Loading...
HomeMy WebLinkAbout0071910-Building CITY OF OSHKOSH No 0071910 OSHKOSH BUILDING PERMIT APPLICATION AND RECORD ON THE WATER Job Address 350 WINDINGBROOK DR Owner KENT MOSEBACH Create Date 08/05/1999 Designer Contractor SECURITY HOMES OF WISCONSIN INC Category 110 New Single Family Plan C7- 108 -799R Type Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning R -1 Class of Const: 8 Size 50' X 66 IRRG Unfinished /Basement 1796 Sq. Ft. Rooms 7 Height 20 Ft. El Projection Finished /Living 1796 Sq. Ft. Bedrooms 3 Stories 1 Canopies Garage 816 Sq. Ft. Baths 2 Signs Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required Dwelling Units 1 Structures 1 Use /Nature NSFR/ New single family with attached garage and driveway. of Work HVAC Contractor BREWER HEATING Plumbing Contractor JIM'S PLUMBING Electric Contractor CUMINGS ELECTRIC Fees: Valuation :0 s Plan Approval $40.00 Permit Fee Paid $300.00 Park Dedication $100.00 Issued By: Date )8/05/1995 Final /O.P. 0 Permit Voided In the performance f is I ee to perform al pursuant to rules goveming the described construction. Signature Date g- r.--q 5 Agent/Owner Address 100 N WESTH EN DR OSHKOSH WI 54901 0000 Telephone Number 414 426 -2045 Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0071910 P.O. Box 7969 APPLICATION Parcel No. Madison, WI 53707 Wisconsin Statues 101.63, 101.73 a 0 Constr HVAC Elec Plbg 0 Erosion Other: Owner's Name Mailing Address Telephone No. KENT MOSEBACH 346 WESTHAVEN DR OSHKOSH WI 54904 0000 Contractor: 12 Con Elec HVAC Plbg Lic/Cert Mailing Address Telephone No. SECURITY HOMES OF WISCONSI 8549 100 N WESTHAVEN DR OSHKOSH WI 54901 0000 414 -426 -2045 Contractor:. Con 0 Elec HVAC 1111 Plbg Lic/Cert Mailing Address Telephone No. CUMINGS ELECTRIC PO BOX 749 NEENAH WI 54957 0749 231 -5946 (Dick Contractor:. Con Elec 0 HVAC Plbg Lic/Cert Mailing Address Telephone No. BREWER HEATING N8804 N DOUGLAS ST RIPON WI 54971 0000 1- 748 -6494 Contractor:. Con Elec HVAC 0 Plbg Lic/Cert Mailing Address Telephone No. JIM'S PLUMBING W -6166 GREENVILLE DRIVE GREENVILLE WI 54942 0000 757 -5258 OR 7 °9y$ Lot Area S•. ft. 1/4, 1 /4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 350 WINDINGBROOK DR SAWYER CREEK SUB 41 Zoning District(s) Zoning Permit No. Front Right d a e y i ('d 77- n ae a ®m x a47; 7 �.1rN'Sx .e,.,. 0 New Repair 0 Single Family Entrance Panel 0 Forced Air Fumace Fuel Nat. Oil Elec. Solid Sola Alteration Raze Two Family Size: 200 am. Radiant Baseboard or Panel Ga Addition Move Garage Service: Heat Pump Space Ht 0 El Other (print): Overhead Boiler Water Htg 0 Other 0 Underground 0 Central Air Conditioning m Dwelling unit will have 3 kilowatt or d� Other more installed electric space heating equip. ti; 0 Site Constructed 0 Concrete m i p g q g ar ti Infiltration control option is: Full sealing Unfinished Manufactured Masonary Sewer of joints. Blower door test. Exterior Basement 1796 Sq. ft. k a Treated Wood Q Municipal air infiltration barrier. Living Area 1796 Sq. ft. 0 1 -Story ❑Other Septic 2-Story Permit No. Envelope 34529 BTU /HR Garage 816 Sq. ft. Seasonal Other 0 Permanent a 'b; Infiltration 12365 BTU /HR Other 0 Municipal Utility 0 Plus Basement Private On -Site Well $105,000.00 The applicant agrees to comply with all applicable la -s and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express r' epartment or mu ;.ality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE i, DATE SIGNED T'S 7 APPROVAL CONDITIONS This permit is issu:. pursu to the following conditions. Failure to comply may result in suspension or revocation of thi •ermit or other penalty SEE STANDARD CONDITIONS Town Village 0 City County State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 2 6 6 x a1 va m" a x e f Y o Plan Review $40.00 0 Construction Inspection El HVAC Name Brian Noe Wis. Permit Seal $30.00 Electrical Date 08/05/99 Other Plumbing 0 Erosion Total $70.00 II 221301 Cert. No. 70266 SBD -5823 (R. 07/92) OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6218 Name KENT MOSEBACH Address 350 WINDINGBROOK DR Create Date 08/05/99 Lot 41 Block Ward Subdivision SAWYER CREEK SUB Zone Street Number Lot Dimensions IRRG Sidewalk Existing Building Grade Elevation Stakes Set At Site 00 /00 /00 Set By Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grad est.: ished before e cavation has commenced. OSHKOSH PARKLAND DEDICATION FEE COLLECTION RECORD ON THE WATER Job Address 350 WINDINGBROOK DR Date 08/05/199f Name KENT MOSEBACH Address 346 WESTHAVEN DR OSHKOSH WI 54904 Subdivision SAWYER CREEK SUB Lot 41 Building Permit Number 0071910 Number of Dwelling Units 1 Number of Structures 1 Fee Required $100.00 Fee Paid Owner's Signature Date X C L Inspector's Signature jam/ Date 'z 9 lifitti1 if (.1) •=7: 0 6 1 0 fn z cr :77 .....1 0 8 ill' .1 .e to tri i-, 4- k a i,, :1 c..i 1 0 1.1 ji g 0 is S 4 :LI,,.1 I— z E allpit) 0 f w „....1 0 e :gig sit t:tki U 1 N., 100•0 L. ..0 0 0 0 ts c t.,-- Z 'I--- 00 1. L906 CD N 4 V N U4 -0 14. (2 t 1 sb I 0 0 0 6 i i CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address 350 LD 1 uO1)6 Permit 171° Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. 2. Garage spaces shall be seperated from the dwelling unit in accordance with ILHR 21.08. 3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. 5. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 6. All overframing must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner /applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2 -3" diameter stone is required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each work day. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, citations will be issued. Additional placards can be obtained through our department if the cards are misplaced.. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $25 re- inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid $25 re- inspection fees per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum.of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' step ladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. -C