RE: Large house ventilation caleideiions ., • • . . •
•
Doug,
Please recall our phone conversation today (Thursday 11121/2002) regarding a large home in
which you were involved in providing°.the required ventilation. 'Wisconsin Code COMM .
23.02(30x2) states that passive intake air ductaproviding air for intermittent exhaust fans shall
be sized to provide at least 40% of the total air that would be exhausted with all intermittent
exhaust ventilation in the dwdtling•opeerating simultaneously. • Table 23.07 (duct velocities) allows
outdoor intake ducts to be sized to accommodate a minimum duct velocity of 500 feet per minute
and a maximum velocity of 800 feet per minute.
The specific house that you had described had this following exhaust potential:
Five (5) 50 *fin bathroom fans = total 250 CFM
One large kitchen hood fan = 600 CFM ' '
Total potential exhaust CFM = 850 CFM , .
850 total CFM x .4 (40%) = 370 CFM
A 10" round fresh air intake could• accommodate 370 CFM at a velocity of approximately 700
feet per minute. Therefore, a 10" nee area intake should be permissible. Once inside the house,
you could branch off of the 10" round; intake pipe with three 6" round pipes leading to the
existing I-IVAC equipment ductwork.,,.: eh : d ", pipe could accommodate approximately 125
CFM. Therefore you could meet and exceed, the fresh air intake requirements for the home based
nn exhaust rates that you had informed me. .
Please call me with any further questions. ,,i�'
` 44x04 tr °AV `r
Sincerely yours, �,,���..��..+te..o��! "''�•,,�'
.�,�/ Ap ^tZVEGSR A
Ron Krueg - n_ien I 1 .
Design Air 1 , ' KIIVIBERLY s
Wisconsin Designer of tVAC Systems #D 1 0 83 -H . 3`s� Nil ,r
''. , i.).:. * " .0 / .
r . 7
KIMBERLY BfREEN BAY : WESTAtWB IRON IIOUNTAII4, MI MILWAUKEE
1010 Kennedy Ave, 2050 S. A M A M I A W ' 4 1 2 2 5 W k M ( l 6 E l l m t 0 Clyd• Dr. 328 W. Florida St.
P.O. Box 39 Grimm 90, WI 54304 - : 4,011 A4•W153214 1f4fl MCWItain.IA 49801 M4wai*ce. WI 51201
04 be4y, WI 54136 PH: 920.4944676 PH: 414966•7444 PH: 906. 7180810 PH: 414.2764677
PH: 820 - 736.7005 1- 900. 444.1795 1-0420-4944959 148004904904 1.600. 5683389
1400- 4440101 FAX: W0494.8875 PAX: 414255.4075 FAX: 606.776.0815 FAX 414 - 276 -55e9
FAX: 958.739-7570
TOTAL P.01