CERTIFICATE OF COMPLIANCE
CERTIFICATE NUMBER 070303- R13240H
ISSUE DATE: March 7, 2003 Page 1 of 1
Issued to: Hilti Construction Chemicals, div. of Hilti Inc.
5400 S 122nd East Avenue
Tulsa, OK 74146
Report Reference: R13240, March 17, 1997
This is to Certify that
representative samples of: Foam Materials designated as FS -Fire Block (also identified as FS657)
Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated
on this Certificate.
Standard(s) for Safety:
ANSI/UL 1479, Fire Tests of Through - Penetration Firestops
Additional Information: CP618 Foam Material intended for use as a Classified Fill, Void or Cavity
Material for use in various Through - Penetration Firestop Systems as specified in
UL's Fire Resistance Directory Volume 2.
Only those products bearing the UL Classification Marking should be considered as being
covered by UL's Classification and Follow -Up Service.
O
The U], Classification Marking includes: U1, in a circle symbol: with the word "CLASSIFIED" (as shown); a control number (may be
alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name (product
identity) as indicated in the appropriate Ul,Directory. m
to
`
Engineer: I . Review Engineer: •
Robert S. Lukasz Richard N. Walke
Underwriters Laboratories Inc.
Underwriters -
ers Laboratories Inc. r —
m
to
m
n
D
A not- for - profit organization
dedicated to public safety and
committed to quality service
Saving Lives through innovation & education i Hilti Firestop Guide 2003 -2004 ! 1 -800- 879 -8000 1 www.us.hilti.com 1..11`7• • 481
Page 1 of 2
Krahn, Nicole R.
From: Kevin Savitt [ksavitt @whgco.com]
Sent: Tuesday, September 02, 2008 3:43 PM
To: Krahn, Nicole R.
Cc: Dave W.'
Subject: Otis Raceway At Comfort Suites Oshkosh
Attachments: Hilti Certificate.pdf
Dear Inspector Krahn,
I hope this email finds you well.
Did you review the text and attachment from Fred Wagner of Otis Elevator?
If so, is it OK?
Please let me know.
Thanks,
Kevin Savitt
920.312.4582
From: Wagner, Fred W. [mailto:Fred.Wagner @otis.com]
Sent: Thursday, June 12, 2008 1:36 PM
To: Kevin Savitt
Subject: RE: Comfort Suites Oshkosh
Kevin here is the info you needed.
From: Kevin Savitt [mailto:ksavitt@whgco.com]
Sent: Wednesday, June 11, 2008 3:22 PM
To: Wagner, Fred W.
Cc: 'Krahn, Nicole R.'; 'Dave W.'
Subject: Comfort Suites Oshkosh
Fred,
The Building Inspector will need your UL sheet for the firestopping you will install in Oshkosh at the Comfort
Suites.
This is Nicole's exact text from past inspection report,
Provide information on the 2 hour firestops for the elevator tracking that penetrates the 2 hour masonry and
drywall assembly.
9/3/2008
Page 2 of 2
s
" can Division
in g Sy St I
u.e , (9 -5050 1 wortc
.20 0 -St}"
' a .US
Y
Thanks for your help.
Kevin
\\ 1f,
Kevin Anthony Savitt
Project Manager
920.312.4582 Mobile
WA Construction, LLC
404 N Main Street
Suite #101
Oshkosh, WI 5
920.237.0233 X108
866.403.7287 FAX
ksavitt @whgco.com
www
9/3/2008
09/03/2008 13:56 FAX 920 766 2910 OTIS ELEV KAUKAUNA V1001/001
i
ri , t j ti 7 i r • 7,7 t r 4.l 73 e -7•':--7 t ' f � 7 4 , of ", ,,] .7 ,�+ 4 y 7 ri -,. '•I .
v I J r :. ..5• ','.1— �. .. h ' .. k i+ r .J; .�A " 4 i p {: „r 12 ! 4 i ~7 ' f , y .1, ��+ N 7 . ”,
Ara FS 657 FIRE B �... .t, r .. e: ., �.1� ..� � .-� . �..r'� o_ .'.;, �
LOCK :, . � � � ry > >
-
` r Iv
•
'' r r ;11' 4 '" product description (L Q Ed 14C)
- I ,>,,..,.;:' , ' • Ready -to -use, intumescent flexible block based on a
two-component polyurethane foam
I ' . Areas of application
:1 i ;,,'„ • Sealing single or multiple penetrations In small to large openings
�` • Temporary or permanent sealing of cable a nd cable
` penetrations
' , • • Temporary or permanent sealing of in and non-Insulated
_ _ metallic pipes and combustible pipe penetrations
r -_ P Temporary or permanent sealing of blank openings ngs
r: • . ! .. � � - use with
rr ', d ~ ., • Walls (UL tested up to maximum opening 52 " ")
i'; ; • Floors (UL tested up t0 maximum opening 36" x 38 ")
• ' •,',f �" • , • Concrete, porous concrete, masonry and gypsum wall
„ ,
J ;:'., dupto4hours
• assemblies rate 9YA assemblies
Technical Data (at 78 °F / 29 °C and 501e relative humidity) • Floor assemblies rated up to 3 hours
i • Density AREG 0.25 p/cm' _____
' • Dimensions: 2" x 5"x
: x s" Examples
i'-'• � • Color. Red • Completely dust and fiber -free rooms and places where
:,, ! :, A Ilcatlon fete erature: 23 °F to 104 °F /-5 °C to 40 °C elect{rcal installations are frequently used, such as computer
Temperature resistance: —60 °F to 140 °F /-51°C to +60 °C Beers, hospitals and laboratories
mp
•New buildings In the construction phase and during renovation
IntumescentActivation: roc. 300 °F 1149 °C
_ „ S Expansion ratio (unrestricted): Up to 1:5 • Large openings containing multiple penetrations as found
urface burning characteristics: Flame Spread Index: 0 In production bays, warehouses, hospitals etc.
fAsTIA 5 84 -96) Smoke Development index: 25 Tested In accordance with
A •
Arolrals • UL 1479
_.:,1060 Evaluation Service Inc. Report No. 5071 • ASTM E 814
' „C�ifornia State Flre Marshal patina No. 1200 :106 — • ASTM E 84
j! of New York MEA 325 -96 -M
System Advantages
internationally tested and approved • Suitable for both new and re- penetrations
'c� ow% muocO IFl�9r mma • Short lnstalla8ontimes
� `Easy installation--no special tools required :,
9Q�7 PMpROPBY91 • Ideal for use In }lours -- no forming Is required
i
° {EUL��9}F r �APPROYE° r
9 °'' °p•t• - r�r �, ., • 1 0096 dust and fiber free
t ' • Halogen, asbestos and solvent free
:,;' • Operational upon installation
: t ; • Can be Painted
- t
4
, .
;' 1 '2' k
+rq Inf ortnetion r i i r
FS FFS FIRE BLOCK Red 0 Ina
S .(r)
Red 80 in
�I
i l
For complete flrestop technical Information, rarer to the NMI Rrostop Contact your Hilt Sales Representative or b Service for your Specification,
copy today.
,' 'Tki llfreLus.blitt.com I Customer Service 1- Ono- s7s -aeoe (M-F, 6:00 am — 8:00 pm CST) I eallrrUse. in every case, TM 1