HomeMy WebLinkAbout0137339-HVAC (air handling unit)0 OSHKOSH ON THE WATER Job Address 2737 HARRISON ST CITY OF OSHKOSH HVAC PERMIT -APPLICATION AND RECORD Owner OSHKOSH CORPORATION No 137339 Create Date 07/30/2009 Contractor CONKLIN SHEET METAL INC Category 512 - Ind. & Comm -Both Plan Fuel ✓ Gas L Oil ✓ Electric L Solar L Solid System ❑✓ New ❑ Replace [] Other ✓ Forced Air Radiant Steam ✓ A/C Vent Electric Hot Water LESUPPI. L Con. Burner Chimney Type Chimney A Chimney B 0 Direct Vent Not Applicable Heat Loss U As Approved Existing Not Applicable Value BTU Rate As Per Plan Variable Other Value Use /Nature of Work ND/ Add one air handling unit with electric heat and cooling to new plant office area located under existing mezz. Fees: Valuation x,$,980.00 Plan Approval $0.00 Permit Fee Paid $100.00 Issued By: ❑ Permit Voided) Date 07/30/2009 Parcel Id # 1519600000 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit ap ication within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secur i!;necessa pprovals before starting such activity. 1 Signature Date 2- 10;09 Agent/Owner Address 450A LINWOOD AVE OSHKOSH WI 54901 - 0 Telephone Number 231 -3744 To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. City of Oshkosh Division of Inspection Services P.O. Box 1130 Oshkosh, WI 54903 -1130 Phone (920) 236 -5050 Fax (920) 236 -5084 • Application(s) and fee(s) can be Oshkosh WI 54903 -1128. Com normal permit fee, which ever is OR If you are a contractor participc if vnu want this processed throw -IVAC PERMIT APPLICATION information after bold categories must be provided. Incomplete applications will not be processed. V (0 OfHKOfH ON THE WATFR to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, work without permit(s) will result in fires being doubled or $100.00 plus the t to ** Advisory - For applicable projecl s, an Electrical Installation Verification (EIS form, signed by the Electrical Contractor or Homeowner (for installations allowed to be performed by the homeowner) must be submitted with the permit application. Applications submitted without an EIV when such is required, will not be processed for Permit Issuance and Nvill be returned for completion. DATE � _ �0 JOB ADDRESS r t o 6t OWNER c - C c 'e, Y) CONTRACTOR C CHECK 0 ALL APPLICABLE USE CATEGORY / ❑Single Family ❑Duplex Multi - Family ❑Rental ❑Commercial ern - dustrial FUEL ❑Gas lectric Solid SYSTEM 135-e—W, ❑Replace ❑Oil ❑Solar ❑Other TYorced Air ❑Radiant ❑Ste 2<,,C' ❑Ve,nt lectric ❑Hot Water ❑Suppl. ❑Con. Burner IS CHIMNEY BEING LINED ❑Yes - LINER SIZE & MANUFACTURER Note: All chimneys shall be sized per the BTU's being vented. CHIMNEY TYPE ❑Chimney A ❑Chimney B ❑Direct Vent ❑Other HEAT LOSS ❑As Appro ed ❑Existing ❑Not Applicable BTU RATE ❑As Per Plai ❑Variable ❑Oth`eer Value DESCRIPTION / SCOPE OF AIL WORK BEING DONE 0 h 4Au i �% 1 e ac rei A444 CGO I rn� tG Ylc�,�� (Gl A G -V,, -! c VALUE (Including labor and materi ELECTRICAL CONTRACTOR (for projects not requiring an EIV Form) 07/07 Page 1 of 1 Noe, Brian From: Joel Clary Mech Engr [sun�mitdesign @fastbytes.com] Sent: Tuesday, July 21, 2009 9:53 PM To: Conklin Rob Much; james.$chulz @galarson.com; Noe, Brian; Osh Trk Ryan Meyers Subject: OSHKOSH TRUCK DEFE�SE PLANT OFFICE GAGE LAB, DEFENSE Attachments: H3.pdf; H1.pdf; H2.pdf; Factory Heat Loads.pdf ATTACHED ARE THE DRAWIGS FOR THb ABOVE PROJECT. PLEASE CALL WITH ANY QUESTIONS. JOEL CLARY PE MBA CGD SUMMIT DESIGN LLC 920 - 979 -5452 PHONE 920 - 924 -5452 FAX 7/22/2009 wY^!ru twr��v NISNOOSIM'HSONHSO 13381S NOSIUNri LELZ rvouraoaum rreovHao O INV�d 3SN3d Ni IS� 34 - NOLLVUOdHOO HSO)IHSO 2, NoudlaOS3a eve 3onvo / 3oIjj0 — S l# Asvl nlvw Siva �n3a J v J ow y FV �a U) °o q� wq rg :g N = :E a Y iza gg ui a � o � Mi W W Lu Z N LL N _ < cn €ty GG pN5 U { w V) m ; > y w I€ ' w 4 0 tai i� Z z s LINED DUCT O z o 'o. F 3 UW " y hg z LLI } g FURNACE Y o a q d§ HE W yi8 9aM k O LLJ g sayQowo 1T W W mot3 � 5 Ell Z. yi ea .o ri LL- k � md _ — 4 Dmm �:O D X M O m D 0 Z _ A0 a D TI m ;:u D X JI m O � D O Dmm a7D X mc�� D 0 D�F m0 V {p c mp r m . Eu __.. C- D .- ;7 K: ZJ CO m OOX OT. K:.Zml� N D m m - ,- 0 ;D D X M 7 C Oz = = = = =e �p 1®', - D m m _ �;7Dx d? m0� D 0 0 Z �;u G7 CO D m Z] C) m > D p m r m TI X �0 CO X TI x 0 0 TI�(Il m m0� (n (� p � D < , Opp m 0 TI mI ,O Z (n m Z m Z _ ICJ CD p �0 cZ O m m r T1 Om Z O ' O O I'<� LC pT N X .... ... _..m N f�Tl Om N .3 Tito xK m0 m� m 0-pZ —IN g r r r n _ MAN TASK #15 — OFFICE / GAUGE LAB REV. DATE DESCRIPTION N 051�SH OSHKOSH CORPORA -nON - DEFENSE PLANT o 2737 HARRISON STREET OSHKOSH. WISCONSIN Air System Design Lead Summary for ELECTRIC FURNACE SIZE Project Name; OKT FACTORY 0712112009 P red : Summit I n 03:19PM Hourly Analysis Program v,4.4 Page 1 of 1 DEAN COMING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB 1 WB 85.9'F/72.4F HEATING DATA AT DES HTG H €ATII DA DB / WB -13.0 °F 1-134 °F ZONE LOADS Details Sensible Latent BTt)thr) (BTU1hr) Details Sensible (BTU/hr) Latent (IM/ r) Window & Skylight Solar Loads 0 ftx 0 0 W Wall Transmission 0 fta 0 0 ft? 0 =' Root Transmission 400 fix 430 400 ftx 821 Window Transmission 0 ftx 0 0 fix 0 - Skylight Transmission 0 ftx 0 - 0 fiz 0 Door Loads 0 ftz 0 0 W 0 Floor Transmission 642 fix 0 642 iix 0 Partitions 0 fix 0 0 ft? 0 Calling 0 fix 0' 0 fix 0 Overhead Lighting 1899 W 5574 0 0 Task Lighting 0 W 0 0 0 Electric Equipment 1321 W 4227 0 0 People 4 1503 2980 0 0 0' Infiltration - 0 0 0 0 Miscellaneous 0 0 0 0 Safety Factor wo / 0 */a 0 0 0% 0 0 >> Total Z4ft t - 11734 2980 - 821 0 Zone Conditions - 12380 2980 1109 0 Plenum Wail Load 0% 0 - 0 0 Plenum Roof Load 01ya 0 0 0 Plenum Lighting Load Return Fan Load 0°ya 658 CFM 0 0 - 0 658 CFM 0 0 Ventilation Load Supply Fan Load 30 CFM 658 CFM 317 493' 0 30 CFM 658 CFM 2625 0 0 S ace Fan Coil Fans 0 0 Duct Heat G=rin / Loss 0% 0' - 00% 0 s> Total S}sterrr Loads - 12698 3473 - 3738 0 Central Cooling Coil - 12698 3475 0 0 Central Heating Coil 0 - 3738 -' >> Total Conditioning - 126981 3475 - 3738 0 Key: Positive values are cig loads Negative values are htg loads Positive values are Mg loads Negative values are clg loads Hourly Analysis Program v,4.4 Page 1 of 1 Page 1 of 1 Noe, Brian From: Joel Clary Mech Engr [summitdesign @fastbytes.com] Sent: Monday, August 03, 2009 4:57 PM To: Conklin Rob Much; Noe, Brian; Osh Trk Ryan Meyers Subject: OKT Office 273-7 japt}Z��h1 S� Attachments: H3.pdf; H1.pdf; H2.pdf; OKT LOADS2.pdf REVrsEJD Hvac <oR t�epin, 7 M 137339 8/4/2009 0 Rg �� Nis n mg ° o ^pRom m PICI ag ' 0. MINE z i fl 1 U) > Q 33 £ g O Figs z = o 4NO U) m iE = e 8 Re m s g � 3 F "C p i IM r � c _m a c mx f gx° x -og % ox �gz gF o3 °$gs Fx° Y ?; "_ o €p$F m.oS9�fr mm pFmo flu ma h n mR mya -� o - '�_ E a oil g€ y�� s w e e A� tim m m� 9� z _ MAN TASK #15 — OFFICE / GAUGE LAB REV. DATE SDESCRIPTION 05OMN OSHKOSH CORPORATION - DEFENSE PLANT " 2737 HARRISON STREET OSHKOSH, WISCONSIN a r0 �� a e D ❑l p �E/ Z��k�� 1f aa66 't C3 F r gg Lm a c Z n � R ° S m � d r � � yA r „ y O £ �g = l�na a3un .s zip m p D � n w. Em i Nola W 0 o0 3 p i 3 ag a�e�;ea ^� — X43 Z n ��� vm R9� ". . R m i D � m _ I D x F7 D m m m n Dom z 0 D TI m � D X M O cf) j D 0 O L z jl "O G� �� i' 1 �coX ' D 02 m O- --- -- - -�. D <O CC) O O 0 _ D n \ m n r 70� O U)m O O x o D m m D N O: O 1 D m m �;o D x m mC�� D O z O �® 4 D > X �J X I M Cf) D ' Z ;43 C7 a � j CO D m�;o O f m D D O m r m m x �;u C3 x �1 X O D -7 Ln cn (n m O (n Fl) m Tl Z .. z ;;u Z X _.._..., C) C O O C7 C/) m r Om z gnm �O i < m a O N m m x m m O� N m =3 � c ,� � � r ri N $ A; m O z Z m N � e CJ i 7U E r _ ' MAN TASK #15 - OFFICE /GAUGE LAB REV. 0 0° oESCR�iRrI � 051�15H OSHKOSH CORPORATION - DEFENSE PLANT b w 2737 HMRISON STREET OSHKOSH, WISCONSIN ani-.e a.,� race• Air System Design Load Summary for office 1 only Project Name: OKT FACTORY 08/03/2009 Prepared by: Summit Design 11:35AM Hourly Analysis Program v.4.4 Page 1 of 1 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1800 ` COOLING OA DB / WB , 83.7 °F 171.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB -13.0'F/-13.8'F ZONE LOADS Details Sensible (BTU /hr) Latent (BTU /hr) Details Sensible (BTU /hr) Latent '; (BTU /hr) Window & Skylight Solar Loads 0 ft2 0 0 ft2 Wall Transmission 0 ft2 0 0 ft2 0 Roof Transmission 0 ft2 0 0 ft2 0 Window Transmission 0 ft2 0 0 ft2 0 Skylight Transmission 0 ft2 0 0 ft2 0 Door Loads 0 ft2 0 0 ft2 0 Floor Transmission 242 ft2 0 242 ft2 0 Partitions 0 ft2 0 0 ft2 0 Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting 399 W 1185 0 0 Task Lighting 0 W 0 0 0 Electric Equipment 121 W 389 - 0 0 - People 1 205 205 0 0 0 Infiltration - 0 01 0 0 Miscellaneous 0 0 - 0 0 Safety Factor 0%/0% 0 0 0% 0 0 Total Zone Loads 1779 205 - 0 0 Zone Conditioning - 1848 205 - 0 0 Plenum Wall Load 0% 0 0 0 - Plenum Roof Load 0% 0 0 0 Plenum Lighting Load 0% 0 - 0 0 Return Fan Load 99 CFM 0 - 99 CFM 0 - Ventilation Load 8 CFM 61 140 8 CFM 655 0 Supply Fan Load 99 CFM 0 - 99 CFM 0 - Space Fan Coil Fans 0 - 0 Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads 1909 345 - 655 0 Central Cooling Coil 1909 345 0 0 Central Heating Coil 0 - 655 - » Total Conditioning 1909 345 6551 0 Key: Positive values are'cig loads Negative values are htg loads Positive values are htg loads Negative values are cig loads Hourly Analysis Program v.4.4 Page 1 of 1