January 21, 1986
Mr. Terry Eisch
250 N. Campbell Road
Oshkosh, Wisconsin 54901
Dear Mr. Eisch:
Subject: Maricopa Drive Contominiums
Outside stair risers
This letter is to follow up on our conversation on 1 -11 -86 regarding my
inspection of the subject condo's stair risers.
Please be advised that Wisconsin State Building Code rule I.L.H.R. 51.16
limits the risers of public exit stairs of condominiums to a height of
7 3/4" as measured from tread surface to tread surface. I will list each
building by its street numbers and the measurements of the top risers of
each stair.
#1777 8 -1/4" #1779 8- 5/16" #1761 8" #1765 8 -1/8"
#1745 8" #1747 7- 15/16" #1755 8- 1/16" #1757 OK
#1733 OK #1735 OK #1737 OK
#1781 8 -1/2" #1783 8 -1/4" #1785 OK #1787 OK
#1793 OK #1795 OK #1797 OK
As you have agreed to take remedial action as soon as possible, a new
compliance date of 4 -1 -86 will be set.
Thanking you for your cooperation, I remain
Sincerely yours,
Clayton Bries
Supervisor Building Inspection
cc: City of Oshkosh
Madison
DI LHR -SBD -5524
1) State of Wisconsin Department of Industry, Labor and Human Relations
December 21, 1981
SAFETY BUILDINGS DIVISION
File Number 114111 201 E. Washington Avenue
P.O. Box 7969
Madison, Wisconsin 53707
Mr. Jaws R. Larson, Architect
219 Washington Avenue
Oshkosh, WI 54901
Dear Mr. Larson:
12 Unit Condominium snildimg, #108
Terry Stroh, Owner
Marianna Drive
Oshkosh, Winnebago County
Plea Numbers 61- 12- 0006 -i
Volume: 118,300 Cubic feet
$151.20 Inspection Fees hid
James E. Larsen, Supervising Professional
Building and heating and ventilating plans have been reviewed by the Department
of Industry, Labor and Ram Relations for compliance with the important code
requirements. The plans are stamped 'Conditional) w
may Proceed subject to )coal y �n'°�+ and construction t corrected �betoreau it that w required to be
by this letter asst be that part of the
Iou are hereby advised that the owner as defined in Chapter 101.01 (2) (i) of
the Wisconsin State Statutes is responsible for all oode requirements not
specifically cited herein. Code
64 of the Rules of the Department. requirements are set forth in Chapters 50 thru
The building will be inspected during and after oonstruotias by a deputy of
this Department to insure complete mplianoe with Wisconsin Codes. The owner
may notify the state building inspeotor listed below it a final ins
desired before taking possession of the building. peoticn is
Ind 50.15 lshidekoe of approval. ?he arohiteot, professional engineer,
designer, builder or owner shall keep at the building, one set of plans bearing
the stamp of approval.
This building is classified as No. 8, wood frame unprotected construction.
Ind 51.161 (4) Handrails shall be in c mpliance with this section,
Ind 64.20 (3) The eleotrio baseboards shall be of an approv t
Ind 57.22 (1) and Ind 51.24 Provide a firs alarm system in oamplianoe with
these sections.
Ind 53.63 Mood exposed to moisture shall be adequately ventilated or
treated with preservative in compliance with this section.
DILHR -SBD -5850 7 u y
Mr. James E. Larson, Architect
Deofiaber 21, 1981
Pais 2
Ind 50.12 Submit complete structural calculations for the
and its supports, showing top steel if required. 3 platform slab
This approval includes the truss and illumination plans.
Very truly yours,
Plan n�i
SN$M00503
sot Coriil, phone 71 5.146..3493, Friday a.m. hkosh Bldg. Insp.
Mr. Terry Eisch
1755 Marioopa Drive
Oshkosh, WI 54901
t
L2