Loading...
HomeMy WebLinkAboutBuilding 90-03-0320-B �a State of Wisconsin Department of Industry, Labor and Human Relations SAFETY BUILDINGS DIVISION 201 E. Washington Avenue P.O. Box 7969 Madison, Wisconsin 53707 April 5, 1990 File Number E -9532 Stephen Gries Ron Leichtfuss 1233 S. Commercial Street 325 N. Sawyer Street Heenan, WI 54956 Oshkosn, WI 54901 Re: Apartment Builainq #7 Ron Leichtfuss, Owner /2S' Cimarron Place Oshkosh, Winnebago County Plan Number 90 -03- 0320 -B Volume: 82,000 Cubic Feet Supervisinq Architect Stephen Gries Your building plans have been conditionally approvea. The plans have been reviewed for compliance with the coae reouirernents set forth in Chapters ILHR 50 -64 of the rules of tne department. Construction may Proceed sun.iect to local regulations, but all items tnat are reauired to be chanced by this letter must be corrected before commencing that part of tne work. 'This plan nas not been reviewed for compliance with Cnapters ILHR 82 -86, the plumbing rules of the department. You are hereby advised that the owner as defined in Chapter 101.01(2)(e) of the Wisconsin State Statutes is responsible for all code reouirements not specifically cited herein. The building will be inspected during ano after construction. Tne owner shall notify the state huildinq inspector and the local officials before taking Possession of the building. ILHR 50.15 Evidence of Approval. The architect, professional engineer, designer, builder or owner shall keep, at the building, one set of plans bearing the stamp of approval. ILHR 57.17 A fire alarm shall be provided. A fire alarm station shall be Placed at each balcony as well as at eacn front door. ILHR 64.02 This approval does not include heating, ventilating aria air conditioning. SBD -8928 (R. 10/87) Gti State o f Wi sconsin Department of Industry, Labor and Human Relations SAFETY BUILDINGS DIVISION 201 E. Washington Avenue P.O. Box 7969 Stephen Gries Madison, Wisconsin 53707 Page 2 April 5, 1990 ILHR 50.12 Truss plans ana calculations along with tne proper tees ana Plan Approval Application Form (SB -118) shall be submittecr to this office and approved prior to installation of that component. Ali component plan application forms for buildings greater tnan 50,000 cubic feet in volume snail include the name of the building or component aesigner and be signers by tne supervising professional of the project. '2 :This building is classifies as Ho. 8, wooa frame construction. ILHR 57.14 The furnace ...cum snail be encloses with 1 -nour construction. /R OP 57.16 Smoke detectors shall be provided. ILHR 52.04 Ten percent of the units ana 50 percent of tne building snail be accessible for the physically handicapped. Sincerely, R. L. Klein Plan Examiner (608) 266 -1589 RLK:3292q cc: R -3 Rubio (414) 497 -4468 Friday Building Inspector, Oshkosh f 1 SBD -6928 (R. 10/87)