HomeMy WebLinkAboutElectric - 11/04/2002 INSPECTION SERVICES DIVISION CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH Room 205 PO Box 1130
ON THE WATER CORRECTION NOTICE OSHKOSH WI 54903-1130
Issue Date 11/4/02 Compliance Date 12/4/02 IMMEDIATELY Compliance No
Address 442 MONROE ST Inspected By Kevin Benner 236 -5046
Name Address City State Zip Code
Sent to a Owner ST MARY'S CATHOLIC CHURCH 442 MONROE ST OSHKOSH WI 54901 -0000
Contractor C &S ELECTRIC INC 105 WATSON ST RIPON WI 54971 -0000
Li Other 0 -0000
HI Inspector
u Required for Occupancy Occupancy Commercial Notice First O Final 0 Other
Violations must be corrected and approved within 30 days unless otherwise noted. CaII for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 12/4/02
Introduction While conducting a routine inspection for other work being done in the above noted building the following violations were
noted.
Item 1 Code MO 11 13 Compliance No Compliance Date 12/04/2002 IMMEDIATELY
Description Upon the completion of any electrical installation, alteration or replacement it shall be the duty of the licensee or authorized
person conducting the installation to request an inspection.(final inspection underground)
Item 2 Code NEC 347 Compliance No Compliance Date 12/04/2002 IMMEDIATELY
Description Ridgid non metallic conduit shall not be used in a place of assembly.
Item 3 Code COM 16.295 Compliance No Compliance Date 12/04/2002 IMMEDIATELY
Description Where portions of a raceway(s) pass from an interior location to an exterior location, the raceway(s) shall be sealed to prevent
the transfer of air.
Item 4 Code NEC 110 14(a) Compliance No Compliance Date 12/04/2002 IMMEDIATELY
Description Connection of conductors to terminal parts shall ensure a thoroughly good connection without damaging the conductors.
(appropriate wire terminals shall be used for the termination of conductors [grounding of light fixtures equipment grounds in
panels &disconnects])
Item 5 Code NEC 384 13 Compliance No Compliance Date 12/04/2002 IMMEDIATELY
Description All panelboard circuits shall be accurately identified as to the purpose or use
Page 1 of 4
INSPECTION SERVICES DIVISION CITY OF OSHKOSH
DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH Room 205 PO Box 1130
ON THE WATER CORRECTION NOTICE OSHKOSH WI 54903 -1130
Issue Date 11/4/02 Compliance Date 12/4/02 IMMEDIATELY Compliance No
Address 442 MONROE ST Inspected By Kevin Benner
Name Address City State Zip Code
Sent to u Owner ST MARY'S CATHOLIC CHURCH 442 MONROE ST OSHKOSH WI 54901 -0000
u Contractor C &S ELECTRIC INC 105 WATSON ST RIPON WI 54971 -0000
Li Other 0 -0000
u Inspector
U Required for Occupancy Occupancy Commercial Notice 11 First 0 Final 0 Other
Violations must be corrected and approved within 30 days unless otherwise noted. CaII for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 12/4/02
Introduction While conducting a routine inspection for other work being done in the above noted building the following violations were
noted.
Item 6 Code NEC 700 12(e) Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description Storage batteries used for emergency illumination shall have th capacity to supply and maintain total Toad for a period of 1.5
hours. (while testing an exit light the battery was failing)
Item 7 Code Comm 73.17 Compliance Compliance Date 12/05/2002
Description Emergency illumination other than exit lights shall be provided in the lobbies, halls, corridors, stairways and means of egress
Item 8 Code NEC 700 12 Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description Emergency illumination shall be installed to provide illumination when the normal supply for lighting is interupted.
Item 9 Code NEC 380 9 Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description Snap switches shall be effectively grounded.
Item 10 Code NEC 370 20 Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description In walls or ceilings boxes shall be installed so that the front edge of the box will not be set back of the finished surface more
than 1/4 In surfaces constructed of combustible material boxes shall be flush with the finish surface.
Page 2 of 4
INSPECTION SERVICES DIVISION CITY OF OSHKOSH
ice} DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH Room 205 PO Box 1130
ON THE WATER CORRECTION NOTICE OSHKOSH WI 54903 -1130
Issue Date 11/4/02 Compliance Date 12/4/02 IMMEDIATELY Compliance No
Address 442 MONROE ST Inspected By Kevin Benner
Name Address City State Zip Code
Sent to U Owner ST MARY'S CATHOLIC CHURCH 442 MONROE ST OSHKOSH WI 54901 -0000
✓J Contractor C &S ELECTRIC INC 105 WATSON ST RIPON WI 54971 -0000
H1 Other 0 -0000
HI Inspector
J Required for Occupancy Occupancy Commercial Notice First 0 Final 0 Other
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 12/4/02
Introduction While conducting a routine inspection for other work being done in the above noted building the following violations were
noted.
Item 11 Code NEC 300 11 Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description Class 2 cables shall not be secured to raceways containing power circuits except for associated equipment
Item 12 Code NEC 725 54 Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description Cables and conductors of Class 2 circuits shall not be placed in any compartment, enclosure, outlet box, device box, raceway,
or similar fitting with conductors of electric Tight, power, etc.
Page 3 of 4
INSPECTION SERVICES DIVISION CITY OF OSHKOSH
r �l� DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE
OSHKOSH Roo 205 PO Box 1130
ON THE WATER CORRECTION NOTICE OSHKOSH WI 54903 -1130
Issue Date 11/4/02 Compliance Date 12/4/02 IMMEDIATELY Compliance No
Address 442 MONROE ST Inspected By Kevin Benner
Name Address City State Zip Code
Sent to u Owner ST MARY'S CATHOLIC CHURCH 442 MONROE ST OSHKOSH WI 54901 -0000
J Contractor C &S ELECTRIC INC 105 WATSON ST RIPON WI 54971 -0000
L Other 0 -0000
J Inspector
J Required for Occupancy Occupancy Commercial Notice 0 First 0 Final 0 Other
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 12/4/02
Introduction While conducting a routine inspection for other work being done in the above noted building the following violations were
noted.
Item 13 Code NEC 370 17 Compliance No Compliance Date 12/05/2002 IMMEDIATELY
Description Unused electrical openings shall be effectively closed.
Summary To avoid any further inconveneince please correct the above noted violations immediately. An
y p y Any questions or concerns please
feel free to contact me at 236 -5046.
DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL (920) 236 -5050 FOR INSPECTION.
Signature p.4,(4 a Date h 11
400114
I hereby iolations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Page 4 of 4