Loading...
HomeMy WebLinkAbout0083428-Building C&I CITY OF OSHKOSH No 0083428 OSHKOSH BUILDING PERMIT APPLICATION AND RECORD ON THE WATER Job Address 474 WINDINGBROOK DR Owner JAMES R/BILLIE J MATHUSEK Create Date 12/11/2000 Designer Contractor D D CONSTRUCTION Category 110 New Single Family Plan C8- 124 -1200R Type 0 Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning R -1 Class of Const: 8 Size IRREGULAR Unfinished /Basement 1236 Sq. Ft. Rooms 8 Height 21 Ft. 0 Projection Finished/Living 3556 Sq. Ft. Bedrooms 3 Stories 1 Canopies Garage 802 Sq. Ft. Baths 2 Signs Foundation 0 Poured Concrete 0 Floating Slab 0 Pier 0 Other 0 Concrete Block 0 Post 0 Treated Wood Occupancy Permit Required Flood Plain Height Permit Not Required Park Dedication Required Dwelling Units 1 Structures 1 Use /Nature NSFR/ Constructing 2396 sf 1 -story residence with attached garage, paved driveway, and 13'x16' wood deck. of Work HVAC Contractor BREWER HEATING Plumbing Contractor AHERN -GROSS INC. Electric Contractor SCHOMMER ELECTRICAL CON Fees: Valuation $236,000.00 Plan Approval $75.00 Permit Fee Paid $813.00 Park Dedication $100.00 Issued By: Date 12/19/2000 Final /O.P. 0 Permit Voided In the performance of this work I agree to perform all work pursuant to rules goveming the described construction. 7 Signatur Date 1G G 7 3 Agent/Owner Address 100 ROLLING GREEN CIR Oshkosh WI 54904 0000 Telephone Number 232 -0059 CD OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6472 Name JAMES R/BILLIE J MATHUSEK Address 474 WINDINGBROOK DR Create Date 12/11/2000 Lot 30 Block Ward Subdivision SAWYER CREEK Zone Street Number Lot Dimensions 124' -7" X 125' IRREGULAR 1 f Sidewalk Existing Building Grade Elevation Stakes Set At Site 12/13/2000 Set By KN 563 /20 Department of Public Works 1, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0083428 P.O. Box 7969 APPLICATION Parcel No. Madison, WI 53707 Wisconsin Statues 101.63, 101.73 Q Constr HVAC Elec Plbg Q Erosion Other: Owner's Name Mailing Address Telephone No. JAMES R/BILLIE J MATHUSEK 100 ROLLING GREEN Oshkosh WI 54901 0000 Contractor: 12 Con III Elec II HVAC Plbg Lic/Cert Mailing Address Telephone No. D D CONSTRUCTION 663449 100 ROLLING GREEN CIR Oshkosh WI 54904 0000 232 -0059 Contractor:. Con Q Elec HVAC N Plbg Lic/Cert Mailing Address Telephone No. SCHOMMER ELECTRICAL CON N 164 TWO MILE ROAD APPLETON WI 54914 9121 920 731 -2299 Contractor:. Con II Elec Q HVAC U Plbg Lic/Cert Mailing Address Telephone No. BREWER HEATING 4220 N8804 N DOUGLAS STREET RIPON WI 54971 0000 (920)748-6494 Contractor: Con Elec II HVAC 0 Plbg Lic/Cert Mailing Address Telephone No. AHERN -GROSS INC. 218 S MAIN ST FOND DU LAC WI 54963 0000 920 921 -1414 Lot Area S•. ft. 1/4, 1 /4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 474 WINDINGBROOK DR SAWYER CREEK 30 Zoning District(s) Zoning Permit No. Front 1 Right Q New Repair 12 Single Family Entrance Panel 121 Forced Air Fumace Fuel Nat. Oil Elec. Solid Sola Alteration ❑Raze Two Family Size: 200 am. Radiant Baseboard or Panel Ga 111 Addition ❑Move El Garage Service: Heat Pump Space Htg 0 El I] Other (print): Overhead Boiler Water Htg 0 O ther 0 Unde Central Air Conditioning Dwelling unit will have 3 kilowatt or Other more installed electric space heating equip. 10 Site Constructed Q Concrete Infiltration control option Is 121 Full sealing Unfinished Manufactured Masonary Sewer Basement 1236 S Treated Wood of joints. El Blower door test. El Exterior Sq. ft. 0 Municipal air infiltration barrier. Other El Septic Living Area 3556 Sq. ft. 12 1- Story 2 -Story Permit No. Envelope 42255 BTU /HR Garage 802 Sq. ft. Other Seasonal Infiltration 29327 0 Permanent BTU /HR Other io Municipal Utility 0 Plus Basement Private On -Site Well $250,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or implied, the i i. unicipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATU DATE SIGNED Be) APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or revocation of this permit or other penalty SEE STANDARD CONDITIONS OF APPROVAL Town Village 0 City County State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 2 6 6 Plan Review $75.00 0 Construction Inspection III HVAC Name Shaun Scullion Wis. Permit Seal $30.00 Electrical Other III Plumbing Date 12/11/2000 0 Erosion Total $105.00 111 237971 Cert. No. 697254 SBD -5823 (R. 07/92) OSHKOSH (P PARKLAND DEDICATION FEE COLLECTION RECORD ON THE WATER Job Address 474 WINDINGBROOK DR Date 12/19/2000 Name JAMES R/BILLIE J MATHUSEK Address 100 ROLLING GREEN Oshkosh WI 54901 Subdivision SAWYER CREEK Lot 30 Building Permit Number 0083428 Number of Dwelling Units 1 Number of Structures 1 Fee Required $100.00 Fee Paid Owner's Signature Date /7 Inspector's Signature Date Z o CV II Q� J J L., le Y U 8 III Z as W t P 5 W V 3 W 3 Z d r. o a. tJ N _1 O 11� 0 ik 1.61 111 (U o O r Z La Z ce O Z Z J 0�0 a cc 3 00 0 v 1 111 s.a.tl1VU s 53'-9" In :R j 1 pi s Jill" a „il low' II I 1111 I 330 01 r H s ti ihf 11 O OW M1 1Oig N. R Ev 0 1 l ig 0 in 0 1 o n 0 in a i zd a I. I It, `t c+ a tO vO 1:1 g gi t is Y "u l 3115 NO 9N NI 01 3NI1 .30N3213332J s w N to i grIP if 1 :1-(- Sill r {tru( 79. -2 I w Z /l S-,S► a V 0 m 3 z S Z ZONING/LAND USE COMPLIANCE CHECKLIST JOB LOCATION: G L/IAC nc ireo ZONING iC PROPERTY OWNER/CONTRACTOR: Jcim s Sic.Jd.it CONSTRUCTION DATA: =New Construction Addition Alteration TYPE OF CONSTRUCTION: (Le. fence, pool, parking lot, sign, etc.) 42-5 COMPLIANCE CHECKLIST DEFICIENT COMMENTS Use Lot Width Lot Area Lot Area Per Family Fioodpiain Front Yard Front Yard Side Street Rear Yard Side Yards Building Area Parking Standards Off -Street Loading Standards Vision Clearance Transitional Yard Standards Landscape Standards Height Conditions of Approval Compliance with P.C. or BZA Conditions of Approval Signage Standards Drainage Plan REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approval all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc., when the use is conforming and no change is proposed. APPROVED DENIED Plan Commission Action Required Variance(s) Required REVIEWED BY: DATE: l�� CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address 1 17V 0. 4pPermit 213 d Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. 2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire resistive rating of 20 minutes. M1 drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness 1/20 -inch) and backed by solid wood or drywall with the joints staggered. 3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. 5. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 6. All overframing must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2 -3" diameter stone is required in addition to a minimum t of 6" de th, 3 V- 50'slength ,and "14; -20' width. Erosion control measures must be ie i establhed. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re- inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re- inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor. �ic�nafure o��trrCican obate: -©C