Loading...
HomeMy WebLinkAboutBuilding 89-11-0122-B COL IJ tv lemq ,r S tate of Wisconsin Department of Industry, Labor and Human Relations SAFETY BUILDINGS DIVISION November 27, 1 98 t 201 E. Washington Avenue P.O. Box 7969 File Number E-009532 Madison, Wisconsin 53707 STEPHEN GRIES ROIJ LEICHTFUSS 1233 SOUTH COMMERCIAL STREET 325 NORTH SAWYER STREET NEENAH, WI 54956 OSHKOSH, WI 54901 aD�► RE: APARTMENT RON LEICHTFUSS 8 -UNIT 11 CIt-IARRONJ PLACE OSHKOSH County of WINNEBAGO Plan Number 89 -11- 0122 -B Volume: 111,575 cubic feet Suprv. Professional, Building: STEPHEN GRIES Firm Project No: 555 Your Building plans have been conditionally approved. The plans have been reviewed for compliance with the code reouirements set forth in Chapter ILHR 50 -64 of the rules of the department. Construction may proceed subject to local regulations, but all items that are reouired to be changed by this letter must be corrected before commencing that part of the work. This plan has not been reviewed for compliance with Chapters ILHR 82 -86, the plumbing rules of the department. You are hereby advised that the owner, as defined in s. ILHR 101.01 (2)(e) of the Wisconsin State Statutes, is responsible for all code reouirements not specifically cited herein. The building will be inspected during and after construction. The owner shall notify the state building inspector and the local officials before taking possession of the building. ILHR 50.15 EVIDENCE OF APPROVAL. The architect, professional engineer, designer, builder or owner shall keep at the building, one set of plans. ILHR 64.02 This review does not include heating, ventilation and air conditioning. ILt3R 50.12 Truss plans and calculations along with the proper fees and Plan Approval Application Form (SB -118) shall be submitted to this office and approved prior to installation of that component. All component plan Application forms for buildings greater than 50,000 cubic feet in volume shall include the name of the building or component designer and be SIGHED by the supervising professional of the project. SBD -6928 (R. 10/87) v tit State of Wisconsin Department of Industry, Labor and Human Relations SAFETY BUILDINGS DIVISION 201 E. Washington Avenue P.O. Box 7969 STEPHEN GRI ES Madison, Wisconsin 53707 November 27, 1989 Page 2 ILHR 53.11(4)(c) Provide for additional snow load on office roof due to changes in roof elevations. Provide calcs in truss plans. ILHR 51.16(5)(c) Stairs include platforms; rooms under stairs and platforms are not permitted. ILHR 53.63(1) Detail 2/4 wall intersects with floor system and with bottom chord of truss, and FIRE STOPPING is required at these locations to prevent spread of fire through concealed spaces. ILHR 57.17 FIRE ALARM is rewired with pull stations per ILHR 51.24(4). ILIiR 57.16(1)(b) (c) Smoke detectors are required at head of open stairs and in sleeping areas. ILHR 51.14 Provide safety glass in hazardous impact areas. This building is classified as No. 8, wood frame construction. Sincerely, Duane E. Peterson Plan Examiner (608) 266-7849 DEP:vs:1229 cc: State Building Inspector: R -3 Ochs (414) 929 -3167 Friday .building Inspector, OSHKOSH SBD -6928 (R. 10 /87)