Loading...
HomeMy WebLinkAboutVentilation Calcs - 11/21/2002 NOV -21 - 02 THU 02:48 PM BREWER HEATING FAX:19207486520 PAGE 1 FAX COVER SHEET ' � I- ()P2- Brewer heating Inc. t n N8804 N. Douglas St. Ripon, WI 54971 y5 Phone:(920) 748 -6494 Fax:(920) 748 -6520 No. of pages: (including cover sheet) c TO: A \ ■.a 01`x►? FROM; 1)6 '� RE: f , 3 o �o 1 C. �J ' s (TiRr¢ W bib f�- cs�.�.c.e - rt • S , 5 4r1 r0 -0+-r -17-5 i 16.6e. 1`. , „ r /l,k. k5 NOV -21 THU 02:48 PM BREWER HEATING FAX:19207486520 PAGE 2 NOV --21 -2002 1234 DESIGN AIR • .v3 Irii w r o . ly;;. P. 01/01 it . 4Illrl , .. ' . Y(>uVContylete 1 calins : & Cooling Wholesaler DESIGN AIR •A e ivisIOPl.OF U.S. OIL CO.. INC. 11/21 /2002 • Brewer Heating • Doug Brewer •` ' . • RE: Large house ventilation caleideiions ., • • . . • • Doug, Please recall our phone conversation today (Thursday 11121/2002) regarding a large home in which you were involved in providing°.the required ventilation. 'Wisconsin Code COMM . 23.02(30x2) states that passive intake air ductaproviding air for intermittent exhaust fans shall be sized to provide at least 40% of the total air that would be exhausted with all intermittent exhaust ventilation in the dwdtling•opeerating simultaneously. • Table 23.07 (duct velocities) allows outdoor intake ducts to be sized to accommodate a minimum duct velocity of 500 feet per minute and a maximum velocity of 800 feet per minute. The specific house that you had described had this following exhaust potential: Five (5) 50 *fin bathroom fans = total 250 CFM One large kitchen hood fan = 600 CFM ' ' Total potential exhaust CFM = 850 CFM , . 850 total CFM x .4 (40%) = 370 CFM A 10" round fresh air intake could• accommodate 370 CFM at a velocity of approximately 700 feet per minute. Therefore, a 10" nee area intake should be permissible. Once inside the house, you could branch off of the 10" round; intake pipe with three 6" round pipes leading to the existing I-IVAC equipment ductwork.,,.: eh : d ", pipe could accommodate approximately 125 CFM. Therefore you could meet and exceed, the fresh air intake requirements for the home based nn exhaust rates that you had informed me. . Please call me with any further questions. ,,i�' ` 44x04 tr °AV `r Sincerely yours, �,,���..��..+te..o��! "''�•,,�' .�,�/ Ap ^tZVEGSR A Ron Krueg - n_ien I 1 . Design Air 1 , ' KIIVIBERLY s Wisconsin Designer of tVAC Systems #D 1 0 83 -H . 3`s� Nil ,r ''. , i.).:. * " .0 / . r . 7 KIMBERLY BfREEN BAY : WESTAtWB IRON IIOUNTAII4, MI MILWAUKEE 1010 Kennedy Ave, 2050 S. A M A M I A W ' 4 1 2 2 5 W k M ( l 6 E l l m t 0 Clyd• Dr. 328 W. Florida St. P.O. Box 39 Grimm 90, WI 54304 - : 4,011 A4•W153214 1f4fl MCWItain.IA 49801 M4wai*ce. WI 51201 04 be4y, WI 54136 PH: 920.4944676 PH: 414966•7444 PH: 906. 7180810 PH: 414.2764677 PH: 820 - 736.7005 1- 900. 444.1795 1-0420-4944959 148004904904 1.600. 5683389 1400- 4440101 FAX: W0494.8875 PAX: 414255.4075 FAX: 606.776.0815 FAX 414 - 276 -55e9 FAX: 958.739-7570 TOTAL P.01