HomeMy WebLinkAboutCertificate of OccupancyFIXTURE SCHEDULE
D -1
1 PRE -HUNG WOOD DOOR WITH LEVER HANDLE. BATHROOM
FUNCTION LOCKSET.
p_
1" PRE -HUNG WOOD DOOR WITH LEVER HANDLE.
CLASSROOM FUNCTION LOCKSET.
D -3
it PRE -HUNG EXTERIOR DOOR PREHUNG W/ LEVER HANDLE.
ENTRANCE LOCKSET HANDICAP ACCESSIBLE SILL ON
THRESHOLD.
D_
1" PRE -HUNG WOOD DOOR WITH LEVER HANDLE.
CLASSROOM FUNCTION LOCKSET.
FIXTURE SCHEDULE
WC_1
MANSFIELD QUANTUM SMARTHEIGHT PRESSURE ASSIST
TOILET MODEL #148 -123 WITH SLOAN VALVE. PROVIDE NEW
WAX SEAL. KOHLER STRONGHOLD TOILET SEAT MODEL
#K- 4731 -SC.
L -1
MANSFIELD GRANDE ISLE WALL MOUNT LAVATORY MODEL
#2018HBNS -4. ZURN 4" CENTERSET GOOSENECK FAUCET
MODEL #Z812B4.
8
T. EXISTING HEATER
TO REMAIN
w
Z
0
w
0
813 PRE -FAB PILLAR --f
11 1 8"
48" HALF WALL
W/ WOOD CAP
2 -2x8 HEADER
UNCASED OPENING
DRYER STATION
1 UNDETERMINED
SHELVES
AND DESK
BY OWNER
EMERGENCY LIGHTING BATTERY
PACK. CONNECT TO ELECTRICAL
4 FINISH FLOOR LEVEL 100' -0"
EXISTING HEATER
TO REMAIN
FIRST FLOOR DEMO PLAN
SCALE: 1/4" 1' -0"
EXISTING HEATER
TO REMAIN
48" HALF WALL
W/ WOOD CAP
8 "0 PRE -FAB PILLAR
SHERRY'S SALON
`"I
42" KNEE WALL
W/ WOOD CAP
42"
HAIR STATION
PEDICURE STATION
RAMP S
4' -6
SHAMPOO
STATION
PATCH WALL lT0 MATCH
ADJACENT SURFACES
HAIR STATION
UP
SCALE: 3/16" V-0'
OPE NOT TO EXCEED 1 :12
FIRST FLOOR PLAN
3 -2x8 HEADER
4' -0"
PATCH WALL TO MATCH
ADJACENT SURFACES
1 ELECTRICAL
4'-0
D-
3'0 x 6'8
EXISTING ELECTRICAL
PANELS TO REMAIN
Al
N
3 -2x8 HEADER
'MECHANICAL
5' -0"
INSULATED STEEL
ENTRY DOOR
Z LU
KFI REMOVE AND DISPOSE OF EXISTING WALL AS INDICATED.
PATCH ALL DISTURBED SURFACES TO MATCH ADJACENT
FINISHES.
KII::: REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME.
TURN HARDWARE OVER TO OWNER.
0 REMOVE AND DISPOSE OF EXISTING WATER HEATER.
DISCONNECT SUPPLY CAP AT WALL.
0 REMOVE AND DISPOSE OF EXISTING PLUMBING FIXTURE,
CAP WASTE AND DISCONNECT CAP SUPPLY AT WALL.
0 REMOVE AND DISPOSE OF EXISTING WATER CLOSET.
0 SAW CUT AND REMOVE EXISTING FINISH FLOOR
SUBFLOOR AS REQUIRED TO EXPOSE FLOOR JOISTS
RIM JOIST BELOW.
7O SAW CUT EXISTING FLOOR JOISTS AS REQUIRED TO
ALLOW FOR ADA RAMP. (NOTE: RAMP SLOPE SHALL NOT
EXCEED 1:12).
DEMOLITION NOTES
EXIT
EXIT ROUTE
WAITING 1
NEW POURED CONCRETE PAD.
SLOPE AS INDICATED
PATCH WALL TO
MATCH ADJACENT
SURFACES
j raf
EXISTING HEATER
TO REMAIN
w
z
z
w
0
(46 t
GENERAL NOTE FOR PLAN REVIEWER
UPSTAIRS APARTMENT HAS A 60 AMP
SUB PANEL. TENANT HAS KEYS TO
REAR ENTRANCE AND FIRST FLOOR
MECHANICAL ROOM.
ADA GRAB BAR
.fix," ADA GRAB BARS
TRASH RECEPTECLE
1' -3" PAPER TOWEL DISPENSER
BY OWNER
TOILET ROOM ELEV. t
SCALE: 1/4" 1' -0"
TOILET ROOM ELEV. 7- 2
SCALE: 1/4" 1'_0" Al
1' -0"
2x4 WOOD STUDS
16" O.C.
4" DRYWALL
(BOTH SIDES)
2x WOOD JOIST 12" O.C.
CUT TO MATCH 1 :12 SLOPE
SUBFLOOR W/
NON -SLIP SURFACE
WOOD CAP
PROVIDE NEW FLOOR
JOIST TO MATCH
EXISTING JOISTS AT
EDGES OF NEW RAMP
NEW CMU :WALL TO
RUN WIDTH OF NEW
ADA RAMP
CUT EXISTING FLOOR JOISTS
RIM JOIST AS REQUIRED TO
ALLOW FOR NEW ADA RAMP
1" WOOD HANDRAIL
EXISTING FOUNDATION
WALL FOOTING
RAMP SECTION
SCALE: 1/2"
L
9' -6
1 =111
-Ill
I[- -III -4
2x4 STUDS 16" O.C.
rr
1i" WOOD HANDRAIL
i i
(TYP)
i 1 I I I_.._111 f
1 =1
111.= 11I =j
RAMP SECTION
SCALE: 1/2" 1' -0"
1" DRYWALL
5' -2"
I I
VIII "111
111 I 11
1 1 āI f f 1 I I
WOOD CAP
(4Th
IIT Jā"
ā111- 11 1117=1 1
1 -111 1
ii_i III 1
MATCH THICKNESS
OF ADJACENT WALL
POURED
CONCRETE
FOOTING BEYOND
NEW CMU WALL POURED
CONCRETE FOOTING PLACED
BENEATH CUT FLOOR JOIST