Loading...
HomeMy WebLinkAboutCertificate of Occupancy City of Oshkosh D�KO.� P.O. BOX 1130 OSHKOSH, WI 54902 -1130 rr WW ON THE WATER GOPV Approved: April 27, 2001 Issued: May 21, 2001 Boyd Karen Gibbs 474 Windingbrook Drive Oshkosh, WI 54904 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby granted for the new one story home with attached garage, paved driveway and deck located at 474 Windingbrook Drive, Oshkosh, Wisconsin 54904 as described in Building Permit Application number 83428. This building is to be used as a residential dwelling only and is located in the R -1 Single Family Residence District. LIMITATIONS: Maximum floor loading: 40 lbs. per square foot live load Maximum persons and /or living units: One living unit CONDITIONS: 1) Final grading must be done in accordance with the approved subdivision drainage plan. This plan is on file in the public works office, 3 floor of City Hall. 2) Erosion control measures must be maintained until the lawn is established. 3) Copies of inspection results are available upon request at City Hall, 2 floor room 205. NOTE: Final grade must be a minimum of 6" below all siding. A new Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land or buildings shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. i Nicole Krahn Building Systems Inspector Cc: D D Construction Krahn, Nicole R Subject: 474 WINDINGBROOK Start Date: Monday, January 01, 2001 Due Date: Friday, June 08, 2001 Status: In Progress Percent Complete: 25% Total Work: 0 hours Actual Work: 0 hours Owner: Krahn, Nicole R Requested By: Scullion, Shaun Categories: NEW HOME NEW SINGLE FAMILY D D CONSTRUCTION PERMIT #83428 ISSUED 12/11/00 1/8/01 NO TIME (SRS) FOOTINGS Received call from Penny Skotzke, would be pouring footings in the afternoon, between 12 and 2. 1/10/01 Received call from Jamie, informed that whole back side of structure will be exposed, due to the slope of the lot. He stated that he will be submitting new header and heat loss calculations. He will be adding 1 additional window. 1/11/01 PASS (SRS) FOUNDATION Footings covered with hay. Called Jamie and left message instructing not to pour basement floor until footings are inspected at rough inspection. Also mentioned to provide erosion control for soil stockpile near front lotline, and to clean up mud /stone tracked onto street. 03/06/01 R BLD FAIL 1) PROVIDE A COLLAR FOR THE B -VENT 2) PROVIDE FIRESTOPS FOR THE WHIRLPOOL TUB 3) PROVIDE A CODE COMPLIANT EXIT OFF OF THE PATIO DOOR AT THE FINAL 4) PROVIDE STRAPPING FOR THE BASEMENT WINDOWS WITH THE TOP PLATES CUT 5) BLOCK THE POINT LOADS FROM THE GIRDER TRUSSES THROUGH THE BOXSILL R HVAC PASS 03/09/01 (RE) R BLD PASS INSUL PASS NOTE: FRONT STOOP WAS NOT FLASHED 04/19/01 F BLD FAIL 1) MAX. 8" TO GRADE OFF AT THE FRONT STOOP 2) SEAL EDGES OF BRICK TO THE SIDING, CAULK AROUND ALL WINDOWS, LIGHTS 3) MAX. 6" TO GRADE FROM THE SIDING, FINAL GRADE MUST COMPLY WITH ALL SUBDIVISION DRAINAGE REQUIREMENTS 4) INSTALL ADDITIONAL LAG BOLTS FOR THE DECK BEAM 5) PROVIDE STRAPS FOR THE BASEMENT WALLS WHERE THE TOP PLATES HAVE BEEN REMOVED F HVAC PASS 1 F ELEC FAIL 1) MASTER BATHROOM, KITCHEN, BASEMENT WAS NOT READY FOR INSPECTION 04/27/01 (RE) F BLD PASS MAINTAIN EROSION CONTROL (RE) F ELEC PASS 2