kevin Sub : RE: Wall Fire Rating Clarification Than s Kevin! I will be sending two additional e-mails to you regarding the firewall penetrations with the information I was able to gathe from both FAA and Miron /Schindler. The FAA's detail, I believe, is correct. For the detail on the penetration in the elevator equipment room /hoistway, Miron /Schindler had a more difficult time supplying the detail and referred me to the elevator inspector. Anyway, I will discuss these in separate e- mails. Thanks Again! Tim B Iwerk, P.E. OMN I Associates, Inc. One ystems Drive Apple WI 54914 Phon (920) 830 -6150 Fax ( 20) 830 -6100 From Benner, Kevin [mailto:kbenner @ci.oshkosh.wi.us] Sent: Friday, November 20, 2009 1:23 PM To: Ti Bolwerk Subj : RE: Wall Fire Rating Clarification Hi Tirrj, Sorry for the delay, Brian Noe reviewed the letter from the designer and he concurred with his explanation. Now we need the fire stoppi g details which match the installation. Sorry i or any inconvenience. If you have any questions or concerns please feel free to contact me. Have a great weekend, Kevin enner Electri Ilnspector City of Oshkosh 215 C urch Ave PO Bo 1130 I 11/232009 Page 2 of 2 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Monday, November 09, 2009 7:49 AM To: Benner, Kevin Cc: terry.ripp @dot.wi.gov; PMoll @co.winnebago.wi.us; Michael .Schmid @Miron - Construction.com Subject: Wall Fire Rating Clarification Kevin — Attached is a letter from the Architect of Record regarding the required fire ratings on the walls in question at Wittman Tower. Based on our last conversation, there was a question on what the applicable wall fire ratings were based on what was in the plans. These wall fire ratings were being questioned as there were two penetrations through fire walls in which we were looking at what was required as far as sealing the penetrations in compliance with UL fire systems. Anyway, please review the letter and if you have any questions, please let me know. If you need a hard copy of the letter, please let me know. If this letter is OK, I will work on getting you the two hour details used at the two locations in question. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 - Phone (920) 830 -6150 Fax (920) 830 -6100 P Please consider the environment before printing this message. This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. n.Rw_w For full disclaimer see http: / /www.omnni.com /legal /OMNNI_Email_Disclaimer.pdf 11/23/2009 Page l of l Noe, Brian From: Benner, Kevin Sent: Monday, November 23, 2009 7:06 AM To: Noe, Brian Subject: FW: Penetration between the Equipment Room and Communication Chase - Wittman Tower Attachments: UL_C AJ_3061.pdf Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Saturday, November 21, 2009 1:28 PM To: Benner, Kevin Subject: Penetration between the Equipment Room and Communication Chase - Wittman Tower Kevin — Attached is the UL fire penetration detail that FAA sent to me that is more realistic of what was actually done. If there is a deviation from this detail, I believe the only deviation is that not all cables may be separated by the 1/8" suggested. The mineral wool has been placed and fire caulk is more than ' /4 in thickness. Please review this detail and let me know your thoughts. If you do not agree that this is satisfactory for this wall and this application, please let me know what you would like to see done. Thanks Kevin! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com /legal /oMNNI_Email_Disclaimer.pdf 11/23/2009 2004 FIRE RESISTANCE DIRECTORY G •"( i as r L stn Ffg�a.^•A^ ;;,.,::: :. / "` 2000 THROUGH PENETRATION FIRESTOP SYSTEMS (XHEZ) THROUGH PENETRATION FIRE: f t ` ,. with steel nuts and min 1 -1/4 in diam steel fender washers. Three System No. C ` anchor ;� < ;r r? ,,,a s, .?,.::.: bolts, synunetricalty located, required for nom 1/2 in. to nom 3 F Rating — z k t in. diam pipes. Four anchor bolts, symmetrically located, required for T Rating — { t f rj y Y : rnom 3 -1/2 and 4 in. diam pipes As a final step, bend retainer tabs 90 } s i W . , 4 deg toward pipe to link wrap strip layers in position. tir, s' « t , } E 7. Firestop Device *_ (Not Shown) — An an alternate to Item 5 and 6 A K Yr for noun 1 -1/2, 2, 3 or 4 in. diam nonmetallic sleeves, a firestop device = ` consistin of a sheet - steel split collar lines with intumescent material g and pro vided with steel clips for attachment may lx used .1 irestop �,;�� � j �, r •,: , : device to be installed on underside of floor or on both sides of wall in � 4 t �•� t accordance with the accompanying installation instructions. . r °rr > 3 j ' ......... 3M COMPANY I'PD 150, PPD 200, PPD 300 Pl'D 400 ,, %�����; *33ear•ing the UL Classification Mark ,> " System No. C-AJ-3061 2 ¢ > :'`: F Ratings — 2 and 3 Hr (See Items 1. and 4) `;f�; T Ratings — 0 and 1/2 Hr (See Item 3) A ti ` *z I !' A © ' F . y ,, f . , © 1. Floor or Wall Assembly — Min 4 I/ © or normal weight (100 -150 pcf) concrc a ` `"�_ �, • '. of any UL Classified Concrete BI < ' . z °. See Concrete Blocks (CA7.T) category• < : C�. ;� I names of manufacturers g• t :7 j'':: „3 •. '> � n le 2. Cables — Max 7/C No. AG cl - or cross - linked (XLPi:) i " ate cross :Sectional area of cables ti r + 'N ' "' ppperrent of the aggregate cross - section gi ? h. • • be rigidly supported on both sides of 1 ;t 3. Packing Material — Min 2 in. thicki A ' batt insulation firmly packed into the SECTION A-A Packing material to be recessed from surfaces of wall as required to accom s v 1. Floor or Wall Assembly— Min 4 -1 /2 in. or min 7 -1/2 in. thick rein- fill material. forced lightweight or normal weight (100 -150 pcf) concrete. Will may .I. Fill, Void or Cavity Material* — Ser also be constructed of any Lit.. Classified Concrete Blocks . F Rating is material applied +vithin the annulus, 2 hr for floor or wall assemblies less than 7 -i/2 in. thick, and 3 hr both surfaces of wall. Yri when 7 -1/2 in. thick or greater. Max diam of opening is 6l/2 in. HILTI CONSTRUCTION CHI � *See Concrete Blocks (CA7 category in the Fire Resistance i)irectory foi HiLTI INC — FS -One Sealant s .� ,,.,,,.,, •.. ,: names of manufacturers. *IIear•ing the lJi.. Classification Mark t 2. Sleeves — (Optional) — 7 he following slcrwes may be used System No. A. Metallic Sleeve— Nam 6 in diam (or snmtler) sled Scheclule'10 P Ring - (or heavier) pipe cast or grouted into floor or wall assembly, flush T Rating - ` With Hoar or wall surfaces. L Rating At Ambient —1 fi. Nonmetallic Sleeve• - - Nom 6 in. diam (or smaller) Schedule 40 I. Rating At 400 F polyw.inyl chloride (PVC) pipe cast ar grouted into floor or wall ass(mb1) flush + +ith Hoar or + +=all surfaces. r ` •. Through Penetrants — Cables — Aggregate cross-sectional area of cables in opening to be max 45 percent of the cross sectional area of the t'1 � operning. Min separation betwe=en cables and het en cables and i �% .__ .._ periphery of opening is 1/8 in. Cables to be rigidly supported on both ,r�• sides of floor or wall assembly. The following types and sizes of copper i'<;�:., - .:: �... ,�•,;✓ '.,,._..,. :.- conductor cables may be used: 7. • , z fF r A. Max 1/C 500 kcmit cable with cross4inked polyethylene (X11-1) ;, J jacket. B. Max 8/C N WW o. 12 AG or max 17/C No. 14 AWG cable with T XLPI: insulation and jacket. C. Max 100 pair No. 24 AWG cable with PVC insulation and jacket. =: T Rating is 1/2 hr for cables A and B. 1. Floor or Wall Assembl y — Min 4 -1 T Rating is 0 hr for cable C. or normal weight (100 -150 pct) cone 4. Packing Material --- Min 4.5 pcf mineral wool Batt insulation firmly forced lightweight nr normal weigh acked into the opening +,= con p ' con y structed of an UL Classified c ` s'= • •= ; ": % least 50 eicent. Min a so that the width of the o ol is ressed at ckin material thickness for a 2 or 3 hr F Rat- in is it in. ing is 3 -314 or 5 -3/4 in., respectively. Packing material to be recessed Sec Concrete Blocks (CA7..T) catego from top surface of hoar or from both surfaces of wall as required to names of manufacturers. _rs% :•:.`.': accommodate the required thickness of till material. 2. Cables — Max 7 /C: No. 12 AWG c 5. Pill, Void or Cavity Material* — Caulk — Min 1/4 in thickness of or cross- linked of eth lene Xt PE { � caulk applied within the annulus, flush with top surface of floor or gate cross ;Sectional area of cables it with both surfaces of wall, max 20 percent of the aggregate Cr( t <`" ::: BURROUGHS & CHAPIN —T 1 } P y >e 1anersta 2006 (floors or Cables to be spaced a min 1 /2 in. < sides of floor or wall assembly. 3. Packing Material — Min 4 in. tlnic walls) or 1 nerstop 1(MISI. (floors only) ;' ; ... *Bearing the Ul, Classification Mark batt insulation insulation firmly packed into c i X ,,... ing material to be recessed from to 8-3 - r;`: faces of ill as required to accamr material. 4. Fill, Void or Cavity Material* — & fill material applied within the am ; =< ;: :. or with both surfaces of wall. � >a'= >:;. HILTI CONSTRUCTION C; HILTI INC —CP601S, CP604 LOOK FOR THE UL MARK ON PRODUCT Page 1 of 2 Noe, Brian From: Benner, Kevin Sent: Monday, November 23, 2009 7:07 AM To: Noe, Brian Subject: FW: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower Attachments: Fire stop system.pdf Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Saturday, November 21, 2009 2:16 PM To: Benner, Kevin Cc: terry.ripp @dot.wi.gov; Michael .Schmid @ Miron - Construction.com; tim.marty@wi.gov Subject: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower Kevin — I have reattached the detail that was forwarded to you in our last correspondence regarding this penetration. I have contacted Miron Construction on this detail and Miron Construction has contacted Schindler elevator on the detail. While this detail may not fit the attached detail exactly, it is the nearest Hilti detail that could be found for the application by the contractor. What was installed, per Mike Schmid at Miron, was the wireway was packed with steel wool as per the drawing, and then a sheet metal enclosure was installed to contain the steel wool. The fire caulk was applied over and around the sheet metal enclosure. I did touch bases with the state elevator inspector, Tim Marty, and he indicated that as part of his inspection, before issuing an elevator use permit, he does review not only all the elevator components and operation, but also the fire wall penetrations. Mr. Marty indicated that if he had noted any concems with this particular penetration, he would have noted the concem on his report. He did indicate he was satisfied with the installation of this penetration at the time of his inspection. He also indicated that the State Elevator Inspector would have jurisdiction over this installation, but suggested that if you had further concerns, that you could give him a call. We would just ask that you contact Mr. Marty to discuss to see if there can be some agreement on this penetration. While we are not looking to circumvent anyone's concerns regarding any portion of this project, we are mostly interested in getting the job complete and obtaining the official occupancy permit for this project. If you are not satisfied with either detail on the remaining fire penetrations in question or are not interested or will not discuss the elevator hoistway penetration with Mr. Marty or have discussed and would still have some action item, we would just ask that you provide some direction on what you would like to see done. Again, we are just looking to close the project out but we also want to close the project out in compliance with codes and requirements. Thanks Kevin! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 11/23/2009 Page 2 of 2 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com /legal /OMNNI_Email_Disclaimer.pdf 11/23/2009 System No. C —AJ -6017 F RATING = 3 -HR. T RATING =OHR. - A © • . _ • A SECTION A -A 1. Floor or Wall Assembly — Min 4 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max area of opening is 224 square in. with max dimension of 28 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Busway+ — Nom 26 in. wide (or smaller) by 6 in. deep (or smaller) "I" shaped steel enclosure containing factory mounted aluminum bars rated for 600 V, 4000 A. One busway to be installed within the opening. The annular space between the flange tip of the busway and the periphery of the opening shall be 1 in. The annular space between the web of the busway and the periphery of the opening shall be 2 in. Busway to be rigidly supported on both sides of floor and wall assembly. The busway shall bear the UL Listing Mark and shall be installed in accordance with all provisions of Article 364 of the National Electrical Code, NFPA No. 70 4. Firestop System — The firestop system shall consist of the following: A. Packing Material — Min 3 -1/2 in. thickness of min 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. B. FII, Void or Cavity Material* — Sealant — Min 1 in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI, Inc. — FS —ONE Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking L1z�l �10 0'F/0 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. FlRESEOP SYSTEMS c us July 17, 1998 �� PBS" MEMORANDUM TO: Tim Bolwerk, P.E. — OMNNI Associates, Inc. FROM: Mathew Leiner, AEA — PBS &J RE: Wittman Regional Airport ATCT Fire Rating Clarification DATE: October 27, 2009 Dear Mr. Bolwerk: Here is our clarification and explanation of the fireproofing requirements for the air traffic control tower. Our code analysis was based on IBC 2003 as indicated on plan sheet G0.02T. Sheet G0.02T also indicates the fire rating requirements as follow: Vertical Exit Enclosure: 2 hour rating minimum for four stories or more. (Per IBC Section 1019.1) Shaft Enclosure: 2 hour rating minimum for four stories or more. (Per IBC Section 707.4) Per IBC Table 601 (Type IB Construction type): Structural Frame = 2 hour rating Bearing Walls = 2 hour rating Floor Construction = 2 hour rating Roof Construction =1 hour rating Per IBC Section 412.1.3 as it relates to Towers; if the exit stairway and elevator hoistway are located in the same shaft enclosure, a 4 hour rating separation needs to be provided. Our explanation for indicating 4 hour walls UL designs on sheet A9.01 T is as follows: The Structural Engineer calculations dictated the thickness of the precast concrete walls to be used and based on those thicknesses the UL Design were established. We have used two different thicknesses of precast walls in this project; an 8 inch and 14 inch and both walls based on their thickness provides a fire rating of more than 4 hours. Refer to IBC Table 721.3.2. The reason 4 hour rating UL Design were indicated on sheet A9.01T was because there were no UL Design that will provide a 2 hour rating using a 8 or 14 inch thick wall. PBS&J Tampa Architecture Department Suite 200 * 5300 W Cypress St * Tampa, FL 33607 * Tel. 813.282.7275 * Fax 813.288.0730 The walls thickness and due to the nature of the material (concrete) exceeded the 2 hour minimum rating required for this project. The fire stopping / fire proofing for penetrations to be provided to comply with the fire ratings indicated on sheet G0.02T "Life safety Plans ". To summarize the fire rating requirement; we have indicated / provided 2 hour rating walls at all required locations, except for the 4 hour wall separating the stair and the elevator shaft. Feel free to call me if you have any additional questions. Sincerely, Mathew Leiner, AIA Architect of Record Wisconsin Lic. # 10218 -005 PBS&J Tampa Architecture Department Suite 200 * 5300 W. Cypress St * Tampa, FL 33607 * Tel. 813.282.7275 * Fax 813.288.0730 Page 1 of 3 Noe, Brian From: Benner, Kevin Sent: Tuesday, November 24, 2009 11:52 AM To: Noe, Brian Subject: FW: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower FYI Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Tuesday, November 24, 2009 8:09 AM To: Benner, Kevin Cc: terry.ripp @dot.wi.gov; Michael .Schmid @Miron - Construction.com; tim.marty@wi.gov Subject: RE: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower Kevin — Thanks for looking through your notes and getting back to us. 1 think meeting would be a good idea to try and get a plan of action to get this resolved. I will check with Mike Schmid of Miron to see if he would like to be at this meeting and some times he may be available and I will get back with you to try and get a time set up. Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Benner, Kevin [mailto :kbenner @ci.oshkosh.wi.us] Sent: Monday, November 23, 2009 11:53 AM To: Tim Bolwerk Cc: terry.ripp @dot.wi.gov; Michael .Schmid @Miron - Construction.com; tim.marty@wi.gov Subject: RE: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower Greetings Tim, Thanks for the response. You inspired me to review my inspection reports to see how this played out with the elevator inspection because I make a practice not to inspect anything associated with the elevator until the elevator inspection(s) has been approved. My Field Inspection Reports revealed that I was on site conducting an electrical inspection on 6/30/2008, and I documented on my report that the elevator inspection was being conducted at the time of my requested inspection; consequently I did not do any inspections associated with the elevator. I was back on site on 7/3/2008 for an electrical re- inspection and at that time I conducted an inspection for the electrical associated with the elevator, which I faxed to Jeff Delcore @ Schindler Elevator. In that inspection report I noted that the fire stopping was not installed in the hoistway between the machine room and the hoistway. 11/24/2009 Page 2 of 3 As for who has jurisdiction, it is any building official who has a code section associated with the installation. The elevator inspector, electrical inspector, building inspector, fire inspector, etc., may all have jurisdiction over the installation. At this time I think it would appropriate to meet you on site or for you to arrange access to the building, machine room and the hoistway for our building inspector Brian Noe & I to further verify the installation with the submittals you provided. Any questions or concerns please feel free to contact me. Thanks Tim, Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Saturday, November 21, 2009 2:16 PM TQ: Benner, Kevin . - Cc: terry.ripp @dot.wi.gov; Michael .Schmid @Miron - Construction.com; tim.marty @wi.gov Subject: Fire Wall Penetration between the Elevator Control Closet and Hoistway - Witman Tower Kevin — I have reattached the detail that was forwarded to you in our last correspondence regarding this penetration. I have contacted Miron Construction on this detail and Miron Construction has contacted Schindler elevator on the detail. While this detail may not fit the attached detail exactly, it is the nearest Hilti detail that could be found for the application by the contractor. What was installed, per Mike Schmid at Miron, was the wireway was packed with steel wool as per the drawing, and then a sheet metal enclosure was installed to contain the steel wool. The fire caulk was applied over and around the sheet metal enclosure. I did touch bases with the state elevator inspector, Tim Marty, and he indicated that as part of his inspection, before issuing an elevator use permit, he does review not only all the elevator components and operation, but also the fire wall penetrations. Mr. Marty indicated that if he had noted any concerns with this particular penetration, he would have noted the concern on his report. He did indicate he was satisfied with the installation of this penetration at the time of his inspection. He also indicated that the State Elevator Inspector would have jurisdiction over this installation, but suggested that if you had further concems, that you could give him a call. We would just ask that you contact Mr. Marty to discuss to see if there can be some agreement on this penetration. While we are not looking to circumvent anyone's concerns regarding any portion of this project, we are mostly interested in getting the job complete and obtaining the official occupancy permit for this project. If you are not satisfied with either detail on the remaining fire penetrations in question or are not interested or will not discuss the elevator hoistway penetration with Mr. Marty or have discussed and would still have some action item, we would just ask that you provide some direction on what you would like to see done. Again, we are just looking to close the project out but we also want to close the project out in compliance with codes and requirements. Thanks Kevin! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 P Please consider the environment before printing this message. 11/24/2009 Page 3 of 3 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http://www.omnni.com/legal/OMNNI_Email_Disclaimer.pdf 11/24/2009 800Z/ML 0069 - 0E8 (0Z6) xed 091.9 (0Z6) auoyd 171.6179 IM 'uo4alddy 84/C1 sweisAS cup 'oui 'sale!possy INNWO 3'd 51JaM108 w!1 {s�{ueyl }s!I s!44 uo apnlpu! lou p!p I '6u!pi!nq aseq ay} 4o wooi ;uawd!nbe ay; u! suo!4e4aued iieManj ay; 6u!leas 4o 8JeMe s! VVd sy *mow{ sn 401 aseaid lope 04 6u!44Aue aney nog( Jo 6u!y ;Aue pass!w 1 - u!naN 10)1111 .091.9 le 418sAw Jo 91709-9£Z -OZ6 42 '4!O ay} le Jauueg u!na>N 40e4uoo AIu!eliao ueo i(a44 `suo!;sanb Aue aney x(84; 41 i ;sn6ny !gun Aepud Jape swap asay; uo JJOM o; ape aq 4ou 1I!M Aay} aaeMe aye sqns ems as 'dVSv dn swap amp ys!u!4 way} aney pue sqns elgeo!{dde o; uo swap ay} pJeMJO4 aseald •dn pags!u!4 swat! asay; 406 o; 6uppoM enu!luoo o; paau op em `JoAeMoq 'puled Aouedn000 ue 6u!ne6 dn ploy mom anoge ay; 4o euou 4214; pa4eoipu! u!na>{ •s!y4 uo tiessaoau s! uo! ;0e iaypnl oN 884 puled s!y4 Jo; A4!0 ay; 04 966$ Jo; i{oayo 2 6u!pues seen ay pue `Aepsanl uo waypoN 40 oNuoaaS ills y4!M passnos!p i •bbd Jo4 paMa!naJ pey i(ayl voM 0141.104 way;JoN wa4 pau!e4go aq o; spaau aa4 4!waad 06241On Mot •L •coeds 6u!i{JoM 40 „gE J04 „ge lno pua}xe o; spaau 3i •J8u1g0 844 woi4 „OE }no papua }xe /quo SJe;u!M ;sn6ny Aq panelsu! wJo4}eid Jall!yo 0 41 •9 •palle4su! aq o} paau lI!M slyl •sJe4u!AA ;sn6ny Aq 48i( 4o se palie4su! uaeq 1ou sey a hued anoge plays uo!4oa148p 8111 g *Apo ay} u! NJOM 6u!op .104 Jalpu!y0S woi4 NioMiaded tiessaoau ay; 0A1038J P!P 4!a 8 41 'dVSV ley} 486 pue 804 J!egl u! puss pinoys i(841 'Jolenale 844 uo voM leoppel2 X04 }!wiied e aney ;oU saop J8Ipu!yOS j7 •6u!4ea aleudoidde ay; slaew }! os i({6u4p.io0oe pallelsu! pue peloaidemi eq pinoys uo!leJ }sued s!y; Moy uo pepinoJd eq pinoys map y •ap!s AeM 4s!oy .104ena10 8111 uo;noJ6 /Jepow pue ap!s 4asoip Jolenale ay; uo i{lne0 04440 s ;s!suoo AguaJJno 6u!40oJdaa!d •pajooidan4 i iiedoid aq o; Jeadde ;ou p!p Jo ;enal8 ay }.104 si 2M aa!M !wanes su!24uoo;e141 i(eM ;s!oy Jo4enale ay; pue las0lp palwoo Jolenale 844 ueaM}aq uo!48Jlauad Hem 8111 •£ '40 0.120 ue)I24 aq o; spaau 1! 'wa{goid a s! wain 4! Jo,pue passeippe seM s!44 4! Await pinoys am •u!nayl Jed Jaipuiyog i(q passaappe seM wal! s!y442(44 Jeedde ;ou p!p 41 •pane ;su! aq wogs s6nl az!s ;p0.uoo ay; pue aJ!M4o azIs ay; Joy e6aei 00) 0J8M 4uewd!nba Ioi;uoo Jolenale ay} uo sez!s 6ni ay; pe ;e0!pu! mu) Jo ie/tale 8yl 4o uo!;08dsu! 041 uo wa ;! ue seM 8Jayl •Z •80ueua4u!ew 6uunp ;d8Oxa sew!) 112 le pasoIO UI2w8J ploys .loop 844 ;ey16u!leolpu! poop ay; 4o ap!su! 8144 uo pJeoe1d 2 144!M Joop ay; uo ao!nap uado ploy a acs 01 am mom x(844 pue (44oyuuea ui(py:) Jopadsul ;6ulpl,n ay; pue 4uaw)aedaa aJ!d 141!M s!144 pessnos!p peg ay ;e44 u!naN way a6essew pew a0!on a p8n!ao8J i • unlu! Jo4.1e! ;ua4od ay; 14}!M s4uauodwoo 120!J40810 uo 6ui pom s! auoawos al!(M as0lp moo .loop ay; se waou00 2 s! s!yl •uado )IooI lou II!M 42(44 l! uo Jesol0 a s214 Joop ;uaun0 841 '{anal uo!4oun(aig uo ;asolp plum Joie/tap ay; X04 Joop ay; up • 6 :Moiaq pals!! 8.8 swap asa41 aim ua)124 aq 016u!u!ewaJ swa;! panes 0.12 aJay; `611!wow s!44 6u! ;caw .ino uo paseg •suo!40adsu! 120!J;oala sno!naJd uo peseq paloaJJio0 aq o; pau!ewaJ 4244 swa;! y6noJy4 06 04 'Jo ;oadsul Iep!J4081g yso)Iysp `Jeuuag u!na>N yl!M 6u!wow s!4} law 1 - env podem uo!4padsul p18!d uo! ;oadsul 123!.14088 ay; uo 6u!ulewalJ swap :;oafgng srr!M•e4e;s'4op©n dd!rtiJa} !no6•ee4 @JaJay3s•f• ;loos :wo0'uol4ona4suo0- uomol@p sweJp•i(4s!Na !'f uIlly `44oyuuea :uina>N `Jeuuag :33 woo•uo! 4pn4suo0- ualyJwp!wy3S•laey0!IJ :ol Wd EE:Z 800Z 'EZ Ain f 'AepseupaM :wog [woo•!uuwo @vaMp9•w!l] NaaMIo9 W!l :woj uAllv'J oquuea I JO I abed Page 1 of 2 Noe, Brian From: Benner, Kevin Sent: Thursday, February 18, 2010 8:17 AM To: Tim Bolwerk Cc: Noe, Brian Subject: RE: Wittman Tower - Occupancy Permit Hi Tim, I also remember the conversation, but I do not remember the details. This is a job specific permit not an annual permit. The only annual electrical permits we have are for manufacturing. Our municipal code also states that work conducted without permit shall pay a double permit fee or an additional $100.00 which ever is greater. Also they did not renew their electrical contractor's license for 2010, so they will also have to procure that license in order to issue a permit now. They did have a license at the time the work was conducted. Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Thursday, February 18, 2010 8:03 AM To: Benner, Kevin Cc: Noe, Brian Subject: RE: Wittman Tower - Occupancy Permit Kevin — So Schindler still needs to procure this permit? Is this the annual permit that the Contractors need to obtain to do electrical work within the City or is it a permit specific to the installation at the tower? I know this was discussed, but I don't recall the details right now. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Benner, Kevin [mailto :kbenner @ci.oshkosh.wi.us] Sent: Thursday, February 18, 2010 7:09 AM To: Tim Bolwerk Cc: Noe, Brian Subject: RE: Wittman Tower - Occupancy Permit Hi Tim, While Brian was processing the paperwork for the Occupancy Permit, it became apparent that Schindler has not procured their 2/18/2010 Page 2 of 2 electrical permit for the wiring of the elevator. The work card was started for this 7/28/08. Schindler is aware of this requirement they have procured a permit with us as late as 2009. I apologize for any inconvenience, Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Tuesday, February 16, 2010 11:58 AM To: Benner, Kevin Cc: PMoll @co.winnebago.wi.us; terry.ripp @dot.wi.gov Subject: Wittman Tower - Occupancy Permit Hi Kevin — I am just following up on the status of the occupancy permit for Wittman Tower. I had talked to Peter Moll last week, and at that point he had not received the permit, so I just wanted to be sure that there is nothing you are waiting on from me. If you could just give us an update on the status, that would be great. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 P Please consider the environment before printing this message. This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http: / /www.omnni.com /legal /OMNNI_Email_Disclaimer.pdf 2/18/2010 Page 1 of 1 Noe, Brian From: Benner, Kevin Sent: Thursday, February 18, 2010 7:09 AM To: Tim Bolwerk Cc: Noe, Brian Subject: RE: Wittman Tower - Occupancy Permit Hi Tim, While Brian was processing the paperwork for the Occupancy Permit, it became apparent that Schindler has not procured their electrical permit for the wiring of the elevator. The work card was started for this 7/28/08. Schindler is aware of this requirement they have procured a permit with us as late as 2009. I apologize for any inconvenience, Kevin Benner Electrical Inspector City of Oshkosh 215 Church Ave PO Box 1130 City of Oshkosh 54903 -1130 920 - 236 -5046 kbenner @ci.oshkosh.wi.us From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Tuesday, February 16, 2010 11:58 AM To: Benner, Kevin Cc: PMoll @co.winnebago.wi.us; terry.ripp @dot.wi.gov Subject: Wittman Tower - Occupancy Permit Hi Kevin — I am just following up on the status of the occupancy permit for Wittman Tower. I had talked to Peter Moll last week, and at that point he had not received the permit, so I just wanted to be sure that there is nothing you are waiting on from me. If you could just give us an update on the status, that would be great. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 This email is subject to OMNNI Associates, Inc. Electronic File Disclaimer. For full disclaimer see http://www.omnni.com/legal/OMNNI_Email_Disclaimer.pdf 2/18/2010 :26) /co Sze) ezo &ldo I I i • i K^„ / , /00 ick-Lsrli.-- IZA412 _ _ µ... _ __ _.._ I ` . _....___....._...... ,__._ _ _ .. _ . �.— /�..{.,.m.. l ©. L:tC._.. 1. 11 1 I ' i ' 1; i i1 1 ii ;I is iI 1 ii ji I � ! 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 01/09 0 US � Memarrum cnicrawockn Federal Aviation (11/°) Administration subject: INFORMATION: ,Applicability of Local oats: JUN f 9 Building Codes to Federal Projects; Public Law 100 -678 Rsyty 10 Fran Associate Administrator for Airway A ° Facilities, AAF -1 . To Regional Airway Facilities Division Managers Several regions have recently questioned the extent to which local building codes apply to the Federal agencies in light of Public Law 100 -678. It is our interpretation that the law makes a major distinction between building codes and zoning codes and requires Federal agencies to: a. Design its facilities in accordance with nationally recognized building codes. b. Design its facilities to be compatible with all reasonable local zoning codes. c. Consider any local or sponsor building code requirements and adopt those we feel appropriate and beneficial. The law precludes the local officials or sponsor from penalising the agency for not adopting local code requirements. In our opinion this is the way we have been doing business for the past 20 years. On February 8, we requested the chief Counsel, AGC -1, to provide legal guidance on the applicability of PL 100 -678 (Attachment 1). In their response dated May 3 (Attachment 21,_ the Y essentially _ _ . _ . confirmed our interpretation. Moat significantly, the state or local officials, or the airport sponsor cannot withhold a building or construction permit because of our decision not to accept some portion of the local codes since this would, in effect, represent a penalty to the Federal agency. Also, the law does not apply to any projects funded prior to fiscal year 1990. t 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 02/09 2 In any event, it is essential that you submit all projects to the local officials for review and comment during the site adapt and design review processes, consider their comments in soma documented way, and consult with the regional Counsel on specific applications in cases where mutually acceptable agreements cannot be reached. g5/111 L 51‘4- Arnold Aquilano . 2 Attachments • • 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 03/09 ACTION: Applicability of Local Building Fe 8 ! Codes to Federal Projects; Public Law (PL) 100 --078 Associate Administrator for Swinney: Airway Facilities, AAF -1 FTS 267 -8571 Office of The Chief Counsel, AGC -1 When PL 100 -678 was adopted in 1988, we did not consider that it would have any significant impact on the FAA's design and construction functions. We already design all of our standard facilities to the most widely accepted national • mit building codes; namely, The Uniform Building Code, and the National Electric Code and other appropriate sections of the amemilft national fire protection association codes. We also adapt facilities to the regional code most normally accepted iris their region, including the Basic/National Building Code in the northeast and the South Florida Building Code in the •� southeast. lino: snw* The regions routinely consult with local officials and airport sponsors when site adapting designs to determine if any state or local code requirements are more stringent than the national standards. When local codes differ from the Dog national codes the regions discuss requirements with the local officials and make those changes determined to be SWMI X reasonable and beneficial. In most cases, few changes to the standards were necessary. In a few cases, significant ••mm changes were made to avoid confrontation with the local officials- or -to- avoid- delays -in construction of critical Doi facilities. ao srMa our most frequent disagreements with local sponsors involve: (1) sponsors attempt to place our facilities in a remote or •- less desirable area normally increasing costs for utility services, longer access roads, increased control and signal an cable routes to other airport facilities, and often higher airport traffic control tower (ATCT) structures; nt0.UM* (2) requests to comply with local aesthetic and - zoning regulations involving special exterior design treatments, ion.wao. screening walls, and in some cases major redesigns; (3) requests to comply with local fire safety requirements e.n such as fire water pumps, sprinkler systems, or more sophisticated fire detection and alarm systems. • 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 04/09 2 We believe that PL 100 -678 requires that ve: 1. design our facilities in accordance with nationally recognized building codes; 2. design our facilities to be compatible with all reasonable local zoning codes; 3. consider any local or sponsor building code requirements and adopt those we feel appropriate and • beneficial. In ..our opinion, the law makes a major distinction between building and zoning codes. We further interpret the law as forbidding the local authority from penalizing the Federal Government for not adopting local building codes. Some sponsors believe that the law requires the Federal Government to adopt all local building codes and have threatened to withhold building permits for Federal construction unless we comply. We believe that the FAA has the right to, and as it sometimes has, proceed with construction without a local building permit. However, sponsors can and have held up construction by refusing to issue a building permit to our construction contractor. One particular case has recently been brought to our attention by the Central Region concerning their planned expansion of the St. Louis, Missouri, ATCT base building by approximately 2000 square feet. The St. Louis local officials are attempting to require the FAA to upgrade the entire 10,000 square foot building to current codes when the new addition is built. This could cost an additional, $100,000. In our opinion, this project is not even subject to PL 100 -678 since it was funded in fiscal year (FY) 1988. Please provide us with your interpretation of: 1. Our responsibility to consider local building codes. 2. Whether or not a local authority can penalize the Federal Government by withholding a contractors • ' permit. • 3. Under what conditions would the decision to not accept local codes require the Administrator's revie,? -4. Whether projects funded prior to FY 1990 but not yet constructed are subject to the law. 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 05/09 3 5. Provide a specific opinion on the St. Louis ATCT expansion project. - xf you determine that the law requires compliance with all local building codes, it would. increase the cost of site adapting national standard designs, and also increase the cost of construction significantly in soma cases. We estimate that the impact on the FY 3.990 construction projects alone could be several million dollars and result in several months of delays to some critical National Airspace System Plan projects already designed and currently being site adapted. Our design managers in the Program Engineering Service are available to provide additional information to your staff should it be desired. Please contact Donald Swinney, APS -120, on extension 78571 it. that is needed. Due to the potential major impact of your decision on our • current design and constuction•efforts, we request an expeditious review of these issues. ORIGINAL SIGNED 0! . !An M. KELLY Arnold Aquilano APS- 120:DSwinney:seb:1 /29 /9 0 :x 78570 cc:•APS- 120/100/1; AAF -1; All AU- 400's, Wordperfect:Codelttr 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 06/09 1 0 Memorandu d� Fedetof **Mon Sin: Legal Opinion: Applicability of Local Building Csr1: Codes to Federal Projects; F.L. 100 -678 3 mom f"s"K Staff Attorney, AOC -530 AMLIt T: Associate Administrator for Airway Facilities, AAP 1 This is in response to your request for a legal opinion on four Issues generally concerning the applicability of local building codex to federal projects in light of the Public Buildings Amendments of 1988, Public Law (P.L.) 100-678. You also request a specific opinion on the St. Louis ATOT expansion project. Each issue will be addressed in turn below following a brief recitation of the pertinent portions of P.L. 100 -678. Requirements of the Public Buildipgg_gmendments of 1918 Section 21(a) of the Public Buildings Amendments of 198$ specifically addresses building codes and requires that each building constructed or altered by GSA or any other Federal agency "shall be constructed or altered, to the maximum extent feasible as detemeined by the Administrator or head of such Federal agency, in compliance with one of the nationally recognized model building codes and with other applicable nationally recognised codes." 40 U.S.0 619(a). Section 21(b) addresses zoning laws and provides that buildings "shall be constructed or altered only after consideration of all requirements (other than procedural requirements) of - (1) local zoning laws, and (2) laws relating to landscaping, open space, minienm distance of a building from the property line, maximum height of a building, historic preservation, and esthetic qualities of a building, and other similar laws ... of a State or a political subdivision of a State which would apply to the building if it were not a building constructed or altered by a Federal agency." 40 O.S.C. 619(b). tr i 4 y r 11648 1. 4c o.►" — ! q. lida 4,ea,,dade Miss, aeb a sate &o+mom . 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 07/09 • Section 21(c) provides, "for the purpose of meeting the requirements of subsections (a) [compliance with nationally recognized model building codes] and (b) [consideration of and compliance with local zoning laws] " the agency is required to: (1) consult with State and local officials in preparing plans for a Federal project; (2) upon request, submit plans to such officials for review in a reasonable period of time (not to exceed 30 days); and (3) permit inspection by such officials during construction.. 40 U.S.C. 619(c). Section 21(d) authorizes State and local officials to slake recommendations "concerning measures accessary to meet the requirement of subsections (a) (compliance with nationally recognized model building codes] and (b) [consideration of and compliance with local zoning laws]." 40 U.S.C. 619(d). Moreover, local officials are permitted to make additional recommendations "concerning measures which should be taken in the construction or alteration of the building to take into account local conditions." 40 U.S.C. 619(d). The head of the agency "shall give due consideration to any such recommendations." 40 Q.S.C. 619(d). Section 21(e) provides that no action may be brought against the United States and "no fine of penalty may be imposed...for failure to meet the requirements of subsection (a), (b), or (c)...or for failure to carry out any recommendation under subsection (d) of this section." 40 U.S.C. 619(e). Further, neither the Government nor its contractors shall be "required to pay any amount for any action taken by a State or political subdivision of a State to carry out this section (including reviewing plans, carrying out on -site inspections, issuing building permits, and making recommendations)." Section 21(f); 40 O.S.C. 619(f). Section 21 of P.L. 100-678 applies only to construction and alteration _projects "for which funds are first appropriated for a fiscal year beginning after September 30, 1989." 40 D.S.C. 619(g). Under P.L. 100 -678 the FAA is affirmatively required to comply, to the maximum extent feasible, with one of the nationally recognised model building codes, and, to consider and comply to the maximum extent feasible, with local zoning laws and other related local 1aws.__Sections_______ 21(a) and (b). • We do not believe that the law generally requires consideration of local building codes, but believe such should be done as matter of policy. We note however, that under Section 21(d) the Agency is required to consider recommendations made by appropriate local authorities "concerning • 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 08/09 -a- . . measures which should be taken in the construction or alteration of the building to take into account local conditions." 40 U.S.C. 619(d). Thus, to the extent that an appropriate State official recommends compliance with a local building code which was generated by specific local conditions, the agency is required to consider the building code. • .f :- i • I• - • - ,• -, Coyeniment by yIthholding a ontra.•tnrg per t The answer is no. .Section 21(e) provides no penalty may be imposed against the Government for failure to meet the requirements of the Act or to carry out any recommendation. 40 U.S.C. 619(e). Moreover, Subsection (f) expressly provides the neither the Government nor its contractor shall be required to pay any amount for action taken by a State to carry out Section 21 including issuing building permits. 40 U.S.C. 619(f). Isane 3: Under wha conditions would thtjlec ajoRso not accept. local building cos require the Administrator's review/ Under Section 21(d), the head of the agency is required to consider any _-written recommendations made by appropriate State officials concerning "measures which should be taken in the construction or alteration of the building to take into account local conditions." 40 U.S.C. 619(d). This would include recommendations regarding compliance with local building codes engendered by "local conditions." We recommend that this authority be delegated from OST to the Administrator and downward for convenience. Tssue4kWhether projede funded prior to FY 1990 but not yet constrycted are e • ,ject to the law The answer is no. Section 21(g) provides that the law applies only to projects "for which funds are first appropriated for a fiscal year beginning after September 30, 1989." Iseue -5: The St. Louie ATCT Eirnnneirn Drnisnt As we understand the facts, Central Region is planning a 2000 square foot expansion of the St. Louis, Missouri, ATCT base building. St. Louis official; are attempting to require the FAA to upgrade the entire original ATCT, approximately 10,000 square feet, - current - codes - when - -- the.new addition is built. The expansion was funded in FY 1988. Our take on the issue, as we understand it, comports with yours; that is, P.L. 100 -678 does not apply since funds were first appropriated for the • 07/01/2008 10:40 8472947241 FAA ANI 480 PAGE 09/09 project before FY 1990. Bawever, since this is a matter within the province of the Central Region, we intend to follow up on the matter with Counsel in the Central Region to assure that we have a full understanding of all relevant facts and that our views are consistent. if you have any question, concerning this memorandum or need any additional assistance please feel free to contact me at extension 73480. • 44 g 3644-114La- LeAnne M. Faulkner • PAGE 1 LEVEL 1 - 1 OF 1 DOCUMENT UNITED STATES CODE SERVICE Copyright (c) 2003 Matthew Bender & Company, Inc., one of the LEXIS Publishing (TM) companies All rights reserved * ** CURRENT THROUGH P.L. 108 -59, APPROVED 7/14/03 * ** TITLE 40. PUBLIC BUILDINGS, PROPERTY, AND WORKS SUBTITLE II. PUBLIC BUILDINGS AND WORKS PART A. GENERAL CHAPTER 33. ACQUISITION, CONSTRUCTION, AND ALTERATION =1; GO TO CODE ARCHIVE DIRECTORY FOR THIS JURISDICTION 40 USCS @ 3312 (2003) 3312. Compliance with nationally recognized codes s) Application. (1) In general. This section applies to any project for construction or Iteration of a building for which amounts are first appropriated for a fiscal =ar beginning after September 30, 1989. (2) National security waiver. This section does not apply to a building for rich the Administrator of General Services or the head of the federal agency ithorized to construct or alter the building decides that the application of its section to the building would adversely affect national security. A acision under this subsection is not subject to administrative or judicial sview. 3) Building codes. Each building constructed or altered by the General srvices Administration or any other federal agency shall be constructed or ttered, to the maximum extent feasible as determined by the Administrator or le head of the federal agency, in compliance with one of the nationally :cognized model building codes and with other applicable nationally recognized )des, including electrical codes, fire and life safety codes, and plumbing )des, as the Administrator decides is appropriate. In carrying out this )bsection, the Administrator or the head of the federal agency shall use the atest edition of the nationally recognized codes. Zoning laws. Each building constructed or altered by the Administration or ty other federal agency shall be constructed or altered only after )nsideration of all requirements (except procedural requirements) of the )flowing laws of a State or a political subdivision of a State, which would )ply to the building if it were not a building constructed or altered by a aderal agency: (1) Zoning laws, (2) Laws relating to landscaping, open space, minimum distance of a building :om the property line, maximum height of a building, historic preservation, ;thetic qualities of a building, and other similar. laws. 9) Cooperation with State and local officials. (1) State and local government consultation, review, and inspections. To meet to requirements of subsections (b) and (c), the Administrator or the head of ie federal agency authorized to construct or alter the building -- PAGE 2 40 USCS @ 3312 (A) in preparing plans for the building, shall consult with appropriate )fficials of the State or political subdivision of a State, or both, in which :he building will be located; (B) on request shall submit the plans in a timely manner to the officials or review by the officials for a reasonable period of time not exceeding 30 Lays; and (C) shall permit inspection by the officials during construction or .iteration of the building, in accordance with the customary schedule of nspections for construction or alteration of buildings in the locality, if the fficials provide to the Administrator or the head of the federal agency- - (i) a copy of the schedule before construction of the building is , egun; and (ii) reasonable notice of their intention to conduct any inspection efore conducting the inspection. (2) Limitation on responsibilities. This section does not impose an bligation on any State or political subdivision to take any action under aragraph (1). e) State and local government recommendations. Appropriate officials of a tate or political subdivision of a State may make recommendations to the dministrator or the head of the federal agency authorized to construct or alter building concerning measures necessary to meet the requirements of subsections b) and (c). The officials also may make recommendations to the Administrator or he head of the federal agency concerning measures which should be taken in the onstruction or alteration of the building to take into account local onditions. The Administrator or the head of the agency shall give due onsideration to the recommendations. f) Effect of noncompliance. An action may not be brought against the Federal overnment and a fine or penalty may not be imposed against the Government for ailure to meet the requirements of subsection (b), (c), or (d) or for failure o carry out any recommendation under subsection (e). g) Limitation on liability. The Government and its contractors shall not be equired to pay any amount for any action a State or a political subdivision of State takes to carry out this section, including reviewing plans, carrying out n -site inspections, issuing building permits, and making recommendations. ISTORY: (Aug. 21, 2002, P.L. 107 -217, @ 1, 116 Stat. 1165.) HISTORY; ANCILLARY LAWS AND DIRECTIVES rior law and revision: evised Section Source (U.S. Code) Source (Statutes 'at Large) 312(a)(1) 40 :619(g). Pub. L. 86 -249, Sec. 21, as added Pub. L. 100 -678, Sec. 6(a), Nov. 17, 1988, 102 Stat. 4051. 312(a)(2) 40:619(h), 312(b) 40:619(a). 312(c) 40:619(b). 312(d) 40:619(c). PAGE 3 40 USCS @ 3312 312(e) 40:619(d). 312(f) 40:619(e)• 312(g) 40:619(f). INTERPRETIVE NOTES AND DECISIONS Imposition of liability on U.S. on basis of height of guardrail was precluded y former 40 USCS @ 619(e), where pedestrian ramp guardrail over which edestrian was thrown was some 4 inches shorter than height required by state uilding code, but statute provided that government could not be held liable, in pite of failure to conform with state building codes. Schuyler v United States 1997, SD Cal) 987 E Supp 835. TITLE 40 , CHAPTER 12 , Sec. 619. Page 1 of 3 LIT legal information institute US CODE COLLECTION 1114, LIIN collection home CI= U NITED STATES Cove TITLE 40 > CHAPTER 12 > Sec. 619. Prey Search this title: Sec. 619. - Compliance with nationally recognized codes s Title Ito (a) Building codes Each building constructed or altered by the General Notes Services Administration or any other Federal agency shall be Updates constructed or altered, to the maximum extent feasible as Parallel authorities determined by the Administrator or the head of such Federal (CFR) agency, in compliance with one of the nationally recognized Topical references model building codes and with other applicable nationally recognized codes. Such other codes shall include, but not be limited to, electrical codes, fire and life safety codes, and plumbing codes, as determined appropriate by the Administrator. In carrying out this subsection, the Administrator or the head of the Federal agency authorized to construct or alter the building shall use the latest edition of the nationally recognized codes referred to in this subsection. (b) Zoning laws Each building constructed or altered by the General Services Administration or any other Federal agency shall be constructed or altered only after consideration of all requirements (other than procedural requirements) of - (1) zoning laws, and (2) laws relating to landscaping, open space, minimum distance of a building from the property line, maximum height of a building, historic preservation, and esthetic qualities of a building, arid other similar laws, of a State or a political subdivision of a State which would apply to the building if it were not a building constructed or altered by a Federal agency. TITLE 40 , CHAPTER 12 , Sec. 619. Page 2 of 3 (c) Special rules (1) State and local government consultation, review, and inspections For purposes of meeting the requirements of subsections (a) and (b) of this section with respect to a building, the Administrator or the head of the Federal agency authorized to construct or alter the building shall - (A) in preparing plans for the building, consult with appropriate officials of the State or political subdivision, or both, in which the building will be located; (B) upon request, submit such plans in a timely manner to such officials for review by such officials for a reasonable period of time not exceeding 30 days; and (C) permit inspection by such officials during construction or alteration of the building, in accordance with the customary schedule of inspections for construction or alteration of buildings in the locality, if such officials provide to the Administrator or the head of the Federal agency, as the case may be - (i) a copy of such schedule before construction of the building is begun; and (ii) reasonable notice of their intention to conduct any inspection before conducting such inspection. (2) Limitation on State responsibilities Nothing in this section shall impose an obligation on any State or political subdivision to take any action under paragraph (1). (d) State and local government recommendations Appropriate officials of a State or a political subdivision of a State may make recommendations to the Administrator or the head of the Federal agency authorized to construct or alter a building concerning measures necessary to meet the requirements of subsections (a) and (b) of this section. Such TITLE 40 , CHAPTER 12 , Sec. 619. Page 3 of 3 officials may also make recommendations to the Administrator or the head of the Federal agency concerning measures which should be taken in the construction or alteration of the building to take into account local conditions. The Administrator or the head of the Federal agency shall give due consideration to any such recommendations. (e) Effect of noncompliance No action may be brought against the United States and no fine or penalty may be imposed against the United States for failure to meet the requirements of subsection (a), (b), or (c) of this section or for failure to carry out any recommendation under subsection (d) of this section. (f) Limitation on liability The United States and its contractors shall not be required to pay any amount for any action taken by a State or a political subdivision of a State to carry out this section (including reviewing plans, carrying out on-site inspections, issuing building permits, and making recommendations). (g) Applicability to certain buildings This section applies to any project for construction or alteration of a building for which funds are first appropriated for a fiscal year beginning after September 30, 1989. (h) National security waiver This section shall not apply with respect to any building if the Administrator or the head of the Federal agency authorized to construct or alter the building determines that the application of this section to the building would adversely affect national security. A determination under this subsection shall not be subject to administrative or judicial review Prev t copy ri , h US •-■ I e, r. 0" • o", Page 1 of 3 Dannhoff, AIIyn J. From: Dannhoff, AIIyn J. Sent: Friday, July 25, 2008 7:36 AM To: 'Tim Bolwerk' Cc: Benner, Kevin Subject: RE: Control Tower - Outstanding Item Responses required for Occupancy Permit Good Morning Tim; Your summary is accurate. Very few projects come to a "perfect" close. We understand there are generally items to be cleaned up at the end of the project and as long as we.have developed an opinion the project is reasonably save, we typically proceed with allowing Occupancy as long as we have a reasonable schedule for completion. Additionally, if something were to present itself that would cause us to reconsider, we would first bring it to your attention in hopes of getting such issues addressed before taking action on Occupancy since we had entered into an agreement for Occupancy. Please advise the affected contractors to follow up with the necessary reinspections to verify compliance. We will look forward to approving everything (save the FAA work) by the end of August. Have a good week end. Allyn Dannhoff Director of Inspection Services From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Thursday, July 24, 2008 3:15 PM To: Dannhoff, AIIyn J. Cc: terry.ripp @dot.state.wi.us; scott.j.scherer @faa.gov; Michael .Schmid @Miron - Construction.com; PMoll @co.winnebago.wi.us Subject: FW: Control Tower - Outstanding Item Responses required for Occupancy Permit Allyn - Per our conversation this afternoon, it is my understanding that it will be acceptable to operate out of the new control tower without legal consequences, but that you would prefer to hold off on issuance of final occupancy until all work is completed by both Miron Construction and FAA. As I had indicated on the phone, the work by FAA will likely not be completed until November or December of this year in order for them to move all remaining equipment from the existing tower to the new tower. As far as the work Miron has remaining on the building portion of their contract, I would estimate that everything would be totally complete by the end of August. Miron's work on the building will generally be punch list work, airfield lighting control fiber installation (which is mainly airfield work)and finishing up any items on the City inspection reports. Please verify that my understanding is correct and if you have any additional comments, please let me know. Thanks Allyn! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Tim Bolwerk Sent: Wednesday, July 23, 2008 4:01 PM To: Dannhoff, AIIyn J. Cc: Benner, Kevin; Wolf, Paul T.; Michael Schmid (Michael .Schmid @Miron- Construction.com); terry.ripp @dot.state.wi.us; Scott Scherer (scott.j.scherer @faa.gov) Subject: RE: Control Tower - Outstanding Item Responses required for Occupancy Permit Allyn - Responses to the items you have listed in your July 8 e - mail regarding the Occupancy Permit are given below. 7/25/2008 Page 2 of 3 1. Fire extinguishers have been installed as required. 2. A scanned copy of the Building and HVAC Compliance Statement is attached to this e-mail. 3. A scanned copy of the Precast Plan Approval Letter from the State is attached. 4. The fire shutter door did not release at the time of testing the smoke alarms in the lobby as the fire shutter door was deactivated at the time of the smoke alarm test so the door would not close on anyone. The door was tested by A & A Security and this test result will be included in their test documentation. Also, the fire shutter has been reactivated. Please see the attached e-mail string between Bill Seronko from Northern Electric and myself regarding the fire shutter door. 5. Kevin Benner has been in contact with Northern Electric regarding the work done by FAA. The work has been reviewed by Northem Electric and Kevin Benner did discuss with Northern Electric in addition to doing a follow up inspection on the work today, July 23. No additional items were noted by Kevin. The low voltage permit fee was to be mailed by Northern either late yesterday or today. 6. Schindler has sent in the required paperwork for doing electrical work in the City and will be sending in the permit and fees. FAA has contracted with Northern Electric to review FAA work and submit fees. 7. The work platform for the chiller was performed by August Winters, however, the platform was less than 36" deep. An e-mail has been sent to Miron Construction indicating that the platform depth will need to be corrected. 8. Plumbing approvals have been obtained. Electrical approvals have several items remaining to be completed after meeting with Kevin Benner this morning, July 23. An e-mail was sent to Miron Construction today itemizing the items that remain to be completed. We will continue to diligently work to complete the items on the list. These items will also be included on a punch list for the building until they are completed or resolved. Kevin Benner indicated that he thought that none of the items on the list that remain would hold up getting an occupancy permit, however, we do need to get the items finished up a quickly as possible. If there is any additional information you need or clarification on anything, please let me know. Miron Construction and OMNNI will continue to take care of any items remaining both on the electrical list and the punch list that was developed for the building by OMNNI. As previously noted, any items remaining on the electrical list will be put on the building punch list to be completed. If the above explanations are satisfactory, please forward the Occupancy Permit to me and I will forward to Miron, Winnebago County and FAA. Thanks Allyn! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Dannhoff, Allyn J. [mailto:adannhoff @ci.oshkosh.wi.us] Sent: Tuesday, July 08, 2008 8:22 AM To: Tim Bolwerk; scottjscherer @faa.gov Cc: Benner, Kevin; Wolf, Paul T. Subject: Control Tower Tim and Scott, I apologize for not being able to get this out till now. The following is a summary of what remains to be accomplished to secure the Occupancy Permit. 1. Install all Fire Extinguishers 2. Submit Building and HVAC Compliance Statements 3. Provide a copy of the Precast Plan Approval Letter from the state. 4. Explain why Fire Shutter door did not release when the smoke alarms in the Elevator lobby area were tested. 5. Provide correspondence from Northern Electric taking responsibility (vouch) for electric performed by others (FAA.) Correct all items on the Electric Correction Notice dated 6/30 (to our understanding this is in progress.) 6. Others performing electric work must secure their own permits. (Shindler Elevator) Please note a Correction Notice (dated 7/3 has been faxed to Shindler on 7/7) 7. complete the work platform for the chiller. 7/25/2008 Page 3 of 3 8. Secure Electric and Plumbing Approvals. These are what we have noted as being the outstanding items to complete to secure Occupancy Approval. CaII if you have questions. Allyn Dannhoff 920 - 236 -5045 7/25/2008 Safety and Buildings 2331 SAN LUIS PL STE 150 commerce.wi.gov GREEN BAY WI 54304 TDD # (608) 264 -8777 tsconsin www.commerce.wi.gov /sb/ www.wisconsin.gov epartment of Commerce Jim Doyle, Governor Mary P. Burke, Secretary November 22, 2006 CUST ID No. 261636 A7TN: Buildings & Structures Inspector TIMOTHY MAERTZ BUILDING INSPECTION OMNNI ASSOCIATES CITY OF OSHKOSH ONE SYSTEMS DR POB 1130 APPLETON WI 54914 OSHKOSH WI 54902 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 11/22/2008 Identification Numbers Transaction ID No. 1337446 SITE: Site ID No. 146753 Wittman Regional Airport Please refer to both identification numbers, 525 W 20TH Ave above, in all correspondence with the agency. City of Oshkosh, 54902 Fire Dept ID: 7003 FOR: Tenant Name or Addn/Alt Description: Airport Air Traffic Control Tower Object Type: Building ICC Regulated Object ID No.: 1104758 Major Occupancy: Business; Type IB Fire Resistive class of construction; New plan; 10,248 project sq ft; Completely Sprinklered; Occupancy: B Business; Sprinkler Design: NFPA -13 Sprinkler; Component(s) submitted with this transaction: HVAC ICC; Allowable area determined by: Fire Walls Tenant Name or Addn/Alt Description: Airport Air Traffic Control Tower Object Type: HVAC ICC System Regulated Object ID No.: 1104759 10,248 sq ft Area Heated The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Submit • This review does not include approval for the installation of Boilers & Pressure Vessels indicated on this plan. The installation of any Boiler or Pressure Vessel shall be registered with the Department by the installer before the system is placed in operation as prescribed by COMM 41.41. Registration shall be in writing on Form SBD- 6314. The required department forms may be obtained from the Division of Safety &Buildings, Material Orders, P.O. Box 2509, Madison, WI 53701 -2509, telephone 608/266 -3151, 608/264 -8777 (TTY), or at the Safety & Buildings web site at http: / /www. commerce. state. wi .us /SB /SB- DivForms.html #Boilers • Contact the Refrigeration/Boiler Safety Inspector listed at the end of this letter with any questions. • Comm 61.30(3) Submit, prior to installation, one (1) set of properly signed and sealed precast plans, a completed SB -118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety & Buildings, P.O. Box 7162, Madison, WI 53707 -7162. Note as per Comm 2.31(1)(d)6. the fee for a structural component erected prior to plan submTIF 440200 _ i Nu C. 5+ f TIMOTHY MAERTZ Page 2 11/22/2006 Reminders • This review does not include approval for elevator /escalator/ lift indicated on your plans. Contact Brian Rausch at (262) 521 -5444 for submittal requirements or click on forms at our web home page http: / /www.commerce. state .wi.us /SB /SB- HomePage.html. Designers are reminded that an elevator car capable of accommodating an ambulance stretcher for buildings 4 stories in height or more, as well as for all outpatient clinics, nursing homes and hospitals, is required by IBC 3002.4. Also, a drain or sump is required for any elevator pit. • Comm 61.31(2)(b) A copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. Changes to the approved plan must be submitted for review and approval. • • Comm 61.36(1)(a) & (b) This approval will expire 2 years after the date of this letter if the building shell is not closed in within those 2 years. Also, this approval will expire 3 years after the date of this letter if the work covered by this approval is not completed and the building ready for occupancy within those 3 years. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plansets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction /installation/operation. If this construction project will disturb one or more acres of land, an Erosion Control Notice of Intent (NOI) shall be filed with the department 14 days prior to any earth disturbing activities. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, • Fee Required $ 1,110.00 • Fee Received $ 1,110.00 Balance Due $ 0.00 John D VanBuecken, P.E. Building Plan Reviewer , Integrated Services WiSMART''code: 7648 (920)492 -7727 , Monday - Friday 8:00 am - 4:30 pm john.vanbuecken @wisconsin.gov cc: Peter R Ochs, State Building Inspector, (920) 948 -3500 , Friday, 7:45 A.M. - 4:30 P.M. Ruth Ellioit, Wittman Regional Airport Jon Anthony , ASCG Incorporated Tim J Marty, Elevator Inspector, (920) 428 -9422 Jon P Wolf, Boiler Inspector, (920) 723 -0032 Safety and Buildings PO BOX 7162 commerce.WL.gov MADISON WI 53707 -7162 tisconsin TDD #: (608) 264 -8777 �•commerce.wi.gov /sb/ www.wisconsin.gov Departrnent of Commerce Jim Doyle, Govemor Jack L. Fischer, A.I.A., Secretary December 05, 2007 CUST ID No. 261636 Fee Required $ 100.00 TIMOTHY MAERTZ Make Checks Payable To OMNNI ASSOCIATES Commerce. ONE SYSTEMS DR APPLETON WI 54914 REQUEST FOR ADDITIONAL INFORMATION SITE: Wittman Regional Airport ftna �ktt''r s a , ®o3 525 W 20TH Ave - Knapp Transaction ID No. 1489486 City of Oshkosh, 54902 Site ID No. 146753 ; Fire Dept ID: 7003 Fl y per:•,. r''� ®r a P :a : v FOR: Facility: 505465 WITTMAN REGIONAL AIRPORT 525 W 20TH ST OSHKOSH 54902 Object Type: Precast Plank Regulated Object ID No.: 1164430 Object Type: Precast Wall Regulated Object ID No.: 1164431 The submittal described above has been placed on HOLD and the review and approval is pending subject to receipt of the ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt of the additional information and/or revised plans, the plans will be reviewed for compliance to applicable Wisconsin Administrative Codes and Wisconsin Statutes. The following must be corrected/revised and accompany the resubmittal: • This submittal must include the original signature of the building designer on the component submittal line of the application form. Re- submit the application form with the building designer's ori ginal signature. • A required fee of $100.00 is due at the time of your component plan and application submittal. Until we receive the required fees, we are unable to process your submittal at this time Send your resubmittal into the address listed above, unless otherwise noted, and the department will review the resubmittal within 5 working days of receipt date. Please include a copy of this letter with your resubmittal. If you have any questions, after reading the above comments and related code sections cited, please call me at the telephone number below. If the above requested information and/or plans are not received within 30 business days of the date of this correspondence, this submittal will be returned denied. No fees will be refunded, and a new fee, application form, and submittal of plans /specifications will be required should you desire to continue with this project. The code in effect at the time of new submittal would apply. TIMOTHY MAERTZ Page 2 12/5/2007 Sincerely, Joanne Koch License/Permit Program Associate , Integrated Services (608)264 -7623 , 07:45 - 4:30 joanne.koch @wisconsin.gov cc: John R Anderson, State Building Inspector, (715) 823 -2014, Monday, 7:45A.M.- 4:30P.M. Ruth Ellioit, Wittman Regional Airport Building Inspection City of Oshkosh, 920/236 -5045 Safety and Buildings PO BOX 7162 commerce.wi.gov MADISON WI 53707 -7162 TDD #: (608) 264 -8777 tisconsin www.commerce.wi.gov /sb/ www.wisconsin.gov Department of Commerce Jim Doyle, Governor Jack L. Fischer, A.I.A., Secretary July 17, 2008 CUST ID No. 1081480 ATTN. Buildings & Structures Inspector BUILDING INSPECTION CLARK MEYER CITY OF OSHKOSH ONE SYSTEMS DR POB 1130 APPLETON WI 54914 OSHKOSH WI 54902 COMPONENT RECEIVED Identification Numbers Transaction ID No. 1489486 SITE: Site ID No. 146753 Wittman Regional Airport Please refer to both identification 525 W 20TH Ave - Knapp numbers, move, in all City of Oshkosh, 54902 correspondence with the agency ; Fire Dept ID: 7003 FOR: Facility: 505465 WITTMAN REGIONAL AIRPORT 525 W 20TH ST OSHKOSH 54902 Object Type: Precast Plank Regulated Object ID No.: 1164430 Code Applies Date: 12/05/07 Object Type: Precast Wall Regulated Object ID No.: 1164431 Code Applies Date: 12/05/07 The department has received the above component plan indicated as being reviewed for compliance with the general design concept and submitted by the building designer named above. The Department has filed the plans and other related documents. The department will rely on, and hold responsible, the building design professional and/or supervising professional of record for compliance with the rules. The responsible professional should particularly insure that proper loads and fire resistive rating have been incorporated to correspond to the building design. Particularly insure: proper dead and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper bearing/supports, concentrated loads etc, are properly conveyed to foundations; and that required fire ratings have been employed. The submitted materials have not been reviewed by the Department for compliance with all applicable administrative rules. The department reserves the right to formally review the plans in the future if the department determines that such a review is warranted, and to order corrective actions with respect to the outcome of that review. A copy of the plan that is identical to the plan submitted for our file shall be available for inspection at the job site. When the total building volume exceeds 50,000 cubic feet, the plan CLARK MEYER Page 2 7/17/2008 shall bear an indication of review that has been signed or initialed by the building designer of record. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. Sincerely, Fee Required $ 300.00 Fee Received $ 300.00 Balance Due $ 0.00 Diane C Morris Program Assistant 4 , Integrated Services , . x ® , 8:00 a.m. To 4:30 p.m. diane.morris @wisconsin.gov cc: John R Anderson, State Building Inspector, (715) 823 -2014 , Monday,7:45A.M.- 4:30P.M. Ruth Ellioit, Wittman Regional Airport Omnni Assoc Post - it® Fax Note 7671 Date, .2/07 pa°ges To P- i From `/ r 4. DUCT SYSTEMS Co./Dept. i1 AI r � Co. Phone # "/ Phone # ? _ c Z / j Fax # ?zo 'zir 7 r - s � /7 Fax # (� 4-08.4 maximum air temperature within nonmetallic ducts shall not exceed 250 °F (121 °C). nreutocxrng as requtreu to we iniernuitunua nuacuing 603.4.1 Gypsum ducts. The use of gypsum boards to form Code. air shafts (ducts) shall be limited to retum air systems where 602.4 Flood hazard. For structures located in a flood - hazard the air temperatures do not exceed 125°F (52 °C) and the zone or a high - hazard zone, plenum spaces shall be located gypsum board surface temperature is maintained above the above the base flood elevation or shall be protected so as to pre - airstream dew -point temperature. Air ducts formed by gyp - vent water from entering or accumulating within the plenum sum boards shall not be incorporated in air- handling sys- space during floods up to the base flood elevation. If the ple- terns utilizing evaporative coolers. num spaces are located below the base flood elevation, they Comm 64.0603 Note: For DHFS licensed ealthcare facilities as specified shall be capable of resisting hydrostatic and hydrodynamic in chs. HFS 124, 131, 132, and 134, also r fer to the following standards: loads and stresses, including the effects of buoyancy, during the Sheet Metal and Air Conditioning Contractors National Association, Inc. occurrence of flooding to the base flood elevation. (SMACNA), HVAC Duct Construction 'tandards –Metal and Flexible, 1995 edition. 603.5 Flexible air ducts and flexible air connectors. Flexible SECTION 603 air ducts, both metallic and nonme llic, shall comply with DUCT CONSTRUCTION AND INSTALLATION Sections 603.5.1, 603.5.1.1, 603.5.3. d 603.5.4. Flexible air 603.1 General. An air distribution system shall be designed connectors, both metallic and nonmetallic, shall comply with and installed to supply the required distribution of air. The in Sections 603.5.2 through 603.5.4. stallation of an air distribution system shall not affect the fire 603.5.1 Flexible air ducts. Flexib e air ducts, both metallic protection requirements specified in the International Building and nonmetallic, shall be tested in : ccordance with UL 181. Code. Ducts shall be constructed, braced, reinforced and in- Such ducts shall be listed and lab :led as Class 0 or Class 1 stalled to provide structural strength and durability. flexible air ducts and shall be ins . led in accordance with 603.2 Duct classification. Ducts shall be classified based on Section 304.1. the maximum operating pressure of the duct at pressures of 603.5.1.1 Duct length. Flexib e air ducts shall not be positive or negative 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, or 10.0 inches of limited in length. water column. The pressure classification of ducts shall equal 603.5.2 Flexible air connectors. Flexible air connectors, or exceed the design pressure of the air distribution in which the both metallic and nonmetallic, sha 1 be tested in accordance ducts are utilized. with UL 181. Such connectors sha 1 be listed and labeled as 603.3 Metallic ducts. All metallic ducts shall be constructed as Class 0 or Class 1 flexible air co i ectors and shall be in- specified in the SMACNA HVAC Duct Construction Stan- stalled in accordance with Section 304.1. dards—Metal and Flexible. 603.5.2.1 Connector length. Flexible air connectors Exception: Ducts installed within single dwelling units shall be limited in length to 14 eet (4267 mm). shall have a minimum thickness as specified in Table 603.3. 603.5.3 Air temperature. The de •ign temperature of air to TABLE 603.3 be conveyed in flexible air ducts . d flexible air connectors DUCT CONSTRUCTION MINIMUM SHEET METAL shall be less than 250 °F (121 °C). THICKNESSES FOR SINGLE DWELLING UNITS GALVANIZED STEEL 603.5.4 Flexible air duct and . ' connector clearance. Flexible air ducts and air connecto . shall be installed with a Minimum Equivalent APPROXIMATE minimum clearance to an applianc as specified in the a h thickness galvanized ALUMINUM PP P PP DUCT SIZE (inches) Gage No. B &S GAGE ante manufacturer's installation i structions. Round ducts and enclosed 603.6 Rigid duct penetrations. Duc system penetrations of rectangular ducts walls, floors, ceilings and roofs and air transfer openings in 14" or less 0.013 30 26 such building components shall be : rotected as required by Over 14" 0.016 28 24 Section 607. Exposed rectangular ducts 603.7 Underground ducts. Ducts sh.11 be approved for under - 14" or less 0.016 28 24 ground installation. Metallic ducts not having an approved pro - Over 14" 0.019 26 22 tective coating shall be completely en ased in a minimum of 2 For SI: 1 inch = 25.4 mm. inches (51 mm) of concrete. Comm 64.0603 Note: For DHFS licensed healthcare facilities as specified in chs. HFS 124, 131, 132, and 134, also refer to the following standards: 603.7.1 Slope. Ducts shall slope to • llow drainage to a point Sheet Metal and Air Conditioning Contractors National Association, Inc. provided with access. (SMACNA), HVAC Duct Construction Standards –Metal and Flexible, 1995 edition. 603.7.2 Sealing. Ducts shall be se. led and secured prior to 603.4 Nonmetallic ducts. Nonmetallic ducts shall be con- pouring the concrete encasement. strutted with Class 0 or Class 1 duct material in accordance 603.7.3 Flood hazard. All under! ound ducts located in a with UL 181. Fibrous duct construction shall conform to the flood - hazard zone or a high - haz, d zone shall be located SMACNA Fibrous Glass Duct Construction Standards or above the base flood elevation or slIall be protected so as to NAIMA Fibrous Glass Duct Construction Standards. The prevent water from entering or a cumulating within the M -50 2002 WISCONSIN ENROLLED COMM RCIAL BUILDING CODE CHAPTER 6 DUCT SYSTEMS SECTION 601 3. This section shall not apply to materials exposed GENERAL within plenums in one- and two - family dwellings. 4. This section shall not apply to smoke detectors. 601.1 Scope. Duct systems used for the movement of air in air - conditioning, heating, ventilating and exhaust systems shall 602.2.1.1 Wiring. Combustible electrical or electronic conform to the provisions of this chapter except as otherwise wiring methods and materials, optical fiber cable, and specified in Chapters 5 and 7. optical fiber raceway exposed within a plenum shall have Exception: Ducts discharging combustible material di- a peak optical density not greater than 0.50, an average rectly into any combustion chamber shall conform to the re- optical density not greater than 0.15, and a flame spread quirements of NFPA 82. not greater than 5 feet (1524 mm) when tested in accor- dance with UL 910. Only type OFNP (plenum -rated [B] 601.2 Air movement in egress elements. Exit and exit ac- nonconductive optical fiber cable) shall be installed in cess corridors shall not serve as supply, return, exhaust, relief or plenum -rated optical fiber raceways. Wiring, cable, and ventilation air ducts or plenums except as permitted by the In- raceways addressed in this section shall be listed and la- ternational Building Code. beled as plenum rated and shall be installed in accor- 601.3 Contamination prevention. Exhaust ducts under posi- dance with ICC Electrical Code. tive pressure, chimneys, and vents shall not extend into or pass through ducts or plenums. 602.2.1.2 Fire sprinkler piping. Plastic fire sprinkler piping exposed within a plenum shall be used only in wet pipe systems and shall have a peak optical density not SECTION 602 greater than 0.50, an average optical density not greater PLENUMS than 0.15, and a flame spread of not greater than 5 feet (1524 mm) when tested in accordance with UL 1887. 602.1 General. A plenum is an enclosed portion of the building Piping shall be listed and labeled. structure that is designed to allow air movement, and thereby serve as part of an air distribution system. Supply, return, ex- 602.2.1.3 Pneumatic tubing. Combustible pneumatic haust, relief and ventilation air plenums shall be limited to un- tubing exposed within a plenum shall have a peak optical inhabited crawl spaces, areas above a ceiling or below the floor, density not greater than 0.50, an average optical density attic spaces and mechanical equipment rooms. Plenums shall not greater than 0.15, and a flame spread of not greater be limited to one fire area. Fuel -fired appliances shall not be in- than 5 feet (1524 mm) when tested in accordance with stalled within a plenum. UL 1820. Combustible pneumatic tubing shall be listed 602.2 Construction. Plenum enclosures shall be constructed and labeled. of materials permitted for the type of construction classifica- tion of the building. 602.2.1.4 Combustible electrical equipment. Combus- tible electrical equipment exposed within a plenum shall The use of gypsum boards to form plenums shall be limited have a peak rate of heat release not greater than 100 kilo - to systems where the air temperatures do not exceed 125 °F watts, a peak optical density not greater than 0.50, and an (52 °C) and the building and mechanical system design condi- average optical density not greater than 0.15 when tested lions are such that the gypsum board surface temperature will in accordance with UL 2043. Combustible electrical be maintained above the airstream dew -point temperature. Air equipment shall be listed and labeled. plenums formed by gypsum boards shall not be incorporated in air - handling systems utilizing evaporative coolers. 602.3 Stud cavity and joist space plenums. Stud wall cavities 602.2.1 Materials exposed within plenums. Except as re- and the spaces between solid floor joists to be utilized as air ple- quired by Sections 602.2.1.1 through 602.2.1.4, materials nums shall comply with the following conditions: exposed within plenums shall be noncombustible or shall 1. Such cavities or spaces shall not be utilized as a plenum have a flame spread index of not more than 25 and a smoke- for supply air. developed index of not more than 50 when tested in accor- dance with ASTM E 84. 2. Such cavities or spaces shall not be part of a required fire - resistance -rated assembly. Exceptions: 3. Stud wall cavities shall not convey air from more than t 1. Rigid and flexible ducts and connectors shall con- one floor level. form to Section 603. 4. Stud wall cavities and joist space plenums shall comply 2. Duct coverings, linings, tape and connectors shall with the floor penetration protection requirements of the conform to Sections 603 and 604. International Building Code. 2002 WISCONSIN ENROLLED COMMERCIAL BUILDING CODE M-49 Page 1 of 1 Dannhoff, Allyn J. From: Tim Bolwerk [Tim.Bolwerk @omnni.com] Sent: Tuesday, February 12, 2008 1:17 PM To: Ialugo @pbsj.com; ctbxaviation @aol.com; Dannhoff, Allyn J. Cc: maleiner @pbsj.com; SShafie @pbsj.com; Phil Ramlet Subject: Wittman Tower - Cab Glazing Luis /Brian - Spoke to Allyn Dannhoff, Director of Inspection Services for the City of Oshkosh, today regarding an interpretation of the IBC 2400 code regarding the tower glazing and the potential of using annealed insulated glass vs laminated insulated glass for the tower glazing since we are now at a 20 degree angle vs. a 15 degree angle. The code has an exception that allows annealed glass to be used at an angle greater than 15 degrees if "walking surface below the glazing material is permanently protected from the risk of falling glass." I explained to Allyn that the original intent of the design and construction was to have the cab glass installed at 15 degrees but through the design and shop drawing review process we ended up with the glass at a 20 degree angle from the vertical. As a result of the higher angle from the vertical, we were required by code to go to a laminated glass, and because of the existing design, we were looking at laminated insulated glass verses just laminated glass. I also explained that in using this type of glass, there was a concern from FAA about the potential for double imaging and as a result we were looking into the potential for a waiver from using a laminated insulated glass vs. using the planned annealed insulated glass. Based on this intention, we were looking for an interpretation of the IBC 2400 code, specifically the exceptions listed in IBC 2405.3. After discussing with Allyn, there are basically two items that Allyn would not be comfortable granting a waiver for. The first is that both the ground and the catwalk could be considered walking surfaces that would need to be protected and how would we do that; the second is that even if only the ground was considered the walking surface and the existing catwalk was enclosed on the bottom and sides, AIIyn would not be comfortable that this enclosure would provide enough protection to keep glass from falling outside the catwalk. As a result, AIIyn indicated that we would need to stay with the laminated insulated glass option or a laminated glass option. If you have any questions on this, please give me a call. Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 2/12/2008 Page 1 of 1 Dannhoff, AIIyn J. From: Dannhoff, Allyn J. Sent: Tuesday, July 08, 2008 8:22 AM To: ' tim. bolwerk@ omnni .com ;'scottjscherer @faa.gov' o� z Cc: Benner, Kevin; Wolf, Paul T. Subject: Control Tower Tim and Scott, I apologize for not being able to get this out till now. The following is a sum ary of what remains to be accomplished to secure the Occupancy Permit. 1. Install all Fire Extinguishers Submit Building and HVAC Compliance Statements w 3. Provide a copy of the Precast Plan Approval Letter from the state./ 4. Explain why Fire Shutter door did not release when the smoke alarms in the Elevator lobby area were tested. 5. Provide correspondence from Northern Electric taking responsibility (vouch) for electric performed by others (FAA.) Correct all items on the Electric Correction Notice dated 6/30 (to our understanding this is in progress.) ✓ 6. Others performing electric work must secure their own permits. (Shindler Elevator) Please note a Correction Notice (dated 7/3 has been faxed to Shindler on 7/7) 7. complete.ttrak platform for / the chiller. ✓ 8. Secure Electric Old Plumbincj These are what we have noted as being the outstanding items to complete to secure Occupancy Approval. Call if you have questions. Allyn Dannhoff 920 - 236 -5045 cc i- 7/8/2008 r - Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 6/19/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time request line / Pouring slab on grade Thurs & Fri, 6/21 & 6/22 - DatelTime requested: 6/19/2007 _08:32 AM Notice Type: Ready DatelTime: 6/21/2007 Access: IL — — 1 Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 969 -7696 O Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Date 12/20/2007 : Type Rough In Inspector Allyn Dannhoff approved REQUEST LINE / READY FOR A FRAMING INSPECTION - WOULD LIKE TO SHEET ROCK FRIDAY 12/14/07 1 PLEASE CALL ERIC HE WOULD LIKE TO BE PRESENT FOR THE INSPECTION RI and Insulation - No concerns noted. Need to research wiring methods for floor /air supply cabinets in the control cab. Spoke to Eric on 12/21/07 - No different requirements between return & supply plenums- - - -- _ _ - -- - -- - - - - - -- -- - - - - -- Date /Time requested: 12/12/2007 03:13 PM Notice Type: Ready Date/Time: 12/12/2007 03:13 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: (920) 969 -7696 Q Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 1/25/2008 : - Type Consultation Inspector Allyn Dannhoff no time 1REQUEST LINE / READY FOR AN ABOVE CEILING INSPECTION TO LOOK AT THE VARIOUS MECHANICALS AND THE CAB ACCESS AREA. Talked to Jerry and told him I would not be able to make inspection. � I Date /Time requested: 1/24/2008 08:42 PM Notice Type: Ready DatelTime: 1/30/2008 00:00 Access: ONSITE 7A -330P Thru the gate to the temporary wood door Requested By: MIRON CONSTRUCTION CO INC - Jerry Phone Number: (920) 969 -7624 J Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid //� Date : Type Final Inspector Allyn Dannhoff �� : 1 � �REQU T LINE /WOULD LIKE A BUILDING GENERAL INSPECTION (FINAL ?) b lyik a l t eLJ S eft Pt a Date /Time requested: 4/17/2008 10:38 AM Notice Type: Ready Date /Time: 4/24/2008 00:00 AM Access: Enter through the hollow metal doors on the east or west side of the tower (doors open from 7am -330p Monday - Friday) E ERED Requested By: MIRON CONSTRUCTION CO INC - Jerry _ Phone Number: (920) 969 -7624 0 J Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid /, . • 7/2/t 7 v0�, �Fo Page 4 of 4 / �� -7/zzlog 14 0 4-b Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County-New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 4110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 5/23/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time Request line / Pouring foundation walls at 2:OOpm I I Date/Time requested: 5/22/2007 11:57 AM Notice Type: Ready Date /Time: 5/23/2007 Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 0 Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/25/2007 Type Footings Inspector Allyn Dannhoff no time Request line 1 Pouring interior footings at 2:OOpm Date /Time requested: 5/23/2007 12:19 PM Notice Type: Ready Date/Time: 5/24/2007 02:00 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: none given O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/25/2007 Type Footings Inspector Allyn Dannhoff no time Request line / Pouring interior footings on Tues 5/29 Date /Time requested: 5/25/2007 11:33 AM Notice Type: Ready Date /Time: 5/29/2007 : Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/31/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time Request line / Pouring interior foundation at 2:00 Thurs & Fri 5/31 & 6/1 - Date /Time requested: 5/30/2007 02:00 PM Notice Type: Ready Date/Time: 5/31/2007 02:00 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 3 of 4 Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 13110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date 5/15/2007 Type Footings Inspector Allyn Dannhoff no tim Request line / Pouring at 1:30 Date /Time requested: 5/15/2007 - 09:49 AM Notice Type: Ready Date/Time: 5/16/2007 01:30 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date 5/17/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time REQUEST LINE / POURING THE FOUNDATION WALL AT 1:30 ON 5/17/07 L... DatelTime requested: 5/16/2007 11:21 AM Notice Type: Ready Date /Time: 5/16/2007 11:21 AM Access: Requested By: MIRON CONSTRUCTION - ERIC WELLHOUSE Phone Number: (920) 969 -7969 O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 5/21/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time REQUEST LINE / READY FOR A BACKFILL INSPECTION ON THE FOUNDATION WALLS AND YOU CAN CHECK THE INSULATION - WILL BE POURING MORE FOUNDATION WALLS ON MONDAY 5/21/07 AT 1:30PM Date /Time requested: 5/18/2007 09:26 AM Notice Type: Ready Date /Time: 5/18/2007 09:26 AM Access: Requested By: MIRON CONSTRUCTION CO INC - ERIC Phone Number: (920) 969 -7696 O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 5/21/2007 Type Foundation Backfill Inspector Allyn Dannhoff no time Request line __ - -- — i Date /Time requested: 5/21/2007 11:04 AM Notice Type: Ready Date /Time: 5/22/2007 01:30 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 2 of 4 Building Permit Work Card Job Address 3110 -3130 KNAPP ST Permit Number 0123939 Create Date 3/22/2007 Owner WINNEBAGO COUNTY Contractor MIRON CONSTRUCTION CO INC Category 270 - Winnebago County -New Plan X7- 1938 -0307 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 1B Use /Nature 3110 Knapp St / Construct new airport control tower per State Approved Plans Trans ID # 1337446 of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date • Type Foundation Backfill Inspector Allyn Dannhoff Phone call to AIIyn - Pouring mud slab on Wed. 5/2 and rebar pourings the rest of the week. Date /Time requested: 4/30/2007 01:59 PM Notice Type: Ready Date /Time: 5/2/2007 PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920 - 969 -7696 O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Date 5/10/2007 : AM Type Foundation Backfill Inspector AIIyn Dannhoff approved Phone call to AIIyn - Will pour the tower slab on Tues. 5/9. Will call before to confirm the pour. No concerns noted (tower base). Base is poured - discussed details with Eric. Date /Time requested: 4/30/2007 01:59 PM Notice Type: Ready Date /Time: 5/9/2007 : PM Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 910- 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date • Type Note Inspector AIIyn Dannhoff UPDATE: Will pour tower base Tues morn 5/9 and some backfilling and excavating. Friday will do backfilling and Monday 5/14 excavating for 4' frost walls. Date /Time requested: 5/7/2007 : AM Notice Type: Ready Date /Time: • Access: Requested By: MIRON CONSTRUCTION CO INC - Eric Phone Number: 920- 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Date • Type Footings Inspector AIIyn Dannhoff REQUEST LINE / READY FOR A FOOTING INSPECTION * *WILL POUR TOMORROW 5/15/07 AT 1:30PM ** I L Date /Time requested: 5/14/2007 09:28 AM Notice Type: Ready Date/Time: 5/14/2007 09:28 AM Access: Requested By: MIRON CONSTRUCTION CO INC - ERIC Phone Number: (920) 969 -7696 O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 1 of 4 Page 1 of 2 Dannhoff, Allyn J. From: Tim Bolwerk [Tim.Bolwerk @omnni.com] Sent: Wednesday, July 23, 2008 4:01 PM To: Dannhoff, Allyn J. Cc: Benner, Kevin; Wolf, Paul T.; Michael .Schmid @Miron - Construction.com; terry.ripp @dot.state.wi.us; scott.j.scherer @faa.gov Subject: RE: Control Tower - Outstanding Item Responses required for Occupancy Permit Attachments: RE: Control Tower - compliance items ; Itr_ 071708 _dcom_precast_approval.pdf; compliance_statement_building.pdf Allyn - Responses to the items you have listed in your July 8 e -mail regarding the Occupancy Permit are given below. 1. Fire extinguishers have been installed as required. 2. A scanned copy of the Building and HVAC Compliance Statement is attached to this e-mail. 3. A scanned copy of the Precast Plan Approval Letter from the State is attached. 4. The fire shutter door did not release at the time of testing the smoke alarms in the lobby as the fire shutter door was deactivated at the time of the smoke alarm test so the door would not close on anyone. The door was tested by A & A Security and this test result will be included in their test documentation. Also, the fire shutter has been reactivated. Please see the attached e-mail string between Bill Seronko from Northern Electric and myself regarding the fire shutter door. 5. Kevin Benner has been in contact with Northern Electric regarding the work done by FAA. The work has been reviewed by Northem Electric and Kevin Benner did discuss with Northern Electric in addition to doing a follow up inspection on the work today, July 23. No additional items were noted by Kevin. The low voltage permit fee was to be mailed by Northern either late yesterday or today. 6. Schindler has sent in the required paperwork for doing electrical work in the City and will be sending in the permit and fees. FAA has contracted with Northern Electric to review FAA work and submit fees. 7. The work platform for the chiller was performed by August Winters, however, the platform was less than 36" deep. An e-mail has been sent to Miron Construction indicating that the platform depth will need to be corrected. 8. Plumbing approvals have been obtained. Electrical approvals have several items remaining to be completed after meeting with Kevin Benner this morning, July 23. An e-mail was sent to Miron Construction today itemizing the items that remain to be completed. We will continue to diligently work to complete the items on the list. These items will also be included on a punch list for the building until they are completed or resolved. Kevin Benner indicated that he thought that none of the items on the list that remain would hold up getting an occupancy permit, however, we do need to get the items finished up a quickly as possible. If there is any additional information you need or clarification on anything, please let me know. Miron Construction and OMNNI will continue to take care of any items remaining both on the electrical list and the punch list that was developed for the building by OMNNI. As previously noted, any items remaining on the electrical list will be put on the building punch list to be completed. If the above explanations are satisfactory, please forward the Occupancy Permit to me and I will forward to Miron, Winnebago County and FAA. Thanks Allyn! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Dannhoff, Allyn J. [mailto:adannhoff©ci.oshkosh.wi.us] Sent: Tuesday, July 08, 2008 8:22 AM To: Tim Bolwerk; scottjscherer @faa.gov Cc: Benner, Kevin; Wolf, Paul T. Subject: Control Tower 7/23/2008 Page 2 of 2 Tim and Scott, I apologize for not being able to get this out till now. The following is a summary of what remains to be accomplished to secure the Occupancy Permit. 1. Install all Fire Extinguishers 2. Submit Building and HVAC Compliance Statements 3. Provide a copy of the Precast Plan Approval Letter from the state. 4. Explain why Fire Shutter door did not release when the smoke alarms in the Elevator lobby area were tested. 5. Provide correspondence from Northern Electric taking responsibility (vouch) for electric performed by others (FAA.) Correct all items on the Electric Correction Notice dated 6/30 (to our understanding this is in progress.) 6. Others performing electric work must secure their own permits. (Shindler Elevator) Please note a Correction Notice (dated 7/3 has been faxed to Shindler on 7/7) 7. complete the work platform for the chiller. 8. Secure Electric and Plumbing Approvals. These are what we have noted as being the outstanding items to complete to secure Occupancy Approval. Call if you have questions. Allyn Dannhoff 920 - 236 -5045 7/23/2008 Page 1 of 3 Dannhoff, Allyn J. From: Bill C. Seronko [Bill @nei- gb.com] Sent: Monday, July 14, 2008 3:13 PM To: Tim Bolwerk; Michael .Schmid @Miron- Construction.com Cc: cgrams @mironconst.com; terry.ripp @dot.state.wi.us Subject: RE: Control Tower - compliance items Tim, The shutter door test reports will be in with A &A's Fire Alarm Test Report. The door has been left energized and in working order. The circuit determined for the door did not change from the base bid drawings as the circuit is shown, and only the smoke detectors were actually extra work. Please let me know if you have any questions, thanks! Bill Seronko Project Manager Northern Electric Inc. 314 N. Danz Avenue Green Bay, WI 54302 -3526 P 920- 468 -6000 F 920 -468 -7705 www.nei - gb.com "We put the power in your hands" From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Saturday, July 12, 2008 10:54 AM To: Bill C. Seronko; Michael .Schmid @Miron- Construction.com Cc: cgrams @mironconst.com; terry.ripp @dot.state.wi.us Subject: RE: Control Tower - compliance items Bill - Do we have any documentation on the test of the fire shutter door such as who tested it and when. Also, has the door been reactivated since all of the testing? If we have documentation, I should get that to the building inspector. Lastly, since wiring the fire shutter door to the fire alarms was additional work, do your as builts show what circuit this fire shutter is wired up to? Let me know. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Bill C. Seronko [mailto:Bill @nei- gb.com] Sent: Tuesday, July 08, 2008 3:00 PM To: Tim Bolwerk; Michael .Schmid @Miron- Construction.com Cc: cgrams @mironconst.com; terry.ripp @dot.state.wi.us Subject: RE: Control Tower - compliance items Tim, 1 checked with Mike King, he said that door was tested, and it worked. He thought the control relay for the door was deactivated at test time so as the door would not close on anyone during the fire alarm testing. Thank you. 7/23/2008 Page 2 of 3 Bill Seronko Project Manager Northern Electric Inc. 314 N. Danz Avenue Green Bay, WI 54302 -3526 P 920 - 468 -6000 F 920 - 468 -7705 www.nei - gb.com "We put the power in your hands" From: Tim Bolwerk [mailto:Tim.Bolwerk @omnni.com] Sent: Tuesday, July 08, 2008 9:44 AM To: Bill C. Seronko; Michael .Schmid @Miron- Construction.com Cc: cgrams @mironconst.com; terry.ripp @dot.state.wi.us Subject: FW: Control Tower - compliance items Mike /Bill - Attached is a list received from Allyn Dannhoff from the City of Oshkosh regarding items we would need to complete in order to get occupancy for the tower. I have a call in to Allyn to see if we can get conditional occupancy if not every item is complete before EAA. As far as who needs to get the individual items complete, that is as follows: 1. Fire Extinguishers - Miron - Should be done as the extinguishers were on site. 2. Compliance Statements - OMNNI -Tim B. 3. Precast Plan Approval Letter - OMNNI - Tim B. 4. Fire Shutter Release Explanation - Northern Electric - This is in reference to why the shutter door did not close when the fire alarms were set off. (Bill S.- I believe this was because the fire shutter door is activated by a fusible link but could you please verify) 5. Review of FAA electrical installation and permits - Northern Electric 6. Electrical permit for elevator work - Schindler Elevator 7. Chiller Platform - will get revised sketch to Mike Schmid today. This would either need to be done by Miron or August Winters. 8. Plumbing Approvals - Need to move one condensate line in janitors closet (August Winters) and submit backflow preventer test results to City (S & S Mechanical) 9. Electrical Approvals - Please see electrical inspection report dated 6/30/08 as received from Kevin Benner from the City of Oshkosh. This list is a combination of corrections for Northern Electric (3 items), FAA (4 items), August Winters and August Winters sub, Johnson Controls (4 items), and Miron (1 item). l know the one item that was on the list for Miron has been completed (access to the electrical equipment in the elevator control room). There were other items on the fire department and OMNNI punchlist, but many of these items have also been taken care of plus they would not affect occupancy. If you have any questions, please give me a call. Thanks! Tim Bolwerk, P.E. OMNNI Associates, Inc. One Systems Drive Appleton, WI 54914 Phone (920) 830 -6150 Fax (920) 830 -6100 From: Dannhoff, Allyn J. [ mailto :adannhoff @ci.oshkosh.wi.us] Sent: Tuesday, July 08, 2008 8:22 AM To: Tim Bolwerk; scottjscherer @faa.gov Cc: Benner, Kevin; Wolf, Paul T. Subject: Control Tower Tim and Scott, 7/23/2008 Page 3 of 3 I apologize for not being able to get this out till now. The following is a summary of what remains to be accomplished to secure the Occupancy Permit. 1. Install all Fire Extinguishers 2. Submit Building and HVAC Compliance Statements 3. Provide a copy of the Precast Plan Approval Letter from the state. 4. Explain why Fire Shutter door did not release when the smoke alarms in the Elevator lobby area were tested. 5. Provide correspondence from Northern Electric taking responsibility (vouch) for electric performed by others (FAA.) Correct all items on the Electric Correction Notice dated 6/30 (to our understanding this is in progress.) 6. Others performing electric work must secure their own permits. (Shindler Elevator) Please note a Correction Notice (dated 7/3 has been faxed to Shindler on 7/7) 7. complete the work platform for the chiller. 8. Secure Electric and Plumbing Approvals. These are what we have noted as being the outstanding items to complete to secure Occupancy Approval. Call if you have questions. Allyn Dannhoff 920 - 236 -5045 7/23/2008 BUILDINGS, HVAC, COMPLIANCE STATEMENT SBD-9720 This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) observing construction of projects within buildings with total areas 50,000 cubic feet or greater and bleachers (Comm 50.10/Comm 61,50). Failure to submit this form may result in penalties as specified in Comm 50.26/Comm 61.23 and/or local ordinances. This form must be submitted prior to the plan approval expiration date or another submittal may be required. General Instructions: Prior to the initial occupancy of new buildings or additions and the final occupancy of altered existing buildings, submit this completed and signed form to: • The municipal building inspection office {refer to the plan approval letter for agency address and • Safety and Buildings, 10541N Ranch Road Hayward, M. 54843 Note: If the review was done by the municipality, the compliance statement goes only to the municipal building inspector. A copy is not needed by Safety & Buildings. Personal information you provide may be used for secondary purposes [Privacy Law, s. 15.13 (t)(mg, 1. PROJECT INFORMATION: Please fill in the following with information from your plan approval letter. Transaction ID Number 43 3 7 Project Name Vi 771yAki lV,4 Aire Site Number l 96, 75 141>t r:e4c, c Site location (number & street) k..0 57 r Igi City 0 Village 0 Town of 0541,14_4,),S 11 County of 1,,Aft.A.44.7.(464 2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or O indicate purpose and complete any other applicable boxes and information. Attach additional pages if necessary.) Check those which apply: ti(Building Object ID # PO 4 7 1 75 ,HVAC Object ID # yeio 0 Lighting Object ID # 0 Partial Completion Description of Portion Completed A) A Statement of Substantial Compliance To the best of my knowledge, belief, and based on onsite observation, construction of the following building and/or HVAC items applicable to this project have been completed in substantial compliance with the approved plans and specifications. z, BUILDING/LIGHTING ITEMS 1. Structural system including submittal and erection of ail building components 10. Exterior lighting & control requirements (trusses, precast, metal building, etc.) 11. Interior lighting & control requirements 2. Fire protection systems (sprinklers, alarms, smoke detectors) designed, installed, 12. All conditions of lighting plan approval and tested (including forward ftow an back flow devices) by appropriately and applicable variances registered professionals 3. Shaft and stairway enclosure 4. Exits including exit and directional lights 5. Fire constrtiction, enclosure of hazards, fire walls, labeled doors, class 0 HVAC ITEMS of construction, fire stopped penetrations O. Sanitation system (toilets, sinks, drinking facilities) 1, HVAC system including final test 7, Barrier-free including Comm 18 elevators and lifts 2. All conditions of HVAC plan approval and 8. Energy envelope requirements applicable variances 9. Alt conditions of building plan approval and applicable variances The following items are not in compliance and must be addressed: B) 13 Statement of Noncompliance Due to the following listed violations, this project is not ready for occupancy: C) 13 Supervising Professional Withdrawn From Project (Use A or 13 above to incficate project status as of this date.) D) 0 Project Abandoned 3. SUPERVISING PROFESSIONAL SIG;MWRE k Building HVAC 0 Lighting ` /L Date 7/ 9,2-cr Name (please print or type) Phone number g:fo- 4456 Customer 10# Signature SBD-9720 (R,04/2005) Safety and Buildings PO BOX 7162 commerce.Wl.gov MADISON WI 53707 -7162 TDD #: (608) 264 -8777 if isconsi n www•commerce.wi.gov /sb/ www.wisconsin.gov Department of Commerce Jim Doyle, Governor Jack L. Fischer, A.I.A., Secretary July 17, 2008 CUST ID No. 1081480 ATTN: Buildings & Structures Inspector BUILDING INSPECTION CLARK MEYER CITY OF OSHKOSH ONE SYSTEMS DR POB 1130 APPLETON WI 54914 OSHKOSH WI 54902 COMPONENT RECEIVED Identification Numbers Transaction ID No. 1489486 SITE: Site ID No. 146753 Wittman Regional Airport Please refer to both identification numbers 525 W 20TH Ave - Knapp above, in all correspondence with the agency. City of Oshkosh, 54902 ; Fire Dept ID: 7003 FOR: Facility: 505465 WITTMAN REGIONAL AIRPORT 525 W 20TH ST OSHKOSH 54902 Object Type: Precast Plank Regulated Object ID No.: 1164430 Code Applies Date: 12/05/07 Object Type: Precast Wall Regulated Object ID No.: 1164431 Code Applies Date: 12/05/07 The department has received the above component plan indicated as being reviewed for compliance with the general design concept and submitted by the building designer named above. The Department has filed the plans and other related documents. The department will rely on, and hold responsible, the building design professional and/or supervising professional of record for compliance with the rules. The responsible professional should particularly insure that proper loads and fire resistive rating have been incorporated to correspond to the building design. Particularly insure: proper dead and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper bearing/supports, concentrated loads etc, are properly conveyed to founda ions; and that required fire ratings have been employed. The submitted materials have not been reviewed by the Department for co pliance with all applicable administrative rules. The department reserves the right to formally review the plans in th future if the department determines that such a review is warranted, and to order corrective actions with respect to he outcome of that review. A copy of the plan that is identical to the plan submitted for our file shall e available for inspection at the job site. When the total building volume exceeds 50,000 cubic feet, the plan all bear an indication of review that has been signed or initialed by the building designer of record. Inquiries concerning this correspondence may be made to me at the teleph ne number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the egarding line when making an inquiry or submitting additional information. ECEIVED JUL 21 2008 DEPARTMENT OF NITY OF'M INSPECTTON COMMU SERVICES DEVEti DIVISION CLARK MEYER Page 2 7/17/2008 Sincerely, Fee Required $ 300.00 Fee Received $ 300.00 Balance Due $ 0.00 Diane C Morris Program Assistant 4 , Integrated Services WiSMART code: 7648 , 8:00 a.m. To 4:30 p.m. diane.morris @ wisconsin. gov cc: John R Anderson, State Building Inspector, (715) 823 -2014 , Monday,7:45A.M.- 4:30P.M. Ruth Ellioit, Wittman Regional Airport Omnni Assoc